Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹43.9 L+₹69,494.44 (1.61%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹44.5 L+₹1.2 L (2.89%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹45.4 L+₹2.2 L (4.98%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹46.4 L+₹3.2 L (7.34%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Aug 2023, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
PROVISION OF 90 LED SECURITY LIGHTS AT JADUNATH SINGH LINES SPECIAL REPAIR REPLACEMENT OF LT OVERHEAD LINES AND CERTAIN MINOR WORKS UNDER GE UTILITY AMBALA CANTT
2023_MES_609745_1
CA NO GE U AMB T 57 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹96,000
30 Sept 2023
19 Jul 2023
21 Aug 2023
19 Jul 2023
19 Aug 2023
5 Aug 2023
19 Jul 2023 - 26 Jul 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes, for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick compacted each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection complete all as specified and as directed.
Material and labour cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of pole and strut, stay around the pole and making good the distrubed surface etc complete all as specified and directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Supply and laying, connecting and testing of XPLE underground cable insulated, and overall sheathed with cluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc. Note : (i) Earth work, sand , bricks removing , returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item ser No 8 here in before but for 4 core 16 Sqmm
All as per item ser No 8 here in before but for 4/3.5 core 25 Sqmm
All as per item ser No 8 here in before but for 3.5 core 35 Sqmm
All as per item ser No 8 here in before but for 3.5 core 50 Sqmm
All as per item ser No 8 here in before but for 3.5 core 70 Sqmm
All as per item ser No 8 here in before but for 3.5 core 95 Sqmm
All as per item ser No 8 here in before but for 3.5 core150 Sqmm
All as per item ser No 8 here in before but for 3.5 core 300 Sqmm
Supplying and fixing of light grade galvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps , bolts , nuts and washers all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule
All as per Item No 17 here-in-before but of size 50 mm bore.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique or manual boring and necessary machine including HDPE pipe of 50mm to 150 mm dia suitable for 0.4 mpa working pressure.
Supply and fix of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as directed by Engr-in charge.
Supply and fix of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as directed by Engr-in charge.
Supply and fix of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as directed by Engr-in charge.
Dismantling concrete poles/ struts, any size, setting aside for issue to sch of credit complete all as specified and as directed by the Engineer in Charge.
Dismantling existing ACSR (of any size or type) from over head electric line carefully with out making any damage to the other existing lines and removing from site complete all as specified and as directed by the Engineer in Charge.
Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and directed
Dismantling of cross arms, bracings, supports etc of MS channel or any other section complete and setting removing unserviceable portion from site of work complete all as specified and as directed
Dismantling of insulator any type /size/ grade from over head electric line and setting aside removing from site complete all as specified and as directed by the Engineer in Charge.
Supply and installing, testing & commissioning of factory fabricated outdoor type feeder pillar board of size 900X750X500 mm , outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on door 01 no of pad lock of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coated painting after 7-tank pre treatement control & power wiring with suitable size of copper conductor along with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 56 KA comprising of the following :- (a) MCCB 125 Amps TPN, 25 KA adjustable type microprocessor release -01 No (Make:- Havells/L&T/Legrand/Indoasian/ABB) (b) MCCB 40 Amp, 10 KA TP 415 volts AC, (Outgoing)-06 Nos (Make:- Havells/L&T/Legrand/Indoasian/ABB) (c) Cu busbar of capacity 200 Amps with colour coated heat shrinkable sleeve and suitable hole for out going connection - Set of four. (d) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates
Notes for item Sr No. 28 to 31 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panels through gland. (vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
Material and labour for earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2 Ώ earthing will be redone at no extra cost
Supply and fixing of cable gland as per cable size in the LT panels complete all as directed by Engr-in charge.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas exceeding 1.5 m in width as well as 10 sqm on plan but n.exc 1.5 m in depth including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge
Excavation in trenches not exceeding 1.5 metre wide and exceeding 1.5 metre deep but not exceeding 3.0metre deep in loose / soft soil and getting out for under ground cable / errection of poles stays etc complete all as specified and directed.
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP 31 , 9 meter long incl providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as directed at site. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Supply, fixing of PVC insulated round 3 core 1.5 sqmm copper cable with PVC conduit pipe fixed with clamp & nuts bolts including electrical connection suitable size of lugs, complete all as specified and directed by Engr-in-charge.
Supply & fixing of LED street light fitting 90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Make :- Havells cat part No ENDURAOMNIPLUSSL90WLED757SASYTOPC or equivalant of make given in Appx 'B'. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street shall be measured and paid for separately.
Supply and fixing of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium busbar and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make:Sintex/Hensel/Siemens/Rittal.
Supply & Fixing of bracket made out of GI tubing single piece bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket of street light fitting all as specified and as directed.
Supply & Fixing of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed
Supply & fixing of Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 16 Amps per phase, MCB rating 20 Amp, max load 5-8 kw incl circuit copper wire 10 sq.mm. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Madel : Swadeep-02EC-5kW3P-VMS or equivalent in the make given in Appx 'B' complete all as specified and directed. Note (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years. (iii) The test certificate and warranty cirtificate must be provided by supplier.(iv) Cost of marking description on the box is incl quoted rate.
Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe (medium grade) for protection of GI earth lead wire including 20mm bore GI pipe (medium grade) for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
Material and labour for cable route indicator showing "MES LT UG 1.1KV" and route of cable with arrow (should be embossed or engraved) made of RCC in suitable shape and fixed in PCC block 1:3:6 type C-2 using 40mm graded aggregate including brick work and excavation, size of route indicator 70cm x 30cm x 10cm, 30cm below ground level and 40cm above ground level to show clear indication of cable including painting the complete slab with red paint and making the engraved/embossed letters/arrow with white paint complete, all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR, Make - O-General/ Hitachi/ Bluestar.
Supply and fix automatic voltage stabilizer, single phase wall mounted copper wound air cooled digital display and designed for input variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5.0 KVA, Make : Vguard/Volina/Microtech or make given in Appx 'B'.
Wiring for circuit/submain wiring alongwith earth wire with the 2x4.0 sq. mm + 1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required.
M&L for single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB 20 Amps ISI mark.
M&L for wall stand suitable outer unit 1.0/1.5/2.0 TR.
Supply & installation of desert coolers having nominal air flow capacity 4000 cum per hour of 60x60x825 mm made out of PGI sheet not less than 0.90 mm thick for fixed parts and not less than 0.70 mm thick for front grill as approved, the desert coolers having copper wounded fan motor 480 mm sweep, 1350-1400 RPM, 230 volts, 50 Hz with submersible water pump 18/20 watt for required flow of water including havin three speed regulator (high/medium/low) with and including provision of two coats of synthetic enamel anticorrosive oven dried paint over a coat of redoxide primer complete all as specified and directed, Make - Khaitan/Crompton/Bajaj.
M&L for MS work fabrication and structural steel section including cutting, welding, grounding and fixing in wall in any shape and angle iron size 40x40x5 mm desert cooler stand.
Material and labour for Point wiring with 2 Run of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit medium grade not less than 20 mm dia with accessories/ casing caping, concealed/surface type on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including sunken pressed steel terminal boxes (modular type, size/modules as required at site) with and including screws, modular cover plate over sunken box for housing the modular switches, socket outlets & fan regulators etc and making good the disturbed surfaces as per existing for:- One light point/bell/fan point controlled by one switch Note:-1. Modular metal flush/sunken Box, and for modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 2. Switch, socket and fan regulators to be measured and paid separately.
S&F modular switch 6 Amp 1 way 1 module 230 volts complete all as specified & directed. Make - Indoasian/Anchor/Philips/L&T
Supply and fix air cooled split unit air conditioner hot & cold electric driven, single phase of capacity of 1.5 TR having 5 star rating. Make - O-General/ Hitachi/ Bluestar.
Supply and fix refrigerators frost free double door , electric driven (single phase), capacity 310 Litres atleast BEE 3 star rated. Make- LG,Lloyd, Samsung, Voltas
Supply and fix automatic voltage stabilizer, single phase wall mounted copper wound air cooled digital display and designed for input variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 3.0 KVA, Make : Vguard/Volina/Microtech.
Note:- Amount of credit of Rs 22625.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
R. P. Suppliers and Construction Co.
GULSHAN SINGH GHAI AND SON
unique power & control system
UNITED ENGINEERING CORPORATION
AR CONSTRUCTIONS
Raman Electric Trading Co
M/S SURINDER KUMAR MAHAJAN
M/s Kang Builders & Developers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .