Tender Value
₹5.8 Cr
EMD Value
₹6.1 L
Closing Date
17 Sept 2022, 6:00 pmClosed
CE NW Kochi
Kattaribagh Navel Base P.o Kochi -4
COMPLETION OF INCOMPLETE WORKS OF SEWAGE TREATMENT PLANT AT SMA NAVEL BASE KOCHI
2022_MES_546519_1
890472
Open Tender
Civil Works
Lump-sum
365 days
Kochi
As per tender Documents
9 documents required · 9 mandatory
₹3,000
GE (P) NW Kochi
₹6.1 L
Yes
3 Nov 2022
20 Aug 2022
19 Sept 2022
21 Aug 2022
17 Sept 2022
3 Sept 2022
22 Aug 2022 - 30 Aug 2022
Amount
LIST OF WORKS
Schedule A Part I ( to Part XI)
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' Part-III (Internal Water Supply)
Total amount of Sch 'A' Part-IV (Internal Electric Supply)
Total amount of Sch 'A' Part-V (External Electric Supply)
Total amount of Sch 'A' Part-VI(External water supply)
Total amount of Sch 'A' part-VII (Fencing and Gate)
Total amount of Sch 'A' part-VIII (Road/Path
Total amount of Sch 'A' part-IX (Sewage disposal)
Total amount of Sch 'A' part-X (Area drainage)
Sch 'A' Part- XI (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Completion of Incompleted works of Sewage treatment plant of capacity 750 Cum /day based on moving bed bio reactor aerobic attached growth technology including tertiary treatment of waste water to the tune of 10% quantity to be recycled for arboriculture, stadium and MT wash purpose which includes all requisite all iner connecting pipes, cables, valves and any Misc item required if not mentioned separately in BOQ with and including following items complete all as specified and shown on drawings (Note:- (i)Pile foundation work incl ring beam shall be measured and paid separately (ii)Completed works are enclosed as Annexue 3 for guidance only.. a) Inlet Work consist of Stilting chamber, screen chamber and grit chamber,
b) Equalzation tank c) Moving Bed Bio Reactor tank. d) Clarifier, e) Chlorine Contact Tank, f) Treated Water Sump. g) Sludge Sump. h) Sludge Pressure Unit with Poly propelene filter Press, PBC Hydraulic closing device with operating pressure 5Kg/ cm2-01 No, j) Mechanical bar screen-02 Nos of following technical specification:-(i) clear spacing between the screen flats-20mm(clear). (ii) Angle of inclination-60degree to 80 degree to horizontal. (iii) Flats of screen-Sqmm,70mm to 10mm thick (stainless steel). (iv) Operated by-NA Motor driven mechanism, (k) Fine screeen of following technical specification:- (i)Clear sapacing between the screen flats-6mm,(ii) Angle of inclination-Degree 45degreee to horizontal,(iii)Material of constructionof screen-NA,stainless steel-316,
(l)Manual screen chamber of following technical specification: (i) Clear spacing between the screen flats-20mm(clear),(ii)Angle of inclination -deegree 75 degreee,(iii) Flats of screen -Sqmm,70mm to 10 mm thick (SS-316), (m)Air blower with motor,twin lobe type,capacity-650cum/Hr,Pressure 0.55Kgs/Cm2,Blower model Expo-II for Equalisation tank(15 HP) complete all as specified of following technical specification-02 Nos (i) No of air blowers-03 Nos (2 Working+ 01 standby),(ii)Type-Twin lobe Rottary,(iii) Capacity-650Cum/Hr,(iv)Pressuree-0.55Kg/Sqcm,(v) Air blower drive-15KW/1440 RPM,(vi) Drive Make-Kirloskar/Crompton,(vii)Blower,Model-Expo-II,Make of blower-Everest/Usha/Kirloskar/KAY International/Inger soil-Rand
(n) Air blower with motor,twin lobe type capacity -20HP,pressure 0.55Kg/Cm2 Blower model Expo-II for Equalisation tank(15 HP) complete all as specified of following technical specification-03 Nos: (i) No of air blowers-03 Nos (2 Working+ 01 Standby),.(ii)Type-twin lobe rotary,(iii)Capacity-20HP,(iv)Pressure-0.55 Kg/Sqcm,(v)Air blower drive-15KW/1440RPM,(vi) Drive make-Kirloskar/Crompton,(vii)Blower,Model-Expo-II,for MBBR,
(o)Media for MBBR reactor complete all as specified of following technical specification-02 Nos: (i)Media type--Non clog ,Floating,(ii)Media make offered-Ion,(iii)Material of construction-PP, (iv)Surface area-400 Sqm,(v) Density-0.93 Gm/CC,(vi)Media quantity-63Cum (p) Reactor aeration grid in stainless steel of following technical specification-02 Nos: (i) Type-Coarse Bubbing,(ii)Capacity-7.50Cum/Hr,(iii)Make-Cool deck/welcome/Cap international,(iv)No of diffusers -88 Nos (q)Rotating blade with accessories of following technical specification-01 Lot:- (i) No of unit -One unit having a combined average design flow of 0.75MLD,(ii)Type-Cular with mechanical scrapper,(iii)Surface loading at average flow-15M3/M2/day(Max),(iv)Surface loading at peak flow-25-50M3/M2/day,(v)Solid loading at average flow-10-120M3/M2/Day,(vi)Solid loading at peak flow-170M3/M2/day,(vii)HRT-2.5Hour,(viii)Floor slope-1 in 12,(ix)Side water depth-2meter,(x)Free board-500mm,(xi) Diameter of feed well-20% diameter of tank (xii) Level of immersion feed well-1.5m(Min)below water surface in the tank (r) Chemical dosing pump for CCT of following technical specification-02 Nos:- (i) Numbers-2 Nos (1 Working+1 Stand by),(ii) Type-Metering/Diaphragm,(iii)Capacity-50LPH,(iv)Head-4 Kg/Cm2,(v)Materials-PP,(vi)Make-Asia LMI matachemprecidose,(vii)Hrt-30mins contact time,(viii)Average chlorine dosage-As per design-but not more than 5ppm,(ix) Capacity of chlorinator-3.2 M3/Hour,(x)Chlorinator-Vaccum type injection dosing -high quality-like penvault,(xi) Type-Square,material-RCC structure M30.
Ductile iron flanged pipe 250mm dia in standard length confirming to IS 8329-2000 pressure pipe class K-9 laid in excavated trenches including testing and commisioning all as specified and directed
Ductile iron flanged pipe 150mm dia in standard length confirming to IS 8329-2000 pressure pipe class K-9 laid in excavated trenches including testing and commisioning all as specified and directed
Ductile iron flanged pipe 100mm dia in standard length confirming to IS 8329-2000 pressure pipe class K-9 laid in excavated trenches including testing and commisioning all as specified and directed
MS Pipe heavy grade of 300mm dia with all fittings laid in floors or walls for MBBR & clarifier complete all as specified
RCC NP-2 Pipe of 300mm dia with all fittings for MBBR, Clarify and sludge complete all as specified.
Centrifugal pump set, pipe size , suction and delivery 80x 80 mm, 500 LPM at 15mtr head electric driven 3 phase 415 volts including PVC ball type foot type valve at suction side and one No 80mm dia butterfly valve at discharge side including necessary foundation suitable DOL srarter , cable from starter to motr etc all as specifed and directed.
Non clog submersible pump set 15 HP , RPM 1450, frequency 50+ 3% Hz volt 415 + 6%-10% enclosure IP-68 Tank and clarifier complete all as specified.
Non clog submersible pump set 15HP with electric driven 415volts , RPM 1450 frequency 50+ 3% Hz volt 415 + 6%-10% enclosure IP-68 insulation class F inclusive of Submersible cable and starter for equalisation tank and clarifer of Make -KSB /Aqua /Kay International /Inger soil -Rand complete all as specified including the following :-for peRunning meterissible solid 40mm of capacity 12-14mtr head 10LPS discharge including following:-
(a) Pump with motor with required flexible copper cable from control panel to motor.(b) Cast Iron pedastal coupling(c) Cast Iron Delivery Bend(d) 100mm dia PNI class Non return valve(e) Cast Iron Dismantling Joint.(f) 100mm dia delivery pipe ( DI Flanged pipe clas k-9 of lengh from 6 to 10 mtr/pump)(g) 50mm MS galvanised guide pipe from 6 to 10 mtr / pump)(h) Liquid level sensor and control for fully automatic operation of pump set.
HDPE pipe 100mm outer dia, PE-100 ISI marked including fittings/ special etc for suction and delivery all as specifed.
Ductile Iron flanged pipe 200mm dia in standard length conforming to IS 8239--2000 pressure pipe class K-9 laid in excavated trenches including testing and commissioning all as as specified and directed.
Construction of valve chamber 0.80mx0.80Mx 0.80m (0.80M between the inner edge of the valve chamber and 0.80M height from ground level ) with brick and masonary in CM 1:6 , 10mm thick in cement mortar externally upto 15cms below ground level CM1:6 including provision of MS sheet cover 3mm thick with flat iron 25x3mm frame and bracing , locking arrangement incl. necessary earth work, excavation in any type of soil and applying two coats of synthetic enamel paints over a coat of red oxide primer to steel surfaces complete all as specified.
Diesel Engine driven generating set 100KVA 415volts 3 phase, 4 wire complete with foundation AMF panel with necessary meters and accoustic enclosure complete all as specified.
Double compression copper stainless steel gland for fixing aRunning meteroured cable in panel, of size 95 Sqmm , 3.5 core all as specified.
XLPE Cable insulated Screened PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty 1100V grade with standard aluminium conductor of size 3.5 core 95 Sqmm all as specified
XLPE Cable insulated Screened PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty 1100V grade with standard aluminium conductor of size 3.5 core 95 Sqmm including cable glands and cable lugs, nuts& bolts etc required at site complete all as specified.
All as per Item No 29 herein before but 3 core 16Sqmm
All as per Item No 29 herein before but 4core 10Sqmm C58
All as per Item No 29 herein before but 2core 6Sqmm C58
Design, fabricate, supply and installation of factory made LT Panel board , CPRI approved, indoor type , front operated dust and vermin proof made of 3mm thick CRCA sheet having protection IP-54 with necessary frame made out of 40x40x6mm angle iron sections duly powder coated over a coat of metal primer with locking arrangements with 500 Amps rated TPN aluminium bus bar, including wiring with suitable size copper cable and PCC 1: 3: 6 type C1 foundation /PCC pillar complete all as specified with and including following accessories : (i) on load change over switch 4pole 415 volts ,200Amps -01 No (ii) MCCB 415 V 200 Amp 25KA Four pole -01Nos incoming (iii) MCCB 415 V 100 Amp 25KA Four pole -01Nos (outgoing) (iv) MCCB 415 V 125 Amp 25KA Four pole -01Nos(outgoing) (v) MCB 415 V 16 Amp 10KA Four pole 'C' series 02 Nos(outgoing)(vi)MCB 415 V 16 Amp 10KA Two pole -02 Nos(outgoing) (vii)Digital Voltmeter 0-500volts-01 No (viii) Digital ammeter 0-500Amps -01Nos(ix) Phase indicator lamp LED Type RYB -01Set
Point wiring using approved color coding as per IS (Red, Black and Green for single phase circuit ) multistranded copper conductor 1.5Sqmm nominal cross -sectional area , single core PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked with valid CML No in and including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floors etc ISI marked including modualr GI flush (Same make of approved switch and socket ) including PVC nominal cross sectional area single core FRLS cable as earth continuity condiuctor to common earth and connection to earth dully complete all as specified and directed at site for the following :(Note switch and socket to be measured and paid for 5/6 amps one way switch.
One light/ceiling fan /exhaust fan point controlled by one 5/6 amp one way switch
One socket outlet, three/five pin, 5/6amp independent controlled by one 5/6 amp one way switch or switch/socket combination 5 amps, 5pin
Point wiring using approved color coding as per IS (Red, Black and Green for single phase circuit ) multistranded copper conductor 1.5Sqmm nominal cross -sectional area , single core PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked with valid CML No N o in and including heavy duty PVC concreled conduict and conduit accessories concealed in wall/roof/floors etc ISI marked including modualr GI fulsh (Same make of approved siecthy and csocket ) including PVC nominal cross sectional area single core FRLS cable as earth continuity condiuctor to common earth and connection to earth dully complete all as specified at site for the one 3/5 pin 15/16 amps socket outlet independent. :(Note switch and socket to be measured and paid seperately)
LED tube light fitting 1x10 watt with white acrylic cover complete (Cat No LCL-10-CDL make CG or equivalent Havells/philips /Bajaj)
LED tube light fitting 1x18 watt with white acrylic cover complete (Cat No BCLSB18WH make Bajaj or equivalent Havells/philips /CG)
Exhaust fan 300mm sweep copper wound having minimum 5 star rating including fixing and connection up complete with and including three core flexible PVC insulated multi strandard copper conductor cable of size 0.5sqmm from ceiling rose/connector to fan.
Exhaust fan 450mm sweep copper wound having minimum 5 star rating including fixing and connection up complete with and including three core flexible PVC insulated multi strandard copper conductor cable of size 0.5sqmm from ceiling rose/connector to fan.
Ceiling fan1400mm sweep copper wound having minimum 5 star rating including fixing and connection up complete with and including three core flexible PVC insulated multi strandard copper conductor cable of size 0.5sqmm from ceiling rose/connector to fan.
Street light fitting integral LED 45 watt pressure die cast aluminium houding heast resistance toughtened glass with frame having IP -66 protection (Cat No LSTO-45-CDL Make CG or equivalent in Havells/phililps/Bajaj with and including bracket fabricated out of GI pipe 40mm dia medium grade bend to shape and fixed with MS clamps fabricatyed out of MS flat (FE410-W Gde E250) quality A ) of size 40 x 5 bend to shape (in two halves) -2 sets complete all as specified and directed at site and including one run of twin core cable PVC insulated from fitting to FRP Pole mounting box drawn in non metallic regid PVC conduit complete all as specified and directed.
Sub main wiring with 4 Sqmm two single core (for phases and neutral ) using multistanded copper conductor PVC (F.R insulated unsheathed with and incl 2.5 Sqmm insulated unsheathed PVC insulated multistranded copper conductor connected to common earth duly drawn in PVC conduit (ISI mark with accessories. (Note : Two runs of 4Sqmm and one run of 2.5Sqmm and one run of PVC concealed conduit shall be measured as one run only)
Short Body CP bib cock with wall flange )Cat No CQT- 23047) Make: Jaguar or equivalent in other make mentioned in list of manufacturersschiender/L&T
CP 2 way bib cock with adjustable wall glange (CQT- 23083) Make: Jaguar or equivalent in other make mentioned in list of manufacturers
Concealed CP stop coak with adjustable wall glange (CQT-23083) Make: Jaguar or equivalent in other make mentioned in list of manufacturers
CP Angle cock with wall flange (cat No CQT-23059) Make: Jaguar or equivalent in other make mentioned in list of manufacturers
CP Health fucet 1 mtr flexible tube with wall hook complete (Make : Jaquar cat No ALD -CHR-565 OR EQUIVALENT OF Make Cera/Parryware or equivalent in other make mentioned in list of manufacturers
PVC Encpsulated foot rests 263 mm length, 164 width, 25 mm thick all as specofied.
Heave duty SFRC Manhole cover with frame out dia 860 mm, Height 165 mm and weight 105 Kg and inner dia 560 mm, Cover specification outer dia 710 mm, height 90 mm Weight 90 Kg all as specified.
Use and waste of timbering as planking and shuttring for excavation up to 1.50 mm deep
Use and waste of timbering as planking and shuttring for excavation up to 3.00 mm deep
Use and waste of timbering as planking and shuttring for excavation up to 5.00 mm deep.
S& Fix shower rose with shower arm CP swivel of bore 15 mm face dia 125mm,
MAINTENANCE AND OPERATION OF SEWAGE TREATMENT PLANT
Supply only Alum crystal approved quality
Supply only Lime of approved quality
Supply only Chlorine gas
Provn of Services for operation of sewage treatment plant installed under this contract of capacity 750Cum/day including all supporting equipment such as pumps, motors, panels, DG set etc in 03 shifts of 08 hours each(round the clock including sunday/holidays)by deploying technically qualified person including supply of all consumable(except diesel, chlorine, alum & lime)for the First year from actual date of completion(i.e during defects liability period) as specified nd directed by Engineer-in-Charge. Following items shall also be deemed to be included in the quoted rates.
Note (i) The contractor shall employ one operator per shift the operator shall be qualified & experienced in field and experience not less than 2 yrs in the same field.(ii) Cost of periodical maintanance of vrious equipment/parts shall be deemed to be included in quoted rates of respective items.(iii)Samples of effluent shall be collected from the outlet twice in a month as directed and got tested in a lab approved by State Pollution Control Board.(iv) The contractor shall strictly follow the operation and maintenance manual of the plant as well as dosage of chemical prescribed by testing agency.
(v)Periodical cleaning and removal of sludge from screen well, collection well, contact aeration tank, sludge aeration tank, settling tank, sludge drying beds, bar screen, screen through etc.(vi)Mixing chemical to maintin desired quality of end product of system.(vii)To maintain ll working plce and area neat and clean.(viii)The Log sheet must be maintain by the contractor as directed by the Engineer-in-Charge.
(ix)Diesel for running DG set will be arranged by department and log sheets for running the DG set shall be maintained by contractor and submitted monthly. The container for storage of Diesel nd transportation from MES store yard to site shall be the responsibilty of contractor and cost for the same shall deemed to be included in the item rates. (x) The maintenance of the plant during the defect liability period is deemed to be included in the quoted rate of STP vide item No 14 herein before.
Provn of Services for operation and maintenance of sewage treatment plant installed under this contract of capacity 750Cum/day including all supporting equipment such as pumps, motors, panels, DG set etc in 03 shifts of 08 hours each(round the clock including sunday/holidays)by deploying technically qualified person including supply of all consumable(except diesel, chlorine, alum & lime)for the second year after completion(i.e first year after the defects liability period) as specified nd directed by Engineer-in-Charge. Following items shall also be deemed to be included in the quoted rates.
Provn of Services for operation and maintenance of sewage treatment plant installed under this contract of capacity 750Cum/day including all supporting equipment such as pumps, motors, panels, DG set etc in 03 shifts of 08 hours each(round the clock including sunday/holidays)by deploying technically qualified person including supply of all consumable(except diesel, chlorine, alum & lime)for the third year after completion(i.e second year after the defects liability period) as specified nd directed by Engineer-in-Charge. Following items shall also be deemed to be included in the quoted rates.
Notes for Item Nos 59 and 60 (i) The contractor shall employ one operator per shift the operator shall be qualified & experienced in field and experience not less than 2 yrs in the same field.(ii) Cost of periodical maintanance of vrious equipment/parts shall be deemed to be included in quoted rates of respective items.(iii)Samples of effluent shall be collected from the outlet twice in a month as directed and got tested in a lab approved by State Pollution Control Board.(iv) The contractor shall strictly follow the operation and maintenance manual of the plant as well as dosage of chemical prescribed by testing agency.
(v)Periodical cleaning and removal of sludge from screen well, collection well, contact aeration tank, sludge aeration tank, settling tank, sludge drying beds, bar screen, screen through etc.(vi)Mixing chemical to maintin desired quality of end product of system.(vii)To maintain ll working plce and area neat and clean.(viii)The Log sheet must be maintain by the contractor as directed by the Engineer-in-Charge.
(ix)Diesel for running DG set will be arranged by department and log sheets for running the DG set shall be maintained by contractor and submitted monthly. The container for storage of Diesel and transportation from MES store yard to site shall be the responsibilty of contractor and cost for the same shall deemed to be included in the item rates.
United Sales Corporation
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .