GE (AF) Bidar
Garrison Engineer (Air Force) Bidar, Military Engineer Services, Air Force Station Bidar, Bidar-585401
MAINT AND REPAIRS, REPLACEMENT OF LT JOINTS, LAYING OF CABLES AND CONNECTED MISC WORKS AT AFS BIDAR
2026_MES_799267_1
CA NO. GE(AF)/BID/TOKEN/50 OF 2026-2027 8271/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹10,000
Yes
18 Nov 2026
18 Nov 2026
16 Dec 2026
18 Nov 2026
9 Dec 2026
2 Dec 2026
18 Nov 2026 - 1 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Schedule of Works | - | - | - | - |
| 1 | Taking out faulty underground AFLC cable of grade 1.1 kv to 6.6 kv of sizes varying from 6 Sq mm to 50 Sq mm, 2 / 3.5 / 4 Core, keeping aside serviceable cable, cable route indicators etc., for reuse, complete all as specified and as directed.
Note : Excavation and earthwork will be measured and paid for separately under respective items. | 400 | RUNNING METRE | 100 | ₹40,000 |
| 2 | Laying of AFLC cable of 1.1 kv to 6.6 kv of sizes varying from 6 Sq mm to 50 Sq mm, 2 / 3.5 / 4 Core, in trenches after rectification of fault, rerouting, readjusting loops, etc., complete all as directed by Engineer-in-Charge.
Note :
i) Serviceable cable obtained from Serial Item No 1 here-in-above, shall be re-used under this item.
ii) New cable where required will be issued by AF Authorities. | 400 | RUNNING METRE | 10 | ₹4,000 |
| 3 | Taking out faulty LT underground XLPE / PVC cable of grade 1.1 kv to 6.6 kv of sizes varying from 6 Sq mm to 50 Sq mm, connected to UG / OH lines, Panel boards, etc., and reconnecting the same with suitable aluminium lugs complete all as directed by Engineer-in-Charge. | 6 | EACH JOB | 10 | ₹60 |
| 4 | Taking down Runway light fitting and isolation transformer of an any type from CI Boxes ,dewatering and cleaning of CI boxes using non corrosive methods complete all as directed by Engineer-in-Charge. | 50 | EACH JOB | 10 | ₹500 |
| 5 | Material and Labour, in replacement of outdoor type end termination joint of size 6 sq mm to 50 sq mm, making new terminations using lugs/ferrule/thimbles and insulating the same by PVC sleeves, insulation tape of any volt grade suitable for end termination with single core suitable for AFLC/LT cables complete along with jointing material all as specified and as directed | 12 | EACH JOB | 10 | ₹120 |
| 6 | Material and labour for replacement of outdoor type Straight through ,jointing kit, heat shrinkable for 1100 volt grade for runway cable AFLC/LT UG cable, single conductor complete along with jointing material PVC sleeves, insulation tape for AFLC cables complete all as specified and as directed of size size10 to 50 Sq mm. | 10 | EACH JOB | 10 | ₹100 |
| 7 | Material and labour for cutting road up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by filling with PCC type C2(1:3:6) by using 40mm graded stone aggregate for laying the pipes / laying cables, etc., complete all as directed by the Engr-in-Charge. | 2 | CUBIC METRE | 11 | ₹22 |
| 8 | Disconnecting & Removing the unserviceable GODO horizontal / vertical of any capacity of and any volt grade from the Two/four pole / six pole structure carefully and repair/maint and servicing of GODO by greasing to Male, female contacts, and reconnecting the earth wire with the structure and replace the nut, bolt and washers complete all as specified.
Note: Cost of Jumper connections along with fixing materials shall deemed to be included in the unit rate. | 2 | EACH JOB | 12 | ₹24 |
| 9 | Material and labour for maintenance of the copper earthing of any type and size at scattered area, pouring water, adding salt solution on required intervals to maintain earth resistance within permissible limit taking reference with concern section up to contract period completion, submitting individual earth resistance & E-N values of eqpt results twice in maint period and carrying out earth test resistance of individual earth along with E-N values of connected eqpt as and when demanded by MES with in 48 hours subject to rectifying the defects in all respects up to obtain the permissible values all as specified and directed. | 150 | EACH JOB | 13 | ₹1,950 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender8271.pdf
Tender Documents • 0.92 MB
BOQ_896728.xls
BOQ • 18.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .