Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 2 | Accepted-Technical 92 MARY VILLA WEST OTHERA OTHERA PATHANAMTHITTA KERALA 689551 | PATHANAMTHITTA | KERALA | 689551 | Accepted-Technical Technically Qualified |
| 3 | Accepted-Technical 24 234 2 NEAR VYDHYUTHI BHAVAN KOTTAPPURAM ROAD PUNKUNNAM THRISSUR KERALA 680002 | THRISSUR | KERALA | 680002 | Accepted-Technical Technically Qualified |
Tender Value
₹1.7 L
EMD Value
₹4,325
Closing Date
28 Jun 2026, 4:00 pmClosed
STEEL INDUSTRIALSKERALA LIMITED
STEEL INDUSTRIALS KERALA LTD.ATHANI P.O, THRISSUR- 680 581
Repair and Maintenance of High Mast/ Mini Mast Systems in various locations of Puthige Grama Panchayath, Kasaragod District under Annual Project 2025-26 - Project No.358
2026_SILK_856632_1
SILK/PED/S-19/2026-27/486
Open Tender
Miscellaneous Works
Item Rate
120 days
Puthige
As per the tender documents
6 documents required · 6 mandatory
₹590
₹4,325
Yes
18 Aug 2026
19 Jun 2026
29 Jun 2026
19 Jun 2026
28 Jun 2026
19 Jun 2026
19 Jun 2026 - 28 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical works | |||||
| 1.01 | OD400340/2025-2026
Supply and Installation of 100W LED Flood light output greater than 105lumen/W
4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power
factor greater than 0.95 at full load, internal surge protection up to 8 KV,and
Aluminium pressure die-cast Powder coated housing, acrylic cover complete with
THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up
for use on 230 V AC supply. Driver compartment should be seperatly accessible for
maintenance (2 years warranty for LED Flood Lights) | - | each | - | - |
| 1.02 | OD400366/2025-2026
Supply and Installation of 150W LED Flood light output greater than 105lumen/W
4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power
factor greater than 0.95 at full load, internal surge protection up to 8 KV, and
Aluminium pressure die-cast Powder coated housing, acrylic cover complete with
THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up
for use on 230 V AC supply. Driver compartment should be seperatly accessible for
maintenance (2 Years Warranty for LED Flood Lights) | - | each | - | - |
| 1.03 | OD405432/2025-2026
Supply and installation of dust and vermin proof, outdoor single Phase Polycarbonate/
FRP/PVC /UPVC Meter Box suitable to install KSEB meter, fuse units etc., as
required and including fixing it on Wall/ Angle iron Frame, making good, without the
damages color washing etc., as required.(Size 400 x 300 x 190) | - | each | - | - |
| 1.04 | OD405419/2025-2026
Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a
25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly
schedules, along with manual start, ON delay, and OFF delay settings. Equipped with
a high-precision, industrial-grade chip and strong anti-interference capabilities, the
timer can automatically turn on and off the power supply of various electrical
equipment according to the time set by the user. The controlled objects can include
street lights, light boxes, neon lights, and high/mini mast systems. It also includes a
sufficient battery backup for time memory in case of power failure, and comes with
suitable fittings for use in a distribution box or MV panel with FRLS PVC insulated .5
mm single core cable suitable for control wiring towards contactor | - | each | - | - |
| 1.05 | OD405427/2025-2026
Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz
operation. It can control street lights, light boxes, neon lights, high/mini mast systems,
and induction loads. | - | each | - | - |
| 1.06 | 2.10.3
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | - | each | - | - |
| 1.07 | OD405449/2025-2026
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5
sq. mm | - | metre | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
PROFILE.pdf
Additional Documents • 0.03 MB
GCC.pdf
Tender Documents • 0.42 MB
BOQ_1447890.xls
BOQ • 0.29 MB
856632c.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .