Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹1.7 Cr
EMD Value
₹50,000
Closing Date
11 Jul 2024, 3:00 pmClosed
Superintending Engineer
Superintending Engineer Public Health Circle Kerala Water Authority Thiruvananthapuram
Urban Agglomeration UA 20 21 Karakulam Panchayath Construction of pump house at Kepco part 4/4
2024_KWA_678554_1
172/2023-24/KWA/PHC/D3/TVM/RT5
Open Tender
Civil Works - Water Works
Item Rate
365 days
Karakulam
Pls refer NIT
7 documents required · 7 mandatory
₹6,508
₹50,000
Yes
8 Nov 2024
3 Jul 2024
12 Jul 2024
3 Jul 2024
11 Jul 2024
3 Jul 2024
3 Jul 2024 - 11 Jul 2024
Amount
Construction of online booster Pump house at Kepco -working charges
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
OD219795/2023-2024:Stacking and Conveying the excess soil from the site and disposing the same with an average distance of 5km by lorry etc as directed by the departmental officers
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
50.9.1.3:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). using good quality Vengai wood
50.9.2.3:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer in -charge. using Vengai wood
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
OD219796/2023-2024:Fixing wall casting pipe of 150mm dia CI material in the floor slab of tank
13.71:Lettering with black Japan pint of approved brand and manufacture
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD219797/2023-2024:Supplying and Fixing 110mm PVC 6 kg pipe for drain out water from the top of pump house
OD219798/2023-2024: Supply and delivery at site over head traverse gantry girder crane of 3.0 Tonne capacity hand operated traverse with under head slung, traverse cross trolly having rail to rail traverse horizontally movement supported on travelling girders having free to back horizontal movement etc. satisfying relevant IS specification including all fittings, conveyances, erection, field test as per IS and commissioning.
OD219799/2023-2024:INTERNAL ELECTRIFICATION OF PUMP HOUSEBUILDINGS-<br>Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.<br>Group B-2 nos, Group C- 11 nos, 2 X 1.5 sq. mm + 1 X1.5 sq. mm earth wire-100m, <br>2 X 2.5 sq. mm + 1 X2.5 sq. mm earth wire-30m, 5/6 A switch-3 nos, 15/16 A switch-2 nos, <br>3 pin 5/6 A socket outlet- 3 nos, 6 pin 15/16 A socket outlet- 2 nos, <br>Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate<br>switch box including connections but excluding modular plate etc. as required- 1 no<br>3 M o d u l e ( 1 0 0mmX75 mm)- 1no, 6 M o d u l e ( 2 0 0mmX75 mm)- 2 nos, <br>Installation, testing and commissioning of wall /ceiling fittings of all sizes and shapes containing up to two<br>GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required<br>Installation, testing and commissioning of pre-wired, fitting of all types, complete with all accessories and<br>tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.- 7 nos,<br>Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm<br>FRLS PVC insulated, copper conductor, single core cable including painting etc. as required.-(Note:<br>More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)- 1 no, <br> <br>Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length<br>(up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including<br>providing and fixing phenolic laminated sheet cover on the fan box etc. as required.- 1 no, <br>Installation of exhaust fan in the existing opening, including making good the damage, connection,<br>testing, commissioning etc. as required.- Up to 450 mm sweep- 2 nos, <br>Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution<br>board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din<br>bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)- 4 way (4 + 12),Double door- 1no, <br>Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for<br>inductive load of following poles in the existing MCB DB complete with connections, testing and<br>commissioning etc. as required. Single pole- 10 nos, <br><br>Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with<br>connections, testing and commissioning etc. as required. 32A- 1 no, <br>Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit<br>breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections,<br>testing and commissioning etc. as required. 40A- 1 no,<br>LIGHT FITTINGS-Supply of the following light fitting to complete with all accessories. LED bulkhead fitting<br>with minimum 700 Lmmen with IP65 IK 08 PROTECTION- 4 nos,<br>LIGHT FITTINGS-Supply of the following light fitting to complete with all accessories. LED 4 feet tube light fitting- 6 nos,<br>CEILING FAN-Supply of 1200mm 5star rated ceiling fan- 1 no,<br>EXHAUST FAN-Supply of 380 mm,single phase, heavy duty, exhaust fan- 2 nos.<br>
Sump Connection Works
100.15.2:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 150mm diameter Ductile Iron Double Flanged Pipes.
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
100.37.6.1:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.3:Cutting 150mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.4:Welding 150mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.5:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.1:In situ fabrication of M.S. pipes of size 350mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.10.2:Fabricating M.S. flanges of diameter 350mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.3:Cutting 350mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.4:Welding 350mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.10.5:Grinding cut and weld edges of 350mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.11.1:In situ fabrication of M.S. pipes of size 400mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.11.2:Fabricating M.S. flanges of diameter 400mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.11.3:Cutting 400mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.11.4:Welding 400mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.11.5:Grinding cut and weld edges of 400mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.
OD219794/2023-2024:Fabricating M.S. SHEET of diameter suitable for MS pipe of internal diameter 600mm using 16mm thick M.S. plate for providing dummy including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes end fabricated with 8mm thick M.S. plates.
Construction of Valve Chamber
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Supply of Pipes and Specials
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
OD219800/2023-2024: Ductile Iron Pipe Class K-9 flanges and welding 150 mm dia as per IS code.
OD219801/2023-2024: supply and fixing 150mm DI Wall casting pipe( puddle pipe)
OD219802/2023-2024:Supplying and fixing C.I man hole cover with frame for manholes:560 mm diameter ( heavy duty) the weight to be not less than 208 kg.
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.
100.98.488:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 350mm.
100.98.489:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 400mm.
OD219803/2023-2024:Supplying and fixing 400 mm DI wall casting pipe
OD219804/2023-2024:supplying and fixing 350mm wall casting pipe
Supply and erection of C.F pump set at Kepco
OD219806/2023-2024:Supply,erection, testing and commissioning of Energy efficient Level - 3, 250 KVA, 11KV/440V. 3phase, 50Hz,Dyn 11,. ONAN cooled , indoor type copper wound distribution transformers, with HV and LV side cable end box arrangements, on load tap changer with 17 tap positions having 5% to -15% variationsin1.25% steps with RTCC panel including first filling of oil etc. complete with all fittings as per IS 1180 L2 and Kerala Electrical Inspectorate norms and conforming to IS1180 ( Part 1 ). Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and externalshall be included in the cost of Transformer.
OD219807/2023-2024:MSB - Design, Fabrication, Supply, Erection, Testing and commissioning of - cubicle type, fully compartmentalized, free standing type switch boards, dust tight and vermin proof, fabricated out of 16 SWG CRCA sheet powder coated with approved colour. The switch boards should have a set of suitably rated TPN aluminium bus bars with specified current and fault level, insulated with heat shrinkable colour coded PVC sleeves and supported using DMC/SMC pillar or finger type bus bar supports. :- MSB INCOMER, 800A 50kA 4P microprocessor based EDO ACB with LSI protection with shunt trip and UV coil - 1nos, , Meters & Indications, MFDM (EM6400) -2set, RYB Indication lamps - 2set, 800/5A, CL-.5, 15VA, C.T. - 3No, , Relays - Under voltage relay 1 nos, Over voltage relay 1 nos, Restricted earth fault relay 1 nos, Ground Earth fault relay 1 nos, Electrical and mechanical interlock 1 set. OUTGOING - 400A 3P 50 kA microprocessor based MCCB - 4nos,
OD219808/2023-2024:Construction of 11KV 4 pole structure using RSJ pole 175x85mm, ISMC 75x40mm , PIN and disc insulator , copper conductor , lightning arrester earthing conductor, Surge Arresters, gang operated AB switch 2 nos and painting the structure .Construction of 4.5mm dia GI wire chain link fencing around the 4 pole structure , supply and spreading Stone Aggregate(single size): 40 mm nominal size inside the yard. Supply and fixing CTand PT unit and TOD meter. The completed as per the standard of IE rules.
OD219810/2023-2024:Supply erection commissioning and testing 5 Tone crane having upto 5.5M span, upto 14m length and upto 10 m lift and including all accessories and test certificate
Preparation of shop drawings necessary for work
OD219812/2023-2024:Providing detailed shop drawings, vetted by Wascon-KWA for the construction of pump house including all structural design, etc.... necessary for the construction and commissioning of the pump house based on soil test ,fixing of levels for the inlet and outlet necessary for the successful distribution and commissioning of pump house, Transmission and distribution system
Bidder Name
Renjumon
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1055223.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .