| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹16.8 L+₹93,530 (5.88%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹18.0 L+₹2.1 L (13.1%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹18.3 L+₹2.4 L (15.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹19.1 L+₹3.2 L (20.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
REPAIR IMPROVEMENT REPLACEMENT TO LT NETWORK AND OTHEER ALLIED CONNECTED WORKS AT ZONE I UNDER MIL STN SAMBA
2023_MES_604039_1
GE/SMB/T-39/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹50,000
Yes
1 Sept 2023
21 Jun 2023
22 Jul 2023
21 Jun 2023
20 Jul 2023
6 Jul 2023
21 Jun 2023 - 23 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables, poles & stay or other items and getting out soil in any type soil complete all as specifed.
Excavation in trenches not exceeding 1.5 mtr wide and exc. 1.5 m but not exceeding 3.0 mtr in depth for poles or other items and getting out soil in any type soil complete all as specifed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified
Sand cushioning to under ground electric cable a layer of 8 cm thick before laying the cable and stretching the cable and punned down to form a bed of 23 cm and second layer of 15 cm thick after laying the cable complete all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be of good quality as specifed and punned thickness shall be measured and paid.
Well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including use of necessary form works for rough finished surface complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping to poles including use of necessary form works for rough finished surface complete all as specified and directed.
Supply & errection steel tubular swaged poles type 410 SP-31 (9 meter long) with 300mmx300mmx6mm MS base plate continuously welded to pole, finial taper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint (black and white/yellow) from ground level/coping upto 1.5 m painting with two coats of aluminium paint for the remaining height complete all as specified and as directed. (Note : Excavation & earth work, GI Pipe shall be measured and paid for separately under respective items of BOQ).
Structural steel work conforming to grade Fe-410S as in cross arms bracing supports clamps, back plates fabricated from steel section including nuts, bolts and washers welding, drilling hole, complete with two coats of aluminium paint over one coat of primer, complete all as specified and directed.
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 120 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 95 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 70 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 50 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 35 sqmm, 3.5 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 25 sqmm, 4.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 16 sqmm, 4.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 16 sqmm, 2.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
XPLE under ground cable, insulated screened PVC bedded galvanised steel strip/ wire armoured, electric power cable heavy duty 1100 volts grade of size 10 sqmm, 2.0 core with stranded aluminium conductor including proper connection with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables,complete all as specified and directed by Engr-in-charge. (Note – Necessary excavation, returning filling in,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of BOQ).
Material and labour for GI tubing light grade for passing through cables under the floor, along the wall, along the pole 40 mm bore completed all as sepcified and directed
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick not less than 6.0 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, connected to galvanised steel strip 32x6 mm by means of nuts, bolts, washers, check nuts of GI steel all as shown in electric plate no. 3 all as specified and indicated complete and including charcoal dust and salt etc and GI protection pipe, medium grade 40mm and GI watering pipe 20mm, medium grade with funnel and wire mesh, 15 mm thick Pre-cast RCC M-15 (Nominal mix) cover reinforced with XPM weight not less than 4 kg/sqm with suitable handle of 6 mm dia MS bar and angle iron 40x40x3 mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil, returning, filling in and removal of surplus soil and connected work, complete all as specified and directed.
Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia complete all as specified and directed.
Replacement loop type insulator, vitreous porcelain, white brown or green with overall dimensions 65x90 mm clearance of hole 16 mm including dismantling old unserviceable insulator, complete all as specified and directed.
Replacement shackle type, procelain, vitreous, white, brown or green insulator including one galvanised iron steel straps, washer and insulator bolt dia 12 mm , washers, nuts one galvanised iron nut 75 mm height, 90 mm dia for 1100 volts grade including dismantling old unserviceable insulator, complete all as specified and directed.
Galvanized stranded stay wire of size 7/4.00 mm including necessary binding with insulator, clamp and stay clamp, complete all as specified and directed.
Taking down existing unserviceable /retrived old ACSR conductor from over head lines, complete all as specified and directed.
Aluminum conductor steel reinforced (ACSR) for LT lines on steel tubular poles/PCC poles, streching without kinks and bends including aluminum binding wires of suitable size of conductor as per load, complete all as spd and directed .
Junction box suitable for LT PCC/Steel poles for street light 3 phase, 415 volts made out of 3.15 mm thick CRCA sheet with front openable doors including 04 nos aluminium busbar of 63 Amps current carrying capacity and one MCB SP 6 Amp mounted on din rail insulator, complete all as specified and directed.
Replacement of LT busbar chamber box of minimum size 90 cm (height) x 70 cm (width) x 45 cm (depth), outdoor type double door type, front / rear opening type suitable for 415 volts, 3 phase, 4 wire (100% neutral), 50Hz supply system, Box made out of 3.15mm (outer) & 2mm (inner compartment door) CRCA sheet factory made weather proof, dust proof and vermin proof duly powder coated with 04 nos , Make- Hindalco, aluminium busbar 100 Amps, 50 cm each (each busbar having 04 nos of nuts, bolts, washers) horizontally place in insulator suitable for lackable door arrangment complete with inter connections with aluminium solid strips, busbar chamber having 4 nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space from, complete all as specified and directed. Note : Panel shall be of front / rear opening with cable entry from the bottom.
Providing 90 Watt LED fitting made up of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete including 2 RM, 2 core, 1.5 Sqmm copper wire for each light fitting etc including taking out old U/S damaged street light fittings , complete all as specified and directed.Make-Havells Cat Part ENDURAPEARLPLUSSL 90WLED757PASYTOPCASTHO or Technocommercially euivalent in Polycab/C&S Electric/Halonix/HPL/Surya/WIPRO.
Providing 60 Watt LED fitting new generation energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddedPC cover with IP66 protection and impact resistance of IK07 complete including 2 RM, 2 core, 1.5 Sqmm copper wire for each light fitting etc taking out old U/S damaged street light fittings, complete all as specified and directed. Make- Havells Cat Part ENDURAPEARLNEOSL60WLED757PASYTOPC or Technocommercially euivalent in Polycab/C&S Electric/Halonix/HPL/Surya/WIPRO.
Providing 35 Watt LED fitting energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and impact resistance of IK07 complete including 2 RM, 2 core, 1.5 Sqmm copper wire for each light fitting etc taking out old U/S damaged street light fittings, complete all as specified and directed. Make- Havells Cat Part ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or Technocommercially euivalent in Polycab/C&S Electric/Halonix/HPL/Surya/WIPRO.
Providing LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver taking out old U/S damaged street light fittings . Make:- Havells cat part No. JETAIRISFLS 100WLED757APWBLT G or Technocommercially euivalent in Polycab/C&S Electric/Halonix/HPL/Surya/WIPRO.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Bharat Builder
M/S HIMANSHU BUILDERS
Jiwan Singh
dinesh enterprises
A K JAIN AND SONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .