Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹18.0 L+₹1.8 L (11.2%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹18.3 L+₹2.1 L (13.0%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹18.5 L+₹2.3 L (14.1%)Accepted-Finance MAHAVEER NAGAR BARMER RAJASTHAN 344001 MAHAVEER NAGAR BARMER RAJASTHAN 344001 | BARMER | RAJASTHAN | 344001 | L4 | Accepted-Finance L4 | |
| 5 | L5₹19.5 L+₹3.3 L (20.3%)Accepted-Finance | L5 | Accepted-Finance L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Apr 2023, 6:00 pmClosed
GE (AF) NO 02 JODHPUR
GE (AF) NO 02 JODHPUR
REPAIRS TO ROOF TREATMENT IN CERTAIN BLDGS AND OTHER MISC B/R ITEMS AT DOMESTIC AREA UNDER AGE B/R-II, GE (AF) NO 02 JODHPUR
2023_MES_588034_1
8366/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) NO 02 JODHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) NO 02 JODHPUR
₹40,000
Yes
2 May 2023
1 Apr 2023
1 May 2023
1 Apr 2023
28 Apr 2023
15 Apr 2023
7 Apr 2023 - 14 Apr 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises as directed by Engineer-in-Charge.
Taking down existing roof treatment , cleaning of surface and removing all demolished material upto 5.00 Km as directed by Engineer-in-Charge.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in roof padding as directed by Engineer-in-Charge.
M&L10 mm thick screed bed with CM 1:4 with water proofing compound @ 3% by weight of cement finish even and smooth surfaces using without extra cement complete all as specified & directed. Note : Water proofing compound shall be measured and paid separately.
M&L for APP modified membrane minimum weighting 3 Kg/Sqm with polyster nonwoven polyester reinforcement (weight not less than 150 gms/sqm )shall be laid by torch application method and overlapped by 100 mm in all sides complete all as specified & as directed by Engr-in-Charge.
Supply only integral water proofing compound ISI marked.
M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specification:-(i) Cleaning of sunken floor surface with mechanical means i.e. wire brush/air blower etc. and remove all loose/unsound material dirt dust etc. (ii)Applying cement slurry mixed with acrylic based polymer modified cementitious composite compound coating Hydro proof Xtra of FOSROC /Equivalent of Dr Fixit of Pidilite industries Ltd in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four part of cement) (iiii) First layer of cement slurry @0.444 kg /sqm mixed with acrylic based modified cementitious composite compound @0.222 litre/sqm and allow it to air dry for 4 hour. (iv) Second layer of cement slurry @0.222 kg /sqm mixed with acrylic based defied cementitious composite compound @0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polythene film shall be pasted with help of adhesive over treatment. Note:- Joints of WC/Trap/Soil waste shall be properly sealed with sealing compound . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work as directed by Engineer-in-Charge.
M&L for plain cement concrete 1:5:10 type E-2 (using 20 mm graded broken bricks aggregate) as in foundation and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 32 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for light coloured vitrified ceramic tiles 10 mm thick area of each tiles not less than 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6 complete all as specified and as directed by Engineer-in-Charge.
All as per item no. 14.00 above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on stone masonry surfaces as complete all as specified and as directed by Engineer-in-Charge.
Cleaning and removing all scale dirt etc. from water storage tanks and from mouth of circulating pipes etc. and writing the date of cleaning and next due date for cleaning of tank, capacity of tanks exc. 250 liters and not exc. 500 liters complete all as specified and as directed
Cleaning and removing all scale dirt etc. from water storage tanks and from mouth of circulating pipes etc. and writing the date of cleaning and next due date for cleaning of tank, capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed.
Disconnecting existing tanks of any description exc. 250 ltrs and n.exc. 500 ltrs capacity and removing from site.
Disconnecting existing tanks of any description exc. 500 ltrs and n.exc. 1000 ltrs capacity and removing from site.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 15 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site.
Taking up or down steel tubing 20mm bore and connections including cleaning for refixing or removing from site complete all as specified and as directed by Engineer-in-Charge
Taking up or down steel tubing 25mm bore and connections including cleaning for refixing or removing from site complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 15mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed
Supply and laying 25mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
S&F in repairs 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms.)
S&F in repairs 15 mm bore bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F in repair brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union.
S&F in repair sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repair sink with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish.
S&F in repairs PVC valve less, symphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets.
S&F in repairs internal flushing cistern kit, washer, flushing handles etc. complete all as specified and as directed by Engineer-in-Charge
S&F grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs cast iron floor trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs cast iron nahani trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 75 mm bore cast iron bend (any radius) with duck’s foot or heel rest with oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
M&L in repair for vitreous china urinal flat back bowl type complete including providing and fixing plug size 465X355X265 mm white (minimum) with grating and union for discharge pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs lid for polyethylene water storage tank exc. 500 litres and n. exc 1000 litres including fixing PTMT nut/binding wire complete all as specified and directed.
M&L for Clear air lock from tank to kitchen, bath, WC and WHB by opening GI pipe/nipple, elbow, socket, union and other possible way etc. complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PVC waste pipe of 32 mm bore of suitable length for WHB/urinal/sink, complete all as specified.
M&L for repairs to leakage in existing 15 mm bore pipe line by providing elbow/union/socket/tank nipple/nipple up to 200 mm complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs to leakage in existing 20 mm bore pipe line by providing elbow/union/socket/tank nipple/nipple up to 200 mm complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs to leakage in existing 25 mm bore pipe line by providing elbow/union/socket/tank nipple/nipple up to 200 mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for center hole basin mixer or wall mixer.
S&F in repairs for sink mixer with regular spout w/m, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs for wall mixer with bend (Provision for O H Showe) complete all as specified and as directed by Engineer-in-Charge.
M&L for repairs to leakage of any type by providing M-Seal all as directed by Engineer-in-Charge.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F in repairs brass chromium plated health faucet of 15 mm bore complete all as specified and as directed by Engineer-in-Charge.
AAI NATH ENTERPRISES
JAMWAY MATA CONSTRUCTION COMPANY
M/s Sati Jasnath Enterprises
Savitri Enterprises
GANGADHAN ENTERPRISES
KRISHNA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .