Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC EY 04 PODA WC CHANDIGARH A I A II B I | CHANDIGARH | CHANDIGARH | 160001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹36.1 L+₹1.6 L (4.57%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹37.2 L+₹2.8 L (8.00%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | L3 | Rejected-Finance Not being lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Validated |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 May 2021, 6:00 pmClosed
CWE WELLINGTON
Headquarters, Commander Works Engineers, Military Engineer Services Ministry of defence Wellington, Barraks-Post, The Nilgiris, PIN 643231
SPECIAL REPAIRS OF BLDG NO. BLOCK - IV AT ARMY AREA TRICHY UNDER AGE (I) COIMBATORE
2021_MES_436735_1
84407/E8
Open Tender
Civil Works
Item Rate
180 days
TRICHY
D Class a i Category
6 documents required · 6 mandatory
₹500
AGE (I) COIMBATORE
₹70,000
Yes
3 Jun 2021
16 Apr 2021
19 May 2021
16 Apr 2021
17 May 2021
3 May 2021
17 Apr 2021 - 24 Apr 2021
Amount
Taking down cement plaster of any description on brick or stone walls and ceiling including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L Rendering in cement mortar 1:6, 15mm thick finished even and smooth without using extra cement on fair faces of brick/concrete wall surfaces complete all as specified and as directed.
M&L Rendering in cement mortar 1:3, 5mm thick finished the surfaces even and smooth without using extra cement on fair faces ceiling surfaces complete all as specified and as directed.
M&L Rendering in cement mortar 1:6, 10mm thick as a backing coat and finishing coat in cement mortar 1:4, 5mm thick using WPC compound @ 3% by weight of cement finished even and fair on fair faces of brick/concrete wall surfaces complete all as specified and as directed. Note:- WPC Shall measured and paid in relevant item.
M&L Preparation of new plastered wall surface and applying two coat of cement base paint over a coat of alkali resistant primer on wall surfaces complete all as specified and directed .
M&L Complete removal of existing treatment of old treated surface and preparation, applying two coat of cement base paint over a coat of alkali resistant primer on wall surfaces complete all as specified and directed .
M&L Preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a priming coat using chalk whiting, complete all as specified and directed.
M&L Preparation of newly plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
M&L Complete removal of existing treatment of old treated surface, preparation and applying two coat of oil bound distemper over a priming coat using chalk whiting on wall surfaces complete all as specified and directed .
M&L Preparation of newly plastered surfaces, applying three coats of white wash as in ceiling complete all as specified and as directed.
M&L Complete removal of existing treatment, washing with water and bleaching powder solution and applying three coats of white wash on ceiling complete all as specified and directed.
M&L Complete removal of existing treatment, washing with water and bleaching powder solution and applying three coats of white wash on walls complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and as directed.
M&L Vitrified ceramic tiles, 10mm thick, light shades (square/rectangular) area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors etc., complete all as specified and as directed.
M&L 15mm thick, screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L Coloured / light coloured glazed ceramic tiles in vertical surface 300 x 200 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick cement plaster as backing coat in cement mortar 1:4 complete all as specified and as directed.
M&L Non skid coloured/light coloured ceramic tiles, 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick, screed bed or bedding layer for laying floor tiles in cement mortar 1:4. complete all as specified and as directed.
M&L Machine cut kota stone slab, 20-25mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and rounding of edges over and including 15 mm thick screed bedding layer in cement mortar 1:6 as in flooring complete all as specified and as directed.
M&L machine cut kota stone slab flooring, 20-25mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in riser of steps, skirting, dado and pillar complete all as specified and as directed.
M&L Granite slab (of any type), 20mm thick machine cut, laid, bedded and jointed with grey cement slurry 1:4 and pointed with white cement 1:2 with admixture of pigments to match with the shades of granite stone including cutting and polishing etc., over and including 20mm thick, screed bedding layer in cement mortar 1:6 as in platforms/cooking tops, complete all as specified and as directed
Rounding to edge of stone slabs one edge such as steps, cooking platform and other similar situation complete all as specified and as directed.
M&L Chequred cement concrete tiles with gray cement and pigment, 20cm x 20cm x 25mm thick, set and jointed and pointed in neat cement slurry over and including 15 mm thick, screed bedding layer in cement mortar 1:6, as in floors complete all as specified and as directed.
Taking up or down 15 mm bore, steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore, steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F GI steel water tubing, medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete all as specified and as directed for following bore of pipes:-
15mm dia bore complete all as specified and as directed.
20mm dia bore complete all as specified and as directed.
Refixing of old steel tubing and connection in new or old position (wall, ceiling, floors etc.,) steel tubing and connection, including cleaning for refixing complete all as specified and as directed.
15mm dia bore complete all as specified and as directed.
20mm dia bore complete all as specified and as directed.
Dismantling water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs and removing to store complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs, cylindrical vertical with closed top, hoisted and fixed in position all as specified in SSR Part I and as directed.
S&F 20 mm dia, ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 15 mm - 142 grams, 20 mm - 210 grams & 25 mm - 455 grams) complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs PVC low level flushing cistern, 10 ltrs capacity with complete accessories, PVC flush pipe, PVC over flow pipe etc., and connected to water closet as per manufacturers instruction including removal of existing cistern etc. complete all as specified and as directed.
S&F Stop valve, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and as directed.
S&F in repairs Stop valve, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and as directed.
S&F PVC connection, 15 mm size with PTMT nuts, 450 mm long complete all as specified and as directed.
S&F PVC connection, 15 mm size with PTMT nuts, 600 mm long complete all as specified and as directed.
S&F repairs Vitreous china Wash Hand Basin, white, flat back of size 600x480mm, (excluding taps, waste, chain and plug and porcelain stopper) but including brackets complete all as specified and as directed.
S&F waste coupling, PTMT, ( half or full threaded) (Minimum weight 32 mm - 45 gms) for 32 mm bore discharge pipe complete all as specified and as directed.
S&F Soap dish, vitreous China, white, approximate size 160x160x90mm complete all as specified and as directed.
S&F Pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes of 15mm bore complete all as specified and as directed.
S&F Bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore complete all as specified and as directed.
S&F in repairs Bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore complete all as specified and as directed.
S&F in repairs Health faucet including 1.2mtr long flexible tube with wall hook, complete all as specified and as directed.
S&F in repairs Brass chromium plated shower rose of size 75mm with swivel joints including shower arm 15mm bore, 195mm long with bend of 45 degree with flange for fixing h 15mm bore pipe complete all as specified and as directed.
S&F Towel rail, 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190 gms) complete all as specified and as directed.
S&F High density polyethylene pipes (HDPE),32 mm bore of pressure rating 6 Kgf/cm2 including making thread for fixing with waste coupling complete all as specified and as directed.
S&F in repairs stainless steel sink, over all size 910x420mm and bowl size with draining board and bowl size 410x330x160mm, made out of 1mm thick stainless steel sheet of good quality including proven of waste coupling and 40mm dia waste pipe fitted over a pair of CI brackets all as specified and as directed by the Engineer-in-Charge
Taking down eaves gutters and waste water pipes (any size or pattern), including all fittings, head, shoes, bends, swan necks etc, including removal to store complete all as specified and as directed.
S&F 75mm size, PVC (SWR) floor trap, plain with grating including joining with solvent cement complete all as specified and as directed.
S&F 110mm bore, PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including breaking the existing pipe complete all as specified.
S&F 75mm bore, PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including breaking the existing pipe complete all as specified.
S&F in repairs 110mm bore, PVC (SWR) bend any radius with access door suitable complete all as specified and as directed.
S&F in repairs 75mm bore, PVC (SWR) bend any radius with access door suitable complete all as specified and as directed.
S&F in repairs 110mm bore, PVC SWR branch piece double 'Y' equal or unequal with access door complete all as specified and as directed.
S&F in repairs 75mm bore, PVC SWR branch piece double 'Y' equal or unequal with access door complete all as specified and as directed.
S&F in repairs PVC (SWR) Vent cowl suitable for vent pipe 110mm bore complete all as specified and as directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exceeding 1.5 sqm each including separating guard bars/grills/wire mesh etc., all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exceeding 1.5 sqm but not exceeding 4sqm each including separating guard bars/grills/wire mesh etc., all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description not exceeding 1 sqm each including builders hardware as directed by the Engineer-in-Charge.
Taking down shutters of any description exceeding 1sqm but not exceeding 2 sqm each including builders hardware as directed by the Engineer-in-Charge.
Taking down and refixing in shutters In same opening of any description exceeding 1 sqm and not exceeding 2 sqm etc., complete all as specified and as directed.
M&L for Second class Hard wood, plain solid straight chowkats and frames rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fitted complete all as specified and as directed.
S&F 35mm thick, factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
Dismantling boarding any description fixed in any position with nails complete all as specified and as directed.
S&F 18/19mm thick, Preliminated particle boards interior grade, preliminated, one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work fixed in repairs complete all as specified and as directed.
Extra over item of Prelaminated particle board for external teak wood lipping, 6mm thick, fixed with nails suitable for 12mm thick complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed with stainless steel staples fixed to wood/steel frames all as specified and as directed by the Engineer-in-Charge.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metred cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall in repairs by drilling 100mm long MS screws using PVC fastener all as per specification and directed.
S&F Factory made solid PVC molded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick molded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing and all as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed with stainless steel staples fixed to wood/steel frames fixed in repairs all as specified and as directed by the Engineer-in-Charge.
S&F Sheet glass, 4mm thick, plain ordinary quality in squares not exceeding 0.50 sqm each pane and glazing with oil putty/wooden beads as directed complete all as specified and as directed.
S&F repair Sheet glass, 4mm thick, plain ordinary quality in squares not exceeding 0.50 sqm each pane and glazing with oil putty/wooden beads as directed complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame frames, including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S&F Securing glass of any description in existing Metal frames glazed with putty/beads including removing loose or decayed putty/beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work complete all as specified and as directed.
S&F 75mm size, Butt hinges, medium weight cold rolled mild steel etc., complete all as specified and as directed.
S&F 100mm size, Butt hinges, medium weight cold rolled mild steel etc., complete all as specified and as directed.
S&F 100mm long, aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 200mm long, aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 75 mm size, aluminium handles, cast type, anodised complete all as specified and as directed.
S&F 100 mm size, aluminium handles, cast type anodised complete all as specified and as directed.
S&F 150 mm size, aluminium handles, cast type anodised complete all as specified and as directed.
S&F 300mm long, aluminium alloy, anodised sliding door bolts with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified and as directed.
S&F 140 mm over all length of cover plates, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed.
S&F in repairs curtain rail, aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed.
M&L 40 mm dia, brass bright finished, cupboard knobs fixed with nuts, screws and washers complete all as specified and as directed.
M&L Preparation of new wooden surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L Preparation of old wooden surfaces of any description exceeding 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M&L Preparation of old steel surfaces any description exceeding 10cm width or girth for applying one coats of synthetic enamel paint all as specified and as directed.
M&L 75 mm thick, plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in plinth protection complete all as specified and as directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6.complete all as specified and as directed.
Demolition of brick work or stone/boulders masonry built in cement mortar or cement lime mortar complete all as specified and as directed.
Dismantling asbestos cement corrugated or semi corrugated sheets in roof coverings complete all as specified and directed
Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed
Dismantling of Battens for tiles, shingles etc, of any size including tilting fillets spaced exceeding 15 cm complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering /clading to wall , fixed with self tapping screws as specified complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section in any position framed work complete all as specified and as directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position framed work complete all as specified and as directed.
M&L Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc. Fe-410-W (Gde-E-250) Quality "A" complete all as specified and as directed.
M&L Preparing surface of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
S&F Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions including finishing all as specified and directed (Frame work for ceiling shall be measured and paid separately)
S&F GI frame work for seamless ceiling with size of grid 605 x 605 mm comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre complete all as specified and as directed.
Dismantling of existing roof treatment and stone slabs of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and as directed.
M&L for water proofing treatment with reinforced APP modified prefabricated five layer waterproofing membrane mineral finish, 3mm thick and weighing not less than 3.80 kgs/sqm reinforced with nonwoven polyester matt black finished over compatible primer at 0.40 Ltr/Sqm and torch applications of membrane with 100mm overlap after necessary preparation of surface complete as per manufactures instruction with bituminous aluminium paint on top 0.1 ltr/sqm complete all as specified and directed.
M&L for Screed bed or bedding layer 15mm thick in cement mortar 1:3 mixed with water proofing compound 3% by weight of Cement or as per manufacturer instruction as a base for APP membrane (WPC Compound paid separately) complete all as specified and as directed.
Supply only integral water proofing Compound complete all as specified and as directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L Providing precast cement concrete 1:2:4, Type B1, 20 mm graded aggregate set in cement mortar 1:4 in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers weathering, throating etc. and setting in mortar complete with joints to match complete all as specified and as directed.
M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
M&L mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
Taking down old/unserviceable/damaged point wiring carefully of any type (i.e. on wooden batten, surface conduit, casing & capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rowel plug, screw etc including making good disturbed surface to match the existing surface complete all as specified and directed.
Taking down main switches, distribution board, steel enclosure with MCB’s any way and rating including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed.
Taking down carefully service cable of any nos of wire and size with earth wire on wooden batten/surface conduit/casing & capping complete with its all accessories including making good disturbed surface to match the existing surface complete all as specified and directed.
M&L point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, non metallic PVC conduit and accessories on suitable for concealed conduit wiring, ISI marked suitable for surface conduit wiring with mild steel/pressed steel sunken box for module (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular inner and outer plates for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed by Engr-in-charge for the following:-
(a) One light/fan/Exhaust fan/bell point controlled by one switch 5 Amp one way complete all as specified and directed.
(b) One socket outlet 3 pin 5 amps in same board complete all as specified and directed.
(c) One socket outlet 3 pin 5 amps independent board complete all as specified and directed.
All as per item No 118 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge
S&F ceiling rose, polycarbonate isolated body with two to three terminals complete all as specified and directed.
S&F MCB DB sheet metal enclosures single pole and neutral, 230 Volt with 200 Amps rated bus bar and Double Door Type following type/capacity complete all as specified & directed
a) 12 Way complete all as specified and directed.
b) 8 way complete all as specified and directed.
S&F MCB SP, 6 Amps to 32 Amps capacity , 240 Volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps capacity, 240 volts complete all as specified and directed.
S&F Isolator, TPN, 100 Amps capacity, 415 Volts complete all as specified and directed.
S&F LED tube light fittings, 4 feet, with fixture 20 watts, 230v, 50HZ, including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
S&F LED tube light fittings, 2 feet, with fixture 10 watts, 230v, 50HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
M&L Earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, top edge of the plate not less then 1.5M below nominal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts and cheek nut and washer of galvanised iron including GI protection pipe and watering pipe all as shown in electrical plate No 3 of SSR Pt I including connection with main switch board all as specified including taking out old unserviceable earthing from existing location all as directed by Engr-in-Charge. Note:- Rate quoted shall deem to include for GI earth strip and GI protection pipe lead up to 7.5 mtr length.
Labour only for disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, revolving substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning including replacement of worn-out/unserviceable spares as required, replacement of PVC insulated unsheathed stranded twisted copper conductor cable of size 1.5 Sqmm up to 1.0 Mtr long assembling the repaired ceiling Fan, testing and hanging at position, connection with point wiring & Testing complete all as directed.
Labour only for disconnecting electrical wire from ceiling rose, taking down exhaust fan of any type/size and make, revolving substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the exhaust fan noise free for smooth functioning including replacement of worn-out/ unserviceable spares as required, replacement of PVC insulated unsheathed stranded twisted copper conductor cable of size 1.5 Sqmm up to 1.0 Mtr long assembling the repaired exhaust fan, testing and fixing at position, connection with point wiring & Testing complete all as directed.
Taking out geyser of any make and capacity for necessary repair/ replacement including refixing at its original position after repair with replacement of passivated bolt, nut, washer etc. complete all as specified and directed.
Taking out unserviceable inlet (cold water) connection pipe from Geyser and supply/fixing 45 cm long, PVC steel wire reinforced inlet pipe with nuts/thread adopter made of brass, complete all as specified and directed.
All as per item No. 131 her-in-before but for outlet (hot water) connection brass chromium plated complete all as specified and directed.
Supply only single phase electronic energy meter with LCD display as per IS 13779, ISI marked, 10-60 Amps capacity optical communication port complete all as specified and directed.
S&F Modular type switch, 6 amps, one module complete all as specified and directed
S&F Modular type, multi purpose socket, 6 amps, two module complete all as specified and directed
S&F Modular type switch, 16 amps, one module complete all as specified and directed
S&F Modular type multi purpose socket, 16 amps, two module complete all as specified and directed.
S&F Modular type fan regulator ,120 W, two module complete all as specified and directed.
S&F Call bell, 230 V, AC, single pole complete all as specified and directed
S&F Modular bell push, flush type, 5 Amp complete all as specified and directed.
M&L Wiring for circuit/sub main wiring using FR PVC insulated copper conductor cable of size 2x6 mm2 along with 1x6 mm2 single core cable for earth continuity to be drawn in non metallic PVC conduit in surface/ recessed as directed by Engr-in-charge Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length.
M&L Wiring for circuit/sub main wiring using FR PVC insulated copper conductor cable of size 2x4 mm2 along with 1x4 mm2 single core cable for earth continuity to be drawn in non metallic PVC conduit in surface / recessed as directed by Engr-in-charge. Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length)
S&F Sheet metal enclosure with 25 Amps socket including MCB SP, 25 Amps, 240 volts, 50 HZ suitable for AC connection complete all as specified and directed.
S&F LED fancy light fittings with fixture, 7 watts, 230v, 50 HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed. .
S&F LED bed light fittings with fixture, 7 watts, 230v, 50HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
S&F Ultra slim decorative aluminium casted, recess mounted square fixture in white finish with opal diffuser and separate/in built electronic driver suitable for low depth ceiling and Ceiling cutout 187x187 mm, height 19 mm for 15W complete all as specified and directed. ,
RAJASEKARAN
SEMBA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .