Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 CrAccepted-AOC | ₹16.4 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹16.5 CrRejected-AOC | ₹16.5 Cr | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹18.6 CrRejected-Finance KANNUR | KERALA | 670001 | ₹18.6 Cr | L3 | Rejected-Finance L3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful |
| Sl No | Description | Qty | Unit | THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY L3 | VELLAPALLY BROTHERS L2 | SMARD L1 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS EARTHWORK | ||||||
| 1.01 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 221.68 | cum | 191 ₹42,340.12 | 450 ₹99,754.20 | 205 ₹45,443.58 |
| 1.02 | 2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock | 4,342.09 | cum | 511 ₹22.2 L | 650 ₹28.2 L | 398 ₹17.3 L |
| 1.03 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 68.51 | cum | 264 ₹18,086.11 | 500 ₹34,254 | 285 ₹19,524.78 |
| 1.04 | 2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock | 436.73 | cum | 650 ₹2.8 L | 700 ₹3.1 L | 506 ₹2.2 L |
| 1.05 | 2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock | 204.92 | cum | 197 ₹40,369.44 | 100 ₹20,492.10 | 183 ₹37,500.54 |
| 1.06 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 3,041.36 | cum | 318 ₹9.7 L | 350 ₹10.6 L | 248 ₹7.5 L |
| 1.07 | Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge. | 2,027.57 | cum | 219 ₹4.4 L | 375 ₹7.6 L | 312 ₹6.3 L |
| 1.08 | Conveying and depositing surplus earth for every additional 1Km lead and part thereof including loading and unloading as directed by Engineer- in-Charge. | 1,500 | cum | 30 ₹45,000 | 50 ₹75,000 | 325 ₹4.9 L |
| 1.09 | 50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | 172.67 | cum | 648 ₹1.1 L | 1,351 ₹2.3 L | 504 ₹87,025.68 |
Tender Value
₹16.2 Cr
EMD Value
₹5 L
Closing Date
26 Jun 2025, 3:00 pmClosed
Managing Director, INKEL Limited
1st Floor, Ajiyal Complex, Kakkanad - 682030
Civil and MEP Works
2025_INKEL_766773_1
NIT/INKEL/NHM/2025-26/347 Dated 28/05/2025
Open Tender
Civil Works - Buildings
450 days
Government Medical College
As per Tender Document
21 documents required · 21 mandatory
₹17,700
₹5 L
Yes
INKEL Limited
16 Sept 2025
28 May 2025
27 Jun 2025
29 May 2025
26 Jun 2025
12 Jun 2025
4 Jun 2025
Amount
CIVIL WORKS EARTHWORK
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge.
Conveying and depositing surplus earth for every additional 1Km lead and part thereof including loading and unloading as directed by Engineer- in-Charge.
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
Providing and applying Anti-termite treatment by injecting chemical emulsion Imidacloprid 30.5%SC at a concentration 5 litres per sqm or as per manufacturers recommendation for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Providing and laying 110mm( 6kg/cm2) dia slotted pipe with all fittings in 20mm Aggregate filling behind thr retaining wall(Filling shall be measured under item concerned)
Supplying and packing of 20 to 75mm graded aggregate as per IS code 383-1970 between the retaining wall and earth fill along the building perimeter including watering, ramming, consolidating and dressing complete including lead, lift, stacking, transportation etc. as directed by the Engineer in charge - for retaining wall
PCC WORKS
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
RCC WORKS
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All wiork upto plinth level
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note :- Cement content considered in M-30 is @ 340 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work above plinth level upto floor V level
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.
Providing and fixing at all level precast cement concrete in slabs,kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
STEEL REINFORCEMENT WORKS
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
JOINERY WORKS
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade II Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
Providing and fixing 12mm thick WPC partitions having density 0.7gm/cm2, tensile modulus 786 Mpa, water absorption 0.03% for 2hrs & 0.19% for 24hrs ,moisture content 0.08% confirming IS:2380 fixed in to aluminum frame work with C.P. brass / stainless steel screws for panelling works etc. complete as per architectural drawings and directions of engineer in- charge.(Aluminum frame work will be measured separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass of 6mm thickness.
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
Providing and fixing roller for Aluminium sliding door.
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Supplying and fixing 100mm mortice cylinder lock for aluminium door with following specification. a)Hook bolt has to be made of MS and SS for end plate and strike plate with lock set of size minimum 37mm, back set of min 20mm and hock bolt of min 18mm. b)Cylinder should be made of brass with minimum weight 0.20kg with nickel plated brass key(3 sets) and it should be of 5pin brass tumbler mechanism
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1500mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm and sandwiching with Honey comb insulation material. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1200mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm and sandwiching with Honey comb insulation material.. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors.
Supply, installation, testing and commissioning of 600mmx1500mm door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 1.2 mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.6 mm thick GI sheet and sandwiching with Honey comb insulation material. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge.
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with self tabs. Frames to have in-build grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff. Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door handle. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf..All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recommended by the manufacturer or engineer. Shaft door os size 600mmX1500mm
Curtain Track-Providing and fixing aluminium curtain track as per following specification.The track shall be made out of Aluminium alloy ( 6063-T6) with all Corner of profile having radius of 50mm,tensile Strength of 195 MPA, and a shear strength of 150 MPA. The Shape and Size tolerance shall be in accordance with IS 733- 1983. All materials shall be ROHS compliant with Corrosion resistance properties.The track shall be 50-60 micron Standard traffic white powder coated (Mahacoat) with seven stage processes. The Tracks shall have drill guide on the top. Track Gauge - 1.5 mm to 1.6 mm , 3.44 mm on top Profile Size 27mm x 20.4mm, HD Deralin Roller with SS 302 Hooks. The roof clamps shall be made out of aluminum pipe of 12.7 - 12.9mm diameter. The Upper Circular Plate shall be made out of aluminum with a diameter of 50.4mm.The outer surfacce shall be powder coated to approved finish and colour. The track shall be ceiling suspended using anchors, bolts, screws etc. Wall Supports & Bridge Clamps shall be aluminum powder coated to approved Curtain colour and finish. Removal Point shall be made out of mild steel with Zinc for simple loading & unloading of curtains.
Curtain cloth-Providing and installation of hospital curtains with the following specifications. The curtians shall be Premium Quality Fabric Curtains:Stain Retardant Fabric with matching color 450mm oval net on top. Complete with SS grommets.
BLOCKWORK
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
6.4.2 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
60.6 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.
FLOORING WORKS AND WATERPROOFING WORKS
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600mm.
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and applying 2mm epoxy screed 1000 micron on concrete floors after the surface preparation & application of epoxy priming coat including application of epoxy self levelling floor topping over the cured epoxy screed. The surface preparation shall include dry grinding of existing concrete surface of floor with diamond wheel grinder followed by cleaning with wire brushing etc . A coat of low viscous epoxy primer 200 microns shall be applied over prepared surface by using brush/roller sufficiently covering the prepared surface.The screed shall be laid with the help of serrated trowels and spike rollers to ensure uniform level and no air entrapment.Epoxy floor topping shall be solvent free, resin rich ,non toxic,self levelling , pure liquid epoxy poly urethane resin flooring compound which shall be spread over the cured epoxy screed by serrated trowels/spiked rollers .The cost shall include materials , labours including treatment of construction joint filling etc complete as per the direction of engineer in charge.
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.
Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps, etc., in required design and pattern wherever require, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1cement : 3 coarse sand) laid and fixing with chemical adhesive,including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-charge.a. 18mm thick Granite of any colour and shade
11.20.2 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% white cement 50 % Grey cement
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying reinforced cement concrete in retaining walls, return walls, walls ( any thickness) inluding attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
14.91.1 : Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25 degree, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 degree as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150 degree. Cold flexibility shall be upto -2degree when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
22.14.1 : Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Terrace waterproofing: Providing and applying water proofing treatment to Terrace with Polymer Modified waterproofing system, Brushbond (Two part) After thorough surface preparation, Sealing for floor cracks, sealing honeycombs and sealing of floor to wall joints and Pressure grouting the leakage areas etc...With non-shrink cement mortar and saturating the surface, and brush applying two coats etc complete as per the direction of engineer in charge etc complete as per the direction of engineer in charge
FALSE CEILING WORKS
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross & of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main at 600 mm center to center to form a grid of 1200x600 mm and secondary cross of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm dip; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Aluminium Non perforated false ceiling - Providing &Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance > 60%.Tiles should have fire performance of Class A2-s1.d0 as per EN13501.The grade of aluminiumshall mandatorily be AA 3003.The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand.The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers.The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturer installation instructions and as directed by the Engineer-in-Charge.
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
STEEL WORK
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover
10.7 : Providing and fixing ball bearing for rolling shutters.
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10.00 sqm and upto 16.80 sqm in the area
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
FINISHING WORKS
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.12 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand )and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand) finished rough with sponge.
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
ROOFING WORKS
160mm uPVC for Rain Water Gutter with Leaf Guard - Supply, Installation, Testing and commissioning of 160mm uPVC Rain water gutter with Leaf Guard for Truss roof, including different types of fittings, required clamps and accessories. Gutters and fittings are specially designed to meet the requirements of all types of sloped roofs buildings. The system is provided with specially designed rubber gasket/seals to give totally leak proof joints to install with brackets and clamp complete.
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment and weight not less than 2400gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in charge
External Works
16.78.2 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
4.6.1 : Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)
PUBLIC HEALTH ENGINEERING SANITARY FIXTURES, BATH FITTINGS AND ACCESSORIES
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing sanitary fixtures for handicapped toilet including one number White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, overall size 660 x 375 x 760mm. or as per approved model and shape,including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc.complete, wash basin, one pair mounting brackets, one number elbow operated pillar cock 3.8 LPM @ 3 Bar and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc., designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
17.23 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
17.75 : Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms.
17.76.1 : Providing and fixing PTMT urinal cock of approved quality and colour.15 mm nominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms .
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps
17.7.9 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
Providing and fixing of Black colour Poly Propylene Laboratory Sink, Dimensions: external 558 x 355 x 240mm, Net weight: 2.7 kg, Temperature range: 0-80°C, 1/2” BSP Waste connection, Net weight: 0.2 kg Dimensions: Ø73, 1½” BSP with PTMT/PP waste coupling, adjustable screw on nut. , including cutting and making good the walls wherever required: Polypropylene Laboratory Sink without drain board
17.10.1.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 200 mm
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Mixer with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flanges and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.
Providing and fixing CP Wall Mounted type Sink Tap complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.
18.22.1 : Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
17.28.2.1 : Flexible pipe32 mm dia
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
Providing and fixing of C. P. Robe Hook, 60mm. Dia. x 45mm. High.
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing cooler (hot, cold and normal water) with inbuild RO filter including cost and conveyance of all materials labour charges etc. complete, including necessary wall cutting / chasing and making good as required etc. complete, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-In charge at all levels. Flow Rate - 125 Ltrs / Hr, Processing Tank Capacity - 17 Ltrs, Storage tank Capacity / Ltrs (Normal, Hot & Cold) - 40 Ltrs Normal, 4 Ltrs Hot & 40 Ltrs Cold.
Providing and fixing of Slop Hopper with Pressing valve 304G Stainless Steel, Conical flushing bowl with continues flushing rim having whirl effect, P / S trap for drainage, Health faucet Dimension :24”L x 24”W x 35”H"
INTERNAL DRAINAGE
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.7.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).110mm OD
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).75mm OD
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.63 mm dia 4 Kgf/cm2 Internal work - Exposed on wall
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails (2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts .G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts.G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 '' STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails (2.5 mm thick) or Clamping with Universal clamps, Anchor fastners (10mm),Threaded Rod(10mm), nuts, washers etc complete.160mm OD
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete.110mm OD
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.
Providing and Fixing C.P. brass or stainless steel(SS-304) Square Flat cut single piece Gratings size 125x125 mm. Gratings for 110mm. Floor Traps.
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 110mm
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 75mm
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
WATER SUPPLY
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft-65 mm nominal outer dia. Pipes
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 15mm. (1/2")
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
18.19.3.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal bore Vertical
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4 "(20mm) dia
Supplying, Installing & Testing at site in position Brass Float valve (PN 10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 40mm dia (1 ½”)
CI Y Strainer 1 1/4” (32mm) dia - Supply, Installation, Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects
CI Y Strainer 2 ½” (65mm) dia -Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects
Terrace / Ceiling shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self-Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 32 mm. dia. (1 1/4") pipe
Terrace / Ceiling shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self-Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 25 mm. dia. (1") pipe
Terrace / Ceiling shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self-Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 20 mm. dia. (3/4") pipe
EXTERNAL SEWERAGE AND STORM WATER DRAIN
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.<br>External work (Including excavation)<br>40 mm nominal outer dia Pipes
50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
Supply,installation, testing and commissioning of stainless steel Bar Screen (opening 15mm) suitable for screen mesh of size 500mmx500mm removable type Screen Member 10mm S.S. Grade 316S Rods in Vertical Pattern.
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external work. Sub analysis item for sand filling component
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
CIVIL WORK FOR RCC MANHOLE
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
600 X 900 mm (24" X 36") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover with frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover with frame Light Duty (2.5 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124
MISCELLANEOUS ITEMS
PLUMBING PUMPS
SITC of WASTE WATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps high efficiency electrical motors, One working + Cyclically stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications (Sullage Transfer from pumping station to STP)<br>Without joint Cable length all Cutter Pumps shall be 10 Mtr.Minimum <br>Capacity: 3LPS @ 15Mtr. Head, 3Ph, Complete Set
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage pump set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 1.88lps @ 21mtr head, Head range 14 to 38 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation
SITC of SEWAGE WATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps high efficiency electrical motors, One working + Cyclically stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications (Sewage Transfer from pumping station to STP)<br>Without joint Cable length all Cutter Pumps shall be 10 Mtr. Minimum<br>Capacity: 2.5LPS @ 15Mtr. Head, 3Ph, Complete Set
Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication (Modbus). Type: Thermostatic Controlled. Horizontal,multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft,impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility.<br>Flow for each pump in LPS : 2<br>Head in mtr : 10<br>Head Range : 5 - 15 mtr<br>MOC : SS 304 Impeller<br>Total no of pump: 1 SET ( 1Working + 1Standby)
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS-316 storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. 1000 LPD, consisting of Solar Hot Water Panels of Aggregate Capacity: 500 LPD (50% of the total requirement), 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 1000 Litre, Heat pump Rated hot Water (200 to 220L/h) COP of Heat pump 4.2, Including of the Circulation Pumps if required between heat pump/Panels and storage tank, control panel.Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation. Electrical Work from Pump panel to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., complete.
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
ELECTRICAL WORKS WIRING AND ACCESSORIES
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 16 amps modular socket outlet and 16 amps modular switch, connection etc. as required.
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
DISTRIBUTION BOARDS
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supplying and fixing 16A to 100A TM FP MCCB 25KA in the existing Vertical DB complete with connections,testing and commissioning etc. as required
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A 4P 100mA RCCB
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25/32 amps
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
CABLE TRAY AND ACCESSORIES
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.1.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness
4.2.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required225 mm width X 50 mm depth X 1.6 mm thickness
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness
4.2.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required450 mm width X 50 mm depth X 2.0 mm thickness
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.3.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.3.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.5.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
HT & LT CABLES AND TERMINATION
90.12.1.35 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 core 240 sq mm
90.12.2.35 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 3.5 core 240 sq mm
90.12.5.35 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 50 sq mm with factory made clamp
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 240 sq mm
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 6 sq mm with factory made clamp
Supply and laying of the following size 1.1kV grade XLPE insulated PVC sheathed, Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 1Cx16sq.mm CU flexible Cable
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 16 sq mm
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
PANELS AND ACCESSORIES
Main Panel (SMDB -8WAY):- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 8 way complying to IEC 61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters ; indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer ;1 No. 630A 36kA FP MCCB, Outgoings: - 1 No 200A 25KA TP MCCB, 3 No 80A 25KA TP MCCB ,4 Nos 63A 25KA TP MCCB.
SSB LIGHT AND POWER:-SMDB 8 WAY :- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 8 way complying to IEC 61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters ; indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer:1 No. 200A 25kA FP MCCB, Outgoings: - 2 No 80A 25KA TP MCCB, 3 Nos 63A 25KA TP MCCB,2 Nos 50A 25KA TP MCCB, 1 No 32A 25KA TP MCCB
HVAC OUTDOOR PANEL- SMDB 4 WAY :- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IEC 61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters ; indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer ;1 No. 50A 25kA FP MCCB, Outgoings: -4 No 32A 25KA TP MCCB
UTILITY PANEL:-SMDB 4 WAY :- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IEC 61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters ; indicating lamps, Aluminum bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer ;1 No. 80A 25kA FP MCCB, Outgoings: -2 No 63A 25KA TP MCCB, 2 No 40A 25KA TP MCCB
LIFT PANEL(TYP) (SMDB-4WAY):-Supply, Installation, Testing and commissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IEC 61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters ; indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed a per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge.Incomer ; a)1 No 40A TPN ISOLATOR Outgoings: -a) 1 Nos 40A, 4P 100mA RCBO b) 1Nos 25A, DP 30mA RCBO c) 4 Nos 6A, SP MCB.
SDB - LIFT PANEL (SMDB -4WAY):- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IEC61439 Part 1 ; 2. The Enclosure shall be IP42 with cable end box, cable alley,pre wired meter chamber with all meters ; indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge.Incomer ;1 No. 80A 25kA FP MCCB Outgoings: - 4 Nos 63A, 25KA TP, MCCB
SUPPLY AND FIXING OF LIGHT FIXTURES
SITC of 2x 2 LED Recess mounted 21W light fixture, system efficacy 120 lm/W and system lumen output not less than 2600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor =0.95, THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19, SDCM ;5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor ; 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
SITC of LED recessed downlight fixture Maximum 14W(+/- 10% Tolerance) light fixture. System efficacy 110 lm/W and system lumen output not less than 1500 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor =0.95,THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19,SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire /Drive shall be BIS approved of same make
SITC of LED recessed downlight fixture Maximum 11W(+/- 10% Tolerance) light fixture. System efficacy 110 lm/W and system lumen output not less than 1200 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor =0.95,THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19,SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire /Drive shall be BIS approved of same make
SITC of of LED Tube Lights of 20W(+/- 10% Tolerance) with minimum system lumens 2200 Lumens Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection inbuilt with electronic drive system, , SDCM ;5 and CCT in between 4000K to 5700K,power factor = 0.95, THD ;10%,rated life of 50,000 hours at L70, system efficacy 110 lm/W, with a CRI 80, or above, Luminaire shall be flicker free with ripple factor ; 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
SITC of 2x 2 LED Recess mounted 30W light fixture, system efficacy 110 lm/W and system lumen output not less than 3300 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor =0.95, THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;22, SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple factor ; 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.
SITC of LED surface mounted downlight fixture Maximum 11W(+/- 10% Tolerance) light fixture. System efficacy 110 lm/W and system lumen output not less than 1200 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor =0.95,THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19,SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire /Drive shall be BIS approved of same.
SITC of LED surface mounted downlight fixture Maximum 14W(+/- 10% Tolerance) light fixture. System efficacy 110 lm/W and system lumen output not less than 1500 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor =0.95,THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19,SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire /Drive shall be BIS approved of same make
SITC of LED surface mounted downlight fixture Maximum 18W(+/- 10% Tolerance) light fixture. System efficacy 110 lm/W and system lumen output not less than 2000 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor =0.95,THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19,SDCM ;5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire /Drive shall be BIS approved of same make
SITC of 2x 2 LED surface mounted 21W light fixture, system efficacy 120 lm/W and system lumen output not less than 2600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor =0.95, THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19, SDCM ;5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor ; 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
SITC of 2x 2 LED surface mounted 30W light fixture, system efficacy 120 lm/W and system lumen output not less than 3600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor =0.95, THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, UGR ;19, SDCM ;5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor ; 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make
SITC of LED Mirror Lights of Maximum 10W light fixture, System efficacy =100 lm/W and system lumen output not less than 1000 lm. driver with minimum 2.5KV internal surge protection with electronic drive system, power factor =0.95, THD ;=20%, rated life of 50,000 hours at L70 with a CRI 80, SDCM ;5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided andincluding connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy =100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor 0.95, THD ;10%, rated life of 50,000 hours at L70 with a CRI 80, SDCM ;5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate ; BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply of 450 mm sweep, 900 rpm Heavy Duty Exhaust fan working on 230 V A/C in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as required for complete installation etc complete as required
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
EARTHING
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required (12 SWG)
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required ( 10 SWG)
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. (12 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. (10 SWG)
LIGHTNING PROTECTION
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3:For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod:For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal .Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination; Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 ; 8 meter air terminalfor mounting: tripod stand or 3 nos ; 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. a) 2 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories.
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod:For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered.For 6 ; 8 meter air terminalfor mounting: tripod stand or 3 nos ; 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.b) 4 meter air terminal with Interception Tip mounted on Concrete Stone ; Stainless Steel mounting accessories.
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 ; 8 meter air terminal for mounting: tripod stand or 3 nos ; 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. b)3 meter air terminal with Interception Tip mounted on Concrete Stone ; Stainless Steel mounting accessories
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load.All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 ; 8 meter air terminal for mounting: tripod stand or 3 nos ; 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. c) 4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories
Providing and fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5)with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.c) Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters.
Providing and fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5)with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. b) Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters
Providing and fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5)with 50 sq.mm cross sectional area.Govt approved Indian labs test certificate required. a) Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters
Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required.
Providing and fixing of Stainless Steel Test Joint suitable with with SS bottom plate arrangement for inspection without removing conductor with an isolating clamp arrangement for Aluminium and earth conductor mounted inside a test link box having minimum internal dimensions 110*110*67. The test link has to be straight and needs inimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium ; 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required.
Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.
Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required.
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg ; bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg ; bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required.
MISCELLANEOUS ITEMS
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and providing 4mm thick MS chequered plates duly painted. Plates to be cut size and welded with necessary angle iron supports as per site requirement.
Supply and providing 2/3 mm thick and 1 m wide electrical grade chequered type elastomeric mat to withstand 3.3 kV dielectric strength conforming to IS 15652:2006
Supply, fabrication and fixing 3 nos MS Fire buckets on suitable fabricated MS angle iron stand with hook, painting with red paint ; filled with dry sand as required with all required accessories.
Supply of Co2 type Fire Extinguisher 4.5 Kgs Capacity, made from brand new seamless steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge as per IS: 15683-2006 specification, bearing ISI Mark.
Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Supplying and Providing 15" long rubber hand gloves
Supply and providing First Aid Box.
40KVA Modular(N+1) UPS:-Supply, installation, and commissioning of MODUALAR UPS 1X60kW or nearest higher size Frame with maximum 20kVA units or nearest standard rating in each frame of 3 phase modules three phase in and out and indoor (IP20) with surge protection system and battery sizing calculation to be provided from the OEM, with isolator for each bank battery of reputed approved make , Input pf 0.99, Input THDi ; 3%, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic noise at 1m of the system should be ;80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, IEC62040-4 or ISO14025 or equivalent relevant IS standard. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic ; manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. Battery backup time required is 15 Min. using external SMF batteries. ;
ISOLATORS
SITC of MCB Isolator in (W/P) Enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 25A 4P MCB Isolator (W/P)
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 63A 4P MCB Isolator
LIFT WORKS Passenger Lift
FIRE WORKS HYDRANT AND SPRINKLER SYSTEM
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 150mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 100mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : Dia - 80mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 65mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 50mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 40mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 32mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 25mm
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia.
Providing laying, testing & commissioning of class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation &amp; providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of size complete as required: 150 mm dia
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 150mm
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 100mm
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 80mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Pendant sprinkler.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright sprinkler.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Horizontal side wall sprinkler.
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.1200mm.
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center racket, stockbar of following sizes complete as required.1000 mm length with all connecting system and accessories.
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.700mm.
Supply,installing, testing and commissioning of Flow switch on sprinkler distribution header on each floor and shall be connected to Fire alarm panel through cable
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including isolation valve and necessary accessories and connections.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required&l4 way - 150 mm dia M.S. Pipe
Supply and Fixing of weather proof Hose cabinet suitable size & having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses, and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside.
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 30 m
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.
Addressable alarm system
Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish.
Supply and laying of 2X1.5 SQMM Flexible Stranded bare copper Conductor ,PVC Insulated (FRLS) Fire Alarm Cable
Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling
Supply, Installation, Testing & Commissioning of Addressable Monitor Module
Supply, Installation, Testing & Commissioning of Addressable Control Module
Supply, Installation, Testing & Commissioning of Fault Isolator Module
Supply, Installation, Testing & Commissioning of Addressable Multi Detector with Base.
Supply, Installation, Testing & Commissioning of Addressable Smoke Detector with base.
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point (Resettable type).
Supply, Installation, Testing & Commissioning of Addressable Horn & Strobe (Sounder with Flasher) for Audible Annunciation & Visual Indication.
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (MCP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display with Battery Back up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panel shall work in a flash scan protocol and shall be networked together and capable of networking with other compatible panels. The Panel shall have 4 Loop Capacity and shall be expandable up to 5 Loop, all as per Technical Specifications.
PA TALKBACK
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Green / Blue Colour / Finish, as per Technical Specifications. (Approx. Quantity for Networking)
Supply,installation,testing and commisioning of Public Address speaker with talk back facility 6 Watts with LMT and call switch, made out of powder coated CRC A sheet ,wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.
SIGNAGES
Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing Directional signboards made of luminescent safety ,rigid sheet in green colour, photoluminescent type Samples has to be approved by the Engineer in charge before procuring the same and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing Manual call point signboards made of luminescent safety ,rigid sheet in green colour, photoluminescent type Samples has to be approved by the Engineer in charge before procuring the same and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing Floor Identification signboards made of luminescent safety ,rigid sheet in green colour, photoluminescent type Samples has to be approved by the Engineer in charge before procuring the same and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing FIRE EXIT signboards made of luminescent safety ,rigid sheet in green colour, photoluminescent type Samples has to be approved by the Engineer in charge before procuring the same and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing Signage with printed FIRE CABINET of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts and shall be as per IS code 9457:2005, IS 12349, IS 12407.
Providing and installation in position self glowing Signage with printed FIRE EXTINGUISHER of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts and shall be as per IS code 9457:2005, IS 12349, IS 12407.
EXTINGUISHER
Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark
Supply and installation of Fire Extinguisher, Carbon di-oxide type capacity 4.5 Kg with provision of wall bracket (fixed with anchor fastener) or floor mounted ISI marked (IS:2878) Flat base including valve,discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension
Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy & powder coated as per IS: 5 Color Shade No. 538 (For Server room) 5 Kgs
ADDITIONAL WORKS
FIRE SEALANT for Fire and ELV Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57:Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. <1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemicalanchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose
MEDICAL GAS PIPELINE SYSTEM
SITC of Oxygen Flowmeters with humidifier bottle
Ward Vacuum Units
Theatre Vacuum Units
SITC of ICU Terminal Units - Imported - O2
SITC of ICU Terminal Units - Imported - Air
SITC of ICU Terminal Units - Imported - VAC
SITC of Ward Terminal Units - Indigenous - O2
SITC of Ward Terminal Units - Indigenous - Vac
SITC of Matching Probe - O2
SITC of Matching Probe - Air
SITC of Matching Probe - VAC
SITC of Area Valve Service Units with Alarm Systems - 6 Services
SITC of Area Valve Service Units with Alarm Systems - 4 Services
SITC of Area Valve Service Units with Alarm Systems - 2 Services
SITC of Copper pipe - per mtr. - 12mm
SITC of Copper pipe - per mtr. - 15mm
SITC of Copper pipe - per mtr. - 22mm
SITC of Copper pipe - per mtr. - 28mm
SITC of Copper pipe - per mtr. - 35mm
SITC of Copper pipe - per mtr. - 42mm
SITC of Ball Valves - 15mm
SITC of Ball Valves - 22mm
SITC of Ball Valves - 28mm
SITC of Ball Valves - 35mm
SITC of Ball Valves - 42mm
SITC of Bed Head Units - 1000 mm for Wards
SITC of Bed Head Units - 1500 mm for ICU Category.
Interconnecting charges from existing unit
Interconnecting MGPS pipelines from the existing MGPS plant room to the new building including the steel structural work to get a clear height of 6m from ground with proper coving to MGPS line and a proper RCC foundation without affecting the existing facility at hospital all as per the approval from Site in-charge. Before execution proper structural design (Analytical Models, Design calculations for connection design & foundation) with detailed drawings for the super structure and foundation should be submitted and get it approved from Structural Engineer as directed by the Site-in-charge.
HVAC WORKS
Supply Installation, Testing & Commissioning of Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter Compressors, minimum two compressors for above 14 HP modules, microprocessor-based Controller,top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, necessary power cable from isolator to ODU, with suitable foundation etc. complete as required. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .The efficiency of the equipment shall meet ECBC+ latest standards. Motor shall be minimum IE 3 rated as per IS 12615. Capacity - 16 HP.
Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, conduit accessories and necessary fixing arrangement., Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 2.5 TR VRV INDOOR UNIT UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts.
Supply,Installation and commissioning of copper refnet joint with insulation , all necessary support and accessories.
Supply, installation, testing and commissioning, of Transmission/Communication cabling, of 2 core 1.5 Sqmm shelied cable for interconnecting the Indoor and Outdoor Units of all the VRV/VRF Units for proper performance , Communication cable must be routed throgh PVC pipe.
Supply, Installation, Testing and commissioning of factory built Ceiling Suspended double skin VRF compactable AIR-HANDLING UNIT inculding AHU kit units made of 50 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6mm outside layer and 0.6mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, thermal break profile,cooling coil section with aluminium finned copper tubes cooling coil, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, fine filter, mixing box, supply air damper, return air damper,fresh air damper, plug fan with variable frequency drive suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, IE3 motor, drain connections,necessary starter panel with bypass arrangement and power cable. 3.0 TR, 600 cfm, 6 row coil Ceiling suspended unit with Fine filter, mixing box and 3 x 0.5 KW heaters.
Supply, Installation, Testing and commissioning of factory built Floor Mounted double skin VRF compactable AIR-HANDLING UNIT including AHU kit units made of 50 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6mm outside layer and 0.6mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection molding machine, thermal break profile,cooling coil section with aluminium finned copper tubes cooling coil, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, fine filter, mixing box, supply air damper, return air damper,fresh air damper, plug fan with variable frequency drive suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, IE3 motor, drain connections,necessary starter panel with bypass arrangement and power cable.10.0 TR, 4000 cfm, 6 row coil Floor Mounted unit with Fine filter and Mixing box.
Supply, Installation, Testing and commissioning of factory built Floor Mounted double skin VRF compactable AIR-HANDLING UNIT including AHU kit units made of 50 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6mm outside layer and 0.6mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, thermal break profile,cooling coil section with aluminium finned copper tubes cooling coil, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, fine filter, mixing box, supply air damper, return air damper,fresh air damper, plug fan with variable frequency drive suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, Bypass Starter, IE3 motor, drain connections,necessary starter panel with bypass arrangement and power cable. 8.0 TR, 3200 cfm 6 row coil Floor Mounted unit with Fine filter
Liquid line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth & foaster painting.
Suction line - Refrigerant piping with 19 mm thick nitrile rubber insulation and with glass cloth & foaster painting.
Supply, Installation, testing and commissioning of air cooled INVERTER TYPE Compressor split Airconditioners each complete with scroll compressor, air cooled condenser, GSS casing, filters, cooling coils, fan motors,insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including Micro- processor control with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipment's requirements with micro-processor control panel for each machine. GI painted frame works for outdoor units & making good of civil work's. Refrigerant shall be R410/R32. Price shall inclusive of all duties, installation, commissioning, Refrigerant piping upto a standard length of 3 meter and above 3 meter shall be measured separately.All Indoor Units shall be factory assembled, wired, piped and tested. Indoor units shall have provision for connecting Fresh Air Ducts. All Units shall be controlled by Electronic Expansion Valves only. All Units mounted inside the Ceiling shall have Fans capable of sustaining Duct connections, and special Filters if necessary. Indoor units to be slim type,medium static units. Pre-filters to be part of all indoor units and all units shall be low db units. The indoor units should including the cordless remotes, refnet joints, control cabling between indoor & out door units.Capacity minimum of 3.5 TR INVERTER TYPE 4 WAY CASSETTE SPLIT UNIT 4 STAR RATED AS PER BEE.
Supply, Installation, testing and commissioning of air cooled INVERTER TYPE Compressor split Airconditioners each complete with scroll compressor, air cooled condenser, GSS casing, filters, cooling coils, fan motors,insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including Micro- processor control with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with micro-processor control panel for each machine. GI painted frame works for outdoor units & making good of civil work's. Refrigerant shall be R410/R32. Price shall inclusive of all duties, installation, commissioning, Refrigerant piping upto a standard length of 3 meter and above 3 meter shall be measured separately.All Indoor Units shall be factory assembled, wired, piped and tested. Indoor units shall have provision for connecting Fresh Air Ducts. All Units shall be controlled by Electronic Expansion Valves only. All Units mounted inside the Ceiling shall have Fans capable of sustaining Duct connections, and special Filters if necessary. Indoor units to be slim type, medium static units. Pre-filters to be part of all indoor units and all units shall be low db units. The indoor units should including the cordless remotes, refnet joints, control cabling between indoor & out door units. Capacity minimum of 2 TR INVERTER TYPE DUCTABLE SPLIT UNIT 4 STAR RATED AS PER BEE.
Supply, Installation, testing and commissioning of air cooled INVERTER TYPE Compressor split Airconditioners each complete with scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including Micro- processor control with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with micro-processor control panel for each machine. GI painted frame works for outdoor units & making good of civil work's. Refrigerant shall be R410/R32. Price shall inclusive of all duties, installation, commissioning, Refrigerant piping upto a standard length of 3 meter and above 3 meter shall be measured separately.All Indoor Units shall be factory assembled, wired, piped and tested. Indoor units shall have provision for connecting Fresh Air Ducts. All Units shall be controlled by Electronic Expansion Valves only. All Units mounted inside the Ceiling shall have Fans capable of sustaining Duct connections, and special Filters if necessary. Indoor units to be slim type,medium static units. Pre-filters to be part of all indoor units and all units shall be low db units. The indoor units should including the cordless remotes, refnet joints, control cabling between indoor & out door units. Capacity minimum of 2 TR INVERTER SPLIT UNIT 4 STAR RATED AS PER BEE
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-600 CFM exhaust blower with Hepa filter [Isolation rooms].
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1700 cfm Exhaust Blower
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1350 cfm Exhaust blower
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 150 cfm Exhaust blower
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 100 cfm Exhaust blower.
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 80 cfm Exhaust blower.
Drain Piping :Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe from terminal units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation - 25 MM Dia
Drain Piping: Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe from terminal units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation - 32 MM Dia
Drain Piping:Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe from terminal units drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation - 40 MM Dia
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supply, handle and erect factory fabricated fresh air dampers with louvers and control lever as per the specification including all accessories required for complete installation as directed by engineer in charge.
Supply installing, testing and commissioning of (Factory Fabricated) HEPA filters of efficiency 99.9% down to 0.3 microns in filter plenum of 18 Gauge with rubber Gaskets In SS suitable frame work with 70% perforated grille [For isolation rooms]-[610x610x150 mm]
Supply & fixing of 25 mm or nearest thickness Class O nitrile rubber insulation with antimicrobial propertywith adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor or ‘’ value of the base insulation material shall be minimum 7,000, thermal conductivity shall be 0.035W/mk. R value of the insulation material shall comply with the ECBC + building standards.
Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3
UNDER DECK INSULATION - Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & microswitch to shut of corresponding AHU (including control cable.)
VELLAPALLY BROTHERS (BID ID -2233317)
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY (BID ID -2232695)
Bidder Name
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
VELLAPALLY BROTHERS
SMARD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid