Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹55.5 L+₹5.6 L (11.2%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹57.7 L+₹7.8 L (15.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹58.5 L+₹8.6 L (17.2%)Rejected-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L4 | Rejected-AOC L4 | |
| 5 | L5₹60.4 L+₹10.5 L (21.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
3 Oct 2023, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
SPECIAL REPAIRS TO MARRIED ACCOMMODATION BLDG NO P-36 AND P-37 AT TS(K) UNDER AGE B/R ALWAYE.
2023_MES_617795_1
8245/E8
Open Tender
Civil Works
Item Rate
180 days
ALWAYE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹97,000
Yes
12 Dec 2023
8 Sept 2023
5 Oct 2023
8 Sept 2023
3 Oct 2023
26 Sept 2023
8 Sept 2023 - 25 Sept 2023
Amount
Dismantling of floor hearth and wall tilling including mortar bedding removing serviceable tiles to store and rubbish off the premises as directed by the Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
Material & Labour for ceramic coloured matt finished tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floor including 15mm thick screed bed in CM 1:6 set and jointed and pointed in white or coloured cement to match the tile complete all as specified and as directed.
Material & Labour for ceramic coloured glazed tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting/dado with and including 10mm thick backing coat in CM 1:4 set and jointed and pointed in white or coloured cement to match the tile complete all as specified and as directed.
Material & Labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor including 15mm thick screed bed in CM 1:6 set and jointed and pointed in white or coloured cement to match the tile complete all as specified and as directed.
Material & Labour for ceramic coloured glazed tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirting/dado with and including 10mm thick backing coat in CM 1:4 set and jointed and pointed in white or coloured cement to match the tile complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry bedded in any mortar complete all as specified.
Material & Labour for Granite tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with and including 15mm thick screed bed in cement mortar (1:6) complete all as specified.
Material & Labour for Granite tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in skirting/dado with and including 10mm thick backing coat in CM 1:4 complete all as specified.
Material & Labour for water proofing treatment to existing RCC roof slab including preparation of surfaces parapet comprising with the following course of treatment/ specification from bottom to top: - (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) One layer of C polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.0 Kgs per Sqm, reinforced with non woven polyester fabric of weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (c) Laying of Standard APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) complete all as specified and directed by Engineer in Charge. Notes:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturer’s instruction.
Supply & Fix hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement, including dismantling of Brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer in Charge.
Material & Labour for 10 mm thick plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, add WPC @3% of cement weight including WPC, finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Polymeric membrane will be measured and paid separately)
Dismantling Single layer Mangalore pattern or similar tiles in roofing bedded in lime or cement mortar including removal of vegetation nails etc complete all as specified and as directed by Engineer in Charge.
Material & Labour for Roof tiles, Mangalore pattern, interlocking at side joints, laid over tiling for eaves tiles or verges, bedded in lime mortar 1:3 or cement mortar 1:6 to old brick-work or masonry with any height of roof , including necessary scaffolding etc complete all as specified and as directed by Engineer in Charge
Material & Labour for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
Supply & Fix Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engineer in Charge.
Supply & Fix Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self Tapping screws as specified complete all as specified and as directed by Engineer in Charge.
Material & Labour for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) as slab support on wall, beams, column in floor, roof, laundry, balconies, shelves etc, complete all as specified and as directed.
Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material & Labour for Mild steel TMT bars 5mm dia and over, cut to length, bent to shape required, up to and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in dense or soft soil complete all as specified and as directed by Engineer in Charge
Material & Labour for Cement concrete type D2 type 1:4:8 (40 mm graded aggregate)in foundations, filling and mass concrete post holes filling etc complete all as specified and as directed by Engineer in Charge.
Supply & Fix Steel work in tubular trusses, I sections, angles, Flat /plate and Tee sections etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 including one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
Supply & Fix wind ties for roof, cladding angle/ flat sections including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Grade E-165 complete all as specified and as directed.
Taking down shutters exceeding 1 Sqm not exceeding 2 Sqm each and refixing with same opening after Re securing or easing &adjusting /cutting with a required repair complete all as specified and as directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (without taking off shutter from the frame) and removing material from the site complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (without taking off shutter from the frame) and removing material from the site complete all as specified and directed.
Taking down shutters exceeding 1 Sqm not exceeding 2 Sqm each.
Material & Labour for 30 mm thick well seasoned 2nd class hard wood glazed and skeleton shutters as per open rebated and prepared to receive glass, gauge etc without sash bar, edge of framing plain chamfered or rounded mitered beads for securing glass any numbers as specified in clause 8.24 (a) of MES Schedule Part-I Section-8complete all as specified and directed.
Material & Labour for 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and as directed.
Material & Labour for 2nd class hard wood well seasoned plain solid straight chowkhats framed wrought framed, rebated on the solid, round or chamfered put together with glue and pinned at joint and fixed in wall complete all as specified and directed.
Supply & Fix powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
Supply & Fix Powder coated aluminium (sliding type) (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply & Fix Powder coated Anodised aluminium window and ventilator shutters fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and directed.
Supply & Fix Powder Coated Anodised aluminium window and ventilator shutters with frame , side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
Supply & Fix Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as per requirement and direction of Engineer in charge.
Supply & Fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc, complete all as specified and directed.
Supply & Fix in repairs Fancy type Drapery rods, powder coated aluminium of 20 to 25 mm size with fixing brackets, stops, rollers etc, complete all as specified.
Supply & Fix in repair to 20mm dia Stainless steel Curtain Rod fixed with brackets , Knobs ,finial of 2 pieces ( Each side ) with necessary screws , plugs etc complete all as specified and directed.
Supply & Fix 1mm thick sinks made of stainless steel kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size of 495mm x 420mm and bowl size of 410mm x 330mm x 160mm complete all as specified and as directed.
Supply and fix in repairs in in trenches/walls/ceiling high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 16 mm dia complete all as specified and directed.
All as per item No 42 here-in-before but of size 20mm dia
All as per item No 42 here-in-before but of size 25mm dia
Supply and fix in repairs CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe including necessary fittings and taking down old one complete all specified and directed.
All as per item No 45 here-in-before but of size 20mm dia
Supply & Fix 1000 Litres capacity Rotational mould polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position including taking down unserviceable tank complete all as specified and directed.
Supply & Fix in repairs 25 mm bore brass ball valve high pressure with polythene float and flynut suitable size and fly nut including taking out old one complete all as specified and directed.
Taking down eaves gutters and rainwater pipes, drain pipes etc (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, complete all as specified and as directed.
Supply & Fix PVC (SWR or Drain ) pipes, single socketed, in any length, with rubber rings 75mm dia bore fixed with necessary clamps complete all as specified and as directed.
Supply & Fix 110 mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified.
Supply & Fix PVC (SWR) floor trap up to 75mm outlet , plain with grating including jointing with solvent cement including set in Cement Mortar ( 1:4 ) complete all as specified.
Supply & Fix in repair in 32mm bore brass CP Waste coupling for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair Stainless steel plate rack of size 900x750x250mm complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed complete all as specified and as directed.
Supply & Fix in repair to Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed
Supply & Fix in repair to Vitreous China wash down water closet pan (European type) with P or S trap, snow white or white colour, fixing bolts, including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc complete, excluding flushing cistern and flush pipe including seat cover as in repair complete all as specified and as directed.
Supply & Fix in repair to vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed.
Supply & Fix in repair to brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
Supply & Fix in Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed.
Supply & Fix in Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and as directed.
Supply & Fix in repair to Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and as directed.
Supply & Fix in PVC connections 15mm size with PTMT nuts of length 600mm long complete all as specified and directed.
Supply & Fix Grating square fitting of size 150mm made in two parts for smell and mosquito proofing with minimum 25 mm water seal of PTMT (Minimum weight 85gms) complete all as specified and directed
Supply & Fix in repair to Vitreous china wash hand basin white flat back of size 550x400 mm ,including brackets, waste coupling and waste pipe, or fixed with existing platform surfaces with sealant with white cement etc complete all as specified and directed.
Supply & Fix in repairs, PVC valve less,10 litre capacity, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Supply & Fix 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
Supply & Fix in repair brass chromium plated shower rose 125mm size with shower arm 15mm bore including 45 degree bend with flange complete all as specified and directed
Supply & Fix in repair to 15mm bore fancy type Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified directed.
Supply & Fix in repair to CP 15mm bore Bib taps, Fancy type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer in Charge.
Supply & Fix in repair to 15mm bore CP fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified directed.
Supply & Fix in repair to 15mm bore swan neck type Sink tap Fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified directed.
Supply & Fix in repair Fiber Glass reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness, The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat, Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs, The frame shall be covered with fiber glass from all sides, MS stay shall be provided at the bottom to steady the frame, including taking down old shutters, complete as specified by the manufacturer instruction and as per directions of Engineer-in-charge.
Supply & Fix in repair 30 mm thick Glass Fibre Reinforced Plastic (FRP) paneled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frame accessories like a door handle 02 Nos , Min 3 Hinges and with Both side Locking arrangements etc, (Tower Bolts) complete fittings ,including to existing door frames with / New Door frame etc complete as specified by the manufacturer instruction and as per directions of Engineer-in-charge.
Demolition of unreinforced cement concrete of any description as in coping, chimney walls etc over compound wall complete all as specified and directed.
Material & Labour for Plain Cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate in roof and parapet wall junction ,roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, filling rails embedded section ,hold fast etc including form work complete all as specified and as directed
Demolition of unreinforced cement concrete of any description complete all as specified and directed.
Material & Labour for 50mm thick Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in sub base, sub floor, floor and paving etc, surfaces finished of concrete flooring with including provision of necessary construction joints complete all as specified and directed.
Material & Labour for Hard core(broken boulders and stones) of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick broken stone or boulders , water and rammed to a true surface complete all as specified and as directed.
Material & Labour for cement concrete D2 1:4:8 in foundations (40 mm graded aggregate) filling and mass concrete complete all as specified and as directed.
Material & Labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, or 30cmx30cmx25mm thick or PCC deco tiles set, jointed and pointed in neat cement slurry in floors with grey cement & pigments with Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed by Engineer in Charge.
Demolition of brick work/solid block work built in cement mortar including all quoins, pillars etc, complete all as specified and as directed
Material & Labour for Pre-cast cement concrete block masonry with solid block type C1, (1:3:6) (20 mm graded aggregate) setting in CM 1:6 complete all as specified and directed.
Material & Labour for precast cement concrete solid building block or slabs type C1, 1:3:6 (20mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in CM 1:4 complete all as specified and directed.
Taking down cement plaster or brick or stone wall including raking out joints, hacking for key scrubbing down with water complete all as specified and directed.
Material & Labour for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 on walls even and smooth without using extra cement complete all as specified and directed.
Material & Labour for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 on walls even and smooth without using extra cement complete all as specified and directed.
Material & Labour for Rendering 10 mm thick on ceiling surfaces in CM 1:3 even and smooth without using extra cement complete all as specified and directed.
Material & Labour for preparation of existing flat or sloped roof surfaces & wall surfaces including racking out with loose dust ,grease old flake and chips etc and rrack filling with Dr Fixit Crack 'X' paste and wet the wall/roof surfaces prior to coating to Dr Fixit prime seal (50% Dilution) and ensure dry for 4 to 5 hour as per Manufacture instructions and finishing the roof/sloped surfaces gaps ,undulations filled with Cement Mortar in 1:4 or along with PCC type 1:2:4 B-0 complete all as directed by Engineer in Charge.
Material & Labour for forming jambs with Cement mortar in 1:4 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified and as directed by Engineer in Charge.
Supply only Integral water proofing compound (where ever required as directed by Engineer in Charge).
Material & Labour for two coats Distempering with 1st class quality acrylic distemper (ready mixed) on new work having VOC content less than 50 gms/litre, of required shade and colour complete as per manufacturer's specification with and including 3mm thick wall care putty on newly plastered surface wall complete all as specified and as directed
Complete removal of existing treatment by preparation of old decorated surfaces (White/Colour wash/distemper) of walls including cornices plasters etc including washing rubbing & scraping down and applying two coat of acrylic based distemper over a coat of alkali resistant (acrylic based) primer with and including 3 mm thick wall care putty complete all as specified and directed.
Material and Labour for preparation of new plastered surfaces of wall and applying priming coat of exterior primer applied @ 2.20 kg/10 sqm and finishing walls with two coat of Acrylic Smooth exterior paint of required shade @ 1.67 litre/10 sqm complete as per manufacturer's specification complete all as specified and as directed.
Material and Labour for old painted surfaces with complete removal existing paint and preparation of plastered surfaces of wall and applying priming coat of exterior primer applied @ 2.20 kg/10 sqm and finishing walls with two coat of Acrylic Smooth exterior paint of required shade @ 1.67 litre/10 sqm complete as per manufacturer's specification complete all as specified and as directed.
Material & Labour for preparing plastered surfaces and applying three coat of white wash on ceiling etc complete all as specified and directed.
Material & Labour for preparing old plastered surfaces and applying two coat of white wash on ceiling complete all as specified and directed.
Supply & Fix 18-19mm thick pre-laminated particle board (including dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cupboard shutter, shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thick on hanging side & French polishing to edging complete all as specified and directed.
Supply & Fix 25 mm thick pre-laminated particle board (including dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cupboard shutter, shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thick on hanging side & French polishing to edging complete all as specified and directed.
Material & Labour for 25mm thick second class hardwood, Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and as directed.
Supply & Fix 300 mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing and sliding bolt of extruded section and fixed to shutter with screw complete all as specified and directed.
Supply & Fix 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply & Fix 150 mm long aluminium door handle cast type fixed to shutter with screw complete all as specified and directed.
Supply & Fix Stainless Steel butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
Supply & Fix Safety chain in Entrance door fixed with complete fixtures as in repair complete all as specified and directed.
Supply & Fix Magic Eye in Entrance door including filling gaps in door with putty work etc in repairs complete all as specified and directed
Supply & Fix Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified.
Supply & Fix 75 mm long aluminium door handle cast type fixed to shutter with screw complete all as specified and directed.
Supply & Fix 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and as directed
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces exceeding 10 cm width or girth after preparation of surfaces complete all as specified and as directed
Material and Labour for applying one coats of synthetic enamel paint over old steel surfaces exceeding 10 cm width or girth after preparation of old surfaces complete all as specified and as directed
Material & Labour for two coat of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces over 10 cm width or girth complete all as specified and as directed.
Material and Labour for applying one coats of synthetic enamel paint over old wooden surfaces exceeding 10 cm width or girth after preparation of old surfaces complete all as specified and as directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Material & Labour For One light point controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 Sqmm size drawn through and including PVC conduit of suitable size concealed and all accessories, fire resistant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 Sqmm as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed.
Ditto as per item No 116 but One light point controlled by two 2-way switches, with cables 1.5 Sqmm size.
Ditto as per item No 116 but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size.
Ditto as per item No 116 but One ceiling fan point controlled by one switch.
Ditto as per item No 116 but for One exhaust fan point controlled by one switch.
Ditto as per item No 116 but One 3 pin socket outlet 5 amps on the independent board.
Ditto as per item No 116 but One 3 pin socket outlet 5 amps on the same board.
Ditto as per item No 116 but with cable 2.5 Sqmm for One 3/5 pin socket outlet 15 amps on the independent board.
Supply and fix Modular switch 1 way 6A/10,1 module.
Supply and fix Modular switch 2 way 6A,1 module.
Supply and fix Modular Bell push 6A 1 module complete.
Supply and fix Socket 6A - 2/3 pin combined 2 module complete.
Supply and fix Socket 6A/16A - 2/3 pin combined 2 module complete.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply and fix Ceiling rose, 3 phase/PVC/polycarbonate, isolated body, 65 x 50mm, 3 terminals complete all as specified and directed.
Supply and fix Modular stepped type electronic Fan step regulator, 120W - 2 modules complete all as specified and directed.
Supply and fix LED tube light fitting of 20 watt, Extruded aluminium housing enhances safety, high quality PC Diffuser, easy to install Efficacy 110/125 lumen/watt complete all as specified and directed.
Supply and fix LED tube light fitting of 10 watt, Extruded aluminium housing enhances safety, high quality PC Diffuser, easy to install Efficacy 110/125 lumen/watt complete all as specified and directed.
Supply and fix exhaust fan of size 300 m sweep, steel body AC single Phase, 230V with, blades, and frame and louvers complete all as specified and directed.
Supply and fix ceiling fan BLDC 1200 mm sweep, 230 volts, BEE 5 Star rated ISI Marked with canopy with all accessories such as nuts, bolts, clamps etc complete all as specified and directed.
Material & Labour for sub main wiring with two runs of single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked along with one run of 4 Sqmm multistranded insulated copper conductor cable as earth continuity conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required including taking down old one complete all as specified and directed. Note: Two Runs of PVC wires of 4 sqmm and One run of 4 sqmm earth wire and one run conduit will be measured as one unit.
Supply and fix sheet metal enclosure for MCCB DB Triple pole and neutral 4 ways, 415 volts with 200 Amps rated bus bar, double door, IP 54 all as specified and directed.
Supply and fix thermoplastic polycarbonate SPN DB 18 way/module, 220 Volts, in accordance with IEC 61439-3 hinged flap type shock proof, Rust free, Corrosion free, acid and chemical resistance, fire retardant, self extinguishing, PE+N terminals, IP 65 Protection including dismantling old one all as specified and directed
Supply and fix sheet metal enclosure for MCB DB Single pole and neutral 8 ways, 240 volts with 200 Amps rated bus bar, double door including dismantling old one complete all as specified and directed.
Supply, install, testing and commissioning of compatible thermoplastic polycarbonate of size 600 x 600 x 170 mm IP65 energy meter boards with hinged transparent cover, triangular lock and key, the meter board shall be with meter fixing rails suitable to fix 4Nos single phase prepaid / post paid meter and with DIN rails suitable to fix 1No 63A TPN MCB and 4Nos 32A SPN MCBs. Made of high quality Polycarbonate shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ). Meter enclosure shall withstand glow wire test at 960 Deg Centigrade in accordance with IEC 60 695-2-11 UL subject 94, shall be flame retardant and self-extinguishing in nature including dismantling old one complete all as specified and as directed.
Ditto as per item No 140 but of size 300 x 300 x 170 mm.
Supply & Fix in repair MCCB 63 Amps, 415V, 50 HZ, 4 pole of breaking capacity 16 KA, with adjustable thermal magnetic release setting complete all as directed
Supply and fixing MCB, 'C' curve, 10KA, 415V,TPN 40 to 100 Amps current carrying capacity in the DB complete with connection testing including dismantling old one complete.
Supply and fixing MCB, 'C' curve, 10KA, 240V, SPN 32 Amps current carrying capacity in the DB complete with connection testing including dismantling old one complete.
Supply and fixing MCB, 'C' curve, 10KA, 240V,SP 5 to 32 Amps current carrying capacity in the DB complete with connection testing including dismantling old one complete.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store.
Material & Labour for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete.
Material & Labour for Anti suicide fan rod with two parts upper and lower which are held together with the help of a spring mechanism. It will separate on applying excess load and load gets transferred on the spring which expands, made of GI Tubing 20 mm bore medium grade for length 0.30 metre to 1.2 metre as required at site suitable for Ceiling fan of size 1200mm/1400mm sweep including provision of holes at both ends for fixing nut and bolts complete all as specified.
Material & Labour for Earthing complete with GI Steel earth plate electrode 600X600X6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth wire of size 4 mm, dia by means of bolts, nuts, check soldered and riveted to earth plate. Earth wire will be protected by using 40mm dia bore GI pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metres etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009, connected to earthing test point all as specified or indicated including testing on completion including dismantling old one.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
M/S AARJAY ASSOCIATES
S K ENGINEERS
Kuriako Mathai and company
ELSOL ENGINEERS
KENZ CONSTRUCTIONS
LALA CONSTRUCTION
M/s S & S Enterprises/ Suresh Shivasankarapillai
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .