| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L1 | Accepted-AOC CA NO. GE (AF) / TVM / 03 OF 2020 - 2021 | |
| 2 | L2₹25.8 L+₹2,220 (0.09%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹26.0 L+₹18,730 (0.73%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹26.5 L+₹76,614 (2.97%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹27.9 L+₹2.1 L (8.19%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
3 Jun 2020, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPLACEMENT OF REFRIGERATORS AND WATER COOLER ACS AND REPLACEMENT OF COOLING APPLIANCES AGAINST BER ITEMS UNDER GE AF TRIVANDRUM
2020_MES_338188_1
GE AF TVM/ 8222
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF Trivandrum
₹64,000
Yes
8 Jul 2020
9 Apr 2020
5 Jun 2020
9 Apr 2020
3 Jun 2020
23 Apr 2020
Amount
M & L for submain wiring with PVC insulated unsheathed 1100 volts graded multi stranded copper conductor FRLS cable two runs of 4 sqmm drawn through in and including suitable size PVC conduit with all accessories fixed to wall/roof/ceiling/floors along with one run of 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100volt grade for earth continuity conductor and connected to common earth and drawn through and including medium grade rigid PVC conduit of 25 mm dia includung accessories such as bends, supports etc complete all as specified and directed by Engineer-in-Charge Note: Two runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor and PVC conduit shall be measured as unit length.
Supply and fix refrigerator, electric driven, single phase 230 volts, 50 HZ AC, double door, frost free, anti-bacteria filters etc of capacity 310-350 Ltr, BEE 4/5 Star rated complete all as specified and directed by Engineer-in-Charge. Make LG/Whirlpool/ SAMSUNG
Supply and installation, commissioning of water cooler stainless steel body with electronic water purification system with UV technology, electric driven single phase having storage and nominal cooling capacity of 80/40 Ltrs with flow rate 200 ltrs/Hr (heavy duty high flow) complete all as specified and directed by Engineer-in-ChargeMake: Cross Field Water Purifier/Voltas/Blue Star
Supply and lay 3-layer PP-R (poly propylene random copolymer) pipes of 20mm dia, SDR 7.4 & SDR 11, UV stablised and antimicrobial welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors/roofs etc complete all as specified and directed by Engineer-in-Charge.
Supply and lay 3-layer PP-R (poly propylene random copolymer) pipes of 25mm dia, SDR 7.4 & SDR 11, UV stablised and antimicrobial welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors/roofs etc complete all as specified and directed by Engineer-in-Charge.
S & F in fix PVC connection for jointing the pipe to water cooler pipe of 20mm bore complete all as specified and directed
Supply and install testing, commissioning of split ACs with inverter type comprising of indoor/outdoor with copper coil single phase 230V, 50Hz complete with cordless remote control unit of high EER rated BLDC compresor, including necessary fixing arrangement complete unit shall be placed at suitable position and height inside the room and outdoor unit at suitable place outside the room on plinth height / on wall or roof as suitable and including metallic bracket with fixing bolts for outdoor unit, insulated copper piping at required length at site, Refrigerant R410-A of cpapcity 1.5TR (copper type) 5 star rated complete all as specified and directed by Engineer-in-Charge. Make : VOLTAS Model No 185 V SZS(R 32) , Blue Star Model No IC 518 DATU, and Hitachi Model No Kashikoi 5300 X ( RSOG518ICEA)
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.00 KVA complete all as specified and directed by Engineer-in-Charge. Make V-Guard VWI400/Monitor/Microtek.
General Engineering and Constructions
LAKSHMI ELECTRICAL ENTERPRISES
JEETH CONSTRUCTION
ROTECH ENGINEERS AND BUILDERS
SUPER COOL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .