Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60,153.84Accepted-AOC | ₹60,153.84 | L1 | Accepted-AOC L1 |
| 2 | L2₹60,195.79Rejected-AOC NALLOOR H NALUKODY P O CHANGANCHERRY | ₹60,195.79 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Xavier Joseph L2 | RAJEESH KUMAR R L1 |
|---|---|---|---|---|---|
| 1.00Part 1-Electrification | |||||
| 1.00 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | 18 | metre | 184 ₹3,312 | 183.35 ₹3,300.30 |
| 1.00 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp | 32 | metre | 217 ₹6,944 | 216.78 ₹6,936.96 |
| 1.00 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.2 X 6 sq. mm (19mm) | 4 | set | 276 ₹1,104 | 275.85 ₹1,103.40 |
| 1.00 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size | 18 | metre | 144 ₹2,592 | 144.16 ₹2,594.88 |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 2 | cum | 456 ₹912 | 455.06 ₹910.12 |
| 1.01 | OD287178/2025-2026:Charges for dismandling the existing interlock block/tiles etc for laying cables/pipes etc as
directed at site without damages including plastering holes, redoing interlock block/tiles | 8 | 1 sqm | 233 ₹1,864 | 232.91 ₹1,863.28 |
| 1.01 | OD287179/2025-2026:Supply and fabrication conveyance and installation of angle iron frame work as in position for supporting pipe,switch boards,panel boards etc | 8 | kg | 177.2 ₹1,417.60 | 177.14 ₹1,417.12 |
| 1.01 | OD287180/2025-2026:Supply and installation of dust and Vermin proof wall mounting meter box (450x375x200mm )SINTEX make(GSMB-4537) with base plate suitable to fix single phase energy meter and HRC fuse units and neutral link on wall using suitable nut bolt etc. | 1 | each | 3,609 ₹3,609 | 3,608.78 ₹3,608.78 |
| 1.01 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door | 1 | each | 2,540.2 ₹2,540.20 | 2,540.11 ₹2,540.11 |
Tender Value
₹60,154
EMD Value
₹1,504
Closing Date
24 Oct 2025, 2:00 pmClosed
Jishi R Assistant Engineer
Oof the Assistant Executive Engineer LIDEW Sub division Chavara Block Panchayat
Annual Plan-Chavara BP -Extension Work of Open air Auditorium in Nadakkavu Market of Thekkumbhagam GP -Electrification-General Electrical Work
2025_LSGD_810602_2
07AECVRA 2025-2026
Open Tender
Electrical Works
90 days
Chavara Block Panchayath
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹1,504
Yes
23 Jun 2026
16 Oct 2025
25 Oct 2025
16 Oct 2025
24 Oct 2025
16 Oct 2025
Amount
Part 1-Electrification
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD287178/2025-2026:Charges for dismandling the existing interlock block/tiles etc for laying cables/pipes etc as directed at site without damages including plastering holes, redoing interlock block/tiles
OD287179/2025-2026:Supply and fabrication conveyance and installation of angle iron frame work as in position for supporting pipe,switch boards,panel boards etc
OD287180/2025-2026:Supply and installation of dust and Vermin proof wall mounting meter box (450x375x200mm )SINTEX make(GSMB-4537) with base plate suitable to fix single phase energy meter and HRC fuse units and neutral link on wall using suitable nut bolt etc.
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
OD288587/2025-2026:Supplying and fixing DP sheet steel enclosure on surface/ recess suitable to fix 2 pole isolator/DP MCB as required.
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
OD287184/2025-2026:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD287193/2025-2026:Supply and fixing 63 Amp 4 pole on load Change over switch including enclosure and handle making connections, etc. as required.(L&T/GEM/Hawells or equivalant make)
OD287195/2025-2026:Supply and providing Surface mounted square type 1x1 feet LED ceiling fitting 18 watts or nearest crompton/ philips/Hawells or equivalant make including on surface of wall and giving existing connection
OD287197/2025-2026:Supply and providing 25x6 mm brass nut and bolt with washers in position including drilling holes
OD312300/2025-2026:Charges for preparation of KSEB service connection documents for availing single phase service connection and producing to the consumer including test report drawing etc.
Xavier Joseph (BID ID -2407620)
Bidder Name
Xavier Joseph
RAJEESH KUMAR R
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1353193.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.25 MB
BOQ_1353193.xls
BOQ • 0.32 MB
panad.pdf
Tender Documents • 0.25 MB
sbdnad.pdf
Tender Documents • 1.93 MB
fonad.pdf
Tender Documents • 0.25 MB
affnad.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid