Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹33.6 L+₹1.8 L (5.75%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹33.7 L+₹1.9 L (6.05%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹35.9 L+₹4.1 L (12.9%)Rejected-Finance | L4 | Rejected-Finance NOT L1 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
21 Mar 2023, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINE JAMNAGAR
SPECIAL REPAIR TO CERTAIN MASONRY, FLOORING,SANITARY FITTING AND JOINERY ETC IN BLDG NO. P-54 AT INF LINE JAMNAGAR.
2023_MES_583485_1
8961
Open Tender
Civil Works
Item Wise
180 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE A JAMNAGAR
₹64,000
5 Apr 2023
28 Feb 2023
23 Mar 2023
1 Mar 2023
21 Mar 2023
6 Mar 2023
Amount
Demolition of brick work or stone/ boulders masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlars facing, dressed stone work and precast concrete articles, all as specified and directed .
M & L for brick work with sub-class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius built in cement mortar (1:4), complete.
Demolition of (reinforced) cement concrete of any description and in any position not otherwise specifically provided for.
M & L RCC nominal mix type B1 1:2:4 using 20mm graded aggregate as chajja etc and incl necessary formwork all as specified.
M&L for reinforced cement concrete 1:1.5:3 type A1 (20mm graded stone aggt) (nominal mix) as in lintel, beam all as specified and directed ..
S & F TMT steel deformed or twisted bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips.
S & F TMTsteel deformed or twisted bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips. Gde Fe50 or FE 500d
Use and waste of Formwork to sides of concrete foundations, footings bases of columns, raft and raft beams , sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter rough finished surfaces.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
S&F Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in floors/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in Light shade including 15mm thk screed bed in CM 1 :4.
M&L Powder coated aluminium sliding window shutters, aluminium section including necessary joining cleats, glazing clips, Aluminium grill (decogrill Design no 20) and F/h type frame, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.) or hinges type B-21 100 mm long (2 nos.), suitable handle or Star lock, (1 no.) gasket,SS wire cloth 0.36mm dia of wire and average width of aperture 1.40mm incl necessary channel frame work and 5mm thick float glass including fixing arrangement and clips complete all as specified and as shown on drawing NOTE : (ii) Rates include all glazing/ SS wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, etc (iii).comprising frames of section No : 20831 three track top, 20832 three track bottom, 20736 top and bottom shutter, 20738 inter lock, incl "C" channel and "L" angle, roller bearing, rubber beading, consealed lock,
S&F powder coated anodised Aluminium ventilator with fixed aluminium frame of size 60mmx40mmx1.98mm fixed in vertical position with aluminium vertical members and half portion to be provided with aluminum heavy duty adjustable loovers and 4mm thick pinhead glass and remaining portion to be louvered using 4mm thick pinhead glass and louvered portion covered with SS wire cloth 0.36mm dia of wire and average width of aperture 1.40mm incl Aluminium grill (decogrill Design no 20) and F/h type frame, rubber neoprene packing, anodised aluminium snap beading, screws, complete all as specified and as shown on drawing Note : Rates include all glazing/ SS wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading grill loovers etc
Dismantling of MS work of any description not otherwise provided for complete all as specified and as directed
S & F Framed work such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes ; framed guard bars ; barred iron doors ; ladders; framed balusters; walkways ; railings ; framework of water tanks and similar work conforming to to Fe 290. (Gde E-250) Quality-A complete all as specified and dircted
S & F mild steel rolled sections such as in main and cross beams, hip and Jack rafters, purlins, Box section where connected to common rafters and running rails etc fixed with angle cleats or flat iron clamps or other connecting arrangements complete (Grade Fe 410-0 or Fe 310.0)
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm all as specified and as directed.
S&F Pressed steel frames for doors size 105 mm X60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, .
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed.
M & L for PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate) as in pressed steel hollow door section
M&L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S & F for 35mm thick 2nd class hard wood factory made panelled door shutters, plain framed panelled (Two panel) with lock rail & panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The size of rail and style shall be as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 100mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,type B1,complete all as specified and as directed.
S&F Extruded aluminium alloy handles 125mm long, fabricated type, anodised complete all as specified and as directed.
M & L for MS work such as in bands, straps ,supports or stays for rainwater, ventilating pipes, including bolts, heavy, for large gates; clamps, hold fasts etc. & similar small articles conforming to Fe410-0or Fe310-0.
M & L for PCC 1:2:4, type B-1, using (20mm graded stone aggregate), as in hold fast, kerb, kerb stones including necessary formwork.
S & F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring and vucanised rubber piece fixed in floor, overall length of cover plate 140mm.
S&F150 mm long aluminium anodized barrel tower bolts of extruded section.
S&F False ceiling work comprising GI frame work of size 605 x 605mm, for seamless celling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx. 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having knurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long and 4mm thick Non asbestos fibre cement building boards (E-boards) fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling , including taking down old false ceiling including frame work and hangers, complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls incl raking out joints hacking for key, scrubing down with water etc.
M&L 15 mm thick rendering in in two layers 5mm thick in CM 1:4,over 10mm thick cement plaster in CM 1:6 on fair face of brick work/Stone or concrete surface to be finished even and smooth without using extra cemen Including WPC compound 3% by weight of cement.(Note :a) Intergial WPC Compound shall be used in sencond layer,b) Intergial WPC shall be paid seperately on supply only.
M & L Preparation of newly plastered surfaces of wall incl sweeping clean with brush to remove loose dust, sand, by hand held / long handle sander etc and applying two coats of heavy duty waterproofing coat (Dr Fixit Wounderproof-1 or equivalent) by mixing water @ 25-30% to make slurry coating and allow 4 to 6 hrs time for drying up of first coat before application of second coat in perpendicular direction of first coat and further left to dry for 4 hrs complete all as specified and directed as per manufacturer instructions.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface even and even smooth without using extra cement..
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper (oil emulsion), over a coat of alkali resistant primer on walls complete.
M&L for preparation of new or previously untreated wall surfaces and applying two coats of exterior emulsion paint all as specified and directed by EIC
M & L for preparation of old distempered surfaces of walls including washing, rubbing down and stopping nail holes etc and applying one coat of oil bound distemper (oil emulsion), white or tinted on walls complete all as specified.
Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces,as per manufacturers instructions complete all as directed and specified.
Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provided complete all as specified and as directed.
M&L filling PCC type E2 1:5:10 (40 mm graded stone aggr) as in sunken floor after applying appropriate treatment to side walls complete.
M&L 15mm thick rendering in cement plaster 1:3 with WPC on vertical sides of sunken floor incl finished even and smooth w/o using extra cement all as specified.
M & L for 25 mm thick PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate) with WPC on both sides of sunken floor.
M&L Complete preparation of efforescence or wetted internal wall surface using wirebrush to remove all the loose laittence & wash with clean water and applying crack filling as directed on site wet the wall prior to over coating brush apply I primer coat of Dr Fixit primeseal & allow to dry for 4 hours,apply damp proof coating Dr fixit damp guard,blend a mixture of Dr fixit & water in the ratio 1:1:1 (Base:harder:water) & brush apply 2 coat over the plastered surface in a span of 4 hours, over coat of walls with the suitable protective (decorative) coating complete all as specified and directed. Make: Dr fixit or techno commercial eq make as directed by Engineer-in-charge
M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6
M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:3).
M&L Granite (of any type) (20mm thick) work (table rubbed and polished) in steps, jambs, pillars and like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, incl 20 mm thick screed bed in CM 1:6 all as spceified and directed by Engr-in-charge.
M & L for cutting / moulding to granite (single or double ) slab incl rounded off edges for 20mm thick slabs griding and polishing complete.
Supplying and laying of 20 mm dia.(outer dia.) CPVC pipes SDR 11 with plain CPVC SDR 11 fittings jointed with CPVC adesive taflon tape complete to walls/ceiling or laying in floors including all connected brass CPVC fitting and cutting grooves, filled with CM 1:6 complete all as specified.
Supplying and laying of 25 mm dia.(outer dia.) CPVC pipes SDR 11 with plain CPVC SDR 11 fittings jointed with sealant solvent leak proof on walls/ceiling or laying in floors including all connected brass CPVC fitting and cutting grooves, filled with CM 1:6 complete all as specified.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe).
Supply and fix inrepair Health faucet with flexible pipe (ABS body) with 01 meter long PVC tube & wall hook complete all as specified and as directed.
S & F in repairs vitreous china squatting pan long pan of size 580mm, white, with integral foot rest (excluding flushing cistern and flush pipe)including provn of cement concrete connection to trap and to flush pipe, anti-syphonic pipe etc. complete including making good to floor
M&L in repair PVC low level flushing cistern valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in Repairs vitreous china Wash basin ovel type, decorative pattern and necessary fittings complete all as specified and directed.
S & F vitreous china wash hand basin, white, flat back, size 550x400mm, excluding taps, waste, chain and plug and porcelain, stopper but including brackets complete .
S&F15 mm dia brass chromium plated pillar tap, swan neck fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut, capstan head, screwed for 15mm dia pipe all as directed.
S&F Vitreous China urinals, bowl type (back or corner wall type), Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe Inclduing to wast pipe.
S&F bib taps cast copper alloy chromium plated, fancy type, long body, concealed type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed 15mm bore fixed in repairs all as specified and as directed.
S&F in repairs angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions.
S&F soap dish ,fixed to plugs with chromium plated brass screw fixed in repair complete all as specified.
S&F 600 mm long PVC connection Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm suitable of 15 mm nominal bore GI pipe complete with brass chromium plated unions and rubber washers. The weight of brass coupling nuts shall not be less than 40 grams. The weight of PVC pipe shall not be less than 63grams ,fixed in repairs complete all as specified and directed.
S&F 75 mm dia PVC (SWR) Nahani trap plain with grating,with rubber ring joints, incl jointing fixed in repairs all as specified and directed.
S&F PVC(SWR) pipe single socketed in any length with rubber ring joints laid in trenches or fixed in wall / floors 75mm dia bore, fixed in repairsall as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipe single socketed in any length with rubber ring joints laid in trenches or fixed in wall / floors 110mm dia bore, fixed in repairs all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipe single socketed in any length with rubber ring joints laid in trenches or fixed in wall / floors as rain water pipes 110mm dia bore, fixed in repairs all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequalwith rubber rings joints fixed in repairs.
S & F PVC (SWR) bends 110mm dia bore any radius with access door with rubber rings joints fixed in repairs. all as specified and directed.
S & F PVC (SWR) bends 75mm dia bore any radius with access door with rubber rings joints fixed in repairs. all as specified and directed.
S&F 75 mm dia PVC(SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
S & F Grating doom 100mm dia of PTMT(Minimum weight 25gms) fixed in repairs all as specified and directed.
S & F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) fixed in repairs all as specified and directed.
M&L 32mm dia waste fittings for pipe, brass chromium plated for glazed ware sinks, basins, etc and fly-nuts, flange end bedded in red lead cement and other end fixed in repairs all as specified and directed.
S&F in repairs 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc all as specified and directed.
S &F rotational moulded polyethylene water storage tank of 1000L capacity (cylindrical / vertical with closed top) complete hoisted and fixed in position, with lid, tounge nipple for inlet, outlet connections etc. , overflow complete all as specified in section 18 of SSR Part I 1991 including fly nut complete tounge nipple for inlet, outlet connections etc. fixed in repairs, complete all as directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out in any type of soil incld demolition of pipe & haunching complete all as specified and directed.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exc. 25 cm depth as in any type of soil complete all as specified and directed by Engr-In-Charge.
Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point.
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 150mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engr-In-Charge. NOTE :- Pipe shall be measured and paid separately).as in repairs.
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 200mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engr-In-Charge. NOTE :- Pipe shall be measured and paid separately).as in repairs.
S&F DWCPE (SN8) pipes, nominal dia 150 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge (ISI MArked)
S&F DWCPE (SN8) pipes, nominal dia 200 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge (ISI Marked)
Demolition of (reinforced) cement concrete of any description and in any position not otherwise specifically provided for.
M & L for RCC 1:2:4 type B-1(using 20mm graded stone aggregate), as in cover/platform, slabs incld necessary form work ect for manholes cover /platform, RCC benches set in CM:1:4 (reinforcement measured sperately)
Stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, incl fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc).
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed.
Taking down existing three/ single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked including sunk in anodized pressed steel box 1.60 mm thick, 60 mm deep for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
Description all as per item No 90 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed.
S & F for switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed.
S & F for socket outlet 2-in-1, 5 pin, 5 amp, 230 Volts complete all as specified and directed.
S & F for socket outlet 2-in-1, 5 pin, 5/15 amp, 230 Volts complete all as specified and directed.
S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
S & F for stepped type electronic fan regulator flushType complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 6 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB TPN rated capacity 63 to 100 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Labour only for refixing the celing fan obtained from item No 88 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp LED lamp with warranty option of 5 years from date of installation including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and warranty option of 5 years from date of installation and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
Supply, installation, testing & commissioning of Single Phase, 2 Wire, smart Pre-paid Energy Meters, BIS 16444 with celluar communication having current range 10- 60 Amp, 240 V, accuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, (GPRS Type) containing provision for TOD & RTC. Make L&T, HPL, Schneider, Secure (i) Meter Should support the following data: 15/ 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand (ii) Meter should have connect / disconnect functionality operable from prepaid billing software (iii) The meter should support open communication protocol DLMS with the software. Note:- (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty. (d) The meter cost would include two years recurring sim charges
Supply and "Commissioning and testing of configuration of multi user web based software with following modules :-(i) Meter Data Management Module:- The meter data management module would be responsible for collecting the data concentrator and make the data available to the billing module. The system would support manual meter data entry if required. The meter data management system would capture and provide the following:- (a) 15/30 min instantaneous data for cum energy (meter reading), current, voltage, power, power factor, frequency etc (b) Monthly billing survey data for cum energy and max demand (ii) Billing Module:- The billing module would collect the data from the meter management module, calculate billing determinate and make energy data/ billing data available to admin and end users. (iii) Occupation and Vacation Module :- The system would support occupation / vacation based on the unit categories. The system would support data capture on occupation and vacation events. (iv) Customer Portal :- The system would include a customer portal for the resident / occupant to log in and view their own energy / billing data. (v) Energy Accounting Module:- The system would include features of energy accounting the system would be able to account for total energy. (vi) Happy hour definition:- the software would support happy hour definition including days and hours (vii) Tariff Setup: - The software would support flexible tariff setup including water and license fee if required. (viii) Alert:- The software would support payment, low balance, disconnection , connections alerts on email, sms and app notifications. Note:- (a) The software would be hosted on MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud) (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc.
Labour only for refixing the prepaid meter (AMR) obtained from item No 89 above with necessary incomming & out going connections complete all as specified and as directed.
OUTGOING (a) 4 pole MCCB 100 Amps with rotary handle, thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 18 KA including all fixing accessories with both ends spreader links - 01 No. (b) 4 pole MCCB 63 Amps with rotary handle, thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 18 KA including rotary handle and all fixing accessories with both ends spreader links - 03 Nos. (c) Fixing only serviceable existing 3 phase prepaid meter- 01 No (obtained from item No 5)
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI earth strip 32x6 mm thick protected by 40mm GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, GI earth strip 32x6 mm thick and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 40 mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc incl taking down old earthing . complete all as specified and directed by Engineer-in-Charge. Note :- GI earth strip and protection pipe of same size upto 7.5m shall deemed to be included into quoted rate
SURAJ ENTERPRISE
badri glass and construction
jitendra c joisar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .