Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.6 CrAccepted-AOC | ₹77.6 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹70.6 Cr
EMD Value
₹5 L
Closing Date
3 Oct 2023, 12:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Public Health Circle, Kottayam, Kerala Water Authority
Koottickal Panchayath- (1)Supply _ laying of transmission mains (2) Construction of service reservoirs_(3)Distribution networks in the Koottickal panchayath and providing FHTCs.
2023_KWA_601137_1
1RE_No.WRD/KWA-CE(SR)/TR /7902/2022_26_8_7/1
Open Tender
Civil Works - Water Works
365 days
Koottickal
Please refer Tender documents.
8 documents required · 8 mandatory
₹16,540
₹5 L
O/o the SE, PHC, KWA Kottayam
25 Jan 2024
14 Sept 2023
4 Oct 2023
14 Sept 2023
3 Oct 2023
14 Sept 2023
14 Sept 2023 - 16 Sept 2023
16 Sept 2023
Amount
Pumping lines,transmission lines, Distribution networks in the Koottickal avu Panchayath for the 4156 nos of FHTCs
100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.
100.98.116:Supply of DI K9 Pipe Conforming to IS 8329/2000, 150mm Dia.
100.98.115:Supply of DI K9 Pipe Conforming to IS 8329/2000, 100mm Dia.
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
18.73.2:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :150 mm dia Ductile Iron Double Flanged
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
100.98.224:Supply of PVC Pipe, 8kg/cm2, 110mm Dia.
OD90079/2023-2024:Supply of PVC pipe, 12.5kg/cm2, 110mmDia
100.98.225:Supply of PVC Pipe, 8kg/cm2, 140mm Dia.
100.98.226:Supply of PVC Pipe, 8kg/cm2, 160mm Dia.
100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia.
100.98.238:Supply PVC Pipe, 10kg/cm2, 140mm Dia.
OD249901/2022-2023:Supply of PVC pipe, 12.5kg/cm2, 90mmDia
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
OD90071/2023-2024:GI pipe medium 125 mm Dia
OD90072/2023-2024:100 mm GI Pipe
OD90073/2023-2024:Supplying 80 mm GI (M) pipes.-medium
OD249907/2022-2023:cost of GI-Specials..such as Bends ,Tee,coupling ,End caps,CID/CIR etc.
OD249908/2022-2023:cost of PVC special (Bends , Tee, coupler, Tailpiece, End caps,CID/CIR etc)
100.98.445:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 40mm.
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.
100.98.450:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.459:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 125mm.
100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.
100.98.485:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 200mm.
Working Charges
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.59:Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
16.91.1:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
OD98015/2023-2024: DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete.
OD90136/2023-2024: Design of structural drawings for the sump cum pumping stations - 3 nos( Njarkadu,Kodunga temple,Paramada wagamon road ), SCADA control station at Njarkadu, GLSRs(6 nos) ,BP tanks , Steel tanks ,any other storing reservoirs/pumping stations in the Kootickal GP after conducting the soil tests in the required above locations, Anchor block drawings, pipe line support drawings, pipe line bridge design drawings ,etc verification, submition of the design drawings, approval of the design drawings from WASCON, & vetting from WASCON-KWA
OD90138/2023-2024:Excavating in hard rock by chemical blasting in populated area using jack hammer for boring holes,cleaning the rock surface,filling chemical(Expanasive chemical mortar),providing protection sheet at top surface, and to be excavated the brocken/split hard rock on next day with hydraulic excavator stacking serviceble material for use,including cost of chemicals,labour charges,hire for tools and plants,machinery, etc complete as per the direction of dept officers
Laying CI /DI / pipes
100.14.1:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 100mm diameter Ductile Iron Class K-9 Pipes.
100.14.2:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 150mm diameter Ductile Iron Class K-9 Pipes.
100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.
18.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
100.35.2: Testing 150mm DI/CI pipeline with potable water to the required test pressure 150 mm dia Observed Data derived from item no.1018 of PHED DATA
100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA
OD256703/2022-2023:Labour for cutting DI pipe with steel saw. 100 mm diameter D.I. pipe
OD249891/2022-2023:Labour for cutting DI pipe with steel saw .200 mm DI pipe
OD249892/2022-2023:Labour for Cutting 150 mm DI pipe with steel saw
100.35.1:Testing 100mm DI/CI pipeline with potable water to the required test pressure 100 mm dia
Laying PVC Pipes & Specials
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.9.10:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 140 mm nominal outside diameter pipes.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
Laying G.I Pipes & Specials
100.12.8:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
100.12.10:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 125mm diameter nominal bore.
Fitting Air valves ,PRVs, flow meters and Sluice Valves
100.32.2:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 40mm Single Acting Air Valve.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.
100.31.1.3:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 125mm diameter, Class I.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
OD249895/2022-2023:Supplying & fixing 150mm Dia. Mechanical Flow Meter of Woltman type conforming to ISO 4064 Class B of ARAD/ZENNER/REYCHEM RPG/ITRON make and shall be tested and certified by FCRI Palackadu, and fitting in proper position and alignment as per the manufacturers' instruction. (As per Circular noKWA/HO/SP-4014/2012/Flow meters & Soft Starter dated 5/9/2012)
OD249896/2022-2023:Supplying and Fixing in position pressure gauge, in read up to 35kg/cm2 marked in MKS system including cost of 300/250/200/150/125/100mm X 20mm MS saddle piece ,1.5m 20mm GIM pipe ,1 no GM ball valve and Pressure gauge and all labour charges etc complete
OD249897/2022-2023: Supplying and fixing 200mm Dia. Mechanical Flow Meter of Woltman type conforming to ISO 4064 Class B
OD90092/2023-2024:Supplying & fixing 100mm Dia. Mechanical Flow Meter of Woltman type conforming to ISO 4064 Class B of ARAD/ZENNER/REYCHEM RPG/ITRON make and shall be tested and certified by FCRI Palackadu, and fitting in proper position and alignment as per the manufacturers' instruction. (As per Circular no KWA/HO/SP-4014/2012/Flow meters & Soft Starter dated 5/9/2012)
OD90093/2023-2024:Supplying and fixing 100/80 mm Dia.Electro Magnetic Flow tranmitter including specials conforming to ISO 4064 Class B ,integration with the SCADA system for the measurement of flow & other parameters and shall be tested and certified by FCRI Palakkadu, and<br>fitting in proper position and alignment as per the manufacturers' instruction including all labour & material charges.
OD90094/2023-2024:Supplying and fixing 200mm Dia.Electro Magnetic Flow tranmitter including specials conforming to ISO 4064 Class B ,integration with the SCADA system for the measurement of flow & other parameters and shall be tested and certified by FCRI Palakkadu, and<br>fitting in proper position and alignment as per the manufacturers' instruction including all labour & material charges.
OD90095/2023-2024:Providing and fixing 200mm Pressure reduce valve PN 25,Max out 0.5kg-7kg as per the direction from the departmental engineers
OD90096/2023-2024:Providing and fixing 150mm Pressure reduce valve PN 25,Max out 0.5kg-7kg as per the direction from the departmental engineers
OD90097/2023-2024:Providing and fixing 80 mm Pressure reduce valve PN 25,Max out 0.5kg-7kg as per the direction from the departmental engineers
OD90098/2023-2024:Providing and fixing 100mm Pressure reduce valve PN 25,Max out 0.5kg-7kg as per the direction from the departmental engineers
Valve Chamber and Anchoring Works
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD249909/2022-2023:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
ROAD RESTORATION in PWD roads
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.2.A.2:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-IV - For lower sub-base - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.10.2.a:Providing and laying of premix sand seal coat with HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping 6.7 mm size and bitumen (VG-30) 6.8 kg per 10 sqm
5.2.b:Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.
5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)
5.7.1:Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.09 mm (Type-A) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade, and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to the required level and grade.
12.8.A:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications<br> PCC Grade M15 ( Without formwork) <br>
8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.
8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)
8.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3<br> Road Markers/Road Stud with Lense Reflector :-
Road restoration panchayath roads
3.6:Excavation in Marshy Soil Excavation for roadway in marshy soil with hydraulic excavator 0.9 cum bucket capacity including cutting and loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 m, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.6.
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)
75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)
Construction of 0.5 LL GLSRs at Plappalli top, 6 Acre,NSS Karayogam Chathanplappalli,Mundapally,Elankadu,Moopanmala road,Mlakkara,Bhadrakali temple wagamon road,(steel tank - 8 nos)
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD79511/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD90043/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
OD79123/2023-2024:Supply and fixing of stainless steel spring loaded pressure relief valve as per IS 9739(1981)
OD90103/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 50000 L, thickness of 0.6 mm, in multiple layers, required height and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hot-dip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be of 4.3m. DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve. TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
2.36:Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
OD90047/2023-2024:Providing solar panel with storage battery(8Hrs back Up) to light two members to watt LED lamp,including cost of shade fabricated stand post etc.
OD90048/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90049/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
Construction of 0.3 LL GLSR at Plapalli temple, Adivaram top, (steel tank - 2 nos)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
OD79179/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
OD79174/2023-2024:Supply and fixing of stainless steel spring loaded pressure relief valve as per IS 9739(1981)
OD90104/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 30000 L, thickness of 0.6 mm, in multiple layers, required capacity and height and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hot-dip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be 2.90 m. DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve.TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
OD90044/2023-2024:Hrs back up)to light two members to 40watt LED lamp, including cost of shade fabricated stand post etc.
OD90045/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90046/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
OD91606/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
Construction of 4 LL GLSR at Kootickal mathumala area
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
OD69320/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity),Supply and laying 25x3mm required length of GI strip through epoxy resign cast support,Down conductor through wall vertical run/through parapet,Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet,Supply and laying of 32x6mm GI strip through ground including earth work excavation back filling and jointing etc complete and providing 2 Nos of pipe earthi
OD69321/2023-2024:Providing water level indicator assemblying by using float, pully, nylon rope, plumpbob with indiactor lamp, MS board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level , painting 10cm divisions, lettering including cost for clamps, drilling of RCC slabs etc. complete.
OD69322/2023-2024:Providing Solar panel with storage battery to light two members to watt CFL lamp, including cost of shade fabricated stand post etc.
OD69323/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
18.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
18.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
OD69350/2023-2024:Labour for Cutting 150 mm DI pipe with steel saw
18.72.16:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:150 mm dia Ductile Iron Class K - 9 Pipes
18.73.2:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :150 mm dia Ductile Iron Double Flanged
OD91608/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
OD91609/2023-2024:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2 m long (1m in rock and 1 m in concrete) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout(0.10kg/each) etc complete
Construction of 2 LL GLSR at Kaavali church, Kaavali and Yendayar
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
OD91610/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
OD91611/2023-2024:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2 m long (1m in rock and 1 m in concrete) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout(0.10kg/each) etc complete
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.71:Lettering with black Japan pint of approved brand and manufacture
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
18.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
18.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
18.72.2:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:150 mm dia Ductile Iron Class K-7 pipes
18.73.2:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :150 mm dia Ductile Iron Double Flanged
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
OD68639/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity),Supply and laying 25x3mm required length of GI strip through epoxy resign cast support,Down conductor through wall vertical run/through parapet,Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet,Supply and laying of 32x6mm GI strip through ground including earth work excavation back filling and jointing etc complete and providing 2 Nos of pipe earthi
OD68640/2023-2024:Providing water level indicator assemblying by using float, pully, nylon rope, plumpbob with indiactor lamp, MS board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level , painting 10cm divisions, lettering including cost for clamps, drilling of RCC slabs etc. complete.
OD68641/2023-2024:Providing lightning arrestors with ISI specification etc. complete
OD68642/2023-2024:Providing Solar panel with storage battery to light two members to watt CFL lamp, including cost of shade fabricated stand post etc.
OD68643/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
Construction of 1.5 LL GLSR at Mathumala And at yendayar Mundaplappalli road @ level 308
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
OD91613/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD91614/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
OD67942/2023-2024:Providing water level indicator assemblying by using float, pully, nylon rope, plumpbob with indiactor lamp, MS board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level , painting 10cm divisions, lettering including cost for clamps, drilling of RCC slabs etc. complete.
OD67943/2023-2024:Providing lightning arrestors with ISI specification etc. complete
OD67944/2023-2024:Providing solar panel with storage battery to light two members to watt CFL lamp,including cost of shade fabricated stand post etc.
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.72.17:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:200m dia Ductile Iron Class K - 9 pipes
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
OD68553/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
PLC- SCADA Automation works
OD90124/2023-2024:Installation, Cabling, Termination and Commissioning Charges for the service reservoirs in Kootickal GP - including all labour and material charges as directed by the Engineer in charge of the work(make std ) .
OD90125/2023-2024:Kootickal- IOT Module for SCADA integration 24V GSM Support- for the GLSR,OHSR in the Kootickal GP including all labour & material charges as directed by the department officers (Delta/L&T)
OD90126/2023-2024:Installation, Cabling, Termination and Commissioning Charges for the control stations & Boosting stations,pump houses in Kootickal GP - including all labour and material charges as directed by the Engineer in charge of the work(make Delta/L&T) .
OD90127/2023-2024:SCADA Control Station with license, PC , UPS ands Printer, 1000Tag minimum at Njarkadu for the Kootickal Grama Panchayath office including all labour & material charges as directed by the Engineer in charge of the work (make Delta/L&T)
OD90128/2023-2024:Main PLC Control Panel at Njarkadu for Kootickal GP(for all the pumps, pump houses ,GLSR/OHSR ) including all labour & material charges as directed by the Engineer in charge of the work(make Delta/L&T)
OD90129/2023-2024:Control Panel for Boosting Station Pumping, SCADA Control and OFC Integration with GSM Communication for the small pumping stations , Boosting stations,GLSR,OHSRs in the Kootickal GP including all labour and material charges as directed by the Engineer in charge of the work(make Delta/L&T)
OD90130/2023-2024:Pressure Transmitter for pumping line ( 4-20mA), 24VDC for the pumping stations ,Boosting stations in the Kootickal GP including all labour and material charges as directed by the Engineer in charge of the work (make Delta/L&T)
OD90131/2023-2024:Ultrasonic Level Transmitter ( well level) with GSM Communication for the pumping stations ,Boosting stations in the Kootickal GP including all labour and material charges as directed by the Engineer in charge of the work (SBEM/Nivelco)
OD90132/2023-2024:SCADA controls & operations -PLC control system - Supply and Installation of Automation at Boosting Stations & pumping stations in the Kootickal GP - Supply and installation of junction pit, PE100 PN10 50mm HDPE Pipe and single mode OFC min24 core armoured type (Finolex/Sterlite make) as directed by the department officers.
OD90133/2023-2024:Kootickal GP-Ultrasonic Level Transmitter ( well level) , Battery Operated with GSM Communication including all labour and material charges as directed by the Engineer in charge of the work
OD90134/2023-2024:Kootickal- IOT Transmitter Unit Battery Operated with GSM Communication- for the GLSR,OHSR in the Kootickal GP including all labour & material charges as directed by the department officers
OD90135/2023-2024: Kootickal - Installation, Cabling, Termination and Commissioning Charges for the service reservoirs in the Kootickal Grama Panchayath as per the direction from the departmental engineers
OD90139/2023-2024:Supply & fixing of 150MM Butterfly Valve with Motorized Actuator - ON/OFF Type - Auxiliary Supply 230V AC including all labour & materila charges, integration with SCADA, supply of cables for the actuator, development charges, cabling charges etc including all works of automation & as per the direction of the departmental officers.
OD90140/2023-2024:Supply & fixing of 100MM Butterfly Valve with Motorized Actuator - ON/OFF Type - Auxiliary Supply 230V AC including all labour & materila charges, integration with SCADA, supply of cables for the actuator, development charges, cabling charges etc including all works of automation & as per the direction of the departmental officers.
Construction of 1.5 LL sump cum boosting station at Wagamaon road (Paramada)
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD69281/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
OD69326/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
OD91627/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD69327/2023-2024:Providing water level indicator assemblying by using float, pully, nylon rope, plumpbob with indiactor lamp, MS board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level , painting 10cm divisions, lettering including cost for clamps, drilling of RCC slabs etc. complete.
OD69328/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity),Supply and laying 25x3mm required length of GI strip through epoxy resign cast support,Down conductor through wall vertical run/through parapet,Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet,Supply and laying of 32x6mm GI strip through ground including earth work excavation back filling and jointing etc complete and providing 2 Nos of pipe earthi
OD90034/2023-2024:Providing solar panel with storage battery to light two members to watt CFL lamp,including cost of shade fabricated stand post etc.
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
18.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
Construction of 3 LL sump cum boosting station at Kodunga temple
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
OD90026/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.35:Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
OD91628/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
OD78456/2023-2024:Providing water level indicator assemblying by using float, pully, nylon rope, plumpbob with indiactor lamp, MS board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level , painting 10cm divisions, lettering including cost for clamps, drilling of RCC slabs etc. complete.
OD78457/2023-2024:Providing lightning arrestors with ISI specification etc. complete
OD78458/2023-2024:Providing Solar panel with storage battery to light two members to watt CFL lamp, including cost of shade fabricated stand post etc.
OD78459/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.72.17:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:200m dia Ductile Iron Class K - 9 pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Construction of 2.5 LL Sump cum boosting station & SCADA control station at Elankadu (Njarcadu)
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
OD91604/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD91605/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.71:Lettering with black Japan pint of approved brand and manufacture
OD78141/2023-2024:Providing solar panel with storage battery to light two members to watt CFL lamp,including cost of shade fabricated stand post etc.
OD78142/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD78143/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
OD78144/2023-2024:Supplying and fixing C.I with cover and frame for manholes:<br>560 mm diameter ( heavy duty) the weight to be not less than 208 kg
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
18.72.15:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.72.17:Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:200m dia Ductile Iron Class K - 9 pipes
18.73.1:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :100 mm dia Ductile Iron Double Flanged
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged
OD90015/2023-2024:Providing and fixing aluminium work for doors, (2.4mx2.1m) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and Providing and fixing glazing in aluminium door, with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge.
OD90016/2023-2024:Supply and installation of 2 ton inverter type split air conditioner ( 5 star) with stabilizer and other connected items .
OD90017/2023-2024:Supply and providing water supply and sanitary arrangements, ,office furniture (table - 3 nos,chairs- 6 nos,computer table- 3 nos,steel alamarah- 2 nos,steel racks- 3 nos,etc )for the SCADA room
9.46.2:Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete:20 mm dia
9.47.1:Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets:20 mm dia (heavy type)
9.76:Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
OD90018/2023-2024:Electrification in SCADA room - Supplying and drawing 2 x 1.5 sq.,3 x 1.5,4 x1.5 mm, 2 x 2.5 sq.,3 x 2.5,4 x 2.5 mm for light point fan, point,water heater,AC ,etc...PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required,Supplying and drawing 3x 1.5 sq. mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Supplying and fixing 1 or 2 Module on the existing modular plate & switch box including connections but excluding modular plate etc.Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc.,Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc,Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.,Supply and drawing bare earthing conductors of 4.00 mm copper conductor (8 SWG) along with wiring/ cables and giving connection as required.Charges for cutting holes suitable for accommodating exhaust fans of size 305 mm including plastering, colour washing etc. as required. Makes of ceiling fan - Almonard/Crompton Greaves/ Khaithan,Supply of 1200 mm sweep - 5 star rated ceiling fan(6nos) with standard accessories like down rods etc.and Ex-host fan - Almonard/ Crompton Greaves/ Khaithan,Supply of minimum dia 300 mm sweep - 5 star rated with standard accessories like down rods etc. as required.Wall fan( 2nos) 600 mm Almonard/ Crompton Greaves/ Khaithan Supplying and fixing brass batten/ angle holder with shade including connection etc.Supply of surface mounted/ suspended LED linear lights(10nos) with fitting with high efficiency and with lumen output of 4000Lm and a color temperature of 6500 k. The efficacy of the fitting shall net be less than 105 Lm/W. The driver shall be electronic inbuilt type.Make: Phlips BN108C LED 40S PSU CDL WH or equivalent.Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Etc as per the direction of deparmental Engineers. (75mm X 75mm) GI box along with modular base & cover plate for modular switches in recess etc.Supplying and fixing 3 Module (100mm X 75mm) GI box along with modular base & cover plate for modular switches in recess etc. as required.Supplying and fixing 5/6 amps switch on the existing modular plate & switch box including connections but excluding modular plate etc.. Supplying and fixing 15/16 amp switch on the existing modular plate & switch box including connections but excluding modular plate etc.... Supplying and fixing 3 pin 5/6 amp socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc,Supplying and fixing 6 pin 15/16 amp socket outlet-All electrification works in the strutchers .
13.26:Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
10.17:Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.10:Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete.
21.13:Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.41.4:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm
17.32.2:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
17.71:Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
17.73.2:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms
9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
Construction of 1 LL GLSR at 10 Acre area - Steel tank
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD79412/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD79494/2023-2024:Supply and fixing of stainless steel spring loaded pressure relief valve as per IS 9739(1981)
OD90105/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 100000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be of 5.7m.DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve.TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
OD90051/2023-2024:Providing solar panel with storage battery 98hrs back up)to light two members to 40 watt CFL lamp,including cost of shade fabricated stand post etc.
OD90052/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90053/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
Construction of 0.25 LL GLSR at 100 Acre road,Cheruka road (Steel tank- 2 nos)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD79914/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
OD90106/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 25000 L thichness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be of 2.20m .DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve.TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components
OD79908/2023-2024:Supply and fixing of stainless steel spring loaded pressure relief valve as per IS 9739(1981)
OD90056/2023-2024:Providing solar panel with storage battery (8Hrs back up)to light two members to 40 watt LED lamp, including cost of shade fabricated stand post etc.
OD90057/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90058/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
OD91710/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
Providing 4156 nos of FHTCs
100.60.1.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.1.4.2: Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.2.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
100.60.10.4.1:Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
100.60.12.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
OD256707/2022-2023:Providing & fixing the stand post using 90mm PVC, Cement concrete for the plat form) ,Plastering the plat form for the FHTCs including all labour & material charges
Construction of 0.1 LL GLSR at in front of the Mundapally top road,Madapalli area BP tanks adivaram( 2 nos) , - Steel tank- 4 nos
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
OD80688/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
OD90107/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 10000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be of 5.7m.DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve.TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
OD80684/2023-2024:Supply and fixing of stainless steel spring loaded pressure relief valve as per IS 9739(1981)
OD90060/2023-2024:Providing solar panel with storage battery(8hrs back up) to light two members to watt LED lamp,including cost of shade fabricated stand post etc.
OD90061/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90062/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
OD91730/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
Construction of the toilets in Kootickal Mathumala,sump cum boosting station at Elankadu, Yendayar - 3 nos
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
50.18.7.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10 Kgf/cm2- Internal work- exposed on wall
50.18.8.1.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2
50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.7.11:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI - 304 (18/8) Wash basin 530 x 345 mm with single 15mm C.P. brass pillar tap
17.28.2.1:Flexible pipe32 mm dia
17.60.1.1:Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outletSand cast iron S & S as per IS : 3989
18.57.1:Providing and fixing PTMT, push cock of approved quality and colour.15 mm nominal bore, 98 mm long, weighing not less than 75 gms
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
9.117.2:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 42x50 mm
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
OD81760/2023-2024:Supply and erection of concrete Septic tank
OD91731/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD91732/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Construction of 1.5 LL capacity steel tank at Chathanplappalli top & Parathanam
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD90063/2023-2024:DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
OD90064/2023-2024: Supplying & providing MS dowel bars of size 12mm dia of 1m long (.5 on between rubble & .5m in Concrete) including drilling holes for an average depth of .5 m for providing dowel bars and fixing in position using cement grout etc complete as director by deptl. officers for the Anchor blocks on the MS/DI/GI pipes.
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
OD90066/2023-2024:Providing solar panel with storage battery to light two members to watt CFL lamp,including cost of shade fabricated stand post etc.
OD90067/2023-2024:Supply and providing imported vertical air terminal with 12 needled nickel coated spike receiver,supporting rod and stand including all accessories as required with positive receiver(45 m receiving capacity).Supply and laying 25x3mm required length of GI strip through epoxy resin cast support.Down conductor through wall vertical run/through parapet.Supply and installation of test joint box fabricated out of 16 SWG CRCA sheet.Supply and laying of 32x6mm GI strip through ground including earthwork excavation back filling and joining etc complete and providing 2 nos of pipe.
OD90068/2023-2024:Providing water level indicator assembling by using float, pulley, nylon rope, plump bob with indicator. M S board(30cm width) with sufficient depth to show the zero water level and full depth to show the zero water level and full water level,painting 10cm divisions,lettering including cost for clamps,drilling of RCC Slabs etc. complete
OD90108/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 150000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiple-layered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness.Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The height of the Tank shall be of 5.7m.DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design inlet,outlet,overflow and scour valves should be provided. ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. iii) One (1) scour drain outlet from the floor of the tank with isolation valve.TANK LINERS:Tank liners shall be purpose-designed and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one- piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&#39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre withfood grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
MS fabrication works
OD90080/2023-2024:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90081/2023-2024:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90082/2023-2024:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90083/2023-2024:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
OD90084/2023-2024:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90085/2023-2024:Welding 150mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90086/2023-2024:Cutting 150mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90087/2023-2024:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 10 mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
OD90088/2023-2024:Grinding cut and weld edges of 100mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90089/2023-2024:Welding 100mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90090/2023-2024:Cutting 100mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
OD90091/2023-2024:In situ fabrication of M.S. pipes of size 100mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.5.2:Fabricating M.S. flanges of diameter 100mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
Providing FHTcs
100.60.1.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.1.4.2: Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.2.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers
100.60.10.4.1:Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
100.60.12.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
OD90102/2023-2024:Providing & fixing the stand post using 90mm PVC, cement concrete for the plat form) ,Plastering the plat form for the FHTCs including all labour & material charges
Pumps and motors
OD90121/2023-2024:Submitting application to KSEBLfor power connection and power extension including preparation of drawing obtaining approval for drawings arranging inspection and obtaining ,power connection(necessary statutory fee will be paid by KWA)
Bidder Name
SIAN INFRA AND REALCON LLP
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid