| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC Agreement executed by DIVIN SAM D S on 12.04.2023 |
Tender Value
₹1.4 L
EMD Value
₹3,600
Closing Date
25 Mar 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer Thiruvananthapuram Corporation 695033
Providing AC point at Call Centre of Health Section , Trivandrum Corporation
2023_LSGD_563549_2
DB/62983/2022-23(133)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
₹3,600
Yes
18 Apr 2023
17 Mar 2023
28 Mar 2023
17 Mar 2023
25 Mar 2023
17 Mar 2023
Amount
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.23.5 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2.3.6 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+6 way, Double door
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
MR(OD) Supply and installation Testing and Commissioning of 1.5 ton capacity high energy efficient ISEER ,5 Star Inverter type Split air conditioner operating on single phase AC supply ,full copper coil ,Non CFC Refrigerant , microprocessor control with cordless rmote including installation kit having dual copper tube for suction and discarge line , electrical wire etc complete.
MR(OD) Supply and fixing of Suitable Heavy duty metallic wall bracket/stand for the outdoor units of 2Ton Split AC units as per site conditions including cost of materials ,labour etc compplete and as per the direction of the Departmental Officers at site
MR(OD) Supply and fixing of Suitable Heavy duty metallic Body Voltage stabilizer 4KVA with voltage range of 175-275V and output range of 210-240V for 1.5Ton Split AC unit etc wall
MR(OD) Supplying and fixing of extra Soft drawn 22G Copper tube for suction and discharge suitable for the split AC units with insulation including cost of materials and labour etc (for 1.5Ton AC)
MR(OD) Supplying anddrawing of extra electrical wires of approved quality 2.5Sq.mm, ISI marked ,FRLS PVC insulated four core copper conductor cable for connecting the indoor and out door units of split AC unit including all cost of materials and labour etc
MR(OD) Supplying and fixing of 1Inch PVC pipe with fittings for draining the sweating water from the AC unit including costs of materials ,labour etc complete as per the direction of the Departmental officers at site
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_836906.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .