| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹87.2 CrAdmitted-Finance | +0.00% | ₹87.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹89.2 CrAdmitted-Finance | +0.00% | ₹89.2 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Does not qualify in PQR of the tender. |
Tender Value
₹45.5 Cr
EMD Value
₹91.0 L
Closing Date
7 Feb 2022, 5:00 pmClosed
Superintending Engineer,Contract and Procurement-I
VCV Gabar Singh Urja Bhawan
Works of Repair and Comprehensive maintenance contract of capacitor banks installed at various 33/11KV Sub-Stations of UPCL on turnkey basis
2022_UPCLC_41798_1
CCP-I/55/2021-2022
Open Tender
Electrical Works
2005 days
As per tender specification
As per tender specification
6 documents required · 6 mandatory
₹29,500
Yes
Executive Engineer, ESD, UPCL
₹91.0 L
Yes
VCV Gabar Singh Urja Bhawan
10 Mar 2022
15 Jan 2022
8 Feb 2022
15 Jan 2022
7 Feb 2022
31 Jan 2022
21 Jan 2022
Amount
Repairing, servicing and general overhauling of 12.65 kV, 1200 KVAr, 3-Phase Automatic Power Factor Correction Panel, housed in Outdoor Type IP 55 CRCA cubicle or on outdoor GI structure; having one variable step of 600 KVAr and two variable steps of 300 KVAr & Indoor Type Automatic Power Factor Controller and replacement of any faulty component (if need be).
Repairing, servicing and general overhauling of 12.65 kV, 1800 KVAr, 3-Phase Automatic Power Factor Correction Panel, housed in Outdoor Type IP 55 CRCA cubicle or on outdoor GI structure; having three variable steps of 300 KVAr, 600 kVAr & 900 KVAr & Indoor Type Automatic Power Factor Controller and replacement of any faulty component (if need be).
Repairing, servicing and general overhauling of 12.65 kV, 2400 KVAr, 3-Phase Automatic Power Factor Correction Panel, housed in Outdoor Type IP 55 CRCA cubicle or on outdoor GI structure; having one variable step of 300 KVAr, two variable steps of 600 KVAr & one variable step of 900 KVAr & Indoor Type Automatic Power Factor Controller and replacement of any faulty component (if need be).
Repairing, servicing and general overhauling of 12.65 kV, 3000 KVAr, 3-Phase Automatic Power Factor Correction Panel, housed in Outdoor Type IP 55 CRCA cubicle or on outdoor GI structure; having three variable steps of 900 KVAr & one variable step of 300 KVAr & Indoor Type Automatic Power Factor Controller and replacement of any faulty component (if need be).
Repairing, servicing and general overhauling of 12.65 kV, 3600 KVAr, 3-Phase Automatic Power Factor Correction Panel, housed in Outdoor Type IP 55 CRCA cubicle or on outdoor GI structure; having one variable step of 300 KVAr, one varialbe step of 600 KVAr & three variable steps of 900 KVAr & Indoor Type Automatic Power Factor Controller and replacement of any faulty component (if need be).
Repairing, servicing and general overhauling of 11 kV, 630 Amp, Off Load Isolator with earth switch and replacement of any faulty component/ part (if need be).
Replacement (if need be) of defective 9 kV, 10KA, Station class (III), Lightning Arrestors
Repairing, servicing and general overhauling of 11 kV outdoor VCB Switchgear and Indoor Type Control & Relay Panel along with complete arrangement for connection and replacement of any faulty component/ part (if need be).
Repairing, servicing and Replacement (if need be) of Control Cables
size 4x2.5sq.mm.
size 6x2.5sq.mm.
size 10 x2.5sq.mm.
Servicing and Replacment (if need be) of 11 KV XLPE insulated 3x185 mm2 Armoured
Replacement (if need be) of Heat Shrinkable Jointing kit for 11KV 3x185 sq. mm. XLPE Cable
Indoor termination Kit
Outdoor termination Kit
Repairing, servicing and general overhauling of CT outdoor as per specification (1 set=3 nos.)
Replacement of Electrode Chemical Earthing and GI earthing strip (50 X 6 MM) as mentioned specification for equipment
Description of Work / Item(s)
Amount
Annual Maintenance Charges for 12.65 kV, 1200 KVAr, 3-Phase Automatic Power Factor Correction Panel and all other associated equipment ( including all material/spare parts required to keep the system healthy for 5 years.)
Annual Maintenance Charges for 12.65 kV, 1800 KVAr, 3-Phase Automatic Power Factor Correction Panel and all other associated equipment ( including all material/spare parts required to keep the system healthy for 5 years.)
Annual Maintenance Charges for 12.65 kV, 2400 KVAr, 3-Phase Automatic Power Factor Correction Panel and all other associated equipment ( including all material/spare parts required to keep the system healthy for 5 years.)
Annual Maintenance Charges for 12.65 kV, 3000 KVAr, 3-Phase Automatic Power Factor Correction Panel and all other associated equipment. ( including all material/spare parts required to keep the system healthy for 5 years.)
Annual Maintenance Charges for 12.65 kV, 3600 KVAr, 3-Phase Automatic Power Factor Correction Panel and all other associated equipment ( including all material/spare parts required to keep the system healthy for 5 years.)
Century Infrapower Private Lmited
Century Infrapower Private Lmited
Century Infrapower Private Lmited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.03 MB
TENDERDOCCAP_AMC.pdf
Tender Documents • 0.74 MB
AMCPQRSheetCCPI5520212022.xls
Additional Documents • 0.03 MB
BOQ_49648.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid