Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.8 L+₹1.1 L (5.24%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹25.5 L+₹3.9 L (18.0%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-Finance Other than lowest Bidder | |
| 4 | L4₹29.6 L+₹8.0 L (36.9%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance Other than lowest Bidder | |
| 5 | L5₹32.7 L+₹11.0 L (51.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2021, 6:00 pmClosed
HQ CWE (AF) CHILODA
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
REPAIR MAINTENANCE OF DG SET TRANSFORMER VCB LT PANELS MCCBs AND MISC EM WORKS AT AREA B AT AF STATION WADSAR UNDER GE (AF) CHILODA
2021_MES_445002_1
82080/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Gandhinagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (AF) CHILODA
₹60,000
Yes
30 Jun 2021
22 May 2021
21 Jun 2021
22 May 2021
19 Jun 2021
5 Jun 2021
23 May 2021 - 4 Jun 2021
Amount
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) un reinforced complete all as specified
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified
Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified
M&L Sand filling with clean dry fine river sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified. Note:- Punned thickness shall only be measured for payment.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding. 1.5 m above the starting point
M&L PCC 1 : 3 : 6 type C1( Using 20 mm graded crushed stone aggregate) for foundation / concrete blocks / earthing chamber / chamber cover complete all as specified
M & L Bricks laid in trenches for cable protection, well burnt sub class ‘B’, abutting each other width equal to length complete all as specified
M&L Painting to steel surfaces of feeder pillar box with one coat of synthetic enamel paint including preparation of surfaces complete all as specified
S&F 40 mm bore GI tubing, light grade galvanized with all fitting and fixed to walls and ceilings or laid in floors for earthing strip protection as in repairs complete all as specified
S&F 50 mm bore GI tubing, light grade galvanized with all fitting and fixed to walls and ceilings or laid in floors for cable protection as in repairs complete all as specified
S&F 80 mm bore GI tubing, light grade galvanized with all fitting and fixed to walls and ceilings or laid in floors for cable protection as in repairs complete all as specified
S&F 15 mm bore GI tubing, medium grade galvanized with all fitting and laid in trenches as in repairs complete all as specified
S&F 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends to iron pipe and fixed complete all as specified
M&L Cross arms, bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, weldsing, bending cold or hot drilling holes for bolts any shapes of size as indicated or direct and inclusive of one primer coat, one under coat and one finishing coat of paint
M & L Drop Out fuses (expulsion fuses) single pole, 11000 volt above 25 & upto 50 Amp as in repairs all as specified.
S&F Switch air break gang operated triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism working out from ground level for current rating 200 amps suitbale for 11 KV complete all as specified and as directed.
S&F Lightning arrester (expulsion type) complete with all fittings, transmission class discharge capacity 65 KA suitable for 11 KV complete as in repairs all as specified
M & L Cable jointing kit (Heat shrinkable) for 11 KV(earthed) grade cable for indoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of size 95 Sqmm complete as in repairs all as specified.
M & L Cable jointing kit (Heat shrinkable) for 11 KV(earthed) grade cable for outdoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor of size 95 Sqmm complete as in repairs all as specified.
M & L Cable jointing kit for 11 KV(earthed) grade cable for straight through Hot shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminim conductor of size 95 Sqmm complete as in repairs all as specified
M&L Reinforced precast concreate cable cover, HV , flat size 450mm x 230mm x 50 mm complete all as specified
Supply,laying and testing XLPE insulated, PVC sheathed, armoured, heavy duty, aluminium conductor LT, 1100/11 KV Volts grade including taking out old/unserviceable underground cable XLPE insulated, PVC sheathed, armoured, heavy duty aluminium conductor HL/LT, 11/1.1 KV Volts grade cable, fixed on walls and trenches etc for the following sizes complete all as specified
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
95 Sqmm 3 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
400 Sqmm 3.5 core
500 Sqmm 3.5 core
S & F Terminal connections complete of required size aluminium lugs etc as in repairs including taking down unserviceable MCCBs for the followings sizes :-
MCCB TP 630 amp Adjustable type 50 KA
MCCB TP 400 amp Adjustable type 36 KA .
MCCB TP 200 amp Adjustable type 36 KA .
MCCB TP 160 amp Adjustable type 36 KA
MCCB FP 630 amp Adjustable type 50 KA
MCCB FP 400 amp Adjustable type 36 KA .
MCCB FP 200 amp Adjustable type 36 KA .
MCCB FP 160 amp Adjustable type 36 KA
MCCB TP 125 amp fixed type 16 KA
MCCB TP 100 amp fixed type16 KA.
MCCB FP 100 amp fixed type 16 KA.
MCCB FP 125 amp fixed type 16 KA.
MCCB FP 63 amp fixed type 16 KA.
MCB TPN 63A, C Curve
MCB TP 40 A,C curve
S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors screws etc. for roof conductors ground as in repairs complete all as specified
S&F Copper Strip of size 20 X 3 mm buried/laid in trenches/fixed on wall/tower etc complete as in repairs all as specified.
M&L Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.3mm burried directly in ground level with teop edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete.
M&L Earthing complete with copper earth plate electrode 60 x 60cm x 3.15mm burried directly in ground level with teop edge of earth plate at a depth not less than 1.5m below ground level connected to and including copper earthstrip 20 x 3mm as earthing lead including earth test point by means of bolts, nuts, check nuts and washers etc made of copper and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required copper strip 32x 6 mm complete as in repairs all as specified.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required copper strip 20x 3 mm complete as in repairs all as specified.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
S&F Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1mx minimum2.5 mm thick complete as in repairs all as specified.
M & L Anti climbing device,spikes type fabricated out of MS bar round,square,flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete as in repairs all as specified.
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete as in repairs all as specified.
S & F Danger notice plate of 1.6 mm thick MS sheet,vitreous enamellers white,figures & conventional shulls,bones in singal red colour affixed with MS clamps,bolts of approved size for HT 25 x 20 cm sizecomplete as in repairs all as specified.
S &F Air temination, single pointed aluminium rod 12mm dia and 300mm long complete as in repairs all as specified.
S &F Air temination, single pointed copper rod 12mm dia and 300mm long complete as in repairs all as specified.
M& L Test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25 mm drilled & screwed including 3 hole,8mm dia 25mm long hexagonal head with nuts & washers complete as in repairs all as specified.
S& F Flat twin core cable weather proof Aluminium Conductor of size 6 sqmm complete as in repairs all as specified.
M&L Coarse aggregates, grading l, 90 to 40 mm size or grading 3, 50 to 20 mm size granite for spreading on ground for Four/Two pole structure.
Disconnecting and removing outdoor transformer after disconnecting HT/LT cable terminals connections and lowering down from plinth/platform structure of following capacity
M&L Opening the top cover/lid for periodical maintenance such as cleaning of transformer core,cleaning of oil tank to remove sludge deposit etc. of following capacities
Transportation of transformer/Voltage Stabliser/DG Set- to nearest workshop for repair/replacement of transformer/Voltage Stabliser/DG Set- winding and return back for installation in its original position / location after repairing from workshop upto 400 KVA capacity (Rate is inclusive only transportation, T&P and manpower ) complete all as specified and as directed by Engineer-in-charge.
Shifting of serviceable transformer/Voltage Stabliser/DG Set- upto 400 KVA from MES store yard / sub-stn (indoor / outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer upto 500 KVA complete all as specified and as directed by Engineer-in-charge
M & L Cleaning bus bar with CRC solution - 2.26, 200ml spray bottle with the help of cotton waste etc complete all as specified and as directed by Engineer-in-charge.
M&L Rewinding of HT coils with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding,Baking the core assembly with the help of oven duly varnshing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for seperately) complete all as specified
All as per item No 48 above but LT coil with copper strips
M & L Re-arranging the top core over coils in proper manner aftr proper cutting out & leaking including fixing of top channel soldering in between coils as necessary and brazing of star delta connection with tap changer for any size of transformer complete all as specified and as directed by Engineer-in-charge
S&F Replacement transformer Bush rods brass as per existing dia/size of HT/LT side including set of brass,washer,nut & bolt etc for indoor / outdoor transformer of following sizes
S&F Porcelain insulating bush of transformer HT 11 KV conical bush / gasket for indoor / outdoor size upto 400 KVA complete all as specified
S&F Silica gel breather assembly having iron cap at top & bottom and tighten with suitable size of nuts & bolts filled with silica gel for size of transformer 100KVA to 400 KVA all as specified
S& F Refilling of silica gel in existing servicable breather assembly all as directed by Engineerin charge
M&L Dehydration including filtration and cleaning of transformer/Voltage Stabliser at site by dehydration machine till to achieve Di-electric strength 60 KV at 2.5 mm gap including testing of sample before and after dehydration and filtration complete all as specified and as directed by Engineer-in-charge. NOTE : -(i)Contractor has to arrange the dehydration machine and testing kit without any extra cost (ii). Labour for draining out of oil & refilling the same is deemed to be included in quoted rates. (iii)Cost of minor spares ie nut bolt and washer if required to complete the job is deemed to be included in quoted rates.
M&L Transformer oil low viscosity type conforming to IS-335 (Latest revision) for topping up of transformer (having dielectric strength 60 KV with 2.5mm gap) complete all as specified and as directed by Engineer-in-charge Make: SERVO/POWER OIL.
M&L Tap changer with tapping arrangement 5% and 7.5% on normal tapping complete as in repairs all as specified
M&L Gun metal gate valve with iron iron wheel head of 25/20 mm dia heavy duty ISI marked complete incl providing necessary rubber packing to stop leakage complete as in repairs all as specified
S&F Synthetic rubberized corksheet/gasket of 6mm thick for fixing top cover and HT / LT side transformer bushes as in repairs for the following capacity
M&L Preparation of old painted surface of steel surface of transformer by brushing / cleaning strain grease / oily spots with thinner and two coats of spray painting with spray machine to transformer indoor / outdoor fixed on pole or in sub station at different location capacity upto 400 KVA including writing SM No, MES No as per requirement complete all as specified
S&F Temperature gauge of range 0-100 degree celcius as in repairs all as specified.
M & L Machine spray painting to voltage stablizer of capacity 300/150/100/75 KVA rubbing, scraping of old paints with emery paper, cleaning and preparation of smooth surfaces complete with approved quality paint as directed by Engr in charge.
M&L Defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation to required depth in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 95 sqmm 3 core. The fault located equipment shall be brought at site within 02 hours of Instruction received from JE/ Engineer-in-charge complete all as specified
Disconnecting terminals of LT cable and locating pin point fault in LT cable 1100 Volts grade of any size including hire charge of special T & P all as directed by the Engineer-in-Charge.
Taking out unserviciable underground cable of any size (4x16 Sq mm to 3.5x400 Sq mm) 1100 volt grade & bricks, tracing out the defects, rectify the same, making servicable by removing/cutting unserviciable & burnt out part jointing with straight through joint of suitable size, testing with megger etc. (Straight through joints shall be measured and paid separately.)
M&L Relaying and testing of serviceable under ground XLPE cable retrieved from item No 62 here in before after cutting into pieces serviceable portion for the following sizes:
Under ground cable of size 3.5 x 400/300/240 Sq mm.
Under ground cable of size 3.5 x 185/150 Sq mm.
Under ground cable of size 3.5 x 120/95 Sq mm.
Under ground cable of size 3.5 x 35/50/70 Sq mm.
Under ground cable of size 3.5 x 16/25 Sq mm.
S&F Bus bar chamber, wall mounted 100 amp, 4 way current rating, factory , dust and vermin proof including bus bar of rectangular cross section of copper strip supported on case epoxy insulator at suitable interval heat shrinkable sleeves with proper colour code 01 set of 04 strips, complete with grouting in wall with suitable F1 Srip bent to shape, with PCC work for holding enclosure as directed by Engr in charge
M & L Straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x25-50 Sq mm complete all as speciied
M & L Straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x70-95 Sq mm complete all as speciied
M & L Straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x120-185 Sq mm complete all as speciied
M & L Straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 4x240-300 Sq mm complete all as speciied
M & L Straight through joint 1.1 KV for XLPE U/G cable Heat Shrink type of size 400 Sq mm complete all as speciied
Re-laying serviceable bricks obtained from dismantling of UG cables against item No 62 here in before .
M & L Boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique complete all as directed by Engineer-in- charge. Note:- Pipe for protection of cable shall be measured and paid separately.
M&L Cable path indicator made of RCC (size 0.2 mtr x 0.1 mtr x 0.75 mtr height) 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars 100 mm c/c horizontally vertivally,voltage & cable size mentioned in bold letters painted with brown paint & back ground with two coats of yellow paint in foundation PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate of size 0.3 mtr x 0.2 mtr x 0.3 mtr including necessary excavation & earth work complete all as specified
M & L Servicing of servo controlled voltage stabilizer 300/150 KVA, 415 volt including setting of input and output voltage complete all as directed. Note:- Spare required for replacement if any will be measured and paid separately.
M & L Servicing of Servo controlled voltage stabilizer 100/75 KVA , 415Volt including setting of Input and Output voltage complete all as directed. Note:- Spare required for replacement if any will be measured and paid separately.
Supply only following spares for servo controlled voltage stabilizer of 300/150/100/75 KVA suitable for existing make
Shunt Trip coil of any size
Cut out PCB,3-phase
Micro-controller PCB with connector
Control cabling with glass fuse
Indication lamp, 22.5 mm dia, R - Y- B
Push button,12.5 dia,R -Y-B
Single phase , Synchronise AC motor, 10 KG
RC network for 10 KG motor
Sensing Transformer for Digital/analog control
Aluminium Busbar of any size and any capacity.
M&L Rewinding of Stabiliser buck boost transformer/Variable voltage transformer ,single phase. I/P -0-144 VAC,O/P- 0 -85 VAC with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding,
Stabiliser carbon Brush for Dimmer
S& F ON LOAD change over switch with sheet metal Enclosure 63 amp , 4 pole , including necessary cable connections as in repairs complete all as specified.
S& F ON LOAD change over switch with sheet metal Enclosure 100 amp , 4 pole , including necessary cable connections as in repairs complete all as specified.
S& F ON LOAD change over switch with sheet metal Enclosure 125 amp , 4 pole , including necessary cable connections as in repairs complete all as specified.
S& F ON LOAD change over switch with sheet metal Enclosure 200 amp , 4 pole , including necessary cable connections as in repairs complete all as specified.
S& F ONLOAD change over switch open execution 400 amp , 4 pole complete as in reapir all as specified
S& F ONLOAD change over switch open execution 630 amp , 4 pole complete as in reapir all as specified
S& F Voltmeter digital type 96 x 96 mm square, 0-500Volt.complete as in reapir all as specified
S& F Ammeter Digital type 96 x 96 mm square , 0-200Amp, including suitable CT's complete as in reapir all as specified
S& F Aluminium lugs of sizes 300/150/95/50/35/25 Sqmm complete as in reapir all as specified
S&F APFC relay 8/6 stage, 144 x 144 size complete as in reapir all as specified
S&F CT Coil, 150/5 amp.complete as in reapir all as specified
M & L Control wiring in APFC panel with copper flexible wire 2.5 Sqmm complete as in reapir all as specified
M&L Servicing of APFC panel of any rating to maintain the power factor at optimum level & producing servicing certificate. Note:- Addtional parts ,if required will be measured and paid separately.
S&F Contactor for 25 KVAR complete as in repair all as specified
S&F Contactor for 15/20 KVAR.complete as in repair all as specified
S&F Contactor for 5/10/12.5 KVAR.complete as in repair all as specified
S&F KVAR capacitor 5 to 10 KVAR complete as in repair all as specified
S&F KVAR capacitor 12.5/15/20 KVAR complete as in repair all as specified,
S&F KVAR capacitor 25 KVAR complete as in repair all as specified
S&F HRC Fuse of 100/125 A capacity complete as in repair all as specified
S & F Fuse Copper Wire of suitage gauge for HT incoming supply complete as in repair all as specified
Repairs/ servicing to 82.5 KVA DG set at AF Net BRD with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality, and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed consisting replacement of the following parts: (i)Fuel filter -01 Set (ii) Oil filter (Spinon/Centrifugal type) - 01 Set. (iii) Air filter - 01 Set (iv) Engine oil - (Full Tank capacity) (v) Coolant -(Full Tank capacity) Notes : (i) The contractor should carry out servicing through authorised OEM & not by any local mechanic (ii) The contractor should be responsible to maintain the DG set in serviceable condition for entire contract period & additional worn out spare parts like O Rings,gasket,screws, etc if found unserviceable should be replaced by contractor without additional cost . (iii) Proper servicing certificate should be produced immediately after servicing as directed by Engineer-in-charge.
Repairs/ servicing to 160KVA DG set at R&C Lab with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed consisting replacement of the following parts:- (i)Fuel filter -01 Set (ii) Oil filter (Spinon/Centrifugal type) - 01 Set. (iii) Air filter - 01 Set (iv) Engine oil - (Full Tank capacity) (v) Coolant -(Full Tank capacity) Notes : (i) The contractor should carry out servicing through authorised OEM & not by any local mechanic (ii) The contractor should be responsible to maintain the DG set in serviceable condition for entire contract period & additional worn out spare parts like O Rings,gasket,screws, etc if found unserviceable should be replaced by contractor without additional cost . (iii) Proper servicing certificate should be produced immediately after servicing as directed by Engineer-in-charge.
Repairs/ servicing upto 62.5KVA DG set at PH 15 BRD with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed consisting replacement of the following parts:- (i)Fuel filter -01 Set (ii) Oil filter (Spinon/Centrifugal type) - 01 Set. (iii) Air filter - 01 Set (iv) Engine oil - (Full Tank capacity) (v) Coolant -(Full Tank capacity) Note (i) The contractor should carry out servicing through authorised OEM & not by any local mechanic (ii) The contractor should be responsible to maintain the DG set in serviceable condition for entire contract period & additional worn out spare parts like O Rings,gasket,screws, etc if found unserviceable should be replaced by contractor without additional cost . (iii) Proper servicing certificate should be produced immediately after servicing as directed by Engineer-in-charge.
M & L Spray painting to 82.5/62.5/160 KVA Diesel Engine, alternator, base frame & control panel board by applying 02 coats of approved colours synthetic enamel paint over a coat of primer including taking necessary precaution to avoid any painting in measuring instruments, hoses, fuel pipe & other parts indicated as by Engineer-In-Charge
M&L Solenoid switch for 82.5 KVA, 62.5 KVA, and,160 KVA DG set complete all as specified and directed.
M&L Oil pressure gauge for 82.5 KVA, 62.5 KVA, 160 KVA DG set complete all as specified and directed.
M&L AMF relay digital type with LED screen suitable capacity of CTs for 82.5/62.5/160 KVA DG set complete all as specified as directed by Engr-in-charge.
M&L Fan belt suitable for DG set(As per sample) complete all as specified as directed by Engr-in-charge.
M&L Fuel pipe for DG set(As per sample) complete all as specified as directed by Engr-in-charge.
S&F Brass terminal lugs for 12V lead acid battery complete as in repairs
S&F Copper lead for 12V lead acid battery complete as in repairs
S&F Exide battery 12 volt, 130AH complete as in repairs
M & L Fuel gauge suitable for 160/82.5/62.5 KVA DG set as per existing make of DG Set.
M & L AVR for 1 phase/3 phase suitable up to 160 KVA DG set as per existing make of DG Set.
M & L VAF meter with suitable capcity of CTs for 62.5/82.5/160 KVA DG set complete all as specified and as directed by Engineer-in-charge.
M&L Rewinding of Alternator Main Stator/Rotor Winding with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding complete all as specified
M&L Rewinding of Excitor Main Stator/Rotor Winding with super enameled copper wire / strips DPC / super enameled matching with existing gauge and insulating material of high class as per manufacture recommendation with packing / insulation material in each layer of winding complete all as specified
Maintenance & repairing of 1.1 KV,800 Amp LT ACB panel,dusting oiling if any,setting of over current and earth fault relay setting all as specified laid and servicing like all mechanical function complete all as specified
S&F No Volt Coil suitable for LT ACB complete all as specified
M&L Servicing and maintenance of VCB with relay testing and high voltage and relay setting corrections complete all as directed by Engineer-in-Charge.
S&F Spares for HT VCB as per existing make/ model in repairs complete all as specifed :-
Spring charging motor
BKR Auxiliary switch
Closing coil
Tripping coil
Insulation shrouds
Maintenance & servicing of 11 KV,HT RMU with checking following work:- (a) Load Break Switch:- (i) On-Off Operation Checking. (ii) Interlocking of the LBS. (iii) Hardware tightening of the mechanism (iv) Latch Roller Condition (v) LBS lever lubrication (vi) Aux Switch setting if unit is motorized. (b) Circuit Breaker (i). On-Off Operation of CB. (ii). Tripper Setting. (iii). Cable Box Interlock of the CB, (iv). Pad Lock of CB. (v). Cam Setting. (vi). Reset spring setting. (vii). Lubrication to required parts. (viii). Neutral Catch Setting. (ix). Off to reset Wire setting. (x). Aux Switch Setting. Notes: (i) The contractor should carry out servicing through authorised OEM & not by any local mechanic (ii) Proper servicing certificate should be produced immediately after servicing as directed by Engineer-in-charge.
Testing of 11 KV,HT RMU with following work:- (i) .Relay Primary Injection test. (ii).Insulation Resistance. (iii). Contact Resistance. (iv). Tripper Coil resistance. (v) Battery Bank replacement Note for item Nos 118.00 & 119.00 (i) The contractor should carry out servicing through authorised OEM & not by any local mechanic (ii) Proper servicing certificate should be produced immediately after servicing as directed by Engineer-in-charge.
M & L Servicing of EOT crane 5 Ton, 3 phase/Single phase dismantling parts by parts greasing and replacement of worn out part and refixing and testing as per manufacturers specification as specified and directed by Engr -in - Charge.
S & F Wire rope 11 mm dia for 5 ton EOT crane as in repairs.
S &F Limit switch for 5 ton EOT crane as in repairs as per sample.
M & L Testing of earthing resistance value with digital type earth tester at different locations of are 'B' on Monthly basis up to the entire satisfaction of AF personnel & submitting the earth result all as directed.
M&L Tightening and fixing in position loose hanging copper/aluminium strip of any size on wall or building roof using new insulators of porceline of approved size and fixing existing copper strip on the same position aomplete all as specified.
S&F Ceramic supporter with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc complete as in repairs all as specified .
S & F First aid box, containing the following medicine and accessories as medical kits all as specified and as directed. (i) Adhesive tape (ii) Anesthetic spray ( Bactine) or lotion ( Calamine, Campho-Phenique) - for itching rashes and insect bites (iii) 4" x 4" sterile gauze pads - for covering and cleaning wounds, as a soft eye patch (iv) 2", 3", and 4" Ace bandages - for wrapping sprained or strained joints, for wrapping gauze on to wounds, (v) Adhesive bandages (all sizes) (vi) Diphenhydramine (Benadryl) - oral antihistamine for allergic reactions, itching rashes. Avoid topical antihistamine... (vii) Pocket mask for CPR
S & F Electric shock treatment board made up of flux sheet with printed standard matter in three versions(i.e Hindi,English & Gujrati) & standrad drawing over a layer of polythene film pasted on wwoden ply board of 6 mm thick with all edges fixed with wooden beedings complete as in repairs all as directed. The over all size of the board shall not less than 1.20 Mtr x 0.90 Mtr
M&L Colour coding of earthing pit cover with the following colour:- Red for chemical earth pit.Yellow for conventional earth pit. The numbering/marking of earth pit will be in capital black colour and is to be done as directed by Engineer -in- Charge.
M& L Industrial salt for earthing pit recharging all as directed by Engineer in charge
M& L Technical grade Magnisium Sulphate for earthing pit recharging all as directed by Engineer in charge
M&L Mild steel chequered plate, 5mm thick or over in thickness, grade Fe-290 (Gde E-165) in available sizes for duct cover complete.
Supply, install, testing and commissioning weather and vermin proof LT feedar pillar box (Panel board)in replacement factory fabricated outdoor type canopy top factory lock front and back opening totally enclosed made out of 3.15mm thick sheetmetal enclosure of suitable size with angle iron frame of MS angle 50 X 50 X 6mm upto 1.5 mtrs length from ground level duly powder coated of size 900 x 600 x 350 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and side locking arrangement consisting of sufficient Nos of circular cables entrly holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc. inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium and LT panel should be CPRI approved and factory fabricated complete all as specified and directed and consisting of the following:- (i) MCCB 200 Amp 4 Pole(AC 415 Volt), 36 KA-01 No (ii) 63 Amp MCCB,4 Pole,415V16 KA- 06 Nos (Out going) (iii) Copper bus bar 300 Amp - 01 set (iv) Indicator LED lamp RYB - 01 Set (v) Internal wiring with copper conductor incl necessary lugs and thimbles - 01 Job (vi)Space for 02 Nos of spare MCCB (vii) Changeover Switch-63 Amps
S & F Glow sign board of size 5 feet x 4 feet x 8 inches thick (1640 mm x 1310 mm x 200 mm thick),made out of flex paper roll sheet on 25 mm x 25 mm x 2 mm thick anodised aluminium angle frame, including 4 nos. of 20 W LED lights fitting(internally to the glow sign board) including providing all internal wiring and main connection with 1.5 sqmm single core stranded copper conductor(length not exceeding 10 mtr) complete as in repairs all as specified Note : Matter to be written on the board shall be approved by the Engineer In Charge.
Abhishek Enterprises
ARTI CONSTRUCTION
ALBA AC AND REF SERVICES
M/s PATEL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .