Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.9 L+₹13,359.50 (0.36%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹37.2 L+₹37,199 (1.01%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹37.3 L+₹53,315 (1.45%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹39.3 L+₹2.5 L (6.74%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF LT CABLES, LT JOINTS AND CONNECTED WORKS AT AF STATION JAMNAGAR NO.1
2023_MES_605470_1
8243/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹90,000
Yes
19 Aug 2023
24 Jun 2023
24 Jul 2023
24 Jun 2023
22 Jul 2023
8 Jul 2023
Amount
Disconnecting & Taking out LT underground aluminium conductor of size 300 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 240 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 185 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 120 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 95 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 70 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 50 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 35 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 25 sqmm 4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 16 sqmm 4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 10 sqmm 4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Disconnecting & Taking out LT underground aluminium conductor of size 6 sqmm 4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed
Note for item No 01 to 12:- Excavation and earth work will be measured and paid seprately under respective items of this schedule
Laying only LT underground aluminium conductor of size 300 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 240 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 185 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 120 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 95 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 70 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 50 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 35 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 25 sqmm 4 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 16 sqmm 4 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 10 sqmm 4 core in trenches / wall / ducts, etc., complete all as specified and directed.
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 6 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed.
Note for item No 13 to 35:- (i) Excavation, Earthwork, sand cushioning, cable cover and joints (straight through/ termination) will be measured and paid seprately under respective items of this schedule.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and n exc 3.00m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard / dense soil.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / disintegrated rock.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and n exc 3.00m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material (soil) exc. 50m but n.exc 100 m and depositing where directed at a level n exc. 1.5 m above the starting point.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009). For measurement purpose thickness of sand after punning down will be considered.)
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
Laying only PCC cable cover for LT/HT UG cable, of any description retrieved from item No 1 to 12 & 63, all as specified and directed by Engr-in-Charge.
S&F in repairs Tubes, 'light grade', galvanised, mild steel of 40mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F in repairs Tubes, 'light grade', galvanised, mild steel of 50mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F in repairs Tubes, 'light grade', galvanised, mild steel of 80mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F in repairs Tubes, 'light grade', galvanised, mild steel of 100mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
Boring horizontally under roads/pavement/ hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including supply and fixing HDPE pipe of 90 mm dia(ISI Marked) suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. (Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost).
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2 to 4core, 16 to 25 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5core, 35 to 50 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70 to 95 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm all as specified and as directed.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 240 to 300 Sqmm all as specified and as directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable, two core 2.5 sq mm flat or circular, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable,two core 4 sq mm flat or circular, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable,two core 6 sq mm flat or circular, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable,two core 10 sq mm flat or circular, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works complete all as specified and directed.
M&L for heat shrinkable jointing kit outdoor type suitable for 11 KV, along with complette accessories suitable for XLPE armoured aluminium cable of 95/120 Sq mm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L for heat shrinkable jointing kit straight through type suitable for 11 KV, along with complette accessories suitable for XLPE armoured aluminium cable of 95/120 Sq mm 3 core complete all as specified and directed by Engineer-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 120 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. Note for Item No 61 to 62: (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule. (ii) Straight through joint will be measured and paid separately.
Disconnecting & Taking out HT underground aluminium conductor of size 90/120 sqmm 3 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed. Note : Excavation and earth work and taking out cable cover will be measured and paid separately.
Deployment of manpower and cable fault locator machine duly mounted on vehicle for detection of HT UG cable fault of any size & make by applying upto 15 KV supply to locate the fault and and if any necessary arrangements is required contractor shall provide the same. Note: In case HT cable fault is not detected, no payment shall be made to the contractor.
SURESH ELECTRICALS
High Tech Consruction
rajengineers
JAYESH TRADING CORPORATION
Sukhi Electricals
Chamunda Kruparefrigeration
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .