Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.9 L+₹1.0 L (6.22%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹18.8 L+₹1.9 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not admitted |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
17 Apr 2020, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIR TO BLDG NO NP-18-20A (OR MESS) AND PROVISION OF WASHING POINT (DHOBI GHAT) NEAR BLDG NO. 4B AT KANCHRAPARA UNDER GE BARRACKPORE
2020_MES_329827_1
8386/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
2 documents required · 2 mandatory
₹500
GE Barrackpore
₹46,600
Yes
30 May 2020
28 Feb 2020
20 Apr 2020
29 Feb 2020
17 Apr 2020
14 Mar 2020
Amount
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.5 sqm but not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Demolition of brick work built in cement mortar etc complete all as specified and directed.
Demolition of un-reinforcement cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Dismantling timber scantlings (framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as directed.
Hacking out old broken glass (any thickness size quality or description) from wooden or steel frame, glazed with putty or fixed with beads etc complete all as specified and as directed.
M&L for second class hard wood in scantling, clean swan as in frame work, fixed with nails complete all as specified and directed.
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
S&F for pressed steel frames for door of size 165mm X 60mm with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F for pressed steel frames for door of size 105mm X 60mm with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F for 35mm thick, factory made plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in brick, concrete wall for fixing of hold fast, coping including necessary form work all as specified and directed.
S&F for aluminium alloy wire cloth, 0.45 mm nominal dia of wire & average width of aperture 1.40mm & fixed with aluminium wire with staple/ or with aluminium beading, fixed to aluminium window complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm normal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete as in repair all as specified and directed.
S&F for anodized aluminium frame for door of size 65X38 mm including anodized aluminum push/pull glazed type shutter with lock rail, top rail and stiles of size 84X38mm and size 115X44mm for bottom rails and necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium handles, including supply and fixing for 5.5 mm thick sheet glass, tinted and minimum 4 Nos 100mm long aluminium hinges per shutter complete all as specified and directed.
S&F for anodized aluminium framed for window with one or more rebates including anodized aluminium window, sliding type shutters, sliding on two way aluminium channel, without sash bars, sliding on separate track, made out of aluminium section weighing 0.55 Kg/RM and including necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fittings such as suitable anodized aluminium, lock, handle etc including 4mm thick sheet glass, tinted complete all as specified and directed.
S&F for factory made steel windows with side hung shutters including box type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for factory made steel windows with side hung shutters including box type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
M&L for second class hard wood in fillets, square, rectangular or triangular in section, clean swan, fixed with nails, sectional area not exceeding 3 sqcm complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/hard standing etc including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded aggregate) used as in beams, cantilever, lintel over 1.50 span etc complete all as specified and directed.
M&L for from work to slab, sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hoping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) in vertical surface of size 450mmX 350mmX7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) in vertical surface of size 300mmX 200mmX7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No.44.00 here-in-before but in skirting over and including a backing coat of 10mm thick bed in cement mortar (1:4) complete all as specified and directed.
M&L for machine cut kota stone slab flooring (pre-mirror polished) 20-25mm thick over and including 15mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20 mm thick granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing over and including 15 mm thick screed bed of cement mortar (1:6) including dismantling old granite, bedding complete all as specified and directed.
M&L for 20mm thick granite (of any type) tiles machine cut, in wall/skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including a backing coat of 10mm thick bedding in cement mortar (1:4) including dismantling of old granite, bedding complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20 mm thick, 1st coat 10mm thick in cement mortar (1:6) & 2nd coat 10mm thick in cement mortar (1:4) with water proofing compound @ 2% by weight of cement, plastered surface shall be finished even and smooth with using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkali resistant primer over and including applying 1 mm thick wall care putty after complete removal of existing treatment of old plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkali resistant primer over and including applying 1 mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying three coats of colour wash (colour as approved by GE) on surface of wall including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of colour wash (colour as approved by GE) on surface of wall including preparation of old plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 all as specified and directed.
S&F for vitreous china wash basin (oval type), white, flat back, size 560 X 450mm, excluding taps, chain and plug and porcelain stopper but including waste pipe and coupling, brackets and cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed. (Make: Hindware Cat No. 10049 or equivalent of Parryware/Cera/Jaquar as approved)
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F for 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 100 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 100 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S&F for 15 mm dia angular stop valve cast copper alloy, chromium plated, screwed down high pressure, with capstan head screwed both ends for iron pipes or for unions of fancy type fixed complete as in repairs all as specified and directed .
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks &fly nuts, screwed for iron pipes complete as in repair all as specified and directed.
S&F for 15mm dia bib taps, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete as in repair all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete as in repair all as specified and as directed.
S&F for mild steel flat iron as in hold fast and wind tie including all necessary drilling, bolting or riveting etc and similar work complete conforming to Fe-290 Gde E-165 complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 15 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 79.00 above)
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 20 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 20 mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 82.00 above)
S&F for 20 mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specifid and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (oceanic) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form after and including dismantling of old false ceiling complete as per the drawing & directions of Engineer-in-Charge.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for aluminium extruded body door closer hydraulically regulated designation No. 1, universal type, suitable for door shutters upto 700 mm in width and of weight not more than 35 Kg as complete fixed in repairs all as specified and directed.
S&F for mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for rolled mild steel angle iron roof trusses (framed) and purlins, rafters etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' all as specified and directed.
S&F for 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate complete as in repair all as specified and directed.
Surface excavation in soft /loose soil not exceeding 15 cm deep and getting out complete all as specified and directed
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for DPC in cement concrete 40mm thick (1:2:4) type B-0 (using 12.5mm graded aggregate) complete all as specified and directed.
M&L for broken brick hardcore of gauge exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in subbase to floor complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate) as in floor finished even & smooth with using extra cement complete all as specified and directed.
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface complete all as specified and directed.
M&L for point wiring (concealed) complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box of 1.20mm thickwith top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of bakelite laminated top cover of 3mm thick , blanking plate as per numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One fan point/ exhaust fan point controlled by one switch and one regulator.
One 3 pin 5/15 amps socket outlet point controlled by one 15 amps switch on same board.
One 3 pin 5/15 amps socket outlet point controlled by one 15 amps switch on independent board.
All as per Item No.100.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 16 Amps socket outlet on independent board complete all as specified and directed .
S&F for LED 18 Watt light fittings suitable for LED T8 lamp, pre wired including necessary electric connection with required size copper cable after and including taking down any type of old tube light fittings including lamp complete all as specified and directed . (Make : Crompton Greaves cat No : DIJB12LT8-20/ Havells cat No : REGALBATTENT8UPTO1X18WDSBSWH as approved)
S&F for 18 watt linear LED T8 tubular lamp with extruded aluminium body / polycarbonate diffuser with inbuilt driver complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRA1213T8SSTL18WLED865SPC as approved)
S&F for recess mounting 2'x2' LED 36 Watt light fittings with LED lamp and required driver, slimmest 9 mm thin in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete as in repair all as specified and directed, (Make: Crompton Cat No.LCPL-36-CDL(2x2) / Havells Cat No.ENDURASLIMPROPLUS2X2PLR36WLED857MOD as approved )
S&F for angle lamp holder, insulated body with back plate for batten fittings including LED lamp 12 watts complete all as specified and directed.
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts, single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano, flush type, single pole, one way, 5/6 Amps, 240Volts, ISI marked, AC complete as in repair all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete as in repair all as specified and directed.
S&F for switch piano flush button, single pole, one way 15/16 amp 240 volts, AC, ISI marked complete as in repair all as specified and directed.
S&F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole, MCB 20 Amp, 240V, 'C' series ISI marked complete as in repair all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F for PVC round/square blocks suitable to fixing tube light fittings and ceiling roses complete as in repair all as specified and directed .
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04GH/ L&T Cat No. DBTPN004GD as approved)
S&F for MCCB, four Pole, 63 Amps, breaking capacity Icu at 415 AC, 50 HZ, 50 KA complete all as specified and directed. (Make : L&T /Havells /Legrand as approved)
S&F for FR-LSH PVC insulated (unsheathed) single core, multistrandad copper cable 10 Sqmm from MCCB to TPN DB complete all as specified and directed.
S&F for MCB four pole, 100 Amps 10 KA, "C" series, AC, 240Volts, 50Hz , ISI marked complete all as specified and directed. (Make- Legrand / Hager / Havells as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and as directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 12 way for flush mounting with 200amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 22 12 way / Hager cat No.VYS12G / L&T Cat No. DBSPN012GD as approved).
S&F for MCB, double pole, 40 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand / Hager / L&T as approved)
S&F for MCB SP 6 to 32 Amps 10 KA, "C" series, AC, 240Volts, 50Hz , ISI marked complete all as specified and directed. (Make:- Legrand / Hager / Havells as approved)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 70 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable existing service/UG cable complete all as specified and directed . (NOTE: Excavation/earth wall, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Excavation in trenches for foundation, laying under ground cable, erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed
M&L for brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for GI pipe 50mm dia (medium grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection including taking out old rusted/unserviceable steel tubing complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 40mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer complete all as specified and directed.
S&F for LED street light fittings Indus series IP-65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 30 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-30-CDL/ Havells Cat No ENDURACITYLITEPLATPLUSSL30W757SASYB0PC as approved)
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, connecting wire from ceiling fan, ceiling rose or connection complete all as specified and directed.
S S ENTERPRISE
DEYS ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .