Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC LOA | |
| 2 | L2₹10.2 L+₹71,584 (7.55%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L2 | Rejected-Finance Highest |
Tender Value
₹9.8 L
EMD Value
₹19,680
Closing Date
26 Mar 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NAVEEN RATHEE
ED - Ambala
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations Under Rcs Udan Scheme in Ambala District (Pdg. Fan and Fittings).
2024_HRY_369891_1
202441A4CC1B 2003 45DD 834A D0FE435D3D2E663BAR
Open Tender
Civil Works
Works
490 days
Ambala Cantt
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations Under Rcs Udan Scheme in Ambala District (Pdg. Fan and Fittings).
2 documents required · 2 mandatory
₹1,000
₹19,680
Yes
4 Jul 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
Amount
[2.EL003] EL003. 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm)
[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
Supply and erection of IP20 linear recess type fitting made of extruded aluminium housing and PS diffuser. Fixture should have minimum efficacy at System level (Not Chip Level) )110lumens/watt and a minimum system lumen output of 2200 (downlight) lumens and maximum system wattage of 20W. Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance @45deg C ambient temperature, CCT up to 6500K, CRI )80, PF )0.95, THD(10% and an operating Voltage Range of 140 - 270 Internal Surge Protection 4KV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing Dimensions :- 1132mm x 67mm x 68.3mm etc. upto suitable pointrequired to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Philips/Wipro/Havells.
Supply and erection of 2x2 recess type fitting made of CRCA housing and PC diffuser. Fixture should have minimum efficacy at System level (Not Chip Level) )120lumens/watt and a minimum system lumen output of 3600 lumens and maximum system wattage of 31W. Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance @45deg C ambient temperature, CCT up to 6500K, CRI )80, PF )0.95, THD(10% and an operating Voltage Range of 140 - 270 Internal Surge Protection 3.5 KV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Philips/Wipro/Havells.
Supply and erection of suitable for general lighting recessed downlighter with 40mm height suitable for general lighting Luminaire should have die cast heat sink with polycarbonate diffuser. The luminaire should have CRI ) 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 1500 lumens and maximum system wattage of 13 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor )0.95, THD (10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Including 3 core 2.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Philips/Wipro/Havells.
Supply and erection of LED batten 34 Watt made of extrusion Alu. housing with high efficiency polycarbonate diffuser in IP20/IK02 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level )=120lumens/watt with Minimum system Lumens 2000lm, Life of fixture : 50000 burning Hrs. @ L70 Lumen maintenance, CCT of 6500K/4000K (SDCM(=5) , CRI )80, PF )0.98 and THD(10%,an operating Voltage Range of 140 - 270 VAC. Minimum Internal Surge Protection 3.0 KV. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab. Fixture to be BIS approved and proposed fixture product code to be mentioned in BIS Certificate submitted. upto suitable point required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make Philips/Wipro/Havells.
Supplying, errection, testing of 18` Wall fan Heavy Duty complete with suitable complete in all respect to satisfaction of Engineer-in-charge. Make: Crompton/Usha/Havells/Orient.
Supplying, errection, testing of 10` Fresh Air Fan 250mm complete with suitable complete in all respect to satisfaction of Engineer-in-charge Make: Crompton/Usha/Havells/Orient.
Supplying, errection, testing of 8` Fresh Air Fan 200mm complete with suitable complete in all respect to satisfaction of Engineer-in-charge Make: Crompton/Usha/Havells/Orient.
Supplying, errection, testing of 50 w Mono colour architecture Floodlight made of die cast Aluminium housing with optics of uv stabilised , polycarbonate cover and PC lens , operating temperature of -10 to 45 degree Celsius , surge protection of 4KV , average life of 50000 burning hrs , THD (10% and PF)0.95, CCT - Warm white / red / green/ blue Dimension of fixture should be minimum 250X150X78mm (LWH) Makes - Havells / Philips/ Wipro.
Supplying, errection, testing of Iron Jaal for Light safety size 24` x 24` including with necessary foundation for erection the light and safety Jall complete with all labour and material complete in all respect to satisfaction of Engineer-in-charge.
Supply and Erection of 10 Sq. mm 2 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Havells/Polycab/RR. ..
Som Nath Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .