Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.8 L+₹3.9 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹43.4 L+₹7.5 L (21.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹44.4 L+₹8.5 L (23.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Aug 2023, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
Repair and maintenance of DG Sets, AMF Panels, Fire Fighting and Fire Alarm System, LT ACB, ATS, APFC Panels and Servo Stabilizers at INS Valsura, Jamnagar
2023_MES_606389_1
8688/VAL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
336 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (I) Navy Jamnagar
₹90,000
Yes
15 Sept 2023
28 Jun 2023
16 Aug 2023
28 Jun 2023
14 Aug 2023
27 Jul 2023
Amount
M&L for attending 'B' check of DG set of capacity 63 kVA (Make : Greaves) at different locations to carry out maintenance/servicing as given below once during the contract period as ordered including testing on completion of the following complete all as directed:- (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc. (ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel leakage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/ silencer, Repair if required. (vi) Check electrical connections of engine. The wiring shall be maintained properly and engine starting system from engine instrument panel shall be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging Repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning. (xii) Change of Air filter element with ‘O’ ring. (xiii) Change of filter insert with ‘O’ ring (xiv) Change of Lubricating oil filter. (xv) Change of Primary filter element. (xvi) Change of secondary filter element. (xvii) Change of greaves Lub oil CI4- 10 ltrs pack (xviii) Change of Radiator pre-mix greaves KOOL 10 ltrs, complete to the satisfaction of Engineer -in-charge. Notes :- (i) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras required for replacement to make the DG set fully functional. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (ii) All T&P shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
All as per serial item No. 1 here-in-above, but DG set of capacity 100 kVA Make: Greaves
All as per serial item No. 1 here-in-above, but twice during the contract period and change of greaves Lub oil CI4- 20 Ltrs pack complete for DG set of capacity 160 kVA Make: Greaves
All as per serial item No. 1 here-in-above, but twice during the contract period and change of greaves Lub oil CI4- 20 Ltrs pack complete for DG set of capacity 250 kVA Make: Greaves
All as per serial item No. 1 here-in-above, but twice during the contract period and change of Cummins Lub oil CI4- 20 Ltrs pack complete for DG set of capacity 160 kVA Make: Jakson
M&L for attending 'B' check for DG set of capacity 15 kVA (Make: Kirloskar) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following complete all as directed :- (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc.(ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel leakage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/ silencer, repair if required. (vi) Check electrical connections of engine. The wiring shall be maintained properly and engine starting system from engine instrument panel shall be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging, repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning (xii) Change of Spinon Lub oil filter (xiii) Change of air cleaner element (xiv) change of Belt- AVX 10 1500 (xv) Change of fuel filter element (xvi) Change of KOEL care premium genuine oil 7.5 Ltrs Can, complete all as specified and directed by Engineer-in-charge. Notes :- (i) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras required for replacement to make the DG set fully functional. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (ii) All T&P shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
All as per serial item No. 6 here-in-above, but change of V Belt cogged- AVX10 1265L blower pulley, Change of V Belt cogged-AVX10 1136 for alternator pulley and Change of KOEL care premium genuine oil 13 Ltrs Can, complete for DG set of capacity 40 kVA Make: Kirloskar
M&L for attending 'C' check of DG set of capacity 63 kVA (Make : Greaves) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following complete all as directed: (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc. (ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel leakage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/silencer, repair if required. (vi) Check electrical connections of engine. The wiring shall be maintained properly and engine starting system from engine instrument panel shall be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging, repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning (xii) Change of Gasket set 4G11TA (w/o Head gasket) (xiii) Change of cogged belt AX43-1143L (xiv) change of pipe turbo oil supply (xv) Change of pipe turbo drain (xvi) Change of set of hoses for 4G valve (xvii) Change of setting screw (xviii) Change of hex nut M8x1 DIN934 (xix) Change of gasket for PDC rocker cover (xx) Change of set of flex F/P (xxi) Change of push rod. Notes :- (i) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras required for replacement to make the DG set fully functional. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (ii) All T&P shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
All as per serial item No. 8 here-in-above, but DG set of capacity 100 kVA Make: Greaves
M&L for attending 'C' check of DG set of capacity 15 kVA (Make: Kirloskar) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following complete all as directed: (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc. (ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel leakage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/silencer, repair if required. (vi) Check electrical connections of engine .The wiring shall be maintained properly and engine starting system from engine instrument panel shall be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging, repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning. (xii) Change of rocker cover gasket. (xiii) Change of valve seat insert inlet & exhaust. (xiv) Change of valve pair inlet & exhaust. (xv) Change of set of joints. (xvi) Change of set of ‘O’ rings HA294. (xvii) Change of intermediate ring 1.1mm. (xviii) Change of valve guide. (xix) Change of valve stem seal, complete all as specified and directed by Engineer -in-charge. Notes :- (i) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras required for replacement to make the DG set fully functional. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (ii) All T&P shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
All as per serial item No. 10 here-in-above, but for DG set of capacity 40 kVA Make: Kirloskar
S&F in repairs set of hoses with clips for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs set of fuel pipes for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs set of injector pipes for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs Exhaust silencer for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs injector with nozzle for DG set of capacity 63/ 100 kVA Make: Greaves
M&L for greaves lubricating oil SAE 15W40 suitable for DG Set.
M&L for Coolant suitable for DG sets make Fleetguard, Valvoline, Premium
S&F in repairs Air filter outer for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs Air filter inner for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs 12V temperature gauge (40-120 deg cel) for DG set of capacity 63/ 100 kVA Make: Greaves
S&F in repairs 12V pressure gauge, 0-10 bar for DG set of capacity 63/ 100 kVA Make: Greaves
Servicing and calibration of FIP (Fuel injection pump) & nozzles including replacement of minor parts like nuts, bolts, washers, etc of DG Set 63/100 KVA capacity.
M&L for taking out Radiator of DG set 63 kVA/100 kVA Make: Greaves for repair, welding, brazing, leak testing & refixing to DG set to its original position and testing complete all as directed.
M&L for taking out Radiator of DG set 160 kVA/250 kVA Make: Greaves for repair, welding, brazing, leak testing & refixing to DG set to its original position and testing complete all as directed.
M&L for taking out Radiator of DG set 160 kVA Make: Jakson for repair, welding, brazing, leak testing & refixing to DG set to its original position and testing complete all as directed.
Servicing & repair to self starter of DG set of capacity 15/40 kVA (Make: Kirloskar) including replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete.
All as per serial item No. 27 here-in-above, but for DG set of capacity 63/100 kVA Make: Greaves
All as per serial item No. 27 here-in-above, but for DG set of capacity 160/250 kVA Make: Greaves
All as per serial item No. 27 here-in-above, but for DG set of capacity 160 kVA Make: Jakson
S&F in repair Solenoid Switch for 15/ 40 kVA DG set Make: Kirlosakar and testing complete for proper functioning.
S&F in repair Solenoid Switch for 63/ 100 kVA DG set Make: Greaves and testing complete for proper functioning.
S&F in repair Relay card for 15/ 40 kVA DG set Make: Kirlosakar and testing complete for proper functioning.
S&F in repair Relay card for 63/ 100 kVA DG set Make: Greaves and testing complete for proper functioning.
S&F in repair Solenoid Switch for 160/250 kVA DG set Make: Greaves and testing complete for proper functioning.
S&F in repair AVR suitable for 15 kVA DG Set complete all as directed.
S&F in repair AVR suitable for 40 KVA DG Set complete all as directed.
S&F in repair AVR suitable for 63 KVA DG Set complete all as directed.
S&F in repair AVR suitable for 100 KVA DG Set complete all as directed.
S&F in repair AVR suitable for 160 KVA DG Set complete all as directed.
S&F in repair AVR suitable for 250 KVA DG Set complete all as directed.
S&F in repair battery auto cable copper PVC insulated unsheathed 35 Sqmm single core copper cable complete.
S&F in repair battery auto cable copper PVC insulated unsheathed 95 sqmm single core copper cable complete.
S&F 90AH 12Volt Lead acid battery (Maintenance free battery with minimum 2 years manufacturer’s warranty) for DG set. Make: Exide Xpress or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F 150AH 12Volt Lead acid battery (Maintenance free battery with minimum 2 years manufacturer’s warranty) for DG set. Make: Exide Gold or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F copper battery lugs for DG set battery complete all as directed.
S&F in repair Ignition Switch of DG Sets complete all as directed.
S&F in repair No volt coil for contactor of capacity up to 200 Amp Capacity all as specified and as directed. Make : L&T /C&S/Schneider or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair LED type pilot lamp. Make: C&S / L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Volt meter 0-500 Volt in existing panel including wiring from bus bar to volt meter terminals and fix the wiring with existing control wiring all as directed. Make: L&T/ Meco/ HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Ammeter 0-100 Amp in existing panel with necessary wiring from CT to Ammeter and fix the wiring in existing set of control wiring all as directed. Make: L&T/ Meco/ HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Ammeter 0-200 Amp in existing panel with necessary wiring from CT to Ammeter and fix the wiring in existing set of control wiring all as directed. Make: L&T/ Meco/ HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair electronic timer of 215/240/360/415 Volt 3 to 120 Sec all as directed. Make: L&T/C&S/Schneider or equivalent in makes mentioned in Appendix 'B' here-in-after.
M&L for wiring loom of control panel of DG Set AMF panel from Relay and auxiliary contacts complete by using 2.5 sq.mm copper cable of colour code from auxiliary contacts to Relay including fault finding etc complete all as specified and as directed.
M&L for Overhauling of water pump with repairing kit for 63/100 kVA DG set complete all as directed.
M&L for Overhauling of water pump with repairing kit for 160/250 kVA DG set complete all as directed.
M&L for complete checking of AMF panel, finding the fault, servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations all as directed. Note: Supply only of new items required for replacement shall be measured & paid for separately under respective items of this Schedule.
Supply only AMF Relay.
Supply only single phase preventer.
Supply only PLA relay.
Supply only 3 pole power Contactor 70 A, 415 V. Make: L&T ‘ML-4’ or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply only 3 pole power Contactor 163 A, 415 V. Make: L&T ‘ML-4’ or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair HRC Fuse base of capacity 200 Amps.
S&F in repair Anti vibration pad set suitable for 63/ 100kVA DG set all as directed.
M&L for taking out alternator of DG set of capacity 15 kVA (Make: Kirloskar) by dismantling from engine pulley including disconnecting electrical connection complete & transporting to workshop. Opening the rotor and stator for rewinding with copper wire of existing guage and then varnishing the stator & rotor with good quality varnish, Heating and baking complete upto requisite duration. Check bearing & shaft for machining if required. Re-assemble stator & rotor by replacing existing bearings with new bearings complete. Back transportation alternator to base and coupled with engine by using new rubber bushing spider, nut bolts complete. Testing the system for smooth functioning & checking current and load output by giving existing electrical load to the entire satisfaction of Engineer-in-charge.
All as per serial item No. 66 here-in-above, but for DG set of capacity 40 kVA Make: Kirloskar
All as per serial item No. 66 here-in-above, but for DG set of capacity 63 kVA Make: Greaves
All as per serial item No. 66 here-in-above, but for DG set of capacity 100 kVA Make: Greaves
M&L for Readymade electrolyte having specific gravity 1.4 for DG set of any capacity all as directed.
M&L for Distilled water having specific gravity 1.0 for DG set of any capacity all as directed.
S&F in repair AMF Panel outdoor type double door factory fabricated 3mm thick CRCA sheet front opening with Aluminium bus bar switch gear and all requisite internal fittings/ fixtures suitable for 63 kVA DG Set, 3 Phase, 50 Hz, 1500 RPM of Make Greaves (Engine sl No. 12080480408, alternator Sl No. 08L33889) complete all as specified and as directed.
S&F in repair MCCB with thermal magnetic protection unit rating 160 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4200 57 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 100 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4200 55 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Servicing, repair, maintenance and attending complaint/ faults to the Fire Fighting and Fire alarm system including Fire Alarm Control Panel, Pre Alarm Action, Programmable detector sensitivity, Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 Characters LCD display 2 numbers of loop card and 200 devices in any combination per loop. Day/ Night Mode facility, USB 2.0 interface for PC connectivity RS 485 Communication facility for network/ Repeater/ MODBUS/ BAC net. Programmable Auto Silence Facility, Programmable AC Loos delay. Programmable Silence Inhibit. Two Nos. of programmable inputs, Battery low audio, visual warning, Three programmable Form C relay for Fire, Fault and Supervisory maintenance complete all as directed. Note : New spare parts shall be measured and paid for separately.
Supply, installation, commissioning and testing of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 2000 Event Storage with Real Time Clock, Upto 192 grouping facility, Pre Alarm Action, Programmable detector sensitivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test. 40 X 4 Characters LCD display 2 numbers of loop card and 200 devices in any combination per loop. Day / Night Mode facility. USB 2.0 Interface for PC connectivity. RS 485 Communication facility for Network / Repeater / MODBUS / BACnet. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two Nos of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220VAC + 10% -15%, 60 / 50 Hz. Standby Power 24V DC (2 Nos of 12V, 40 Ah (Max), Built in for 12Ah) Sealed Lead acid battery Operating Condition Operating Temperature 0 - 49°C / 32-120°F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ± 2°C / 90 ± 3°F including taking down old unserviceable Panel complete all as specified and as directed.
Supply, commissioning and testing of Smoke detector Operating Voltage Range: 9 to 32 VDC Volts Non-polarized Standby Current: ≤100µA @ 24 VDC, Maximum Alarm Current (LED on) : ≤55mA @ 24 VDC, Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing, Operating Temperature Range: 14°F to 120°F (-10°C to 49°C), Adjustable Sensitivity: 1-2.5%/FT, Height: 2.2 (55 mm) installed in Base including taking down old unserviceable smoke detector complete all as specified and as directed. Make: Ravel Electronics Pvt Ltd/ Honey well / Agni/ Ceasfire/ Safex/ Flame Gurad Industries/ Nitin or equivalent make as approved by GE.
S&F in repair of Battery DC, 12V, 7 AH, lead acid duly initial charged complete all as specified and as directed. Make: Exide / Star Gold or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply, commissioning and testing of Fire Alarm Hooter made out of iron, red colour operating voltage 24 DC supply Dimensions (L x B x H) : 18.5 cm x 13 cm x 7.5 cm including taking down existing fire alarm hooter complete all as specified and directed. Make: Ravel Electronics Pvt Ltd/ Honey well / Agni/ Ceasfire/ Safex/ Flame Gurad Industries/ Nitin or equivalent make as approved by GE.
Supply, commissioning and testing of Addressable manual call point resettable type including taking down existing addressable manual call point complete all as specified and as directed. Make: Ravel Electronics Pvt Ltd/ Honey well / Agni/ Ceasfire/ Safex/ Flame Gurad Industries/ Nitin or equivalent make as approved by GE.
S&F in repair Hydrant valve single headed Gun metal landing valve (internal/external Fire-Hydrants) with oblique type single outlet complete with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain conforming to IS 5290 complete all as specified and as directed.
S&F in repair Flanged stand post CI of 80 mm dia 1.5 m height complete all as specified and as directed.
M&L for maintenance of Automatic Transfer Switch (ATS) of rating up to 630 Amp of Make Havells/ Legrand/ L&T complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and disconnecting incoming and outgoing connections, refixing the same after complete maintenance, replacement of fuses, tripping mechanism, tripping coils, pole assembly, control unit, auxiliary switch, incoming and outgoing connections and replacement of overheated/ faulty portion of control circuit wiring as per above mentioned make as and when as directed by Engineer-in-Charge. Notes : (i) Necessary spare parts required replacement shall be replaced only after prior inspection & approval of Engineer-in-Charge. (ii) Spares required for repairing/ servicing of ATS shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule 'A' (BoQ). (iii) Fixing rate of the spares including testing is deemed to be inclusive in quoted rate of this item. (iv) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
Supply only Closing Coil for ATS upto 630 Amp, 4 pole as per existing make.
Supply only Control unit for ATS upto 630 Amp, 4 pole, as per existing make.
Supply only Trip coil of assy for ATS of rating upto 630 Amp as per existing make.
Supply only Auxiliary switch for ATS of rating upto 630 Amp as per existing make.
Supply only Pole assembly for ATS of rating upto 200 Amp as per existing make.
Supply only Pole assembly for ATS of rating 315 Amp as per existing make.
Supply only Pole assembly for ATS of rating 400 Amp as per existing make.
Supply only Pole assembly for ATS of rating 630 Amp as per existing make.
M&L for servicing and repair to HT oil switch of size upto 630 Amp complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and opening the Oil chamber of HT switch gear and cleaning the contacts, put the fuse in position and testing complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs HT HRC type fuse, rating 40/63 Amp of HT Oil Switch complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and opening the Oil chamber of HT switch gear and cleaning the contacts put the fuse in position and testing complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ Bussmann/ CG Lucy or equivalent as approved by GE.
M&L for servicing of LT ACB of rating up to 630 Amp, 415 Volt, 50 Hz of any make complete by taking the shut down with prior intimation & permission of Engineer-in-Charge and cleaning the ACB by using air blower, tightening of connection of control circuit and complete checking of all fuses and control circuit for smooth functioning by employing one skilled tradesman as and when required including consisting of following :- (a) Checking the control circuit wiring and rectifying the same with new rewiring with proper size and colour code where required at site. (b) Checking the components for replacement such as Shunt release, UV release, ammeter, voltmeter, etc. c) Resetting and testing of relay setting for proper functioning.
S&F in repair copper bus bar of rating as per required at site, with supporting insulator duly fitted in PVC insulated sleeve in existing panel with requisite in shape and size required at site for fixing the bus bar at existing panel complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1100 Volt grade flexible single core cable with tinned copper stranded conductor PVC insulated and sheathed of cross sectional area 240 Sqmm (ISI marked) including copper lugs at both ends and all accessories required as per the site requirement including testing on completion complete all as specified and as directed.
All as per serial item No. 96 here-in-above, but cross-sectional area 185 Sqmm.
All as per serial item No. 96 here-in-above, but cross-sectional area 16 Sqmm.
All as per serial item No. 96, here-in-above, but cross-sectional area 10 Sqmm.
All as per serial item No. 96 here-in-above, but cross-sectional area 2.5 Sqmm.
M&L for CTs of required ratio from 100/5 to 800/5 in replacement in existing feeder pillar box and connect terminals to APFC panel and testing on completion complete all as specified & as directed.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C5 with auxiliary contacts for upto 5 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C12.5 with auxiliary contacts for upto 12.5 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C15 with auxiliary contacts for upto 15 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Capacitor duty contactors, 3 pole, 230/415 V, 50 Hz of type MO C25 with auxiliary contacts for upto 25 kVAR rating complete all as specified & as directed. Make : L&T/C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair 6-stage APFC relay with built in P.F Meter complete all as directed. Make : L&T/C&S/HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair 8-stage APFC relay with built in P.F Meter complete all as directed. Make : L&T/C&S/HPL or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
S&F in repairs MCB TPN 20 to 32 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve, with proper size lugs complete all as directed.
S&F in repairs MCB TPN 40 to 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as directed.
S&F in repair Power factor improvement Capacitor banks, Cylindrical type, 3 phase, 440 V, Heavy duty of as per required at site from 5 to 25 kVAR LTCCR super heavy duty type capacitor complete all as directed. Make : L&T / EPCOS/ C&S or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair R/Y/B phase Indicator lamps LED type complete all as directed.
S&F in repair 3 Pole Power Contactor, 40 Amp AC3 rating, 2 NO + 2 NC, including necessary connections for incoming and outgoing complete all as directed. Make : L&T ‘Type ML 3’ Cat No. SS90721 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Disconnecting/ Taking out the existing Servo stabilizer transformer from site for repairing and transporting to workshop for servicing and repairing, including loading, unloading and handling to carry out repairs and refixing the same after repairing, installation, testing and commissioning at its original/ new location as ordered, decanting the transformer oil and checking of all parts for repair/ replacement of parts of 100 to 300 kVA capacity of servo controlled stabilizers 440 V, 3 Phase, AC 50 Hz, complete all as directed by Engineer-in-Charge. Notes : (i) Necessary spare parts required replacement shall be replaced only after prior inspection & approval of Engineer-in-Charge. (ii) Spares required for repairing/ servicing of Servo stabilizer transformer shall be measured and paid for separately under relevant items of this Schedule 'A' (BoQ). (iii) Fixing rate of the spares including testing is deemed to be inclusive in quoted rate of this item. (iv) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
All as per serial item No. 115 here-in-above, but Servo stabilizer transformer of capacity 15 to 30 kVA.
Supply only Control push buttons/ switches/ fuse carriers/ knobs etc for Servo stabilizers transformer.
Rewinding of coils all as per its original specifications by new copper conductor and with necessary insulation materials for Servo stabilizers transformer.
Supply only LT bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for Servo stabilizers transformer.
Supply only new Transformer oil up to conservator level marking as per IS-335 having dielectric strength not less than 40 kV at 2.5mm gap complete all as specified and as directed for Servo stabilizers transformer. Make : Electrol, Power Oil, Indian Oil, Savita or equivalent as approved by GE. Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor and empty barrel will be the property of the Department and same shall be deposited to the AGE E/M Store Yard. Nothing extra shall be paid on this account.
Supply only Servo control motor as per existing model for controlling the voltage for Servo stabilizers transformer.
Supply only Cork/ Neoprene rubber Gasket set complete for Servo stabilizers transformer.
Supply only PCB for Servo controlled voltage stabilizers as per existing model and make or equivalent model and make as approved by GE.
M&L for preparation of external surfaces of Servo stabilizer transformer of capacity upto 300 KVA including cleaning and removing oil spots from the body and painting with two coats of synthetic enamel paint (first quality) of approved tint with gun sprayer including marking of SM/MES No etc. on body with synthetic enamel paint (white) complete all as specified and as directed.
M&L for filtration / dehydration of old/existing transformer oil including topping up of transformer oil as required in the Servo stabilizer transformers of different capacity, installed at various locations with suitable capacity of filtration machine to achieve dielectric strength minimum 60 KV complete all as specified and as directed. Notes: (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) New Transformer Oil required for topping up shall be paid for separately under relevant item of this Schedule.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in repair MCCB with thermal magnetic protection unit rating 630 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4220 09 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 400 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4220 07 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 160 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair MCCB with thermal magnetic protection unit rating 250 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified. Make: Legrand Cat Part No. 4202 49 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 630 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO630 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 400 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO400 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Automatic Transfer Switch (ATS) 200 Amp, 4 Pole with controller, 415 V, 50 Hz, Open Execution, complete all as specified and as directed. Make: Havells Cat No. IHYFCDO200 or equivalent in L&T/ABB/other makes mentioned in Appendix 'B' here-in-after.
S&F in repair Multifunction meter of 96x96 mm size, flush mounting, complete with digital display, LED showing Voltage, current, PF, Frequency, electrical parameters complete all as specified and as directed. Make: L&T Cat No. WL411010OOOO or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 42Ah 12Volt Lead acid battery (Maintenance free battery with minimum 2 years manufacturer’s warranty) for 10/ 15 kVA UPS including necessary connections complete. Make : Exide Powersafe plus or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : Old battery shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repairs charging card for 15 kVA DSP based 3P-1Ph UPS. Make: APLAB or equivalent as approved by GE.
S&F in repairs DC driver card for 15 kVA DSP based 3P-1Ph UPS. Make: APLAB or equivalent as approved by GE.
S&F in repairs display card for 15 kVA DSP based 3P-1Ph UPS. Make: APLAB or equivalent as approved by GE.
S&F in repairs bypass card for 10 kVA DSP based 3P-1Ph UPS. Make: APLAB or equivalent as approved by GE.
S&F in repairs Transformer card for 10 kVA DSP based 3P-1Ph UPS. Make: APLAB or equivalent as approved by GE.
S&F in repair Air Circuit Breaker (ACB), 630 Amp, 4 Pole, 50 kA, drawout version, single frame, manual and electrical Versions, including advanced self powered electronic protection units and shunt coil, close coil, working on 220-250 V AC, Neutral Overload protection OFF-50%-100%, inbuilt temperature protection, LCD Display, Real terminals - vertical or horizontal connection with bars to be fixed onto plate-4P, fast operation type in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and including necessary addition/ alteration to existing panel with welding cutting to steel structure and providing new steel items and taking down old item complete all as specified and as directed. Make : Legrand ‘ACB : Cat No 6695 42’, ‘Electronic Protection Unit : Cat No 0281 67’ & ‘Real terminals : Cat No. 0288 97’ or equivalent in makes mentioned in Appendix 'B' here-in-after.
Jyoti Refrigeration
JAMNAGAR ELECTRIC AND MACHINERY CO
BHAVNA IMPERIAL ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .