EE(Elect.)/CNZ
C-Block, defence Colony, New Delhi 110024
Improvement of Electrical installations and Engagement of Electrical wireman and Electric Beldar for day to day electrical maintenance at TB Hospital Nehru Nagar in ward no. 144 under Central Zone.
2026_MCD_295419_1
EE(Elect.)/CNZ/2026-27/34-01
Open Tender
Electrical Works
Percentage
365 days
Ward 144
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹28,000
23 Oct 2026
23 Oct 2026
30 Oct 2026
23 Oct 2026
30 Oct 2026
23 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C | 25 | Each | 1,704 | ₹42,600 |
| 2 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm | 260 | PM | 148 | ₹38,480 |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm | 280 | PM | 222 | ₹62,160 |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 6 sq. mm | 240 | PM | 326 | ₹78,240 |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire | 80 | PM | 621 | ₹49,680 |
| 6 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C | 120 | Each | 1,064 | ₹1,27,680 |
| 7 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | 1 | Each | 7,658 | ₹7,658 |
| 8 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 16 | PM | 50 | ₹800 |
| 9 | S.P. 15/16 A, one way modular switch, ISI marked | 15 | PM | 104 | ₹1,560 |
| 10 | 3 pin 5/6 A modular socket outlet, ISI marked | 18 | Each | 89 | ₹1,602 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 19.31 MB
Tendernotice_2.pdf
PDF • 5.90 MB
Tendernotice_3.pdf
PDF • 0.12 MB
BOQ_344344.xls
BOQ • 2.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .