Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.7 L+₹65,166.45 (3.62%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jan 2022, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR AND MAINT OF DG SETS AND AMF PANEL AT AF STATION JODHPUR
2021_MES_497426_1
8499/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (AF) Jodhpur
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
4 Feb 2022
24 Dec 2021
21 Jan 2022
24 Dec 2021
19 Jan 2022
7 Jan 2022
Amount
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 15 KVA & upto 50 KVA , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in repair in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 62.5 KVA & upto 100 KVA , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in repair in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 110 KVA & up to 160 KVA , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in repair in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 160 KVA & upto 250 KVA , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in repair in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Material & Labour for comprehensive maintenance and general servicing of DG Set of capacity 250 KVA & upto 400 KVA , dismantling and replacement of worn out/Defective spare parts, tightening of nut bolts, checking of control wiring connections, cleaning of platform,removal of sludge from platform & also from inside of canopy of DG set including minor material like ; grease, thread, minor gaskets required for servicing etc and re-assembling of DG set, Installation on the same place, making connection , testing on full load complete to the entire satisfaction of the Engineer in Charge. Note : - (a) If any part will be replaced it will be measured and paid as supply only in repair in respective items given here in after. (b) The rate quoted for this item also includes quarterly maintenance of DG Sets like cleaning of DG Sets ; tightening of nut bolts, checking of control wiring connections, cleaning of platform and removal of sludge from platform & inside canopy of DG set as directed by the Engineer in charge. A register shall be maintained by the JE Concerned & to signed by the JE, AGE and contractor. (c) DG Sets are of the Makes ; Kirlosker/Birla Power/Volvo/TATA/ Mahindra/Crompton Greaves/Ashok Leyland/Cummins
Supply only Premixed coolant complete all as specified and directed by the Engineer-in-Charge. Make :- Volvoline, Koel, Fleetguard, Castrol, Bosch & Servo.
Supply only engine oil, multi grade 15w40 in engine complete all as specified and directed by the Engineer-in-Charge.Make :- Indian oil/ Hindustan Petrolium/ Castrol / Pride /Servo
Supply only in repair diesel filter suitable for DG set of capacity above 15 KVA and upto 50 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair diesel filter suitable for DG set of capacity above 62.5 KVA and upto 100 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair diesel filter suitable for DG set of capacity above 110 KVA and upto 160 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair diesel filter suitable for DG set of capacity above 160 KVA and upto 250 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair diesel filter suitable for DG set of capacity above 250 KVA and upto 400 KVA. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Diesel filter suitable for 250 KVA Volvoline DG set.
Supply only in repair Engine oil filter suitable for DG sets of capacity above 15 KVA and upto 50 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Engine oil filter suitable for DG sets of capacity above 62.5 KVA and upto 100 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Engine oil filter suitable for DG sets of capacity above 110 KVA and upto 160 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Engine oil filter suitable for DG sets of capacity above 160 KVA and upto 250 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Engine oil filter suitable for DG sets of capacity above 250 KVA and upto 400 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair Engine oil filter suitable for 250 KVA Volvoline DG set.
Supply only in repair air filter suitable for DG sets of capacity above 15 KVA and upto 50 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greaves.
Supply only in repair air filter suitable for DG sets of capacity above 62.5 KVA and upto 100 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greav
Supply only in repair air filter suitable for DG sets of capacity above 110 KVA and upto 160 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greav
Supply only in repair air filter suitable for DG sets of capacity above 160 KVA and upto 250 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greav
Supply only in repair air filter suitable for DG sets of capacity above 250 KVA and upto 400 KVA complete. Make :- Mico, Bosch, Kirloskar, Fleetguard, TATA, Cummins & Crompton Greav
Material & labour for Repair/replacement of water temperature sensor unit Complete all as specified and directed by the Engineer-in-Charge. Make :- Kirloskar, Cummins,CG & Ashok Leyland.
Supply and fixing in repairs all type of hose pipe, over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings of original make existing in the DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 180 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 150 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs BATTERY 12 Volt 100 AH capacity Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 400 Amp, 36 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 250 Amp, 36 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 200 Amp, 36 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 160 Amp, 36 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 125 Amp, 16 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs MCCB 100 Amp, 16 KA 4 pole 415 V including spreader links complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor of capacity 100 Amps, 240 Volt AC, 2 NO+NC, or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor of capacity 200 Amps, 240 Volt AC, 2 NO+NC, or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor of capacity 160 Amps, 240 Volt AC, 2 NO+NC, or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor of capacity 250 Amps, 240 Volt AC, 2 NO+NC, or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor of capacity 300 Amps, 240 Volt AC, 2 NO+NC, or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge .
Supply & Fixing in repairs Four Pole Contactor coil of capacity 100 Amps 240 Volt AC Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil of capacity 200 Amps 240 Volt AC Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil of capacity 160 Amps 240 Volt AC Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil of capacity 400 Amps 240 Volt AC Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Four Pole Contactor coil of capacity 250 Amps 240 Volt AC Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Autocut Electrical Battery Charger Unit 12V DC, 10 Amp SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Autocut Electrical Battery Charger Unit 24V DC, 10 Amp SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs under Voltage Monitor Relay, 3 Phase AC, 110/415V, AC Setting 75-100/300-400V, Trip Time 0-10 Sec Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Timer AC/DC on Delay, AC 110/220V AC DC 24/12, 1-10, 3-30, 10-100 Sec Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Engine Start Relay, 12/24 V DC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable. Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Copper Conductor Control Cable of 12core, sectional area 1.5 Sqmm (each core) Multistranded for DG Set to AMF Panel Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repair of DC 12V Self Solenoid Coil suitable for DG Set of any capacity of make as orginal existing in DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs DC 24V Online Solenoid suitable for DG Set of make as orginal existing in DG set Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG Set PLC for DG set (PS 500 unit for CUMMINS) Complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs Microprocessor/Alfa-Numeric Based DG set PLC for DG set (PLC FOR Mahindera/ Ashok Leyland DG SETS) Complete all as specified and directed by the Engineer-in-Charge.
Material and labour for repair/overhauling of self starter upto 125 KVA 12 Volts of make : Lucas, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing Complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Oil Pressure switch 2Pin or 3Pin of original make existing in self starter complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Battery terminal made of Brass of original make existing in self starter complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Battery Led of self starter of original make existing complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs Fan Belt of self starter of original make existing complete all as specified and directed by the Engineer-in-Charge .
Material and labour for opening of AMF Panel, Cleaning of dust using blower & cleaning agents, Checking for faults, Removal of Faults, Re-wiring of old unserviceable wiring, Testing of Control Wiring complete as required and closing of AMF Panel after replacement of unserviceable parts and testing on completion of job on existing load including cleaning and removing the sludge from DG set Complete all as specified and directed.
Supply & fixing in repairs AMF Controller (PROCOM UNIT) for AMF Panel for 12V and 24 V both supply Complete all as specified and directed.
Supply & fixing in repairs Auxiliary Relay 14/11/8 Pin 230V AC relays, suitable for AMF Panel of DG Set Complete all as specified and directed.
Supply & fixing in repairs Auxiliary Relay 14/11/8 Pin 12/24 volts DC relays, suitable for AMF Panel of DG Set Complete all as specified and directed.
Supply & Fixing in repairs DC 12 V fuel Solenoid Coil left/right suitable for DG Set of make Cummins Complete all as specified and directed.
Supply & Fixing in repairs DC 24 V fuel Solenoid Coil left/right suitable for DG Set of make Cummins Complete all as specified and directed.
Supply & Fixing in repairs relay card suitable for AMF panel of Make Procom, 12/24 V Complete all as specified and directed.
Disconnecting , dismantling & taking down old unserviceable AMF panel and Supply, installation, testing and commissioning of AMF Panel outdoor type, capacity upto 125 KVA with alluminium busbar of capacity 450 A, TPN powder coated (coloured) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated with inbuilt on load change over switch of 315 Amps, and consisting the following:-
Item No 69.00 Contd... INCOMING from 125 KVA (i) MCCB 250 Amps four pole 25 KA -01 No (ii) Spreaders 250 Amps four pole -01 Set (iii) Extended Rotary handle 250 Amps four pole -01 No (iv) Earth fault module 250 Amps four pole -01 No (v) Power Contractor 300 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No (xi) Inbuilt on load change over switch of 315 Amps for bypassing of AMF panel - 01 No OUTGOING (i) MCCB 250 Amps four pole 25 KA -01 No (ii) Power Contractor 300 Amps four pole AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iii) AMF relay -06 Nos (iv) SMPS 12V, DC, 10A -01 No (v) Emergency stop P.B. -01 No (vi) Digital Amp meter 24 V, DC - 01 No (vii) Digital Volt meter 24 V, DC - 01 No (viii) Control MCB 6A SP 10KA C curve - 03 Nos (ix) Hooter - 01 No (x) Procom Unit (DGC6D) for control - 01 No
Material and labour for repair/overhauling of self starter above 125 KVA and upto 400 KVA, 24 Volts of make : Lucas, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing Complete all as specified and directed by the Engineer-in-Charge .
Supply and fixing in repairs control MCB 6 Amp single pole C curve type Complete all as specified and directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC sheathed, galvanized steel strip or wire armoured, electric power cables 185 Sqmm 3.5 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor laid in trench complete all as specified by Engineer-in-Charge.
Material & labour for replacement of DG set self of 12 Volts capacity suitable for DG set of 125 KVA of make Lucas, Bosch complete all as specified and directed.
Material & labour in repairs for earthing complete with Copper electrode 60 cm x 60cm x 3.15mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of size 20x3mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil, PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 25 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply & Fixing in replacement of liner of suitable size of original make as existing in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of piston of suitable size of original make as existing in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Tepid Valve of suitable size of original make as existing in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Piston ring of suitable size of original make as existing in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of Engine gasket, O ring of suitable size of original make as existing in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of fuel injection assembly with all other connected items in the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Material and labour for Calibration of Fuel injector pump of open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of nosal of the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Supply & Fixing in replacement of CR bearing of the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make ; Mahindra Complete all as specified and directed.
Material & labour for repair, maintenance and overhauling of the open type DG Set of capacity 125 KVA 415 volts 50 HZ of Make- Mahindra including repair of engine head and repair to inlet, outlet valve and all machinery work upto the entire satisfaction of engineer in charge complete all as specified and directed.
Supply & Fixing in replacement of liner of suitable size of original make as existing in the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of piston of suitable size of original make as existing in the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of tepid valve of suitable size of original make as existing in the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of piston ring of suitable size of original make as existing in the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of engine gas kit, O ring of suitable size of original make as existing in the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of fuel injection assembly with all other connected items of canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Material and labour for Calibration of Fuel injector pump of canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of nosal of canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of CR bearing of canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Material & labour for repair, maintenance and overhauling of the canopy type DG Set of capacity 100 KVA 415 volts 50 HZ of Make- Cummins including repair of engine head and repair to inlet, outlet valve and all machinery work upto the entire satisfaction of engineer in charge complete all as specified and directed.
Supply & fixing in replacement of tepid valve of suitable size of original make as existing in the canopy type DG Set of capacity 160 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & fixing in replacement of piston ring of suitable size of original make as existing in the canopy type DG Set of capacity 160 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & fixing in replacement of engine gasket, O ring of suitable size of original make as existing in the canopy type DG Set of capacity 160 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Supply & Fixing in replacement of nosal of canopy type DG Set of capacity 160 KVA 415 volts 50 HZ of Make ; Cummins Complete all as specified and directed.
Material & labour for repair, maintenance and overhauling of the canopy type DG Set of capacity 160 KVA 415 volts 50 HZ of Make- Cummins including repair of engine head and repair to inlet, outlet valve and all machinery work, repair to fuel pump including calibration upto the entire satisfaction of engineer in charge complete all as specified and directed.
Material and Labour for dismantling existing 100 KVA DG set properly disconnecting all electrical connections, panels and DG set, shifting to other location taking suitable safety measures while handling and shifting of DG set from current location to proposed location (within 02 km) including transportaion, required foundation for panels and DG set, reconnection, testing and commisioning complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of locking arrangement of canopy type DG set (04 numbers for each DG set) as existing at site complete all as specified and directed.
Supply & fixing in replacement of flywheel ring for DG set 75 KVA make Kirloskar complete all as specified and directed.
Sopply and top up of battery distilled water used for lead acid battery complete all as specified and directed.
Material and Labour for dismantling the radiator and fan from the engine of DG set of capacity upto 250 KVA for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work; including water pumps assembly for replacement of defective water pumping assembly of oringinal make as per existing in DG Set, and transporting to repair workshop, bringing back including successful re-installation complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for overhauling of DG set 05 KVA Make birla single cylinder including repair of nosal, repair to engine head work, repair to piston rings, cleaning of engine, replacement of fuel pipe and testing the same upto the entire satisfaction of engineer in charge including cost of transportation if any complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for inspection of DG Set as required including checking of engine oil, coolant, fuel and battery termincals on priority basis and testing on completion of job on existing load complete all as specified and directed by the Engineer-in-Charge.
Shri Electrical Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .