Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-Finance | L1 | Accepted-Finance Lowest Bid | |
| 2 | L2₹6.3 L+₹9,400 (1.53%)Rejected-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹7.6 L+₹1.5 L (23.6%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Higher Bid | |
| 4 | Rejected-Technical 880 1 SC ROAD BATOR HOWRAH 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | - | Rejected-Technical Documents are not in order | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents are not in order |
Tender Value
Refer Docs
EMD Value
₹16,203
Closing Date
18 Jun 2025, 1:00 pmClosed
EE, South 24 Parganas Electrical Division
57/2 Diamond Harbour Road, Kolkata - 700023
Construction of new G plus 1 storied building in the campus of CFTC Budge Budge -- Electrical Installation, Lift, AC, UPS, DG Set, Solar System, Fire Detection and allied works - SITC of Fire Detection System.
2025_WBPWD_858603_1
WBPWD/EE/S24PED/eNIT09_2nd Call/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Budge Budge
Please refer Tender documents.
4 documents required · 4 mandatory
₹16,203
South 24 Parganas Electrical Division
7 Jul 2025
4 Jun 2025
20 Jun 2025
4 Jun 2025
18 Jun 2025
13 Jun 2025
12 Jun 2025
Amount
SITC of Microprocessor based addressable fully networkable fire alarm control panel (VDS / UL-FM approved) suitable for the devices as stated in thefollowing items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with min. 600 character alpha-numeric liquid crystal display.
Thc panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. [Approved make : Honeywell / Siemens / Edward / Bosch / Jhonson Control / Securiton / Secutron]
SITC of of Micropresssor controlled IP Addressable Intelligent Optical-Thermal Multi-criteria Detector (VDS/UL-FM approved) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring, complete with base. (Numbers of addressable devices in a group will be as per latest recommended standards) (Make : Honeywell / Siemens / Edward / Bosch / Jhonson Control / Securiton / Secutron).
SITC of IP Addressable Manual call point (VDS/UL-FM approved) with in built short circuit fault isolator as per NFPA style 7 wiring. (Numbers of addressable devices in a group will be as per latest recommended. (Make : Honeywell / Siemens / Edward / Bosch / Jhonson Control / Securiton / Secutron).
SITC of Addressable Hooter-cum-Strobe (VDS/UL-FM approved) (sound output of minimum 90 db) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. (Numbers of addressable devices in a group will be as per latest recommended standards) (Make : Honeywell / Siemens / Edward / Bosch / Jhonson Control / Securiton / Secutron).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make : Finolex / Havells / RR Kabel / Polycab) with 20mm NB PVC 'FR' rigid conduit pipe (Red Colour) on the surface of the wall. (Make : Polycab/Presto/Precision-Medium).
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
Computer Gallery (BID ID -6595179)
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD (BID ID -6592310)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .