Executive Engineer (Civil)
Office of the Executive Engineer (Civil), BSNL Civil Division, Raj Kishore Nagar Telephone Exchange, IInd Floor, Bilaspur (Chhattisgarh), Pin 495006.
Special repairs to 2 Nos. Type-IV BSNL Staff Quarter at Ground floor i/c Repairs to Chajja, provision of New sewer/Water Supply line, New Septic tank and other ancillary Civil works at City Exchange Compound Bilaspur (CG).
2025_BSNL_225123_1
45/2024-25/BSNL/CD/BILASPUR Date 28.01.2025
Open Tender
Civil Works
Item Rate
90 days
BILASPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Account Officer (Cash) O/o GM BSNL Bilaspur BA
₹16,350
5 Mar 2025
28 Jan 2025
13 Feb 2025
28 Jan 2025
10 Feb 2025
28 Jan 2025
28 Jan 2025 - 10 Feb 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil.
Clearing jungle including uprooting of rank vegatation, grass, brush wood, trees and saplings of grith up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level :
1 : 2 : 4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size).
1 : 5 : 10 (1 Cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. bricks of class designation 35 in foundation and plinth in :
Cement mortar 1 : 4 ( 1 cement : 4 coarse sand).
Cement mortar 1 : 6 ( 1 cement : 6 coarse sand).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete.
Deduct for providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC-10 as per IS : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc complete :
Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete :
Providing and fixing aluminium handles ISI maked anodized ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solventcement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.
30 mm thick plain PVC door shutters
Structural steel work riveted, bolted or welded in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion : Single socketed pipes :
75 mm diameter.
110 mm diameter.
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion :
Bend 87.5 degree :
75 mm bend.
110 mm bend.
Shoe (plain) :
75 mm shoe.
110 mm shoe.
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) and making good the walls etc complete :
12 mm cement plaster of mix :
1 : 6 (1 cement : 6 fine Sand ).
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :
1 : 3 (1 Cement : 3 fine sand).
Neat cement punning.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
Old work (one or more coats)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
Old work (one or more coats applied @ 0.83 ltr/10 sqm).
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters20 mm in patches of area 2.5 sq meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to dumping ground within 50 metres lead :
With cement mortar 1 : 4 (1 cement :4 coarse sand).
Renewing glass panes and refixing existing wooden fillets :
Float glass panes of thickness 4 mm.
Carriage of materials like excavted earth, moorum, excavated rocks, building rubbish, malba, sludge etc. by mechanical transport to the dumping ground including loading, unloading, stacking, spreading and levelling etc. as per requirement within municiple limits complete as per direction of Engineer in charge.
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Removal of choakage from C.I. / HDPE pipes and fittings SW pipes etc. upto gully traps cleaning and disposal of all types of rubbish and sludge as directed by Engineer in charge.
Providing skilled labour for trade like plumbing / masonry / carpentry / works which are not covered and measurable in items of DSR [Note: contractor shall provide skilled labour of respective trade alonghwith necessary tools and plants].
Providing unskilled/casual labour, coolie / beldar for day to day maintainance work which are not covered and measurable in items of DSR.
Demolishing cement concrete & CC Flooring manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Demolishing R.C.C. work ( like Chajja, Beam, R.C.C. walls, R.C.C. Fins & Slab at all Height ) manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Repairs to wooden / aluminium doors, windows etc. including dismantling and refixing the same with screws, or by welding if required hinges, etc. doing all the operation complete as per direction of Engineer in charge. [Note: New Section, new hinges, fittings etc. if required will be paid for separately].
Providing and fixing wash basin with C.I. brackets, including painting of fittings and brackets, cutting and making good the walls wherever required.
White Vitreous China Flat back wash basin size 550x400 mm.
Providing and fixing white vitreous china water closet squatting pan (Indian type) :
Orissa pattern W.C. pan of size 580x440 mm including necessary PVC P or S trap required at site.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fitures complete :
10 Litre capacity - white.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :
Semi rigid pipe :
32 mm dia.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia .Pipes.
40 mm nominal outer dia. Pipes.
50 mm nominal outer dia. Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall :
15 mm dia nominal bore.
20 mm dia nominal bore.
25 mm dia nominal bore.
40 mm dia nominal bore.
50 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work
40 mm dia. nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing unplasticised PVC connection pipe with brass unions :
30 cm length :
15 mm nominal bore.
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
15 mm nominal bore.
20 mm nominal bore.
25 mm nominal bore.
40 mm nominal bore.
50mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing C.P. brass Pillar cock 15 mm nominal bore of standard design and of approved make conforming to IS specification.
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Credit for brass 15 mm nominal bore stop cock / bib cock / pillar cock / gate valve.
Credit for 15 to 40 mm nominal bore G. I. pipe line obtained from dismantling.
Providing and fixing HDPE tank cover with suitable locking arrangement complete as per direction of Engineer in charge.
Providing and fixing brass half turn gate valve with M.S. handle of ZOLOTO or equivalent make as approved by the Engineer in charge and as per manufacturer specification:
15 mm nominal bore.
20 mm nominal bore.
25 mm nominal bore.
40 mm nominal bore.
50 mm nominal bore.
Supplying and fixing C.I. cover without frame for manholes :
455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg.
Providing laying and jointing PVC SWR Type "B" soil waste and vent pipes conforming to IS 13592:2013, including jointing with seal ring conforming to IS: 14735:1999, including jointing the pipes with appropriate adhessive as per the manufacturers specifications and testing of joints etc. complete.
160 mm diameter pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. R pipes including bed concrete as per standard design :
150 mm nominal
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab 100 mm thick with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including 75 mm thick precast R.C.C. cover 455x610 mm internal dimensions, The top slab during casting necssary receiving arrangement for cover is to be made for proper finishing.
With common burnt clay F.P.S. (non modular) bricks of class designation 3.5)
Extra for depth for manholes :
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Dismantling S.W. pipes including dismembering the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
100 to 150 mm diameter pipes
Providing and fixing Standard Brass waste Coupling to Wash Basins/Urinals of required size etc. complete as directed by the Engineer-in-Charge.
Removing of G I pipes (Internal work)including removing clamping and stacking at required place as directed by Engineer-in-charge.
15 mm to 50 mm dia G.I.Pipe
Providing and fixing G.I. tank nipples and washers for preventing leakage of tank, cutting and threading the pipe and making long screws and fixing of tank nipples in PVC tank with M-SEAL etc. complete wherever required and as per direction of Engineer in charge :
Welding of hinges to M.S.frames of Doors/ windows including cutting & taking out the damaged structural member & providing the new M.S. Structural member (Hinges to be paid separately ) including to & fro movement of welding plant using approved quality welding rods complete as per direction of Engineer -in - Charge
Providing and fixing double scaffolding system (with bamboo) on the exterior side, up to seven story height made with 40 mm dia Bamboo 1.5 m centre to centre, horizontal & vertical bamboo joining with Coconut Rassi, challies, Bamboo staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Providing and fixing unplasticised Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion : Single socketed pipes :(Prince or supreme or equivalent.
150 mm diameter pipes
Providing and fixing G.I. pipe fittings in existing G.I. pipe line like nipple, elbow, tee, sockets, reducers etc. as per the direction of Engineer in charge.
15 mm to 40 mm nominal bore.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .