Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC H NO 1 77 1 VIJAYANAGARAM COLONY KONDAIEGUDEM POST MANUGURU 507117 BHADRADRI KOTTAGUDEM DIST TELANGANA STATE | BHADRADRI KOTHAGUDEM | TELANGANA | 507117 | L1 | Accepted-AOC L1 STATUS | |
| 2 | Rejected-Technical 3 216 OPP H W P M COLONY GATE ASWAPURAM BHADRADRI KOTHAGUDEM DIST TELANGANA STATE 507116 | ASWAPURAM | BHADRADRI KOTHAGUDEM | TELANGANA | 507116 | - | Rejected-Technical Technically Not Qualified |
Tender Value
₹16.3 L
EMD Value
₹32,620
Closing Date
30 Jan 2024, 6:45 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager
General Manager, HWP(M)
Preventive and Breakdown maintenance of 11 kV Over Head Line connected between ESS1 of HWPM Colony and 2 Pole Structure at HWPM Plant X Road and restoration of overhead line between 2 pole and 4 pole structures.
2024_HWB_788910_1
HWPM/EU/Col/11KV/2023/NIT DT.30/12/2023
Open Tender
Electrical Works
Item Rate
730 days
Works/ HWP(M) Colony, Gouthaminagar, Aswapuram
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹32,620
13 Jun 2024
6 Jan 2024
7 Feb 2024
6 Jan 2024
30 Jan 2024
6 Jan 2024
6 Jan 2024 - 16 Jan 2024
Amount
Removal of the vegetation/grass between four Pole structure & colony receiving end.
vegetation / grass and plants / small trees up to a height of 3 mtrs.
Trees of any girth up to & above a height of 5mtrs etc.
Complete physical checking and carrying out the general maintenance once in a year for the 33/11 kV over head line between plant and colony.
Rectification of deficiencies in the line based on the check list prepared during the physical checking monthly line patroling and against break down as and when required.
Supply & Replacement of 33 Kv disc Insulators string made by Polymer (FRP) complete with galvanised strain clamps, bolts, nuts, washers etc in place of damaged string insulator including disconnecting the conductor from damaged disc insulator at cut point. stringing back the disconnected conductor after replacement of new disc insulator with suitable gripper & pin to the minimum sag level including making the connection with suitable binding wire etc as required.
Supply & Replacement of 33 kV Polymer (FRP) pin Insulator in place of damaged insulator including pin bolt with double nuts, washer etc as required as per the specification.
supply & Replacements of one set (3 No.s) of 9KV lighnting arrester in place of damaged ones.
Disconnecting damaged conductor / conductor with over sag from the insulators at cut points and making the joints and re connecting repaired conductor.
Straightening the tilted poles by excavating the soil to required depth after disconnecting the pole from the line conductors and then straightening the pole.
Greasing of all moving parts of AB switches.
Removing the damaged pole by excavating the pit around the pole, after disconnecting the cross arm, insulators, line conductors and refilling the pit.
Supply & Erection of New RCC of grade 1:2:4 for 33KV line pole of Tappered in shape with 460mm x 150mm size at bottom and 150mm x 150mm size at top (Reinforcement for RCC pole to be provided as per the NPDCL speccifications) with a over all length of 9.1mtr.
Supply & Erection of Stay set complete (galvanised) with 19/20mm dia X 1.8mtr long stay rod.
Carring-out the total 11KV Overhead line patroling once in a month from colony to 2-pole structure for listing-out the deficiences in the line.
Replacement & erection of new RCC poles inplace of Existing Old/Obsolete RCC Pole at cut points with set of 4 Poles having length of 9.1 mts. and 460mm width , 150mm thickness at bottom and 150x150mm size at top for main pole supported with 4 nos. Shut Poles positioned opposite to pulling force of line conductors (as counter force) in a pit of 0.6x0.6 Mts size and depth 2/1.75 mts. with 1:3:6 PCC etc., including fixing the cross arm, insulators, connecting the line conductor to the Insulator strings etc., as per the standard procedure.
Supply and replacing exisiting old obsolete Y phase clamps with new T shape galvanised stand with 2 nos. clamps and stainless stell studs with double washers and nuts
Supply and laying of 50 sq.mm ACSR conductor
Carring-out the total 11KV Overhead line patroling once in a month from 4-pole structure to 2-pole structure for listing-out the deficiences in the line
Providing and laying the 1:3:6 PCC at 4pole structure
Supply and installation of 33kV MS Cross Arms.
Supply of 1 nos. of 21.5 Feet Aluminium Telescopic ladder.
Supply Electrical Varnish Insulation spray.
Supply one 22inch Trees Trimming machine
Supply 50 sq.mm ACSR Rabbit Conductor.
Supply & Replacements of one set (3 No.s) of 30KV lightning arrester in place of damaged ones.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .