GEMC-511687706982575
Awarded to SPI ENGINEERS PVT LTD
₹53,899
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| TRUE-RMS INDUSTRIAL LOGGING MULTIMETER WITH TRENDCAPTURE | Fluke 289 | - | 1 NOS | ₹53,899 | 53,899 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹53,899Qualified Make: FLUKE
Model: Fluke 289 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: Fluke 289 | L1 | Qualified | |
| 2 | L3₹56,700+₹2,801 (5.20%)Qualified Make: FLUKE
Model: Fluke 289 E 20 SHAM NAGAR TILAK NAGAR SHAM NAGAR WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | Make: FLUKE
Model: Fluke 289 | L3 | Qualified | |
| 3 | Qualified Make: FLUKE
Model: Fluke 289 | Make: FLUKE
Model: Fluke 289 | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Aug 2018, 10:00 amClosed
digital multimeter ( PAC Only ) Digital Multimeter ( 1 ) ( Under PAC ) Make fluke Model fluke289 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 4.5 3.5
4.5
6.5 Measurement Type True RMS Average
True RMS Counts 50000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 0.5 0.005
0.05
0.1
0.5
1 DC Voltage resolution 100 0.001
0.01
1
10
100 AC Voltage Range 1000 600
1000 AC Voltage Accuracy 0.5 0.08
1 AC Voltage resolution 100 0.001
100 1/5 DC Current Range 10 3
10 DC Current Accuracy 0.05 0.005
1.5 DC Current resolution 100 0.001
100 AC Current Range 10 3
10 AC Current Accuracy 0.5 0.5
1.5 AC Current resolution 100 0.001
100 Resistance Range 500 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 10 0.001
100 Capacitance Range ( Micro farad ) 1 to 100 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 1.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 100 0.001
NA Frequency Range ( KHz ) 100 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 100 0.001
NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 1 0.001
NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings * Computer Interface along with software Not Available * Dimensions ( mm X mm X mm ) HxWxL 22.2 cm x 10.2 cm x 6 cm * Weight 870.9 * Other Features Multiple on-screen * 2/5 displays Yes True-rms AC bandwidth 100 kHz DBV/dBm Yes DC mV resolution 1 μV Megohm range Up to 500 M Conductance 50.00nS Continuity beeper Yes Battery/Fuse access Battery/Fuse Peak 250 μS Elapse time clock Yes Time of day clock Yes Min-Max-Avg Yes Frequency Yes Duty Cycle 0.01 % to 99.99 % Pulse Width 0.025 ms
0.25 ms
2.5 ms
1250.0 ms Hold Yes Isolated Optical Interface Yes Auto/Touch Hold Yes Reading memory Yes Log to PC Yes Interval/Event Logging Yes Logging Memory Up to 10
000 readings Resistance Low Ohm 0.001 Ω to 50.000 Ω 10 mA source LoZ Yes Low Pass Filter Yes SAFETY Safety Rating Category IV 600 V of IEC 61010 Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL
CE
CSA
TUV * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery Ni-MH * if Non-rechargeable
then size of the battery cell AA * number of non- rechargeable the battery/cell 4 * Voltage of 0 * 3/5 rechargeable Battery capacity of rechargeable battery(milli Ampere Hour) 8 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment Fluke 289 meter
1 set TL71 test leads
1 set AC175 alligator clips
1 set test probe caps
1 set amp jack plugs
6 AA batteries
User manual CD * WARRANTY Warranty 2 1
5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 60 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test SAPL/FLUKE 289
Dt. 19.06.2018 * 4/5 Name and address of the Lab for the specification test FLUKE USA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Suvarna Kumari K 695022
RFF Area
VSSC
Thumba PO 1 15
511309
GEM/2018/B/72554
GeM Contract
digital multimeter
GeM Contract
15 days
Kerala; Thiruvananthapuram
PRODUCT
Awarded to SPI ENGINEERS PVT LTD
₹53,899
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| TRUE-RMS INDUSTRIAL LOGGING MULTIMETER WITH TRENDCAPTURE | Fluke 289 | - | 1 NOS | ₹53,899 | 53,899 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter ( PAC Only ) Digital Multimeter ( 1 ) ( Under PAC ) Make fluke Model fluke289 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 4.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 50000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.5 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 100 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 1000 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.5 0.08 | - | - | - |
| 1 AC Voltage resolution 100 0.001 | - | - | - |
| 100 1/5 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 0.05 0.005 | - | - | - |
| 1.5 DC Current resolution 100 0.001 | - | - | - |
| 100 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 0.5 0.5 | - | - | - |
| 1.5 AC Current resolution 100 0.001 | - | - | - |
| 100 Resistance Range 500 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 10 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) 1 to 100 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 1.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 100 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 100 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 100 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 1 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings * Computer Interface along with software Not Available * Dimensions ( mm X mm X mm ) HxWxL 22.2 cm x 10.2 cm x 6 cm * Weight 870.9 * Other Features Multiple on-screen * 2/5 displays Yes True-rms AC bandwidth 100 kHz DBV/dBm Yes DC mV resolution 1 μV Megohm range Up to 500 M Conductance 50.00nS Continuity beeper Yes Battery/Fuse access Battery/Fuse Peak 250 μS Elapse time clock Yes Time of day clock Yes Min-Max-Avg Yes Frequency Yes Duty Cycle 0.01 % to 99.99 % Pulse Width 0.025 ms | - | - | - |
| 0.25 ms | - | - | - |
| 2.5 ms | - | - | - |
| 1250.0 ms Hold Yes Isolated Optical Interface Yes Auto/Touch Hold Yes Reading memory Yes Log to PC Yes Interval/Event Logging Yes Logging Memory Up to 10 | - | - | - |
| 000 readings Resistance Low Ohm 0.001 Ω to 50.000 Ω 10 mA source LoZ Yes Low Pass Filter Yes SAFETY Safety Rating Category IV 600 V of IEC 61010 Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| TUV * POWER REQUIREMENTS Power Requirements Battery Operated * if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) * if rechargeable | - | - | - |
| then chemistry of the battery Ni-MH * if Non-rechargeable | - | - | - |
| then size of the battery cell AA * number of non- rechargeable the battery/cell 4 * Voltage of 0 * 3/5 rechargeable Battery capacity of rechargeable battery(milli Ampere Hour) 8 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment Fluke 289 meter | - | - | - |
| 1 set TL71 test leads | - | - | - |
| 1 set AC175 alligator clips | - | - | - |
| 1 set test probe caps | - | - | - |
| 1 set amp jack plugs | - | - | - |
| 6 AA batteries | - | - | - |
| User manual CD * WARRANTY Warranty 2 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 60 * Operating Humidity (RH) 90 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test SAPL/FLUKE 289 | - | - | - |
| Dt. 19.06.2018 * 4/5 Name and address of the Lab for the specification test FLUKE USA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Suvarna Kumari K 695022 | - | - | - |
| RFF Area | - | - | - |
| VSSC | - | - | - |
| Thumba PO 1 15 | - | - | - |
Exempted
6 Sept 2018
24 Aug 2018
contract_GEMC-511687706982575.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_511309.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .