| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹31.7 L+₹79,565 (2.57%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹33.7 L+₹2.7 L (8.87%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO REQUISITE CATEGORY NOT ENLISTED |
| Sl No | Description | Qty | Unit | om sai enterprises L1 | MAYUR ELECTRIC SERVICES L3 | Srinivash Engineers L2 |
|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 3 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period for insulation resistance testing, CRM testing, 3 pole timing testing with transportation under AMC and duly carring out servicing,overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any technical specification of 33 KV grade VCB current rating 400/630/800/1250 Amps (incoming/out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete servicing with facilitated operating features, and cleaning,overhauling,relay calibration and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. | 3 | Each Job | 15,000 ₹45,000 | 15,000 ₹45,000 | 10,000 ₹30,000 Lowest |
| 2.00 | Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 2 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period duly carring out servicing,overhauling, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom /Scheneider/L&T) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side operations in all respects and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. | 26 | Each Job | 6,000 ₹1,56,000 Lowest | 6,000 ₹1,56,000 Lowest | 6,000 ₹1,56,000 Lowest |
| 2.01Note for 1 & 2: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out thorugh a approved agency of any state/Central govt CEI (chief electrical Inspectorate) (iii) Engineer shall be consider repair/servicing duly reference taken from OEM drawings and tech specifications and service engineer will submit a service report and calibration certificate for each VCB. (iv) Any minor item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included in the quoted rates. (v) Failing attend the lodged complaint of any mode within 24 Hours will imposed penalty of Rs 1000/fault for each day cumulatively and same shall be deducted from his dues. | ||||||
| 3.00 | M&L for top up/replacement of transformer oil with new transformer oil in the existing transformer in yard 11/0.433 or 33/11 KV upto achieve the required level duly testing the old oil after filtration by the centrifuging machine measured under relevent items, if the oil not obtain deserved insulation levels replace the complete oil all as specified and as directed
Make :- Power Oil/ Transol/ GET | 700 | Ltr | 160 ₹1,12,000 | 160 ₹1,12,000 | 135 ₹94,500 Lowest |
| 4.00 | M&L for filteration, centrifuging and testing of PowerDist transformer oil by using centrifuging/ filteration machine for installed transformer, 33/11/0.433 KV at various sub station in order to achieve the desired dielectric strength of transformer oil as per relevent IS-1981 complete all as specified and as directed | 5,000 | Ltr | 15 ₹75,000 Lowest | 18 ₹90,000 | 22 ₹1,10,000 |
| 5.00 | M&L for disconecting the transformer connections and taking down from its foundation , transporting to work shop/MES store yard or site , drain out the oil from chamber complete opening of transformer and lifting the core and winding for cleaning of tank and core varnishing of winding for improvement of insulation resistance value reassembled the same duly refilling transformer oil and reconection the same on existing location or other location complete capacity of transformer upto 500 KVA Complete all as specified and as directed. | 5 | Each Job | 15,000 ₹75,000 | 17,000 ₹85,000 | 7,000 ₹35,000 Lowest |
| 6.00 | M&L for spray painting of transformer with synthetic enamel or recommended of capacity 50 to 100 KVA | 1 | Each job | 2,000 ₹2,000 Lowest | 2,200 ₹2,200 | 2,000 ₹2,000 Lowest |
| 7.00 | M&L for spray painting of transformer with synthetic enamel or recommended of capacity 163 to 250 KVA | 1 | Each job | 3,000 ₹3,000 Lowest | 3,500 ₹3,500 | 3,000 ₹3,000 Lowest |
| 8.00 | M&L for spray painting of transformer with synthetic enamel or recommended of capacity 315 to 500 KVA | 1 | Each job | 4,000 ₹4,000 Lowest | 4,200 ₹4,200 | 4,000 ₹4,000 Lowest |
| 9.00 | M&L for disconecting the transformer HT/LT connections and opening the top cover, conservator,breather unit complete, drain out the transformer oil from chamber upto deserved level complete and replace the top cover and vent pipe cork sheet and worn out washers, nut bolts, servicing the conservator and level gauge, welding,soldering the leakage spots using suitable welding metal if any complete and cleaning of conservator tank reassembled the same duly refilling transformer oil and reconection in all respects complete for capacity of transformer upto 500 KVA Complete all as specified and as directed. | 8 | Each Job | 3,500 ₹28,000 Lowest | 5,000 ₹40,000 | 3,500 ₹28,000 Lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
17 Jun 2026, 6:00 pmClosed
CWE (AF) Secunderabad
CWE (AF) Secunderabad
COMPREHENSIVE MAINT AND REPAIRS TO HT 33/11 KV MRS AND OTHER SUBSTATIONS, HT PANELS, HT VCB, TRANSFORMERS CONNECTED INFRASTRUCTURE AT DOMESTIC AREA UNDER GE (AF) BIDAR
2026_MES_768219_1
85675/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Bidar
₹68,000
Yes
30 Jul 2026
27 May 2026
20 Jun 2026
27 May 2026
17 Jun 2026
10 Jun 2026
27 May 2026 - 8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 3 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period for insulation resistance testing, CRM testing, 3 pole timing testing with transportation under AMC and duly carring out servicing,overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any technical specification of 33 KV grade VCB current rating 400/630/800/1250 Amps (incoming/out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete servicing with facilitated operating features, and cleaning,overhauling,relay calibration and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. | 3 | Each Job | 2.25 | ₹6.75 |
| 2 | Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 2 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period duly carring out servicing,overhauling, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom /Scheneider/L&T) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side operations in all respects and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. | 26 | Each Job | 4.25 | ₹110.5 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
85675TENDERPDF.pdf
Tender Documents • 0.68 MB
BOQ_860292.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .