Superintending Engineer (CG), GIDC, Bharuch.
Design, Engineering, Supply, Installation, Testing and commissioning of Non Clog End Suction Type Horizontal Centrifugal Pump Set for effluent with accessories and allied Electro-Mechanical and Instrumentation and SCADA work at Dahej PCPIR Pumping Station at Dahej - II. (Suva Village).
327883
E-Tender Notice No. 04 of 2026-27 Sr. No. 06
Open
Mechanical - All
Works
Bharuch
2 documents required · 2 mandatory
₹7,080
Executive Engineer, GIDC, Bharuch
₹5.0 L
27 Jul 2026
27 Jul 2026
27 Jul 2026
3 Aug 2026
27 Jul 2026
NAME OF WORK: Design, Engineering, Supply, Installation, Testing and commissioning of
"Non Clog End Suction Type Horizontal Centrifugal Pump Set for effluent"
with accessories and allied Electro-Mechanical and Instrumentation and
SCADA work at Dahej PCPIR Pumping Station at Dahej - II. (Suva Village).
TENDER NOTICE NO.04 OF 2026-2027 SR.NO.06
VOLUME -III: PRICE BID
ONLINE TENDER PAPERS
1 Estimated cost (Excluding GST) : Rs.4,95,10,474.00
2 Tender fee Incl. GST : Rs.7,080.00
4 Last date on (or before) which the tender along-with DD : From 13th July 2026 to 03rd
/ FDR for Tender fees & EMD (by scanning) and other August 2026 upto 17.00 hours
required documents must upload on the web site of
www.tender.nprocure.com
5 Date on (or before) which DD/FDR in original for : From 4th August 2026 to 6th
Tender fee & EMD and other required documents must August 2026 upto 17.00 hours
reach in the office of the EXECUTIVE ENGINEER (M&E)
2nd FLOOR, NARMADA COMMERCIAL COMPLEX, ABOVE
CENTRAL BANK, M.G.ROAD, PANCH BATTI, GIDC,
02642 – 241902 ) E-Mail:- xenme-
6 Opening of Technical Bid In the Office of Superintending
Engineer (CG), GIDC, Bharuch, 2nd
floor, Narmada Commercial
Complex, PanchBatti, Bharuch as
under: - Preferably On dtd. 07th
August 2026 at 12:00 noon.
7 Eligible class of Registered : Bidder should be as per
Prequalification criteria for Work-
(2.1) Eligibility and Having similar
EXECUTIVE ENGINEER (M&E)
2nd FLOOR, NARMADA COMMERCIAL COMPLEX,
ABOVE CENTRAL BANK, M.G.ROAD, PANCH BATTI, GIDC, BHARUCH.
E-Mail:- [email protected]
Signature of Contractor Executive Engineer (M&E)
Name of Work: Design, Engineering, Supply, Installation, Testing and commissioning of "Non
Clog End Suction Type Horizontal Centrifugal Pump Set for effluent" with accessories and allied
Electro-Mechanical and Instrumentation and SCADA work at Dahej PCPIR Pumping Station at
Dahej - II. (Suva Village).
Sr. Description Qty Unit Rate(Rs) Amount(Rs)
1 Supply, installation, testing & 6 Set 6,41,502.51
commissioning of Non Clog End
Suction type Horizontal
Centrifugal Pump set for effluent
of required capacity & head with
suitable TEFC squirrel cage foot
mounted induction motor (with
minimum IE-3 efficiency class),
working on three phase 50 Hz ±
3%, 415 V ± 10% AC supply,
RPM synchronous speed along
with base frame, coupling with
guard, foundation bolts, strainer
etc. complete set as per relevant
IS & following M.O.C: Casing:
to 2% Ni. CI; Impeller & wearing
ring: SS-CF8M, Shaft with sleeve:
SS & Base frame: CI, Guide Pipe:
SS. Liquid: Industrial Effluent
Flow 455 m3/hr, Head = 77.0 m
Motor Rating = 170.0 KW,
Pump Efficiency Min. 66.0%,
Motor Effi. Min. = 96.0%,
Rated speed: . 1485 RPM
Operating voltage: 415 V 50 Hz
Starting method: DOL / SD / VFD
(or higher rating as per pump
manufacturer recommendation)
Selection of motor kw rating if
not available in this rating, next
higher rating will be consider
2 Design, Engineering, 6 Nos. 66,029.76
procurement, Installation, Testing
and commissioning of required
size double flanged Dual Plate
Check Valve (DPCV) - (PN 1.6) -
350 mm dia (At Pump Discharge)
Flanged Dual Plate Check Valve
(NRV) conforming to API 594 /
Signature of Contractor Executive Engineer (M&E)
598 PN 1.6 with Cast Steel body,
withSS 410 hinge ring and
wearing ring of CF8 all necessary
hardwares, complete as per data-
sheet & specification. Size :
mm dia( PN 1.6) flanges
machined faced and drilled to IS :
1538 / 1976 Part-IV/VI.
Hydraulic tests certificate &
certificate of material of
construction of parts shall be
submitted before despatch of
valves as per design with
required acessories, erection
hardware, necessary mounting
supports etc. complete. 350 mm
dia for various pumps.
3 Supply, installation, testing & 6 Nos 13,453.20
commissioning of flange ends
Expansion Bellow as per EJMA
standards of overall length of
minimum 300 mm, designed for
15 mm axial compression and
mm axial extension with tie rods
etc. of following MOC & pressure
ratings.MOC: Bellows: SA 240 Gr.
304; Internal Sleeve: SA 240 Gr.
304; Weldends: IS 2062 Gr. B;
Flanges: IS 2062 Gr. B (Drilling as
per IS 1538 / IS 6392 ) & Limit
Rods & Nuts: CS - IS 1367. PN
Rating 1.6, 350 mm Dia.
4 SITC of Cast Steel D/F Electric 6 Nos 4,39,350.00
Actuator operated Sluice Valve of
following size as per API-
600/598,Class 150 with Electric
Actuator with integral starter &
IP-68 enclosure, body, bonnet
and wedge of Cat Steel Gr. WCB
with Body & Seat ring of ASTM A
216 Gr CF8M, spindle of SS
flanges drilled to ANSI B 16.5 of
following diameter along with all
other necessary hot dipped
galvanised hardwares, bolts, nuts
& washers, gaskets including all
taxes, insurance, transportation,
freight charges, Inspection
Charges, loading unloading,
conveyance to pump house,
Signature of Contractor Executive Engineer (M&E)
stacking, security with required
plain cement concrete (PCC)
support for Valves etc. within
pump house for fixing valve etc.
complete as per Specification and
Size : Dia. 350 mm
5 Design, Engineering, 1 Nos 6,22,335.44
procurement, Installation, Testing
and commissioning of fixing in
position and jointing of 600 mm
dia cast steel temper proof
Kinetic Double Orifice Cast Steel
Tamper Proof non- temper Air
release valve PN1.6 type flanged
ends high performance CI air
valves with Isolating Sluice
valves for water combination
type (Air release valve non
temporing type) having double
ball, double orifice with stainless
steel ball, tamper proof air vents
rolling seal mechanism for air
release and anti vacuum
application designed for
kg/cm2 working pressure and
tested for 20 kg/cm2 pressure,
having flat faced flanges and
drilled to IS : 1538 / Part-IV /VI.
Hydraulic tests certificate &
certificate of material of
construction of parts shall be
submitted before despatch of
valves. (Rate to include cost of
gaskets, bolts, nut and any other
materials required for jointing
and its transportation etc.
including all taxes and duties.with
required acessories, erection
hardware, necessary mounting
supports etc. complete.
6 SS-316 PIPE & Fittings 120 Mtr 26,124.66
Supply, cutting, welding,
installation, connection with main
header, testing and
commissioning of SS 316 pipe
and Fittings and Specials like
deg. Bend, Drilled / Blind Flanges,
Reducer / enlarger, Tee, etc. for
suction/delivery and header lines
Signature of Contractor Executive Engineer (M&E)
conforming to ASME, SCH 10 with
connection/welded and with
required plain cement concrete
(PCC) support for Pipe lines and
specials, etc. in pump house with
material & labour for pipe
fixing/laying for
delivery/suction/header line etc.
as required complete as per
specification and IS. Dia 350 mm
7 Do but 600 mm dia. 20 Mtr 19,343.52
8 Supply, welding, installation, 48 Nos 16,648.84
testing and commissioning of SS
316 flanges of required sizes,
conforming to ANSI/IS, Class
with, off center bolt holes along
with all required hardware,etc. as
required and including cutting of
pipes & specials as required to
weld flanges as per specifications
Size : 350 mm dia- Drilled (or as
per actual pump delivery size)
9 Do as above 600 mm 4 Nos 16,648.84
10 SITC of suitable size of above 20000 Kg 58.58
pipes of flanged end type
fabricated DI/MS Specials like
tee, bend, duck foot bend, tapper,
distance pipe piece, blank flange,
dismentling joint, bolts, nuts,
washers, rubber packing etc.nut
bolts etc for delivery header,
rising main and suitable for above
pumps as per actual site
conditions & requirement qty. of
specials mentioned as per deisng
requirement with required
acessories, erection hardware,
necessary mounting supports etc.
complete upto 350 mm dia and
11 Do as above 600 mm 1000 Kg 58.58
12 Single Girder EOT Crane 1 Set 6,14,332.50
Supply, installation, testing &
commissioning single girder type
fully electrically operated EOT
crane with electrically operated
Signature of Contractor Executive Engineer (M&E)
hoist, class II duty, geared
travelling trolley with seven
meter lift complete with long
travel rail track (40 mm sq. bar),
moving or cross girder, all
three motions electrically
operated by suitable rating motor
IP 54, control panel & down
pendant control block, brake,
safety device, cables form motor
to starter panel & other required
accessories & tested as per IS
Specifications.
Capacity- 5 T, Span- 6-9 Mtr, Long
Travel- 12 Mtr, 6-10 Mtr
13 SITC Chain Pulley block of 3 ton 2 Nos 14,544.00
capacity, lift as per site condition
with gantry girder, erection
hardware, necessary mounting
supports etc complete.make as
14 Supplying & fixing Steel 150 Sq. 5,780.23
Chequered Plate having 12 mm Mtr
thickness, duly painted with two
coats of black Japan colour.
(Average Wt 200.3 kg / Sq.Mtr)
15 DEWATERING PUMP 2 Nos 1,47,811.48
Supply, erection, testing and
commissioning of non clog
submersible Drain Pump with CI
casing & CF8M impeller,including
necessary accessories and
hardwares, etc., 15m cable for
motor to starter panel, suitable
for 3Phase, 415 V, 50 Hz AC
supply and min. 2.2 kW motor,
Switch-Starter panel with
suitable inter lock for winding
protection, min. 10 m long
required size cable to supply
power to control panel from
nearby power source, moisture
controlar along with level
switches for dry run protection
for auto stop facilities, cable
termination junction box of
required terminal size,
supporting arrangement for
pump and other required
Signature of Contractor Executive Engineer (M&E)
Capacity : 10 - 15 m3 / hr.
( to be installed in dry well drain
16 Tools as per Annexure (M) and as 1 Lot 2,52,500.00
recommanded by manufacturer.
17 Design, Supply, Installation, 1 Nos 44,37,252.70
Testing and Commissioning of
Power cum Motor Control Centre
of 800 A, 415, FP , Power Cum
Motor Control Centre (PCC)
cubical having throghout the
required length & detachable,
fabricated from 2 mm( All Load
Bearing structure and Doors )
CRCA sheet steel, free standing,
compartmentalized, extensible,
dust and vermin proof enclosure
( Min IP 54 ), duly painted
provided with required rating
switch gears and shall be
complete with (a) required size of
FP Electrolyte 800 A Copper bus
bar having cross section not less
than 1.4 Amp per 1.0 Sq. MM, (b)
3 Nos. - 800 Amp capacity of
pole- EDO microproccessor based
Air Circuit Breaker with RS 485 /
RS 232 computer interface (2
Nos. for incomer + 1 No. as Bus
Coupler) (c) 2 Nos. - 800 Amp
capacity of 4 pole - EDO
microproccessor based Air Circuit
Breaker with RS 485 / RS
computer interface (1No. for
D.G.Set & 1 No. for bus coupler) -
All release of all ACB should have
in built power meter/ analyser
having, 3 phase, V, KW, I, KVA,
KVAh, KVArh, PF, Frequency,
harmonic analysis up to 30th
harmonic and last ten faults
history.with RS 485 / RS
computer interface facility and all
other required protection etc.,
complete. ,The PCC shall be
supplied as per detailed
specifications & single line
diagram (SLD) complete and the
Signature of Contractor Executive Engineer (M&E)
instruction of Engineer In charge.
OTHER OUTGOING : 1. APFC
Feeder 630 Amp 3P+N MP based
MCCB with LSIG Protections - Min
36 KA - 2 Nos 2. 100 Amp 4 Pole
36 KA OG for Lighting and Misc.
load - 8 Nos 3. 30 Kvar Fixed
capacitor feeder for Tr. No load
compensation - 2 Nos and
actuator for motor and header
200 KW 6 Nos VFD with 400 Amp
The VFD unit shall have modular
construction, 6 pulse Bridge
rectifier speed control by means
of sensorless vector control (open
loop) high torque at low
frequencies, looking at high and
low frequency settings. In built
PID control, frequency accuracy
of +- 1 % ( min ) frequency
resolution of +- 0.1 Hz ( Min)
protection against : a). Overload (
Motor and Drive ) b). Short
Circuit (c) Ground Fault (d) Input
/ Out Phase loss ( open circuit)
(e) Stalling (f) Input / Out put
under voltage ( momentary
power loss restart . (g) In put
Out put Overvoltage h). Over
Frequency (i) In put Surge (j)
Over Temprature of heat sink . (k)
Loss of remote speed signals etc.
The VFD shall also have user
friendly programming for I/o's,
speed search function, copy
parameter ( Up loaded / Down
Loaded ) to other identical unit,
turning to Energy saving Mode (
Maximum Efficiency ) Event /
Fault recording ( last 5 Faults in
non volatile memory & RS
communication port ( Modbus
RTU) protocol with required
software) with input filter and
out put filters as recomended by
OEM as per manufacture design.
One Hour meter of each motor
feeder shall be required to
Signature of Contractor Executive Engineer (M&E)
The PMCC shall be fabricated &
assembled @ approved
manufacturer having valid type
test certificate as per LATEST IEC
61439 ( Minimum : 65 KA fault
level and Temprature rise test )
and latest ISO 9001. All
switchgears shall be used as per
approved vendor list. The
protection and monitoring
parameter should be remotely
adjustable, when used with
communication features. The
separate indication for overload,
earth fault, over voltage, under
voltage on release with self-
power generated so it must show
on which type of fault, the
breaker tripped even in case of
input power not available. ACB
and MCCB ICU=ICS. MCCB shall be
double break with roto acting
mechanism and as per detail
technical specifications.
The DGVCL approved make and
model TVM having facility of RS
485/ RS 232 and motor on off
time and power failure time
recording facility shall be
provided in the motor feeder.as
per relevent IS , Data sheet and
Tender specifications.
18 Supply, installation, testing & 1 Set 4383692.90
commissioning both side
extensible, Indoor type HV
Switchgear panel confirming to
IS-3427, IS-2516 (Part I & II.sec.1
100/200 for use on 3phase,
Hz, unearthed AC supply system
and having breaking/ ruptuing
capacity of 500 MVA (26.3 kA for
3sec) complete with spring
charged mechanism, ON-OFF
mechanical push button,
operation counters,
Breaker TNC switch, Breaker L/R
switch, necessary auxiliary
switches, closing coil, shunt trip,
Signature of Contractor Executive Engineer (M&E)
protection relays & Indicators
The panel shall comprise of air
insulated busbars provided with
heat shrinkable PVC sleeves. The
VCB trolley shall comprise of
three vacuum interrupters with
epoxy support insulators and self
aligning finger type isolating
contacts and necessary
mechanical interlocks, safety
shutters, isolating plugs.
Enclosure shall be openable from
front as well as rear end. The
breaker shall be Manual cum
motorised mechanism with
following accessories.
a) 96 x 96 mm square flush
mounting type Ammeter & Volt
meter with selector switches
b) Multi function meter
c) Double core, cast resin type
current transofrmer having ratio
as per requirement, one core for
metering & one core for
protection having required class
d) Instantaneous under voltage
relay & Temperature rise tripping
e) Triple pole IDMTL two over
current and one earth fault relay
with current setting range 50-
f) Electrical closing. coil & shunt
trip coil operating on 110 V DC.
g) Auxiliary relay for anti
pumping device.
h) Three limb, drawout type,
feeder connected, cast resin
insulated, three phase Potential
transformer having ratio &
burden as per reqirement & Class
i) Annunciator Windows,
Common Hooter / Alarm bell
operating on 230 AC/ 110 V DC.
j) Cable boxes suitable to
terminate 3 core XLPE cable of
required size (As per design).
Signature of Contractor Executive Engineer (M&E)
k) 230V AC to 110 V DC power
pack for closing & tripping circuit
l) Breaker ON-OFF, Auto trip and
spring charged indicators.
m) Phase indicating & panel
illumination lamps with plug
n) Space Heater with Thermostat.
11 kV HV Switchgear Panel-
Comprising of 800 A Vacuum
circuit breaker for 2 nos. Incomer,
1 no. Bus coupler, 8 nos. O/G
feeders for Motor Soft Starters,
nos. O / G for 11 / 0.433 kV
Auxiliary transformers.
19 Design, Supply, Installation, 1 Nos 6,54,154.78
Testing and Commissioning of
APFCR panel @ Dahej II , 415V,
50 HZ , 200 KVAR shunt
capacitor with Filter control
module / APFC relay mounted in
enclosure from 2 mm CRCA sheet
steel free standing, floor
mounted, compartmetalized, dust
and vermin proof enclosure
having 2 mm thick sheet steel and
earth terminals duly painted
enclouser with capacitor unit
having 2 Nos, 10 mm earth
terminals and two externals,
three phase busbars of
Electrolyte copper supported on
epoxy insulator of adequete
rating and strips minimum
steps of APFC relay digital meters,
Indicating lamp.for power factor
improvement up to 0.999 lagging
with In comer MCCB, 7 %
detuned copper wound Filter set
comparising of 7 % detuned
copper wound Reactors
capacitors (APP type)
Thyristorised switcing Module
etc complete in all respect. as per
relevent IEC , Data sheet and
Tender specifications. and As per
drawing. make as per annex
400 KVAR: APFC panel consisting
following items.
Signature of Contractor Executive Engineer (M&E)
a) 800 A, 50 kA for 1sec. TP, MDO
type, ACB with TM based release
& accessories b) 0-800 A range
analogue ammeter of 96 x 96 mm
selector switch
cast resin type current
transformer d) Suitable rating of
MCCB/ MCB & Contractor for
each capacitor bank
e) Suitable rating APP type
capacitor banks (vacuum
impregnated with non-PCB / non
toxic oil, internally delta
connected with built in internal
fuses complete with discharge
resistances & terminal cover) of
approved make in required steps
with well suited detuned reactor
series with each capacitor step.
(e.g. 400 KVAR capacity will be
provided in steps of 2 nos x
KVAR, 2 nos x 10 KVAR, 2 nos x
15KVAR, 2 nos x
20 KVAR & 6 nos x 50 KVAR) f)
Enclosre dimensions: 2100 (H) x
20 Transformer 2 Set 12,07,001.51
SITC of outdoor type, three phase,
oil immersed, distribution
transformer of required KVA &
voltage ratio, copper double
wound, vector group - Dyn11, HV
delta connected & LV star
connected with neutral brought
out connected to provide
separate earthing terminals,
bushing / cable box on HV side
and cable box on LV side suitable
for cables or bus duct as per
requirement with standard
fittings, conforming to IS:
(Part-1) / 2014 with its latest
amendment including first fill of
transformer oil & following
(a) Oil conservator with filling
holes with cap and prismatic oil
Signature of Contractor Executive Engineer (M&E)
(b) Silica Gel dehydrating
breather charged with silica gel
(c) Oil drain cum sampling valve
(d) Oil filter valve
(e) Lifting Eyes / Hooks / Lugs
(f) Two earthing terminal
(g) Diagram and rating plate
(h) Air release plug
(i) Explosion vent with
(j) Thermometer pocket
(k) Four bi-directional plain
roller with base channel with
(l) Fixed / Separate type radiator
(m) Off circuit externally
operated tapping switch (For
rating < 1000 kVA)
(n) 100 mm stem type oil
temperature indicator (For rating
(o) Bucholtz relay with shut off
valve (For rating ≥ 500 KVA)
(p) 150 mm dial type oil
temperature indicator with Alarm
/ Trip contact (For rating ≥
kVA) (q) 150 mm dial type
winding temperature indicator
with Alarm / Tip contact (For
rating ≥ 1000 kVA) (r)
Marshalling box (For rating ≥
kVA) (s) 150 mm dia. magnetic
type oil gauge (For rating ≥
kVA) (t) Inspection cover &
Jacking lugs (For rating ≥
kVA) For transformer having oil
storage capacity for 2000 liters
and higher, nitrogen injection fire
protection system (NIFPS) is to
Effiency Level 3, Rating 800 KVA,
Maximum Total Losses (kW)@
50% Load /@ 100% Load /%
Impedance- 2.14/ 5.83/
21 Design, Engineering, 1 Nos 4,31,016.49
procurement, Installation, Testing
and commissioning of Lighting
Signature of Contractor Executive Engineer (M&E)
Distribution Board Distribution
board fabricated from 2 mm
sheet steel free floor standing
with one 415 V, 50 Hz TPN MCCB
as incomer and out going circuits,
including Electrolyte Copper bus
bars, metering unit lamps, timer
etc complete for lighting and
auxiliary power requirements. DB
complete as per specification,
single line diagram and
instruction of engineer In
charge.make as per annexure.
22 Design, Engineering, 1200 Mtr 1,542.27
procurement, Installation, Testing
and commissioning Power and
control cables 11 kV grade
aluminium conductors, UE, XLPE
insulated PVC sheatherd
armoured cable etc. 11 KV, 3C x
120 sq.mm. In transformer yard
cables shall be laid in cable trays
in RCC trenches with RCC
covers.make as per annexure.
23 Design, Engineering, 60 Nos 6,694.28
procurement, Installation, Testing
and commissioning Suitable size
Heat shrinkable cable end
termination kit for 11 KV, 3C
cable with weather proof double
comprission cable glands,
crimping type lugs, joints
supporting structure etc.Indoor
Type 120 Sq.mm as per cable
size.make as per annexure.
24 AS per above Outdoor type 120 20 Nos 12,840.13
sq.mm make as per annexure.
25 Design, Engineering, 240 Mtr 4,564.19
procurement, Installation, Testing
and commissioning XLPE ( IS
7098)(I) - 88 ISI marked
armoured cable multistrand
COPPER conductor for 1100 Volts
grade copper conductor XLPE
insulated, PVC sheathed stranded
armoured cable with bricks sand
cable route markers etc with
laying, glanding and termination
with suitable size lugs / nut bolts
with all required materials +
Signature of Contractor Executive Engineer (M&E)
labour. Cable shall be laid above
ground in cable trays installed in
over head cable trays. For
underground cables shall be laid
in cable trays in cable trenches.
For interplant cabling separate
cable rack / cable trench or
completed pipe cum cable rack
shall be used.make as per
annexure.minimum 1.1 kV, 3.5C x
185 sq. mm, XLPE insulated
armoured cable for LDB Panel
26 Design, Engineering, 115 Mtr 844.36
procurement, Installation, Testing
and commissioning XLPE ( IS
7098)(I) - 88 ISI marked
armoured cable multistrand
COPPER conductor for 1100 Volts
grade copper conductor XLPE
insulated, PVC sheathed stranded
armoured cable with bricks sand
cable route markers etc with
laying, glanding and termination
with suitable size lugs / nut bolts
with all required materials +
labour. Cable shall be laid above
ground in cable trays installed in
over head cable trays. For
underground cables shall be laid
in cable trays in cable trenches.
For interplant cabling separate
cable rack / cable trench or
completed pipe cum cable rack
shall be used.make as per
annexure.minimum 1.1 kV, 3.5C x
35 sq. mm, XLPE insulated
armoured cable for LDB Panel
27 Design, Engineering, 300 Mtr 1,415.01
procurement, Installation, Testing
and commissioning XLPE ( IS
7098)(I) - 88 ISI marked
armoured cable multistrand
COPPER conductor for 1100 Volts
grade copper conductor XLPE
insulated, PVC sheathed stranded
armoured cable with bricks sand
cable route markers etc with
laying, glanding and termination
with suitable size lugs / nut bolts
with all required materials +
Signature of Contractor Executive Engineer (M&E)
labour. Cable shall be laid above
ground in cable trays installed in
over head cable trays. For
underground cables shall be laid
in cable trays in cable trenches.
For interplant cabling separate
cable rack / cable trench or
completed pipe cum cable rack
shall be used.make as per
annexure.minimum 1.1 kV, 3C x
70 sq. mm, XLPE insulated
armoured cable 1 run for motor .
28 Do but 3 Core x 6 Sq.mm 150 Mtr 153.52
29 Do 3 Core 4 Sq.mm Pumps and All 365 Mtr 113.12
actuator operated Valves and
30 Design, Engineering, 200 Mtr 142.41
procurement, Installation, Testing
and commissioning XLPE ( IS
7098)(I) - 88 ISI marked
armoured cable multistrand
COPPER conductor for 1100 Volts
grade copper conductor XLPE
insulated, PVC sheathed stranded
armoured cable with bricks sand
cable route markers etc with
laying, glanding and termination
with suitable size lugs / nut bolts
with all required materials +
labour. Cable shall be laid above
ground in cable trays installed in
over head cable trays. For
underground cables shall be laid
in cable trays in cable trenches.
For interplant cabling separate
cable rack / cable trench or
completed pipe cum cable rack
shall be used.make as per
annexure.minimum 1.1 kV, 4C x
sq. mm, XLPE insulated armoured
cable for Lighting Distribution
31 Do but 4 C x 2.5 Sq.mm XLPE 350 Mtr 81.81
Insulated Armoured Cable for
Local Push Buttons.
32 Supply and Installation of Cable 4 Nos 173.72
end Termination of Power and
control cables including glands,
lugs etc complete in all respect
Signature of Contractor Executive Engineer (M&E)
for above cables.make as per
annexure. 3.5 core 35 sqmm
33 Do but 3 Core x 4 Sq. mm 28 Nos 64.64
34 Do but 3 core x 6 sq.mm 20 Nos 67.91
35 Do but 3 core x 70 sq.mm 4 Nos 101.00
36 Do but 4 core x 4 sq.mm 34 Nos 73.73
37 Do but 4 core x 2.5 sq.mm 500 Nos 73.73
38 Do but 3.5 Core x 185 Sq.mm 20 Nos 761.54
39 Providing & laying of 50 MM 200 Mtr 62.62
Nominal OD Doubled Walled
Corrugated Pipes (DWC) of
polyethylene (conforming to IS
14930 - II) with necessary
connecting accessories like
coupler, Tee, L - Bow, etc. of same
material at required depth (90
cms) including excavation for
laying of cable below ground/
road surface for enclosing cable
and back filling the same to make
ground as per original & as per
instruction of Engineer Incharge -
for Streelight Cable of 1 x 4 core x
16 Sq. MM and Service cable of
x 4 core x 16 Sq. MM -
40 Supplying and erecting 80 mm 140 Mtr 471.67
dia light duty "A" class GI Pipe
and erecting as directed by
Engineer In Charge.
41 Design, Engineering, 50 Mtr 471.67
procurement, Installation, Testing
and commissioning approved
make Perforated C type cable
tray. Made from pre- galvanized
CR sheet steel. The cable tray
should be bended as per IS
2062/1079 . with coupler plate /
Fish plate and GI hardware like
nut - bolt and washers etc.
erected on existing support as
per Specification and as per
instruction of engineer in
charge...Galvanised Iron Cable
Signature of Contractor Executive Engineer (M&E)
Trays.including necessary
supports, welding, insert plates,
etc complete with necessary
bends, tees gross, covers, reducer,
cover attachment, adjustable
elbow, connectors & y branch,
barrier strips and supporting
,erection hardware and
accessoseries.make as per
annexure. up to 300 mm x 50 x
42 Design, Engineering, 10 Nos 249.47
procurement, Installation, Testing
and commissioning of approved
make 'T' Junction for Perforated C
type cable tray. Made from pre
galvanized CR sheet steel. The
Junction should be bended as per
IS 2062/1079. with coupler plate
/ Fish plate and GI hardware like
nut - bolt and washers etc.
erected on existing support as
per Specification and as per
instruction of engineer in
charge..300 X50 X 1.5 mm thick T
43 Design, Engineering, 10 Nos 219.17
procurement, Installation, Testing
and commissioning of make '90°
Elbow' for Perforated C type
cable tray. Made from pre
galvanized CR sheet steel. The
Junction should be bended as per
IS 2062/1079. with coupler plate
/ Fish plate and GI hardware like
nut - bolt and washers etc.
erected on existing support as
per Specification and as per
instruction of engineer in charge..
300 X50 X 1.5 mm thick Elbow
44 Design, Engineering, 10 Nos 419.15
procurement, Installation, Testing
and commissioning of Lighting
System Internal Lighting –Point
wiring for Light with 2-1.5
sq.mm & earthwire of 1.5 sq.mm
(Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated
multistrand copper wires, in
following type of pipe to be
Signature of Contractor Executive Engineer (M&E)
erected concealed in/ on surface
on wall/ceiling complete with 6A
Modular type switch / bell push &
accessories and earth continuity
of following type, erected on PVC
/ Metallic box, single mounting
base frame covered with
textured/metallic front plate
modules erected on / in wall /
ceiling as per pipe erected, with
necessary Lamp holder/ceiling
rose / H.D.Connector as
directed.(a) with medium class
rigid PVC pipe and accessories.
Light Points Cat-III
45 Design, Engineering, 4 Nos 1,191.93
procurement, Installation, Testing
and commissioning of Point
wiring for FAN with 2-1.5 sq.mm
& earthwire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated
multistrand copper wires, in
following type of pipe to be
erected concealed in / flushed on
wall/ceiling complete with 6A
Modular type switch and hum
free EME four or more step type
electronic fan regulator with
separately mounted and
accessories with earth continuity
of following type erected on PVC
/ Metallic box, single mounting
base frame covered with
textured/metallic front plate
modules erected on / in wall /
ceiling as per pipe erected. with
necessary ceiling rose /
H.D.Connector as directed.(a)
with medium class rigid PVC pipe
and accessories. Cat-III
46 Design, Engineering, 4 Nos 241.39
procurement, Installation, Testing
and commissioning of Point
wiring for Looped Plug with 6A
Modular type switch & 5 pin
socket erected on PVC / Metallic
box, single mounting base frame
covered with textured / metallic
front plate modules erected on /
Signature of Contractor Executive Engineer (M&E)
in wall / ceiling with following
type accessories Cat-III.
47 Design, Engineering, 20 Nos 669.63
procurement, Installation, Testing
and commissioning of Point
wiring for Individual Plug with &
earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV
grade FRLS PVC insulated
multistrand copper wires, in
following type of to be erected
concealed in / on surface of wall /
ceiling complete with Modular
type switch & 5 pin Plug erected
on PVC / Metallic box covered
with appropriate front plate
modules erected on / in wall /
ceiling as per pipe erected with
following type of accessories.[II]
For 16A Plug with 2-2.5 sq.mm
Cu. Wire (a) with medium class
Rigid PVC pipe and accessories
48 Supplying and erecting 90 W LED 8 Nos 5,976.17
street light / Flood light fittings
with High power White LEDs
wattage of 3 Watt and above
assembled on single MCPCB,
efficiency more than 130 lm/w
and corrosion free High pressure
die cast aluminum housing with
smooth finish powder coated and
heat sink extruded aluminium
with diffuser and Polycarbonate
optics/ lenses, with toughened
glass with company mark/name
engraved or embossed 160 to
V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45,
Luminaire efficacy>
lumens/watt . LED driver
efficiency > 85 %.( fittings
required LM-79 & LM-80
certificates)(NOTE: Below
description have shown ranges of
Wattage capacity of LED
fittings.The Engineer incharge
may select any wattage capacity
between the ranges
Signature of Contractor Executive Engineer (M&E)
shown.)Street Light (IP-65),
Surge protection -4KV integral
and ,Light must have 440VAC line
supply with over-voltage
49 Supplying and erecting 120 W 8 Nos 6,566.01
LED street light / Flood light
fittings with High power White
LEDs wattage of 3 Watt and
above assembled on single
MCPCB, efficiency more than
lm/w and corrosion free High
pressure die cast aluminum
housing with smooth finish
powder coated and heat sink
extruded aluminium with diffuser
and Polycarbonate optics/ lenses,
with toughened glass with
company mark/name engraved
or embossed 160 to 270 V,Power
Factor more than 0.95, THD <
%, CCT 3000 K to
5700K,Uniformity ratio >0.45,
Luminaire efficacy>
lumens/watt . LED driver
efficiency > 85 %.( fittings
required LM-79 & LM-80
certificates)(NOTE: Below
description have shown ranges of
Wattage capacity of LED
fittings.The Engineer incharge
may select any wattage capacity
between the ranges
shown.)Street Light (IP-65),
Surge protection -4KV integral
and ,Light must have 440VAC line
supply with over-voltage
50 Providing and erecting Approved 8 Nos 3,459.21
make Ceiling fan with double ball
bearing ISI mark with condenser
sweep complete, canopy and
cms. down rod erected on
existing hook or clamp with
24/0.2 , 3 core flexible wire with
earthing. [Make shall be approved
by Engineer in charge]
51 Supplying & erecting Fan Hook of 8 Nos 43.43
10 mm M.S. Round bar grouted in
Signature of Contractor Executive Engineer (M&E)
RCC slab with Making the site as
52 Supplying & erecting fan hook 8 Nos 126.25
box of 10 mm M.S. round bar
bounded to the RCC bars up to
50mm length each side and
pierced through a 16 Gauge M.S.
box / Heavy Duty PVC box
complete erected concealed in
Ceiling with necessary finishing.
With 2.5 mm thick laminated
acrylic sheet to cover the fanhook
53 Supplying & erecting single phase 8 Nos 3,937.99
approved make industrial
exhaust fan suitable for medium
duty ring mounted low noise
operation suitable for medium
duty having following dia size and
maximum speed in RPM (A)
having 450 mm dia. Of 1400 RPM
speed. Cat - II
54 Providing & Erecting Mains with 200 Mtr 59.59
1.1 KV grade FRLS PVC insulated
ISI marked stranded Copper
conductor wire in following type
of pipe to be erected concealed in
/flushed on wall/ceiling, with
sq. mm copper conductor FRLS
PVC insulated stranded wire of
green colour for earth continuity
of following size (From DB to
Switch borad lighting Cicuit + 16A
power plug+ water cooler) (e) in
existing pipe. (B) 2 wire
55 Providing and erecting Sheet 2 Nos 8,223.42
Steel powder coated MCB
distribution board - flush /
surface mounted fitted with
busbar, neutral link, earth bar
and DIN rail, confirming to IS
13032 and BS 5486-1986 without
MCB to house appropriate nos. of
MCBs.(The DBs should be used of
same company of MCB to be
used) Three phase 8 way SS
double door for single phase out
going horizontal box.( 1 No. for
each floor lighting distribution)
Signature of Contractor Executive Engineer (M&E)
Providing & erecting of approved
make ELCBs /RCCBs confirming
to IS: 12640 and having
sensivitive of 30 mA and short
circuits withstand capacity of
6KA and suitable for operation on
three phase and neutral 415V
having characteristic of quick
action & tripping with all advance
feature & do not incorporate any
electronic component for 63 A FP
erected as directed.(Cat-III) ( I st
floor lighting DB + 1 no II nd floor
DB) Providing & erecting of
Miniatuer circuit braeker single
pole 6A to 32A suitable to operate
on 240 V A.C. system and having
having breaking capacity 10 KA to
be erected in existing box
confirming to IS 8828 /
with ISI mark (Cat-III).
56 SITC of SITC of 08.00 Mtr Hot Dip 8 Set 27,435.64
galvanised Octogonal type
Streetlight Pole complete without
Bracket & accessories but
provided/ fitted with item no. (a)
to (h) mentioned below with
their specifications and Detailed
Specification (a) Providing and
fixing approved make Octoggonal
poles made from CR Sheet steel.
The poles should be made as per
IS and shall be coated with hot
Dip galvansing as per IS
2629/4759 with required base
plate suitable suspended local
wind speed erected on existing
foundation 8 Mtr long 70 mm top
x 155 mm bottom dia 3 mm
thickness Along with base plate.
(a) Overall length of pole :
(b) Planting depth :
(c) Height above ground level :
(d) Length of section - Out side
dia. & Wall thickness 3 mm
Bottom : 175 mm
Signature of Contractor Executive Engineer (M&E)
(b) Providing of Reinforcement
Cement Concrete (RCC)
foundation of 550 MM W x
MM x 1500 MM Depth in M -
or As per OEM Design ( c) Supply
and Installtion of M 20 x 750 long
'J' type EN 8 grade foundation
bolts along with template for the
above poles (d) Supplying and
Erecting bakelite Sheet 12 mm
thick HYLAM make on existing
Iron Frame (e) Funnel Type Pipe
Earthing. (f) Decorative Single
Arm Bracket (g) 1.1 kV grade FR
PVC insulated ISI Marked
Stranded Copper cable having
Conductor 2 Wire 2.5 Sq. MM. in
exising pipe/ in street light pole
erected with 1.5 Sq. MM. copper
conductor FR PVC insulated
stranded wire of green colour for
earth continuity.
(h) 90 Watt LED Streetllight
57 Lightening protection system for 80 Kg 886.78
highest building at plant area by
air terminal with rod and GI strip
conductor test link to earth
electrode as per requirement .
58 Supplying & erecting 600 mm x 11 Nos 7,874.97
600 mm x 3.15 mm thk. Copper
earth plate earthing burried in
specifically prepared earth pit
mtr. below ground with 40 Kg.
Charcoal and 40 Kg. salt with
alternate layers of charcoal & salt,
38 mm dia Medium Class G. I.
Pipe with funnel with a wire
mesh for watering & bricks
massanary block, C. I. cover
complete as per para 7.3 of IS :
3043 with necessary length of
double 8 SWG copper earth wire -
bolted to the plate and covered in
38 mm dia. G. I. pipe - 2.5 mtr.
long complete connected to the
nearest switch gears with end
socket as per direction & duly
tested by earth tester confirming
to ISS & as per drawing .
Signature of Contractor Executive Engineer (M&E)
59 Supply and Installation of GI 500 Kg 77.77
Earth strips for earthing 50 x
mm abd or requuired size GI
Strips for earthing of OCB, VCB,
LT Poqwer Cum Moot Control
60 Safety equipments as per 4 Nos 130.29
specificatios. Printed instruction
chart Gujarati and English
61 hand gloves(HT) 8 Nos 214.12
62 12 mm thick corrugated rubber 4 Sq.mtr 3,081.51
mat As per the scecificatation
mm thickness IS 5424 and of
required size lnngth and Breadth
and good condition property for
63 Supplying stand first AID box 4 Nos 299.97
with antiseptic cream, medicine
for use on wounds due burn,
crepe bandage, gauge bandage,
medicated ready to use bandage
(Band-aid) adhesive tape for
medicinal user, Scissors, anti-
septic solution (Savlon or similar)
etc. (All above contents shall be of
standard makes)
64 Supplying FIRE bucket round 16 Nos 214.12
bottom of 9 litres capacity made
out of 24 gauge G.I. sheet with
extra handle at bottom duly
painted white inside and Red out
side with FIRE mark, filled with
dry-sand and kept on existing
stand provided or hung on wall
65 Supplying and erecting floor 4 Nos 942.33
mounting stand for keeping four
nos. of FIRE buckets comprising
1500 mm in length, 900 mm
height frame made out of 30mm
X30 mm X 4 mm angle iron with
cross supports for legs, welded
with 4 hooks and duly painted
with one coat of red lead and two
coats of approved enamelled
66 Wall hook 22 to 25 cms. 16 Nos 60.60
projection for keeping fire
buckets made out of 15 mm dia.
Signature of Contractor Executive Engineer (M&E)
M.S rod grouted in wall to a depth
of minimum 15 cms.
67 Danger notice boards Medium 40 Nos 69.69
68 Danger Notice Board for High 20 Nos 81.81
69 Supplying & erecting D.C.P. type 8 Nos 2,226.04
fire extinguisher for following
capacity cartridge type with gun
metal cap 150 gram CO2 gas
cartridge, powder and brackets
confirming to IS 2171 1985 and
complete erected with necessary
clamps made from 50 x 6 mm M S
Flat with nuts and bolts grouted
in wall complete. 10 kg.
70 Supplying & erecting carbon 8 Nos 8,671.86
dioxide (CO2) fire extinguisher
user of following capacity with
necessary clamps made from 50 x
6 mm M.S. Flat with nut & bolts
grouted in wall complete. For
5.5/6.5 KG Capacity
71 Test equipments as per tender 1 Lot 1,04,452.18
72 Providing and casting in situ C.C 40 Mtr 9,177.10
in grade M-20 ( portion as per
mixdesign or as per table 9 of IS
456 2000 in masses by weigh
batching ) using granite,quartzite
trap matel of size 6 mm to 20 mm
for RCC work includinh scafolding
, centering, formwork, needle
vibrated, consolidation curing
comp RCC structure, thrust block
for supporting of valves and
header line as per site
requiremetn and instruction of
Engineer Incharge inside pump
house .RCC cable tench with RCC
cover for laying of cables from
panel to Pump room and DP
structure to Panel room width
mtr x 1 mtr indiside and 0.15cm
thick vertical, top and bottom.
73 Providing and casting in situ C.C 53 M3 11,110.95
in grade M-20 (portion as per
mixdesign or as per table 9 of IS
456 2000 in masses by weigh
batching ) using granite,quartzite
Signature of Contractor Executive Engineer (M&E)
trap matel of size 6 mm to 20 mm
for RCC work includinh scafolding
, centering, formwork, needle
vibrated, consolidation curing
comp RCC structure, thrust block
for supporting of valves and
header line as per site
requiremetn and instruction of
Engineer Incharge inside pump
74 SITC of 0- 10 kg / cm2 - 150 mm 9 Nos 1,426.12
dia, size Pressure Gauge with
siphon & cock and glysrin filld
type as per IS specification with
SS ball valve, SS hex nipple,
hardwares etc. as per the
direction of engineer incharge
(Pressure Guage fixing in each
pump set & header pipeline).with
required acessories, erection
hardware, necessary mounting
supports etc. complete. as per
relevent IS , Data sheet and
Tender specifications make as per
75 Supply, installation, testing and 9 Nos 29,438.47
commissioning of Pressure
Transmitter with local display
along with two valve manifold,
required fittings, tubing (all
valves, fittings, tubings, etc. shall
be in SS 316 only), all
accessories, hardware, etc.
complete in all respects as per
specifications and having
following measurement ranges:
Range : 0 - 10 Kg/cm2 (at each
pump delivery side and Pump
76 LEVEL MEASURING SYSTEM FOR 9 Nos 60,030.36
Supply, installation, testing and
commissioning of Ultrasonic type
Level Transmitter with remote
type transmitter with 20 meter
cable between Sensor and
Transmitter along with all
required accessories, Weather
proof enclosure for transmitter
for outdoor application, mounting
Signature of Contractor Executive Engineer (M&E)
stand , etc. complete in all
respects as per specification and
having following measurement
ranges for liquid (Effluent)
Meas. Range: upto 10 m
77 Supply, installation, testing and 12 Nos 12,930.02
commissioning of Displacer type
Level Switch SS Float for dry run
protection of pump through relay
multiplication in PLC), etc.,
complete in all respects and as
per specification.
Meas. Range: upto 10 m
78 ELECTRO MAGNETIC 6 Nos 3,06,254.22
FLOWMETER MAINS OPERATED
Supply, installation, testing and
commissioning of Full Bore
Electromagnetic flow meter
comprising of IP-68 Sensor with
PTFE liner , Hastelloy-C
Electrode, IP-66 transmitter with
20 m cable between sensor and
transmitter along with all
mounting accessories, Weather
proof enclosure for transmitter,
hardware, mounting stand, etc. as
per specification and to complete
the work in all respect as per site
condition necessary connection
with pipe and shall have
following size.
Meter Size : 350 mm NB
79 Do as above for Meter Size : 600 3 Nos 3,52,319.31
80 SITC of IoT based Gateway device 1 Nos. 1,20,000.12
for interfacing of flow meter
installed at various industries, as
well as GPRS based wireless
communication with cloud based
SCADA for overall monitoring
having following features at the
1 - 230 VAC and Battery operated
2 - Notification of 230 VAC Power
3 - Built in SD Card based data
storage for 5 years
4 - Built in RTC with GSM sync
Signature of Contractor Executive Engineer (M&E)
5 - Remote GPRS Connectivity
6 - Local Wi-Fi Connectivity
7 - IoT based Communication
8 - Ethernet connectivity with
battery powered
( better battery power life of
continuous operation, with one to
one battery shall be replace by
bidder at the time of any kind of
fault during the project period)
with data transferring speed as
per requirement.
81 SITC of M2M SIM cards with 2 Nos. 1,247.35
Postpaid connections with (5
GB/Month) data plan valid for
years as per requirement.
82 Design, Engineering, 1 Lot 23,46,785.50
procurement, Installation, Testing
and commissioning PLC and
SCADA System PLC and SCADA
system for the Procees and
Electrical parameter monitoring,
flow meters, level, pressure
transmitters, Energy meters,
Transformer, VFD.etc supervision
and control provided as per the
site requirements and All
Instrumentation equipment as
per the as per relevent IS , Data
sheet and Tender specifications.
Cloud based SCADA software
with hosted server having
following features at the
minimum with 5 years hosting
and maintenance charges:
1 - Cloud based Metering as well
as SCADA Software with
2 - 5 Years hosting & Software
charges including GPRS SIM card
3 - GPS/GIS with Google Maps
4 - Map based dashboard with
color indications
5 - Plot wise water consumption
report generation based on tariff
6 - Mobile app for notifications
Signature of Contractor Executive Engineer (M&E)
7- SCADA Software shall be
capable of monitoring at least
minimum 1000 flowmeters or
Pumping Staion and data field
devices As per site requirement
for ESRs and flowmeter
connections with future 50%
SCADA System Operator PC with
latest configuration for Overall
monitoring of the Network,
having following features
1 - Operator PC with latest
configuration of I5 or above and
22" monitor, UPS, - 02 nos
2 - Laser printer - 1 nos
3 - Table (01) and Chairs (04)
4 - Bidder has to provide all
networking equipments or
Internet connection devices only
Internet connection shall be
provided by GIDC for Engineering
& operator work station as per
specification and datasheet.
Billing for that internet
connection will be borne by
83 INSTRUMENT CABLE 80 Mtr 145.44
'Supply, Laying, Installation,
Connection, Termination, Testing
& Commissioning of Instrument
Cables as per specs.
The unit rate shall include
a)Supply, loading & unloading of
the cable at site from store.
b)Shifitng of cable from site store
to place of installation.
c)Fixing of cable clamps, brackets,
supports, route markers etc.
where ever required to fix the
d)Excavation, back filling and
levelling of ground alongwith
laying of fine sand, protection
bricks and other necessary civil
material for laying cables outside
f)Testing and submission of
sketches & reports of all the
Signature of Contractor Executive Engineer (M&E)
84 SIGNAL CABLE 80 Mtr 120.19
85 CONTROL CABLE 80 Mtr 273.71
86 INSTRUMENT CABLE TRAY 100 Mtr 840.32
Supply and installation / erection
of Perforated type cable tray of
galvanized mild steel sheets of
mm thickness with required,
hardware, fitting and support
structral asccessories . All
material shall be Hot dip
galvanised as per IS 2629 and
tray hardware shall be in GI.
Support structutre shall be of
structral steel for mounting the
cable tray on wall / cable trench
or as per site condition,
600 X 25 mm - Perforated type
87 200 X 25 mm - Perforated type 100 Mtr 325.22
88 50 X 25 mm - Perforated type 100 Mtr 109.08
89 CABLE END TERMINATION AND 40 Nos 137.36
'Supply, fixing, connection, testing
and commissioning of double
compression brass cable glands
and crimping type Bimetalic lugs
/ sockets with necessary tools
and equipments as specified in
specifications and IS complete in
all respects. The glands and lugs
/ sockets shall be suitable for
cable size and type mentioned
above. The job also includes
earthing the glands and armour
of the cable with common earth
bar or flexible copper mesh as
90 SIGNAL CABLE 45 Nos 137.36
91 CONTROL CABLE 35 Nos 299.97
92 Online Influent Monitoring 1 Nos 47,65,852.90
System Including Centralize
Signature of Contractor Executive Engineer (M&E)
Monitoring System and Provision
to Data Connectivity to GPCB and
CPCB. Technology: UV-Vis Entire
Spectrum Technology (200nm-
720nm). MOC: Titanium for COD
BOD TSS and SS316L for pH TDS
NH4-N and NO3-N. Cleaning
Method: Ultrasonic Cleaning with
Air Cleaning. Remote Access
Facility Must be Available and Its
Should be Cover with Digital
Locking System.
93 Comprehensive O&M&R for 60 60 Month 73,605.00
Months work Including
manpower for operation 24 x
days 365 days, maintenance, any
reagents & consumables, spares
for all pump station, Automatic
system or all system installed
under this work as Follow the
Technical Specification as the
Technical Bid Document and
*The rate shall be Exclusive of all taxes (Excluding GST)
I/We agree to carry out above work at __________ % above the estimated Rate put to tender
Percentage in words ( _______________________________)
I/We agree to carry out above work at __________ % below the estimated Rate put to tender
Percentage in words ( _______________________________)
Estimated Amount put to Estimated Amount put to
Tender Rs. 4,95,10,474.00 Tender Rs.
Add % Above Rs.____________ . Deduct % Below Rs.____________
Net Amount Rs.____________(In figures). Net Amount Rs.____________(In figures)
I/we have read the condition mentioned in this tender and agree to abide by the same.
Signature of Contractor Executive Engineer (M&E)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bank Guarantee.pdf
Volume - I (PQ).pdf
Volume - II (Technical Bid).pdf
Price bid.pdf
B1 Agreement - Part 1.pdf
B1 Agreement - Part 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .