| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹18.0 L+₹84,318.70 (4.92%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹19.0 L+₹1.9 L (10.9%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Not lowest |
Tender Value
₹17.4 L
EMD Value
₹34,800
Closing Date
29 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF AMBALA
HQ CWE (AF) Ambala Ambala Cantt-133001
PROVN OF STORAGE ACCN FOR CWE (AF) AMBALA OFFICE UNDER GE (AF) AMBALA
2023_MES_586003_1
CWE/AF AMB/AMB-47/2022-23
Open Tender
Construction Works
Item Rate
120 days
Ambala cantt
For MES enlisted contractor Class E Category a i and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹34,800
Yes
16 Aug 2023
16 Mar 2023
31 May 2023
16 Mar 2023
29 May 2023
15 May 2023
16 Mar 2023 - 26 Mar 2023
Amount
Surface excavation not exceeding 30cm deep & averaging 15cm deep in soft/losse soil complete all as specified & directed.
Excavation in over areas, not exceeding 1.5mtr deep for foundation etc. and getting out, in soft/loose soil complete all as specified & directed.
M&L PCC 1:3:6, type C2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
M&L Pre-constructional anti termite treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & directed. Note:- For Guarantee & Security deposit refer Particulars specification.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr span complete all as specified & directed.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified & directed.
M&L mild steel TMT bars 10mm dia and over, Fe500/Fe500D grade confirming to IS-1786, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L mild steel TMT bars 6mm dia and over upto & inculding 10mm dia, Fe500/Fe500D grade confirming to IS-1786, cut to length cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacer & binders complete all as specified & directed.
M&L brick work with flyash burnt bricks (IS-13757), old size, Designation 75, straight or curved on plan exceeding 6mtr mean radius, built in cement mortar 1:6 complete all as specified & directed.
M&L brick work with flyash burnt bricks (IS-13757), old size, Designation 75, straight or curved on plan to any radius, built in half brick thick wall in cement mortar 1:4 complete all as specified & directed.
M&L rendering 15 mm thick in cement mortar 1:4, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces as in wall complete all as specified & directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick or concrete surfaces as in wall complete all as specified & directed.
M&L rendering 5 mm thick in cement mortar 1:3, finished even and smooth without using extra cement on fair faces of concrete surfaces as in ceiling/soffits complete all as specified & directed.
M&L preparation of newly plastered surfaces of ceiling/soffits and applying three coat of white wash complete all as specified & directed.
M&L preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified & directed.
M&L preparation of newly plastered surfaces of wall and applying applying two coat of cement base paint of approved shade/tint over & including one coat of alkali resistant primer complete all as specified & directed.
M&L 40mm thick plain cement concrete(PCC) 1:2:4, type B-1, using 20mm graded mechanically crushed stone aggregate as in flooring finished even & fair complete all as specified & directed.
S&F glass dividing strips 3mm thick & 38mm wide complete all as specified & directed.
S&F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W(Gde-E-250) Quality 'A' complete all as specified & directed
S&F 30mm thick flush shutter, solid core construction with block board core and plywood face panels commercial type on both side complete all as specified & directed.
S&F factory made Box type steel window, double shutter, glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including provision of mild steel guard bars complete all as specified & directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. (ii) Glazing, Wire cloth & MS guard bars shall be measured and paid separately . (iii) Painting to window shall be measured and paid separately however one shop coat primer included in quoted rates. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit. (v)Steel window shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specifed & directed. Notes: - (i) Glazing/Wire cloth shall be measured and paid separately . (ii) Painting to window shall be measured and paid separately however one shop coat primer included in quoted rates. (iii)Steel ventilator shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F mild steel work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed
S&F 100 mm size, MS butt hinges, medium weight, cold rolled, fixed complete all as specified & directed
S&F 150mm long, aluminium, anodized, barrel tower bolt of extruded section complete all as specified & directed
S&F 125 mm size Aluminium handle, cast type, anodized fixed complete all as specified & directed
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed.
S&F sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified & directed.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staples complete all as specified & directed.
M&L Atactic Polypropylene (APP) polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster matt (Weight not less than 150 gram per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 litre per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP complete all as specified & directed . Notes : (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) Security deposit as a guarantee against Water proofing treatment shall be retained in final bill and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. (iii) The amount of security deposit shall be calculated as per the scales laid down for calculating Earnest Money Deposit enhanced by 25% on the total amount of Water proofing treatment work. The contractor's quoted rates for these items shall deemed to be inclusive of this aspect.
M&L rendering 10mm thick in cement mortar 1:3, surface finished even & fair mixed with water proofing compound over green concrete on roof slab complete all as specified & directed. Note: Water proofing compound shall be measured & paid separetely.
M&L preparation of wood and wood based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of pink primer complete all as specified & directed.
M&L preparation of new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified & directed.
M&L 100mm thick PCC 1:4:8, type D2, using 40mm graded mechanically crushed stone aggregate as in sub bases of floors complete all as specified & directed.
M&L 75mm thick PCC 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified & directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length. (ii) 30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick each in any type of soil complete all as specified & directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
Supply only integral water proofing compound (WPC) complete all as specified & directed.
M&L Hardcore of broken stone or boulders of gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified & directed.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 20mm bore(having 2mm wall thickness), medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 2.8mm/3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 1.5 sqmm connected to common earth and earth dolly for one light point/ceiling fan point controlled by one way switch 5/6 amp complete all as specified & directed.
Description all as per BOQ item No. 47.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the independent board.
Description all as per BOQ item No. 47.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the same board.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 2.5sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 25mm bore(having 2mm wall thickness), medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 2.8mm/3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 2.5sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one way switch on the independent board complete all as specified & directed. Notes for BOQ item No. 47.00 to 50.00 :- Rate quoted shall be inclusive of cutting chases in wall and making good in cement mortar 1:3 & finishing the disturbed surfaces to match with the existing surfaces.
S&F switch piano, flush type, 5/6 amp, single pole, one way complete all as specified & directed.
S&F switch piano, flush type, 15/16 amp, single pole, one way complete all as specified & directed.
S&F socket outlet, flush type, 2 in 1, 3 pin, 5/6 amp, complete all as specified & directed.
S&F socket outlet, flush type, 2 in 1, 3 pin, 5/6 & 15/16 amp, complete all as specified & directed.
S&F ceiling rose, surface bakelite 3 terminals, isolated body complete all as specified & directed.
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable,1100 volts grade, 4.0sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 4.0sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified & directed. Note :- Two runs of 4.0sqmm cable alongwith one run of 4.0sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
S&F LED lights fitting 1x16 watt, 220volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
S&F 1x18 watt wall mounted, new generation LED T-8 retro fit for multipuspose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed.
S&F LED street light fitting 45 Watts, input 110 volts, provision of auto shut down on high voltages, life>50000 Hrs, operating temp 1 degree centigrade to 50 degree centigrade, as per IP 65, luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45 W=10% W & rate lumens of min 4500 lumens with 120 degree view angle, the driver must be constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 including bracket made out of 25mm bore GI pipe light grade of length not less than 1.2 mtr bent to shape & suitable size of clamps, nuts, bolts, washer, fastner etc. complete all as directed & specified.
S&F ceiling fans complete with blades, down rods and accessories, 230 volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated, without remote including step type electronic regulator, brushless direct current motor (BLDC), hanging & connecting with existing point complete all as specified & directed.
S&F sheet metal enclosure for vertical TPN distribution board with provision of mounting MCCB upto 120 Amp, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified & directed.
S&F sheet metal enclosure for MCB DBs, 230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 8 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified & directed.
S&F MCCB 4 pole 100 Amps, 16KA with fixed thermal magnetic setting complete all as specified & directed.
S&F MCB, single pole & neutral, 40 Amp, C curve, 10 kA capacity, 240 volts complete all as specified & directed.
S&F MCB, single pole, 5 to 32 Amp, C curve, 10 kA capacity, 240 volts complete all as specified & directed.
Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose soil complete all as specified & directed.
M&L river washed fine as in sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed.
Supply and laying old size, common burnt clay, sub class 'B' bricks, designation 75, laid flat & dry for protection of electric cable in trenches, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
Supply, laying, jointing, testing and commissioning of LT electric cable, 1100 Volts grade, heavy duty, XLPE insulated, armoured electric power cable with aluminium conductor of cross sectional area 10sqmm, 4 core conforming to IS- 7098 (Part I) 1988 laid as in trenches or fixed along the wall/pole or passing through pipes/ducts etc, complete all as specified & directed.
M/S SHASTRI BUILDERS AND ENGINEERS
KULWANT SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .