| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.8 LAccepted-Finance | L1 | Accepted-Finance Lowest rate quoted. | |
| 2 | L2₹85.8 L+₹4.0 L (4.90%)Rejected-Finance 116 SHANTINAGAR ROAD BHADRAKALI UTTARPARA HOOGHLY WEST BENGAL 712232 | HOOGHLY | WEST BENGAL | 712232 | L2 | Rejected-Finance High rate quoted. | |
| 3 | L3₹86.0 L+₹4.2 L (5.07%)Rejected-Finance | L3 | Rejected-Finance High rate quoted. | |
| 4 | L4₹88.0 L+₹6.1 L (7.50%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L4 | Rejected-Finance High rate quoted. | |
| 5 | L5₹95.4 L+₹13.6 L (16.6%)Rejected-Finance | L5 | Rejected-Finance High rate quoted. |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
6 Dec 2024, 4:00 pmClosed
SE,SEC,PWD
Office of the Superintending Engineer SOUTHERN ELECTRICAL CIRCLE, 2nd FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059.
SITC for Air conditioning system including their necessary electrical works for Ejlas and Chamber in all Court of Zilla Adalat Bhawa North 24 Parganas Barasat SITC of central Air conditioning system
2024_WBPWD_769527_1
WBPWD/SESEC/eNIT-07/24-25
Open Tender
A/C ORG
Item Rate
120 days
Barasat
As per NIT
4 documents required · 4 mandatory
₹1.8 L
Superintending Engineer SEC PWD
21 Jan 2025
14 Nov 2024
9 Dec 2024
14 Nov 2024
6 Dec 2024
22 Nov 2024
20 Nov 2024
Amount
OUTDOOR UNIT: SITC of Air cooled VRF top discharge type Outdoor Unit (cooling only) each comprising of variable speed all inverter controlled scroll/Rotary compressor, air cooled copper condensor with protective coated fins, mounting frame, micro processor control panel and other standard accessories according to OEM standard. The unit shall be suitable for operation with R-410A refrigerant. Minimum EER at 100% load & at minimum 35 degree centigrade ambient condition should not be less than 10 (Ashree standard table 6.8.1 L). Nominal capacity of outdoor units in BOQ at climatic condition of kolkata taking into consideration of ambient correction factor as per OEM standard to deliver inside temparature condition @24 ±2 degree centigrade. The outdoor unit should be combination of multiple modules and each of the module should contain multiple variable speed inverter type scroll or rotary compressors. The rate is inclusive of anti vibration foot pad, Y conectors at ODU side if any. (Make-Mitsubishi/Blue Star/Hitachi /Toshiba/ Carrier/ Voltas / Daikin / O'general)
INDOOR UNIT: Supply, Installation, Testing & Commissioning of Wall Mounted/Ceiling Suspended Compact type(as per site condition) Indoor Units for VRF system & allied accessories : (Make-Mitsubishi/ Blue Star /Hitachi/ Toshiba / Carrier / Voltas / Daikin / O'general) .
Hi-Wall VRF IDUs for Chambers:
3.6 KW cooling capacity (minimum) indoor unit or better with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
5.5 KW cooling capacity (minimum) indoor unit or better with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
7.1 KW cooling capacity (minimum) indoor unit or better with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
9.0 KW cooling capacity (minimum) indoor unit or better with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
High Static Ductable VRF IDUs for Court Rooms
11.2 KW cooling capacity (minimum) indoor unit or better with minimum three steps speed regulator, with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
14 KW cooling capacity (minimum) indoor unit or better with minimum three steps speed regulator, with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
16 KW cooling capacity (minimum) indoor unit or better with minimum three steps speed regulator, with corded/cordless remote and noise level, air flow & static pressure as OEM standard.
Supply Installation Testing & Commissioning concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1No. twin rotary / scroll compressor, 1no. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-220V-1ph-50Hz. Air-flow/per IDU:- 600-800CFM. . (Make-Mitsubishi/Blue Star/Hitachi /Toshiba/ Carrier/ Voltas/Daikin/O'general)
Supply, installation, testing and commissioning of Supply of refrigerant distribution joints for taking branches between one outdoor and various indoor units Y-joints & Piping Connection Kit, Complete with insulation as per OEM standard.
SITC of the of required size of hard drawn/soft drawn copper refrigerent piping System as per OEM standard including vaccumiazation and Nitrogen of testing for VRV/VRF AC system, complete with fittings, with adjustable ring type hanger supports, jointing/ brazing including accessories as required at site & approved by EIC, duly insulated with XLPE class -O tubular closed cell elastomeric nitrile rubber insulation (Make : Armacell/ K- flex/ Aeroflex/ A-flex) of 13mm thickness upto 15.9 mm OD Cu pipe & above 19mm thick insulation for higher sizes Cu pipes.
Supply and Laying of Rigid PVC Drain Pipe (Medium Class)with respective fittings ,proper supports at 5 feet interval and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Make : Oriplast/ Supreme/ Filolex/ Ashirbad/ Astral)
a) 40 mm dia
b) 32 mm dia
Supply, delivery & fixing of control cum transmission line wiring with following size Copper conductor sheilded cable along with conduit for looping between indoor & outdoor VRF system & to main Central remote controller system. 1.1 KV GRADE PVC INSULATED COPPER CABLES
a) Cable Size :- 3C x 1.5 mm² (Make: Finolex/Havells/PolyCab/RR Kabel)
Supply, delivery & fixing of control cum transmission / power line wiring with following size Copper conductor sheilded cable along with conduit for looping between indoor & outdoor VRF system & to main Central remote controller system. 1.1 KV GRADE PVC INSULATED COPPER CABLES
a) 4 Core 1.5 mm² (Make: Finolex/Havells/PolyCab/RR Kabel)
b) 4 Core 16 mm² copper armoured (Make: Finolex/Havells/PolyCab/RR Kabel)
c) 4 Core 10 mm² copper armoured (Make: Finolex/Havells/PolyCab/RR Kabel)
Supply, Installation and Testing of Grilles/ Diffusers as per specifications and drawings.
Aluminium Supply grill with VCD
Aluminium Contineous grill without VCD
Aluminium Supply difusser with VCD
Aluminium Contineous difusser without VCD
Supply & Fixing of class-VIII grade (120GSM) confirming to IS -277 & Supply air duct along with necessary support, flanges etc. as required and as per IS -655 standards of following gauges. (Make - Tata/ Sail/ Jindal)
a) 0.63 mm (24 SWG)
b) 0.80 mm ( 22 SWG)
Supply and fixing acoustic lining of supply air duct and plenum with 10mm thick open cell fire retardant Anti- microbial type Nitrile rubber (Class-O) of density 140Kg/cum-160Kg/cum insulation with cadmium plated nuts, bolts, stick pins, CPRX compound etc. completed as per direction of EIC. (Make - Accroflex/ K-flex/ Armacell)
Supply and fixing Heat Retardant closed cell Class'O' 19mm thick fire retardant Anti-microbial type Nitrile Rubber insulation with AI Foil Faced Outside Supply Air duct. (Make - Armacell/ K-flex/ Accroflex)
Supply & fixing of fire retardant nonporous double layer flexible connection (CANVAS) between each indoor unit and duct/ Grill, as per direction of E.I.C.
Supplying, Installing, Testing and Commissioning which will make the entire system as complete and functional and prove the practical results as per the design guidelines with all lead and lifts,- perforated type cable tray, Prefabricated - cable trays - made out of 2 mm thick galvised sheet. Rate shall include necessary angle iron support and M10 full threaded down rods, M10 anchor fasteners etc., complete. Maximum height of suspension shall not exceed 500mm. The support shall be provided at every 1 Mtr.
Size of Cable Tray :200 mm x 50 mm
Size of Cable Tray :150 mm x 50 mm
Supply and Delivery of High-wall Split Air Conditioner having following specification: Cooling capacity - 5.2 KW (Minimum) Minimum ISEER - 3.8, BEE levelling - 3-Star (min) [1st July 22 to 31st December 2025] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrite rubber insulation and warping tape - 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type- make: Finolex/Polycab/RR-Kabel)- 3 mtr. and with 25A plug top with indicator. (Legrand-Myrius/ Honeywell MK). [O.General / Mitsubishi Electric / Zamils].
Installation,Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigant, S&F of necessary fixing arrangement for indoor and 40x40x5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of EIC.
Supply, erection & installation of fabricated MS Structure comprised of 'I'section Beam , 'C' channel, MS flat etc for platform suitable for mounting Outdoor unit including painting by anti-corrosive paint over RO primer including wall cutting, grouting with cement concrete, as per direction of EIC.
Supply & Fixing of Fusiable Link Fire Damper, Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995) with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed. (Make - Greenheck/ Systemair/ Air master/ Caryaire)
Supply and charging of R410A refrigerant gas for entire system including Testing and commissioning of complete VRV system including all indoor units,outdoor units,electricals,remotes etc including pressure testing with nitrogen & vaccumasation.
Making wall opening for copper and drain pipe line and also making scaffolding arrangement for installation of copper line at outside of the building.
Note 01 : Any other item or items left out from BOQ but essentially required for successful completion of the work may be raised for inclusion in the scope of work during pre-bid meeting.Otherwise bidder has to consider left out items deemed to be included in the scope of work. Bidders are advised to visit the site and and quote the price -accordingly. Note 02: An Autocadd Generated Drawing has to be approved before starting of any construction & Materials to be approved by E.I.C. Note 03: The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer for technically supervise and participate during all of the adjustments and tests for the system. Note 04: Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules The defect liability period (DLP) of the aforesaid work will be for the period of THREE (03) years from date of completion.
AIR Q SOLUTIONS (BID ID -5804671)
ELECTRIC REFRIGERATION (BID ID -5812984)
CARRION AIR COOLING (BID ID -5811983)
TRANSTECH (BID ID -5802090)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .