Loading…
Loading…
Tender Value
₹7.2 L
EMD Value
₹18,070
Closing Date
18 Jun 2026, 11:00 amClosed
Executive Engineer
PH Division Malappuram
State Plan- State Plan 2025-26-Supply, erection, testing and commissioning of 3 HP Vacuum Pump, 100HP and 150HP Soft starters at New Clear Pump house, Malappuram
2026_KWA_854098_1
EE/PH/MPM/1/2026-27
Open Tender
Civil Works - Water Works
Item Rate
270 days
Malappuram
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,595
₹18,070
8 Jun 2026
8 Jun 2026
19 Jun 2026
8 Jun 2026
18 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Vacuum pump and Soft starter | |||||
| 1.001 | OD198307/2025-2026:Dismantling the existing oil starter in the pump house and stacking properly as per the direction of Engineer in site | - | no | - | - |
| 1.002 | OD198290/2025-2026:Supply, erection, testing and commissioning a complete integrated FCMA/soft starter panel capable of operating the motor (100 HP CF pump set, 3 phase AC 415V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules with a power control MCCB and line power contactor and the starting current shall be 2.5-3.5 times the normal full load current of motor with ammeter, voltmeter and phase indicator, space heaters, floor moulding type and having an inspiration level of 1100V (for 440 V supply) and 7.6KV for (3.3KV Supply) and 14.2 KV (for 6.6KV supply). The standard is to be I.E.C 60947-4-2 | - | no | - | - |
| 1.003 | OD198292/2025-2026:Supply, erection, testing and commissioning a complete integrated FCMA/soft starter panel capable of operating the motor (150 HP CF pump set, 3 phase AC 415V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules with a power control MCCB and line power contactor and the starting current shall be 2.5-3.5 times the normal full load current of motor with ammeter, voltmeter and phase indicator, space heaters, floor moulding type and having an inspiration level of 1100V (for 440 V supply) and 7.6KV for (3.3KV Supply) and 14.2 KV (for 6.6KV supply). The standard is to be I.E.C 60947-4-2 | - | no | - | - |
| 1.004 | OD198291/2025-2026:Supply, erection, testing and commissioning of 3 HP Vacuum pump set with the following specification.1-Pump and Motor-Supply, erection, testing and commissioning of KWA pre-qualified reputed make vacuum pump with motor and all accessories. Providing suitable concrete foundation as per the direction of departmental officers. 2- Starter-Supply, erection, testing and commissioning of 400/440 V suitable rating fully automatic DOL Starter with Thermal Over load relay as per IE rules.3-Panel board Supply, fixing, testing and commissioning of 3 Phase 440 volts, 50 HZ. Supply system having consisting of 1 No. suitable capacity 4 pole MCB as incomer and fitted with 3 Nos of LED indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter(Correct range) with selector switch and Controlling Circuit 2 AMPS C CLASS 1 POLE MCB s- 3 Nos etc of reputed make suitable for the above motor and conforming IS specifications.4- Cabling work - Supply, laying, testing and commissioning of suitable size Copper Cables and end termination lugs of required size and gauge suitable for above motor as per IE rules. 5-Capacitor-Supply, fixing, testing and commissioning of heavy duty APP 440 V,50 HZ Box capacitor above 0.99, The capacitor shall confirm to IS 2834/1986.6- EARTHING -Earthing the motor, panel, starter, capacitor and as per the direction of departmental officers. 7-Suction and delivery pipe connections - Connecting the Vacuum pump pipe connections to the existing CF pump sets (2nos) using U P V C ball valves, pipes and specials.8-Vaccum Pressure Gauge -Supply and fixing of Reputed make Glycerin filled vacuum pressure gauge with Steel Ball type valve and all accessories suitable for the (vacuum pump set). 9 -Foundation -Constructing Foundation for pump set with M:20 mix NSBS of suitable size and reinforcement torsteel in mesh in all directions and fixing foundation bolt to suitable base of the pumpsets as directed by the department officers. | - | no | - | - |
| 1.005 | OD199609/2025-2026:Supply and installation of single core copper cables suitable for the starter | - | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 1.68 MB
BOQ_1443554.xls
BOQ • 0.30 MB
DateCorregendum-extensionMalappuramPumpset.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .