Loading…
Loading…
Tender Value
₹158.0 Cr
EMD Value
₹3.2 Cr
Closing Date
27 Jul 2026, 3:00 pm
Bhavnagar Division: Codal life based replacement of existing PI stations with EI, MSDAC & in built block working including Signaling & Telecom equipment at 18 stations. Design, Supply, Installation, Programming, Testing and commissioning.
SnT_W_RJT_EPC_26_01
SnT_W_RJT_EPC_26_01
Open
24 Months
Bhavnagar, Gujarat
₹0
₹3.2 Cr
2 Jun 2026
2 Jun 2026
13 Jul 2026
27 Jun 2026
G-Project Lumpsum
Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN for Upto 10 routes. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, 1 Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.
Supply, Installation Testing and Commissioning of block proving by digital axle counter (BPAC) using UFSBI for Single line operation as per RDSO specn. No IRS/S/105/2025 (Ver.1.0) it comprises of auto change over facility for quad and OFC working. Necessary modem for quad and OFC should be supplied along with auto changeover arrangement details are as follows. (i) Universal 2 fail safe block interface (UFSBI) with complete accessories as per RDSO specn no. IRS/S/104/2012(Ver.0) (ii) Block panel as per RDSO S-32019 (iii) Relay rack with locking and sealing arrangement duly wired as per RDSO: S:32020 along with complete relays. (iv) Block telephone with accessories as per RDSO/SPN/191/2005. (v) Automatic media changeover along with additional modem as per manufactures specification for BPAC using UFSBI (item no i) for supply of above items. Unit will be in set consisting of 02 nos of each items.
Installation, Testing & commissioning of Block panel including UFSBI equipment as per standard practice & directive on 1:3:6 CC foundations as per drawing No CSTE 6095.
Supply of VRLA Valve Regulated (Sealed) Lead Acid battery as per RDSO IRS-S-93/96 (A) with Amd-01 for Railway Signalling Installation in IPS. Capacity-2V 300AH. Inspection:RDSO
Supply of Double Rail contact assembly with track side EJB for MSDAC. Each set shall consist of track side electronic unit, Double rail contact with cable and mounting accessories. This item shall be procured from RDSO approved firm and inspected by RDSO.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2lineSTNYARD-Model_1.pdf
ATTACHMENT
234ASPECTSIG.UNITAPPROVED.pdf
ATTACHMENT
3lineSTNYARD-Model.pdf
ATTACHMENT
4lineSTNYARD11.05.2026-Model.pdf
ATTACHMENT
FullLocdrgtypical10122024.pdf
ATTACHMENT
SignallingBoards.pdf
ATTACHMENT
TypicalLBdetailswithPointJBEI.pdf
ATTACHMENT
TypicalPtCktforEIParallelPolicy02_2025.pdf
ATTACHMENT
TypicalTFCfailalarm.PDF
ATTACHMENT
TypicalVDULayout.pdf
ATTACHMENT
Typicalpointinterfaceckt.pdf
ATTACHMENT
11_03_25TechnicalSystemApplicationApprovalTSAAofDigitalAxleCountersysteminstallationsbeforecommissioining.pdf
ATTACHMENT
20.3.2026PolicyCircularforimplementationofEIBitConfigurationforDataLoggerExceptionSMSGeneration.pdf
ATTACHMENT
BerthingTrackcircuit.pdf
ATTACHMENT
CLSunitpolicy.pdf
ATTACHMENT
consigneeinspectionletter.pdf
ATTACHMENT
CorrigendumtoPolicyNo-207-2016dated07-07-2016TypicalDrawingsforAutoresettingcircuitsforMSDAC1.pdf
ATTACHMENT
Datalogger.pdf
ATTACHMENT
DigitizationofCableRoutePlanCRP10062020.pdf
ATTACHMENT
DIRTYCLEANSEGREGATION-1.pdf
ATTACHMENT
Earthingandsurgeprotectionsystemsforsignallinginstallation.pdf
ATTACHMENT
EarthingofQuadCableatintermediatelocationboxes.pdf
ATTACHMENT
EarthingbondingsurgeProtection-compressed.pdf
ATTACHMENT
EIpolicies.pdf
ATTACHMENT
ELBPEDSTALHEIGHTINCDIA.pdf
ATTACHMENT
Foundationformainsignalpost.pdf
ATTACHMENT
IntegratedCRPpolicy21.pdf
ATTACHMENT
IPsdrawing.PDF
ATTACHMENT
JointProcedureOrderforresettingtheDigitalAxleCounteronWR..pdf
ATTACHMENT
letterofcablecut07.07.2023.pdf
ATTACHMENT
ModificationinCH_SG_217_3_2_Vol_III-Dt21.10.2016.pdf
ATTACHMENT
Policy_SMSfordatalogger.pdf
ATTACHMENT
PolicyfordistributedEIwork1.pdf
ATTACHMENT
PolicyforSiginstallations15042024.pdf
ATTACHMENT
PolicyNo-03.2024.pdf
ATTACHMENT
PolicyonWritingwork.pdf
ATTACHMENT
Policy-ModifiedmeasuresonBerthingTrackCircuit.pdf
ATTACHMENT
Sparekeyuse02052023.pdf
ATTACHMENT
Tele_Cir_9-2023Cabledamagepenalty.pdf
ATTACHMENT
ThefeatureofbypassingtheLVDSinIPSforLMLAbatteries..pdf
ATTACHMENT
Typicalpointinterfaceckt_1.pdf
ATTACHMENT
WR-JPO-DisconnectionReconnectionProtocols.pdf
ATTACHMENT
Tentative6ESPSahpurVirpurMahuaBVPSongarhVertej_merged.pdf
ATTACHMENT
Tentative4ESPLushala_Kasod_Maliya_Chorvadmerged.pdf
ATTACHMENT
Tentative5ESPadriroad_SanosaraVeravalGondalRibdamerged.pdf
ATTACHMENT
Tentative2ESPKhodiyarMandir_Palitanamerged.pdf
ATTACHMENT
Sihor_compressed.pdf
ATTACHMENT
EPCRFP_uptoAmendmentNo_2_020626.pdf
ATTACHMENT
EPCAgreement18stnEI020626.pdf
ATTACHMENT
Feasibilityreport18stn020626.pdf
ATTACHMENT
Download all tender documents and submit your bid