| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.4 LAccepted-AOC | ₹50.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.8 L+₹32,907.04 (0.65%)Rejected-AOC | ₹50.8 L+₹32,907.04 (0.65%) | L2 | Rejected-AOC L2 |
| 3 | L3₹51.0 L+₹51,129.83 (1.01%)Rejected-AOC SIMBARGAON BATABARI KOKRAJHAR ASSAM PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹51.0 L+₹51,129.83 (1.01%) | L3 | Rejected-AOC L3 |
Tender Value
₹50.4 L
EMD Value
₹1.0 L
Closing Date
7 Apr 2025, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar
Construction of Smart Classroom and 3 (three) nos Science Laboratory at Udalguri High Secondary School Udalguri District.
2025_BTC_43570_1
ACE-35/TECH/UDL(R and B)/IFB/18-19
Open Tender
Civil Works - Building
Item Rate
180 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
₹1.0 L
Yes
17 May 2025
18 Mar 2025
7 Apr 2025
18 Mar 2025
7 Apr 2025
18 Mar 2025
18 Mar 2025 - 7 Apr 2025
Amount
5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars
5.9. Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.3: Suspended floors, roofs, landings, balconies and access platform.
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering.....etc. 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand).
10.14. Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges....... etc. 10.14.3 Profile E 10.14.3.1 Fixing with adjustable lugs with split end tail to each jamb
10.11 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
10.30. Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 10.30.1 4.0 mm thick glass panes
10.16. Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 10.16.1 Hot finished welded type tubes 96mm x 48mm RHS @9.66 kg/m thickness 4.80m Rafter
12.65: Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless.....etc. 12.65.10.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
12.66: Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain....etc. 12.66.1 Precoated/mill finish aluminium Ridges plain (500- 600mm).
13.2 : 15mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement: 4 fine sand)
11.6: Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 11.6.1:18 mm thick
11.3. Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
12.52: Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel........etc. 12.52.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
9.96. Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: 9.96.1 300x16 mm
9.97. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 9.97.2 250x10 mm
9.100 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.100.1 125mm
9.101: Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 9.101.2 Twin rubber stopper
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers: 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 tr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
STAIR CASE 2.8. Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.5=1:3:6 (1 Cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars
5.9. Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 Lintels, beams, plinth beams, girders, bressumers and
5.9.3 Suspended floors, roofs, landings, balconies and
5.9.7: Stairs, (excluding landings) except spiral-staircases
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering.....etc. 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
11.6. Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement. 11.6.1:18 mm thick
Sri Khanan Goyari (BID ID -264948)
Sri Sanswrang Bargayary (BID ID -264950)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .