Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.8 L+₹4 L (25.4%)Rejected-AOC LOWER BAZAR SARKAGHAT DISTT MANDI H P | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected | |
| 4 | Rejected-Technical VILLAGE BIDDI P O DARWAR TEHSIL DHARMPUR DISTT MANDI H P | - | Rejected-Technical Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹20.3 L
EMD Value
₹37,875
Closing Date
26 Oct 2023, 5:00 pmClosed
Executive Engineer
Jal Shakti Division, Sarkaghat. Distt Mandi HP
Supply and Errection of Centrifugal Pump alongwith allied accessories 1st stage underJJM
2023_HPIPH_80298_1
8500-50 dated 16.10.2023
Open Tender
Civil Works
Item Rate
90 days
Sakaghat
.
8 documents required · 8 mandatory
₹400
Executive Engineer
₹37,875
Yes
Dharampur
5 Jan 2024
16 Oct 2023
27 Oct 2023
16 Oct 2023
26 Oct 2023
16 Oct 2023
25 Oct 2023
Amount
Centrifugal Pump Set for stage-1st:- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/ multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or any other make approved by JSV conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved Make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC ) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 269.78 mtrs Discharge required 10.72 LPS each set. No. of Pump required. 2.00 Nos sets (1 act as stand bye) Length of R/main 4890.00 mtrs. Dia of R/main 125 mm dia Location of the site of installation of machinery-The site is located at a Parnal of Km by road & 0.1 KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :- The Altitude of place is 500.00 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415 + 10% Type of water and its clear water Charactristics of water a) Ambient Temperature b) Turbidity < Than 50.00 NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 8 Hours. Limit of Pump In the complete of Range of (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 8 Hours continueously for 7 days.
Providing ICTP Main Switch with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB (1.00 No.)
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- (1.00 No.)
M.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments .(1.00 No.)
E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendment which should have control box operating handle and trip/reset push button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. (1.00 No.)
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). (1.00 No.)
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 ( Latest edition with up to date amendments of suitable rating. (1.00 No.)
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.(1.00 No.)
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments _____ Amp. (1.00 Set)
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. (2.00 No.)
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. (1.00 Set)
Supply of floor/wall mounted power factor Shunt Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 16 KVAR rating according to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments (2.00 Nos)
Providing suitable Auto Transformer of MEI/Kilburn make as per IS: 8544 (Part - ___)1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. (2.00 Nos)
Providing Hour run meter of recommended make as per IS: 722 (Latest edition) (2.00 Nos)
Providing double flanged Cast Iron sluice valve of Leader/Kirloskar make of 125 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 780-1984 with up to date amendments.(PN:1.0) (2.00 Nos)
Providing double flanged Cast Steel sluice valve of Leader/Kirloskar make and size of 100 mm dia. and capable of with standing nominal seat pressure of 52.00 kg/cm2 as per IS:1414/API-600 (Class ASA-300). (2.00 Nos)
Providing double flanged Cast Steel reflux valve of Leader/Kirloskar make and size of100 mm dia. and capable of with standing nominal seat pressure of 52.00 kg/cm2 as per BS-1868/API-600(Class ASA-300). (2.00 Nos) .
Providing double flanged Cast_Steel non return valve of Leader/ Kirloskar make and of 125 mm dia. having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52.00 kg/cm2 as per IS : 1868/API-600(Class ASA-300) (1.00 No)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 (2.00 Nos)
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. (2.00 Nos)
Installation of all the items appearing at Serial No. 3.00 to 9.01. (1.00 Job)
Providing and fixing double flanged __________ piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. (1.00 Job)
The size of the various components to be as under:- (i) Suction pipe 125 mm dia Min. length = 15 mtr. (ii) Delivery pipe 100 mm dia -do- = 5 mtr. (iii) Common Header 125 mm dia -do- = 10 mtr. and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Finolex/L&T make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: Suitable Size cable 25 mm² Min length = 20 mtrs. ( 20.00 Per Rmt)
(ii) Supply side: Suitable Size cable 50 mm² Min. length =10 mtrs. ( 10.00 Per Rmt)
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25.00 mm x 6.00mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. (1.00 Job)
M/S Anil Trading And Engineering Works
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .