Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | ₹5.1 L | L1 | Accepted-AOC Single |
Tender Value
Refer Docs
EMD Value
₹12,628
Closing Date
15 Jul 2023, 5:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
O/o ASSISTANT EXECUTIVE ENGINEER, PWD ELECTRICAL SUB DIVISION, IDUKKI, PAINAVU P.O, PAINAVU-685603
DEPOSIT-SITC of DG sets in various courts in Idukki district-Providing Diesel Generator set in court complex ,Idukki-General Electrical Work
2023_PWD_578262_4
PWD/BLDG/TR/8503/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
70 days
IDUKKI
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,115
₹12,628
20 Sept 2023
6 Jul 2023
19 Jul 2023
6 Jul 2023
15 Jul 2023
6 Jul 2023
Amount
Providing Diesel Generator set
OD175611/2022-2023:Supply, conveyance, loading and unloading, Installation, testing & commissioning of 15 KVA Diesel Generator set with integral acoustic enclosure as per latest CPCB norms with standard accessories as per technical details given below. 1. Engine : a) Make of Engine - as in make of materials b) Type of Engine - BS VI Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - coolant cooled with radiator. e) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Fuel filter g) Lubricating oil filter h) Exhaust silencer i) Exhaust Muffler 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water/coolant temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high coolant/ water temperature. 5. Brushless Alternator a) Make -as in make of materials b) Type - Self exited and self regulated. c) System of Voltage - 3 phase, 440 V, d) Frequency - 50 Hz e) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 6. Fuel Tank- Suitable size built in type integrated with the acoustic enclosure. Fuel connection shall be done as per standards 7. Battery - Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. ,Solid state phase indication lamp for supply ON/OFF with HRC protection. standard control panel with 32A 4P,10KA,MCB as per Kerala Electrical Inspectorate requirements and accessories such as Multi function meter and separate Energy meter etc. complete. The DG set shall have a warrantee period of 3 years from date of commissioning. 8) Initial inspection and testing shall be carried out at factory/manufactures premises/site in presence of departmental representative. The successful tenderer shall give a notice of minimum two weeks for carrying out such test. The successful tenderer shall arrange staff and fuel for test run at his cost.
OD30521/2022-2023:Supply and providing Extension of Exhaust pipe up to the roof top with 50mm MS pipe with bends, flanges etc. including painting etc. with standard accessories as per the direction of department staff at site (fire approved rate)
OD36655/2023-2024:Supply ,installation, testing and commissioning of AMF panel suitable for getting approval from Electrical inspectorate for 15KVA DG set ( make : Kirloskar/KE/LS/Stamford / Crompton / standard make )
OD177491/2022-2023:Charges for conducting load test of 15KVA DG set at standardized factory bed /at site as per standard norms and conditions , in various steps load upto full load for 3 hrs and 10% overload for 20minutes and the rate includes hire and rent of test bed equipment , labour charges, loading and unloading , fuel etc . The test certificate should be given to the client in standard format.
OD177492/2022-2023:Supply and providing Automatic Battery charger suitable for 15KVA DG Battery, having . Full protection against battery overcharging & reverse polarity. Over voltage, overload & short circuit protection, reverse battery protection
OD28132/2022-2023:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required. (excluding cost of HRC fuse links in case of SDF/ SDFCO). 32A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
90.12.1.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.2.2:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)2 core 6 sq mm
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD177066/2022-2023:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for cables 4 sq - 16 sq mm with 20 mm wide x 1.20 mm thick clip as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD30546/2022-2023:Supply and providing 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
OD30547/2022-2023:Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
OD35240/2023-2024:Charges for preparation of drawings first copy A3
OD35241/2023-2024:Copying charges of Electrical/fire Drawing per A3 sheet additional copies
OD177089/2022-2023:Supply and filling HSD in the DG tank
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
OD34036/2023-2024:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required- 2.50 cm, 4 cm
OD34038/2023-2024:Supply and providing Danger 415 V, 125 x 75 mm aluminium anodised legend plates in the existing panel board as required
OD34047/2023-2024:Supply and providing 2mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
OD34391/2023-2024:Supply and installation of ABC type fire extinguisher of 4/5 kg. Capacity complete with initial charges and installation brackets confirming to IS 15683 with ISI mark
OD35214/2023-2024:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Civil work for basement of DG
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
13.41.1:Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work ( Two or more coats) over and including priming coat with water thinnable cement primer
Bidder Name
Angel electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_866670.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .