Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 CrAccepted-AOC | ₹17.7 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹18.1 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹18.1 Cr | L2 | Rejected-Finance Being higher bidder |
| 3 | L3₹20.5 CrRejected-Finance | ₹20.5 Cr | L3 | Rejected-Finance Being higher bidder |
| 4 | Rejected-Technical B 31 32 2ND FLOOR INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 RAJASTHAN | JODHPUR | RAJASTHAN | 342003 | - | - | Rejected-Technical Not validated as sister concern of M/s Vishnu Infrastructures B 25 who is banned in CESC WLR for QE Sep 2020 Ser No 22 of Part II of WLR |
Tender Value
Refer Docs
EMD Value
₹12.3 L
Closing Date
19 Jan 2021, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone Jodhpur
PROVISION OF SEWAGE TREATMENT PLANTS (STP) AND SUMP CUM PUMP HOUSE INCLUDING NECESSARY PIPE LINE AT OUTRAM LINE, LANCER LINE AND HARNI AREA AT VADODARA UNDER GE (ARMY) BARODA (JOB NO SC/MW/1287)
2020_MES_391034_1
800501/BRD/2020-21/E8
Open Tender
Civil Works
900 days
Baroda
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
GE (A) Baroda
₹12.3 L
Yes
HQ CE Jodhpur Zone
18 Feb 2021
29 Oct 2020
21 Jan 2021
29 Oct 2020
19 Jan 2021
5 Jan 2021
18 Nov 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 27(R).
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 29(R)
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 31(R)
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 33(R)
Lump sum price worked out by the contractor for "ROAD & FOOTPATH" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 35(R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 37(R)
Lump sum price worked out by the contractor for "MISC (DRAIN, CULVERT AND WICKET GATE)" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 39(R)
Lump sum price worked out by the contractor for "SECURITY FENCING , COMPOUND WALL AND GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 40(R)
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 41(R)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION & DG SET" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 43(R)
Notes for Sch 'A' Part-XI (MISCELLANEOUS ITEMS) (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-II (SITE CLEARANCE, EXCAVATION & EARTH WORK schedule).
INTERNAL ELECTRIFICATION S&F of 4' 18W LED Tube With Batten with system lumen output of 1800 lumens. System efficiency should be > 115lm/ W. The Luminaire Should have Cool Daylight Colour temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accredited LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS.
S&F wall security light LED type 25 watt complete with and including bracket made out of GI pipe 40 mm bore light grade bend to shape required of length 1.5 mtr and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified.
Supply, fixing and testing energy efficient ceiling fan of 1200 mmsweep, 23 0 Volts, single phase, 50 Hz 3 blades, double ball bearing BLDC FAN , BE 5 Star rating connection up (Dust Resistance) complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rode, as per site requirement (approximate length 01 Mtr) complete all as specified and directed.
S&F engery efficient non-metalic exhaust fan having blade sweep 300 mm, air delivery not less than 720 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S&F ISI marked MCB having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, complete all as specified and directed of following :-
5 A to 32 Amps SP MCB, C- curve
32 Amp, SPN MCB, C- curve
M&L for submain wiring using ISI marked 1.1 kV grade single core FRLS cable, 2 runs of 4.00 sqmm main cable and one runs of 4.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB UPVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Two runs of main cable + one runs of earth conductor and one run of UPVC conduit shall be measured as one RM.
ROAD/PATH/CULVERT & HARDSTANDING M&L for 150 mm thick (compacted thickness) ready mix wet mix macadam (WMM) using materials of 30 CBR, in two layers each of 75 mm thick (each layer to be rolled and consolidated seperately) confirming to the grading given in table 400-13 and physical requirements given in table 400-12 spread with mechanical means as specified, hollows made upto for true surface, spread, surface binding with and including screening and moorum, watered, consolidated and rolled with vibratory roller 8 to 12 tonne as per clause 406.3.5 of MORT&H to required gradient and camber complete all as specified and as directed.
SEWAGE DISPOSAL M&L for DWCPE pipe 150 mm nominal dia of class SN8 complete laid in trenches including tested complete all as specified in IS 16098:2013 complete all as specified and as directed.
Ditto as per item No 19.00 above but of nominal dia 200 mm.
Ditto as per item No 19.00 above but of nominal dia 250 mm.
Ditto as per item No 19.00 above but of nominal dia 300 mm.
NOTE FOR ITEM No 19.00 to 22.00:- (i) Inner & outer dia shall be as per IS code.(ii) Stiffness class of the pipe shall be of SN8.
M&L providing factory made pre-cast FRC (Fibre reinforced concrete) manhole cover and frame 900mmx900mmx75mm HD-20 grade including provn of mild steel flat framing for edge protection and finishing etc complete all as per IS 12592 of 2002 setting in cement mortar 1:3 and haunching with cement concrete 1:2:4 type B-1 complete all as specified and directed
Ditto as per item No 23.00 above but size 750mmx750mmx75mm.
M&L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregae in concrete bedding to drain pipes includng packing under and haunching against the sides of pipes after they are laid and tested for 250mm bore pipe complete all as specified and directed
M&L for mild steel TMT bars 8mm dia Corrosion Resistant Steel (CRS) Fe 500 Grade conforming to IS-1786 (Latest issue) in reinforcement cut to length bent to shape required including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over Corrosion Resistant Steel (CRS) Fe 500 Grade conforming to IS-1786 (Latest issue) in reinforcement cut to length bent to shape required including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto as per item No 27.00 above but size 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders.
EXTERNAL WATER SUPPLY Supply and lay DI (Ductile iron) pipes of size 100 mm dia with spigot and socket ends with tyton joint S/S class K-9, in any length, laid in trenches including testing on completion complete all as specified and directed. Note: - 1. Ductile Iron Specials/Fittings, excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials.
Supply and lay DI (Ductile iron) FITTINGS such as bends (any radius and angle) tapers any type (straight bend, increasing, decreasing or double socket etc. tee pieces etc. 80 to 150 mm bore with tyton joint S/S class K-9. Note:- 1. Excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials.
S&F sluice valve,100 mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.60, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
S&F sluice valve, 80mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.00, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
S&F PVC foot valve Ball type conforming to IS-4038 of size 100 mm including jointing, such as rubber/fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
M&L for Construction of fly-ash brick masonary valve chamber of size 750 mm X 750 mm X 750 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate,150 mm thick & 150 mm wide offsets all around, fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including excavation earth work in any type of soil, 3.0 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Supply,Installation,Testing & Commissioning LT Out door type Panel board (Factory made of approved CPRI) size as recommended by IS&CPRI norms made out of CRCA sheet 3.00 mm thick dust proof ,powder coated from both side,individual door,factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 150 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a seperate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 40x40x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following:-
(i) Copper bus bar 150 amps for phase&neutral-04 Nos (ii) MCCB 4P 63amps,16KA-01 Nos (incomg) (iii) MCB TPN 32amps,10KA-02 Nos (iv) MCB SPN 20 amps -02 Nos (v) Multifunctional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 set (vi)I ndicator lamp (LED R-Y-B) 01 Set (vii) Capacitor bank 1X5KVAR-01 No (FOR SUM CUM PUMP OUT SIDE)
Supply, Installation, commissioning and testing of LT outdoor panel board (factory made of approved CPRI) size as recommended by IS & CPRI norms & outdoor type made out of CRCA sheet 3.00 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 150 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 40x40x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :-
(i) Copper bus bar 150 amps for phase & neutral-04 Nos (ii) MCCB 4P 100 Amps, 25 KA- 01 Nos (In coming) (iii) MCCB TPN 63 Amps, 25 KA - 01 Nos (O/G for IPS) (iv) MCB SPN 20 Amps -02 Nos (O/G for Duty room & SL ) (v) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (vi) Indicator lamp (LED R-Y-B)- 01 Set (vii) Capacitor bank 1 x 5 KVAR-01 No (FOR STP OUT SIDE)
S&F factory made junction box of size 240 x 130 x 110 mm with 4 Nos of AL bus bar of suitable capacity for street light fixed on pole, made out of CRCA sheet 2mm thick having front hinged shutter with lockable arrangements, outdoor type, weather proof duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 10 sqmm 2 core and one number MCB SPN,(0-40) A 10 KA,240 volts and earthing point complete all as specified and directed by Engineer-in-Charge.
S&F copper conductor multistranded/solid of size 1.5 Sqmm for phase and neutral and 1.50 Sqmm for earth wire on poles or passing through PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete all as specified and directed. Note:- One run of phase conductor + one run of neutral + one run of earth wire + one run of PVC conduit shall be measured as one RM.
S&F testing and commissioning of LED street light fittings arthetically designed roadway luminare with excellent thermal management with following specification as per cat no. LSTP-72 CDL 72 WATT OF MAKE CG or technocommercial equvivalent of make as approved by GE, including S&F GI pipe bracket using 25 mm bore light grade, bent to shape made out of 1.50 m long GI pipe complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip earth 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of protection pipe galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTE FOR ITEM NO 40.00:- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth GI earth strip 32 x 6mm. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of protection pipe galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTE FOR ITEM NO 41.00:- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M&L for well burnt clay bricks sub class 'B' designation 75 Old size bricks as in protection of cable laid dry, flat abutting each other width wise all as directed
DG SET Supply, installation, testing & commissioning of silent Diesel Engine driven generating set 40 KVA, 32 KW, 415 volts, 3 phase 4 wire, Diesel engine of 56 HP 03 Cylinder, 1500 RPM liquid cooled as per IS : 10001/10002 and IS : 13364 and alternator of H Class insulation 1500 RPM, 0.8 power factor self excited and self regulated excitation, electronic AVR mounted with +/- 1% voltage regulation, 10% over load for 1 hrs once in 12 hrs as per IS-13364 complete with AVM foundation mounted, AMF control panel with micro processor based controller with graphical LCD display to monitor lube oil pressure, engine temperature, RPM, lube oil temperature, run hrs number of start, fuel level, auto/manual stop, battery charge condition, AC phase voltage, current KVA, KW, KVAR, KWH, power factor with diagnostic features battery charging failure, over speed, under speed, over current, under voltage, over voltage, phase sequence, phase missing, low lube oil pressure, high engine temperature, low high voltage battery, low fuel alarm, over crank protection routine maint indicator gen set facility fail to start stop, with aesthetically designed weather and sound resistence canopy with sound level with 75 db, installation confirms to UL 94-HF1 Class (For STP)
Supply, installation, testing and commissioning of silent Diesel Engine driven generating set 10 KVA, 08 KW, 415 volts, 3 phase 4 wire, Diesel engine of 16 HP 03 Cylinder, 1500 RPM air cooled as per IS : 10001/10002 and IS : 13364 and alternator of H Class insulation 1500 RPM, 0.8 power factor self excited and self regulated excitation, electronic AVR mounted with +/- 1% voltage regulation, 10% over load for 1 hrs once in 12 hrs as per IS-13364 complete with AVM foundation mounted, AMF control panel with micro processor based controller with graphical LCD display to monitor lube oil pressure, engine temperature, RPM, lube oil temperature, run hrs number of start, fuel level, auto/manual stop, battery charge condition, AC phase voltage, current KVA, KW, KVAR, KWH, power factor with diagnostic features battery charging failure, over speed, under speed, over current, under voltage, over voltage, phase sequence, phase missing, low lube oil pressure, high engine temperature, low high voltage battery, low fuel alarm, over crank protection routine maint indicator gen set facility fail to start stop, with aesthetically designed weather and sound resistence canopy with sound level with 75 db, installation confirms to UL 94-HF1 Class (For Sump cum Pump House)
Supply, installation, testing and commissioning of silent Diesel Engine driven generating set 30 KVA, 24 KW, 415 volts, 3 phase 4 wire, Diesel engine of 42 HP 03 Cylinder, 1500 RPM liquid cooled as per IS : 10001/10002 and IS : 13364 and alternator of H Class insulation 1500 RPM, 0.8 power factor self excited and self regulated excitation, electronic AVR mounted with +/- 1% voltage regulation, 10% over load for 1 hrs once in 12 hrs as per IS-13364 complete with AVM foundation mounted, AMF control panel with micro processor based controller with graphical LCD display to monitor lube oil pressure, engine temperature, RPM, lube oil temperature, run hrs number of start, fuel level, auto/manual stop, battery charge condition, AC phase voltage, current KVA, KW, KVAR, KWH, power factor with diagnostic features battery charging failure, over speed, under speed, over current, under voltage, over voltage, phase sequence, phase missing, low lube oil pressure, high engine temperature, low high voltage battery, low fuel alarm, over crank protection routine maint indicator gen set facility fail to start stop, with aesthetically designed weather and sound resistence canopy with sound level with 75 db, installation confirms to UL 94-HF1 Class (For STP)
S&F on load change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified & directed.
S&F on load change over switch 415V in sheet metal enclosures 4 pole of capacity 40 Amps complete all as specified & directed.
S&F on load change over switch 415V in sheet metal enclosures 4 pole of capacity 32 Amps complete all as specified & directed.
STP EM ITEMS Supply, installation and testing of bar screen made in stainless steel 304 material consisting of 02 Nos made of closely spaced strip of 3x30mm spacing of 30mm center to center and fixed at an angle of 60 degree to horizontal unit size not less than 90x1100x1000 mm. OEM bar screen unit is made in stainless steel 304 degree material and bottled to side walls using anchor bolts of SS304 material in the middle of bar screen chamber depth for STP of capacity 1000 m3/day
Ditto as per item No 49.00 above but for STP of capacity 600 m3/day
Ditto as per item No 49.00 above but for STP of capacity 400 m3/day
Supply, installation and testing of Submersible Non clog pump Sets (Transferring sewage from equalization tank to MBBR) having a minimum flow rate capacity not less than 21000 LPH at not less than10 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet as 100mm dia MS Pipe, foundation in PCC 1:3:6 type C-1 complete all as specified & directed.
Ditto as per item No 52.00 above but flow rate capacity not less than 12600 LPH.
Ditto as per item No 52.00 above but flow rate capacity not less than 8400 LPH.
Supply, installation and testing of Non clog self Priming pump Sets for transferring sludge from MBBR tank to sludge holding tank having minimum flow rate capacity not less than 7000 LPH at not less than 15 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having inlet/outlet as per pump manufacturer & including of piping & valve Foundation in PCC 1:3:6 type C-1 complete all as specified & directed.
Supply, installation and testing of Centrifugal monobloc type pump Sets for transferring water for tertiary treatment (Clarified water Pumps from chlorine contact tank to Pressure sand filter) having a minimum flow rate capacity not less than 21000 LPH at not less than15 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 50mm dia foundation in PCC 1:3:6 type C-1 complete all as specified and directed.
Ditto as per item No 56.00 above but flow rate capacity not less than 12600 LPH at 15 m head.
Ditto as per item No 56.00 above but flow rate capacity not less than 8400 LPH at 15 m head.
Supply, installation and testing of Centrifugal monobloc type pump Sets for transferring Clear water for Re use having a minimum flow rate capacity not less than 21000 LPH at not less than 15 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having inlet/outlet as 80mmx65mm foundation in PCC 1:3:6 type C-1 all as specified and directed.
Ditto as per item No 59.00 above but flow rate capacity not less than 12600 LPH.
Ditto as per item No 59.00 above but flow rate capacity not less than 8400 LPH.
Supply, installation and testing of Air diffuser line for Equalization Tank and MBBR Tank consisting of followings -
(a) (3 Nos ) of rotary twin lobe design blowers of approved make duly installed on suitable channel iron frame and grouted to floor in PCC 1:3:6 type C-1 in the panel room each blower has an air discharge capacity not less than 400 m3 per hour at a pressure not less than 0.5kg/cm2 and equipped with all standard accessories connected with MS piping from blowers upto equalization tank and MBBR tank with suitable control valve pressure gauge & Piping etc. (b) Coarse bubble diffuser of approved make and EPDM material 04 Nos diffuser with distribution Piping Grid required for MBBR tanks and 04 Nos diffuser with flow rate not less than 7 to 10 cum per hour and size not less than 150mm dia as per drawing of OEM. (c) Fine bubble diffusers 14 Nos in EPDM/SILICON material Circular with flow rate not less than 7 to 10 cum per hour and size not less than 63mm dia duly fitted on PVC pipeline grid in the bottom portion of MBBR tank as per drawing and as directed by OEM. (d) Lamella FRP plate settler or Tube Deck Media/ Vol quantity as per OEM Design. (e) MBBR Media type Fluidized bio media black colour material Virgin PP UV Stabilized of size not less than 22mm dia and 15mm length or as per OEM Design. (f) Suitable Lamella box / structural steel support with Anti non corrosive paint to fix FRP lamella plates/tube settler for settling sludge from sewage as per site/ OEM requirement (g) Media Catcher screen MSEP material in position in the MBBR tanks. As per OEM design-3 Nos)
Supply, installation and testing of Air diffuser line for Equalization Tank and MBBR Tank consisting of followings-
(a) (3 Nos ) of rotary twin lobe design blowers of approved make duly installed on suitable channel iron frame and grouted to floor in PCC 1:3:6 type C-1in the panel room each blower has an air discharge capacity not less than 250 m3 per hour at a pressure not less than 0.5kg/cm2 and equipped with all standard accessories connected with MS piping from blowers upto equalization tank and MBBR tank with suitable control valve pressure gauge & Piping etc. (b) Coarse bubble diffuser of approved make and EPDM material 04 Nos diffuser with distribution Piping Grid required for MBBR tanks and 04 Nos diffuser with flow rate not less than 7 to 10 cum per hour and size 150mm dia as per drawing of OEM. (c) Fine bubble diffusers 14 Nos in EPDM/SILICON material Circular with flow rate not less than 7 to 10 cum per hour and size 63mm dia duly fitted on PVC pipeline grid in the bottom portion of MBBR tank as per drawing and as directed by OEM. (d ) Lamella FRP plate settler or Tube Deck Media/ Vol quantity as per OEM Design (e) MBBR Media type Fluidized bio media black colour material Virgin PP UV Stabilized of size not less than 22mm dia and 15mm length or as per OEM Design (f) Suitable Lamella box / structural steel support with Anti non corrosive paint to fix FRP lamella plates/ tube settler for settling sludge from sewage as per site/ OEM requirement (g) Media Catcher screen MSEP material in position in the MBBR tanks. As per OEM design - 3 Nos)
Supply, installation and testing of Air diffuser line for Equalization Tank and MBBR Tank consisting of followings:-
(a) (2 Nos ) of rotary twin lobe design blowers of approved make duly installed on suitable channel iron frame and grouted to floor in PCC 1:3:6 type C-1 in the panel room each blower has an air discharge capacity not less than 300 m3 per hour at a pressure not less than 0.5kg/cm2 and equipped with all standard accessories connected with MS piping from blowers upto equalization tank and MBBR tank with suitable control valve pressure gauge & Piping etc. (b) Coarse bubble diffuser of approved make and EPDM material 04 Nos diffuser with distribution Piping Grid required for MBBR tanks and 04 Nos diffuser with flow rate not less than 7 to 10 cum per hour and size 150mm dia as per drawing of OEM. (c) Fine bubble diffusers 14 Nos in EPDM/SILICON material Circular with flow rate not less than 7 to 10 cum per hour and size 63mm dia duly fitted on PVC pipeline grid in the bottom portion of MBBR tank as per drawing and as directed by OEM. (d) Lamella FRP plate settler or Tube Deck Media/ Vol quantity as per OEM Design (e) MBBR Media type Fluidized bio media black colour material Virgin PP UV Stabilized of size not less than 22mm dia and 15mm length or as per OEM Design. (f) Suitable Lamella box / structural steel support with Anti non corrosive paint to fix FRP lamella plates/tube settler for settling sludge from sewage as per site/ OEM requirement (g) Media Catcher screen MSEP material in position in the MBBR tanks. As per OEM design - 3 Nos)
S&F Probe type electronic water level controllers including copper wiring complete all as specified and directed.
S&F Automatic Chlorine solution Doser for treatment 2 Nos of these dosers are required for chlorine solution and 2 Nos for alum solution dosing equipped with diaphragm type electro magnetic pump not less than 0.5 HP capacity working on 415 V 3 phase 50 c/s AC supply flow rate not less than 0 to 06 liters/hour at an injection pressure of 3.5 kg/sq cm including a solution tank not less than 300 ltrs capacity in HDPE /PP material, Pump of 230 V single phase 50 c/s ACs supply and with SS 304 agitator assembly necessary connecting piping etc all complete for 1000 KLD plant.
Ditto all as per item No 66.00 above but for 600 KLD plant.
Ditto all as per item No 66.00 above but for 400 KLD plant.
S&F Suction and Delivery header in MS medium grade pipe not less than 4" (5 meter) & 6" (10 meter) NB size for submersible pump fitted in Wet well & Equalization tank to pump to Bar screen /MBBR tank system duly welded and painted with anti corrosive bituminous coating in side and apply two coats of aluminium paint over a coat of red oxide primer on external surfaces complete all as specified and directed.
S &F Suction and delivery header in MS medium grade pipe not less than 4" (5 meter) & 6" (10 meter) NB size for non clog type centrifugal coupled pump fitted for sludge transfer near settling tank duly welded and painted with anti corrosive bituminous coating in side and and apply two coats of aluminium paint over a coat of red oxide primer on external surfaces complete all as specified and directed.
S&F Delivery header in MS medium grade pipe not less than 2" (5 meter), 4" (5 meter) & 6" (10 meter) NB size for centrifugal pump fitted for treated water to tertiary treatment near chlorine contact tank duly welded and painted with anti corrosive bituminous coating in side and and apply two coats of aluminium paint over a coat of red oxide primer on external surfaces complete all as specified and directed.
S&F Suction and delivery header in MS medium grade pipe not less than 3" (10 meter) NB size for non clog type centrifugal coupled pump fitted for sludge transfer near settling tank duly welded and painted with anti corrosive bituminous coating in side and and apply two coats of aluminium paint over a coat of red oxide primer on external surfaces complete all as specified and directed.
S&F Delivery header in MS medium grade pipe not less than 2" (10 mtr) and 3 " (10 mtr) NB size for centrifugal pump fitted for treated water to tertiary treatment near chlorine contact tank duly welded and painted with anti corrosive bituminous coating in side and and apply two coats of aluminium paint over a coat of red oxide primer on external surfaces complete all as specified and directed.
S&F PP ball Valve both ends flanged with bolts nuts rubber gaskets etc for following dia:-
110 mm dia
160 mm dia
80 mm dia
63 mm dia
S&F PP non return ball Valve both ends flanged with bolts nuts rubber gaskets etc for following dia:-
110mm dia
160 mm dia
80 mm dia
63mm dia
S&F PP foot valve both ends flanged with bolts nuts rubber gaskets etc for following dia:-
110 mm dia
80 mm dia
63 mm dia
S&F Sludge Handling by screw type pump Sets for transferring sludge to filter press having a minimum flow rate capacity not less than 1000 LPH at not less than 45 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having inlet/outlet as 80mmx65mm foundation in PCC 1:3:6 type C-1 complete all as specified and directed.
S&F filter press for sludge handling size 24"x24" with 24 plates, hydraulic operation with 2.0 HP/1.5 KW to remove water from sludge & form cakes for 400 KLD plant.
S&F filter press for sludge handling size 36"x36" with 36 plates, hydraulic operation with 3.0 HP/2.2 KW to remove water from sludge & form cakes for 1000 KLD & 600 KLD plant.
S&F Multigrade Quartz Sand filter for filtering treated sewage water at a flow rate not less than 44000 LPH 2000 mm dia x 2000 mm height HOS total height not less than 4000 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 7000 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 1000 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than1000 Kgs b) Layer II - quartz sand 1/2" size not less than 400 Kgs c) Layer III - quartz Sand 1/4" size not less than400Kgs d) Layer IV - quartz Sand 1/8" size not less than 400 Kgs e) Layer V- quartz Sand1/16" size not less than 4800 Kgs
S&F Activated carbon filter for filtering treated sewage water at a flow rate not less than 44000 LPH 2000 mm dia x 2000 mm height HOS total height not less than 4000 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 7000 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 1000 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than1000 Kgs b) Layer II - quartz sand 1/2" size not less than 400 Kgs c) Layer III - quartz Sand 1/4" size not less than400Kgs d) Layer IV - quartz Sand 1/8" size not less than 400 Kgs e) Layer V- quartz Sand1/16" size not less than 4800 Kgs
S&F Multigrade Quartz Sand filter for filtering treated sewage water at a flow rate not less than 26000 LPH 1600 mm dia x 2000 mm height HOS total height not less than 3600 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 4780 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 600 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than 600 Kgs b) Layer II - quartz sand 1/2" size not less than 260 Kgs c) Layer III - quartz Sand 1/4" size not less than 260Kgs d) Layer IV - quartz Sand 1/8" size not less than 260 Kgs e) Layer V- quartz Sand1/16" size not less than 3400 Kgs
S&F Activated carbon filter for filtering treated sewage water at a flow rate not less than 26000 LPH 1600 mm dia x 2000 mm height HOS total height not less than 3600 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 4780 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 600 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than600 Kgs b) Layer II - quartz sand 1/2" size not less than 260 Kgs c) Layer III - quartz Sand 1/4" size not less than 260Kgs d) Layer IV - quartz Sand 1/8" size not less than 260 Kgs e) Layer V- quartz Sand1/16" size not less than 3400 Kgs
S&F Multigrade Quartz Sand filter for filtering treated sewage water at a flow rate not less than 17000 LPH 1300 mm dia x 2000 mm height HOS total height not less than 3300 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 3145 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 400 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than 420 Kgs b) Layer II - quartz sand 1/2" size not less than 165 Kgs c) Layer III - quartz Sand 1/4" size not less than 165Kgs d) Layer IV - quartz Sand 1/8" size not less than 165 Kgs e) Layer V- quartz Sand1/16" size not less than 2230 Kgs
S&F Activated carbon filter for filtering treated sewage water at a flow rate not less than 17000 LPH 1300 mm dia x 2000 mm height HOS total height not less than 3300 mm fitted with all frontal piping in 2" medium grade mild steel material fitted with 5 Nos. of MSEP lined coat iron diaphragm valve, a handhold pressure gauge inbuilt back-washing and cleansing arrangement , Air vent in 1" NB mild steel medium grade piping with a 1" size rubber lined coat iron diaphragm valve the filter is constructed out of mild steel sheets duly coated with anti-corrosive bituminous paint inside and externally painted with 2 coats of red oxide and two coat of aluminum paint externally and equipped with special white QUARTZ sand not less than 3145 kg quantity in five grades as filter media etc all complete. Filter media comprising white quartz gravel and white quartz sand in five different grade in prescribed layer into sludge beds as directed and as specified in quantities as follows. (for 400 KLD STP)
a) Layer I - quartz Gravel1 to 1.5"size not less than 420 Kgs b) Layer II - quartz sand 1/2" size not less than 165 Kgs c) Layer III - quartz Sand 1/4" size not less than 165Kgs d) Layer IV - quartz Sand 1/8" size not less than 165 Kgs e) Layer V- quartz Sand1/16" size not less than 2230 Kgs
Supply, installation, testing & commissioning for LT panel board CPRI approved floor mounted cubical type indoor type dust proof aesthetically designed and fabricated from 2 mm thick CRCA sheet with front and rear opening conforming to IS:8623 and including bus bar chamber for continuous length of panel GI earth strip bus bar din rail channels cable alleys panel exhaust fan 02 Nos. with its control switches. Front and sides of angle iron frame above GL should be covered with CRCA sheet fixed with nuts, bolts, danger notice board mounted on front side of panel MS angle iron frame 40x40x6 mm 0.45 m above ground level and 0.3 m grouted in ground/floor including necessary excavation in pack foundation PCC 1:4:8 type D2 complete with locking arrangement including lock 65 mm brass key duly powder coated with rust proof paints connecting incoming and outgoing cable connections with suitable lugs, nuts, bolts, washers and cable glands, prewired complete with suitable size PVC insulated fire retardant copper conductor, etc and including following :-
(a) MCCB of capacity -400 Amps,4 pole,415 Volt 50 Hz 25 KA- 01 No (b) Bus bar-04 Nos(3 for Phase and 1 for Neutral) made of copper mounted on FRP Moulded epoxy insulator with inter connection using copper cable of cap 600 A (c) MCCB TP of Capacity - 100 Amps, 415 Volt, 50 Hz 16 KA - 3 Nos. (d) MCCB TP of Capacity - 63 Amps, 415 Volt, 50 Hz 16 KA - 3 Nos. (e) MCCB TP of Capacity - 32 Amps, C series, 415 Volt, 50 Hz 10 KA - 6 Nos (f) MCB SP of Capacity - 20 Amps, C series, 415 Volt, 50 Hz 10 KA - 5 Nos (g) DOL Starter for 5 HP Motor - 03 Nos (h) DOL Starter for 3 HP Motor - 03 Nos (j) DOL Starter for 2 HP Motor - 01 Nos (k) FASD Starter for 10 HP Motor - 03 Nos (l) MCB TP of capacity 32 Amps, 230 Volts 50 Hz, 10 KA = 01 No
Supply,Installation,Testing & Commissioning Non clog submersible cutter design sewage pump with chrome steel Impeller and cutter ,non clog to pass 40mm size particles of discharge capacity not less than 20000 LPH at not less than 18 mtr head, (for Sum cum Pump House 02 Nos working and 01 No stand by)
Supply,Installation,Testing & Commissioning Non clog submersible cutter design sewage pump with chrome steel Impeller and cutter ,non clog to pass 40mm size particles of discharge capacity not less than 20000 LPH at not less than 15 mtr head, (for Sum cum Pump House 02 Nos working and 01 No stand by)
S&F air break DOL starter push button type suitable for 5.5 KW/7.5HP 3 phase 415 V AC electric motor complete all as specified and directed by Engineer in Charge.
S&F sluice valve, 100mm size, non-rising type with CI wheel, drilled flanged ends, PN-1.00, ISI marked, heavy duty with stainless steel spindle and gun metal working parts including flanged jointing on both ends, jointing material such as rubber / fibre board gasket, suitable size bolts, nuts and twin washers complete all as specified and directed.
M&L for Construction of fly-ash brick masonary valve chamber of size 1000 mm X 1000 mm X 1000 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate,150 mm thick & 150 mm wide offsets all around, fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including excavation earth work in any type of soil, 3.0 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for Boring of holes under road ,pavement, hard standing of depth maximum 1.5 mtr in any strata by trenchless technology using ultra sound technic and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified & directed.
Supply and lay DI (Ductile iron) pipes of size 150 mm dia with spigot and socket ends with tyton joint S/S class K-9, in any length, laid in trenches including testing on completion complete all as specified and directed. Note: - 1. Ductile Iron Specials/Fittings, excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials.
M&L for provision of fire stand of suitable size made out of MS angle iron/ channel, including PCC and brickwork for making suitable size of platform as directed and painted with two coats of synthetic red enamelled paint over a coat of red oxide primer and writing of FIRE POINT with white enamelled paint as per standard size of words, including :- (a) Galvanized MS fire bucket 14 Ltrs capacity-01 Nos (b) Fire Extinguisher dry powder type (ABC type)-9/10 Kg -04 Each (c) Fire beater -03 Nos (d) Fire hook-03 Nos
S&F Shock treatment chart of size 0.50m x 0.25m with Photos duly framed in glass with hanging arrangement of suitable size complete all as specified and as directed.
M&L for Glow Sign board of size 3.0m x 1.0m x 0.4m with acrylic sheet with writing of Installation Name, Capacity and area including 2 Nos LED Tube light fitting including fixing arrangement on wall, letter size as per direction of Engineer-in-charge complete
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip earth 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTE FOR ITEM NO 97.00:- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M GI earth strip of size 25 x 4 mm. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Outsourcing services for running of sewage Pump house installation at STP (Harni) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at STP (Lancer Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connecting to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at STP (Outram Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at Sump cum Pump House (Lancer Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. (For IPS) Note : The contractor shall employ One FGM in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at Sump Cum Pump House (Outram Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. (For IPS) Note : The contractor shall employ One FGM in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at STP (Harni) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at STP (Lancer Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connecting to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at STP (Outram Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. Note : The contractor shall employ One FGM and Two helpers in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at Sump cum Pump House (Lancer Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. (For IPS) Note : The contractor shall employ One FGM in each shift of 08 hrs
Outsourcing services for running of sewage Pump house installation at Sump Cum Pump House (Outram Line) GE (Army) Baroda comprising of all plants/machinery/equipments/devices etc of any type, any make, any capacity inside installation premises including Sunday and holiday with mobile connectivity to receive instructions at installation during duty. (For IPS) Note : The contractor shall employ One FGM in each shift of 08 hrs
PROVISIONAL LUMP SUM (PLS) Provide Provisional lump sum for M&L Steel gate 5.50 metre wide and 1.50 m high complete all as specified & directed.
NOTE FOR ITEM NO 108.00:- 1) Provisional lump sum shall be expended wholly or in parts as directed by GE. The works under Provisional Lump Sum shall be measured and paid for at applicable rates in MES SSR 2010 Part-II subject to percentage ( + or - denomination) computed under last column of this schedule above/below the provisional lump sum price worked out by the MES. (2) For details refer relavent TD drawings.
FRIZO INDIA PVT LTD
Komal Buildcon Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid