Opening, Boxing-up and Gasket replacement of Heat Exchanger end cups in Anone-5H Plant of FACT Petro-UC
2024_FACT_801561_1
5061/2023-2024/E29239
Limited
Miscellaneous Works
Item Rate
180 days
Udyogamandal
This tender is issued on limited tender basis and offers shall be accepted from the vendors on whom the enquiry is issued. Vendors interested in getting our future enquiries may contact DGM Projects and Planning - UC, FACT Udyogamandal
5 documents required · 5 mandatory
₹0
₹12,000
Yes
3 Apr 2024
19 Mar 2024
3 Apr 2024
19 Mar 2024
2 Apr 2024
19 Mar 2024
Opening, Boxing-up & Gasket replacement of Heat Exchanger end cups in Anone-5H Plant of FACT Petro-UC
Opening and boxing up of the end cups of E- 5002 Seal water cooler in Anone-5H Plant.
Opening and boxing up of the end cups of Heat Exchanger E- 5705 Cx condenser after distillation section in Anone-5H Plant
Opening and boxing up of the end cups of Heat Exchanger E- 5706 Cx cooler after distillation section in Anone-5H Plant
Opening and boxing up of the end cups of Intercoolers K-5401 ,
K-5401 Intercoolers tube bundle and demister pad to be taken out for demister pad inspection after completing inspection to be fixed back all in Anone-5H Plant.
Opening and boxing up of the end cups of Heat Exchanger E- 5501 absorber feed cooler after distillation section in Anone-5H Plant
Opening and boxing up the end cups, removal and re-fixing of tube bundle/floating head of E- 5707-Intercooler of K-5701 in Anone-5H Plant.
Opening and boxing up the end cups, removal and re-fixing of tube bundle/floating head of E-5708- after-cooler of K-5701 in Anone-5H Plant.
Opening and boxing up of manhole dummies and flange joints of sizes from 200NB to 350NB in R5411 to R5419 at oxidation section. Scope includes de-bolting, face cleaning, gasket cutting and replacement, boxing up and leak rectification. Slip Plate providing If any required etc.
Opening and boxing up of manhole dummies and flange joints of sizes from 400NB to 650NB in R5411 to R5419, S5601, S5602, S5603 and S5401 at oxidation section. Scope includes de-bolting, face cleaning, gasket cutting and replacement, boxing up and leak rectification, if any required
C5401,C5402, C5602, C5902and C5501 Manholes, and top cover opening and boxing up, if any required
S5202 Opening and boxing up of dummy for demister pad taken out for inspection after completing inspection pad to be fixed back. For tightening the bolts hydraulic or pneumatic torque wrench to be used.
S5203 Opening and boxing up of dummies for demister pad taken out for inspection after completing inspection pad to be fixed back.
E5901 Opening and boxing up of cups, dummies for demister pad taken out for inspection after completing inspection pad to be fixed back.
S5905 Opening and boxing up of dummies for demister pad taken out for inspection after completing inspection pad to be fixed back.
E5209 LP separator Opening and boxing up of dummies for demister pads taken out for inspection after completing inspection pad to be fixed back.
Unbolting and Re-bolting, replacing of gaskets, leak arresting of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face Cleaning, gasket cutting and boxing up in leak proof manner. (Rate per bolt / stud to be quoted) Bolt / stud size # from M12 up to and including M20. (Including the columns, tanks and vessels)
Unbolting and Re-bolting, replacing of gaskets, leak arresting of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face Cleaning, gasket cutting and boxing up in leak proof manner. (Rate per bolt / stud to be quoted) Bolt / stud size # above M20 up to and including M36. (Including the columns, tanks and vessels)
Unbolting and Re-bolting, replacing of gaskets, leak arresting of flange joints, dummies, manholes etc. with various pressure ratings in petro plant. Scope includes flange face Cleaning, gasket cutting and boxing up in leak proof manner. (Rate per bolt/stud to be quoted) Bolt/stud size – above M36 up to and including M56/(Including the columns, tanks and vessels)
Opening and boxing up of F5902 (Thermal Oil Furnace) Manholes & burners for the inspection, cleaning & repairing.
Assistance for various mechanical works (In Man days of 8 hour shift) in different category such as millwright fitters, pipe fitters, riggers & IBR qualified welders according to the requirement for machinery repair, pipe line work & all type of rigging works in connection with the maintenance activities in Petro Plants.
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .