Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹39.4 L Quoted ₹39.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹43.0 L+₹3.5 L (8.91%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹43.0 L+₹3.5 L (8.91%) | L2 | Rejected-Finance L2 |
| 3 | L3₹43.3 L+₹3.8 L (9.73%)Rejected-Finance | ₹43.3 L+₹3.8 L (9.73%) | L3 | Rejected-Finance L3 |
| 4 | L4₹44.2 L+₹4.7 L (11.9%)Rejected-Finance | ₹44.2 L+₹4.7 L (11.9%) | L4 | Rejected-Finance L4 |
| 5 | L5₹44.2 L+₹4.7 L (11.9%)Rejected-Finance | ₹44.2 L+₹4.7 L (11.9%) | L5 | Rejected-Finance L5 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
23 Apr 2022, 6:00 pmClosed
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
PROVISION OF CERTAIN E/M WORKS SERVICES AT VARIOUS LOCATIONS STANDBY POWER SUPPLY AND SPL REPAIRS TO CERTAIN ACS INFRASTRUCTURE AT AIR FORCE SATION JAMNAGAR
2022_MES_501381_4
8147/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹77,000
Yes
10 May 2022
8 Apr 2022
25 Apr 2022
8 Apr 2022
23 Apr 2022
16 Apr 2022
Amount
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA
Supply and errectioing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (11 metres long) including two coats of aluminium painting over one coat of red oxide and butimin coating at bottom portion i,e at coping side with reflection painting all as specified and directed. Note:- (a) Rate quated is inclusive of following (i) Excavation&Earthwork, Returning filling and Removal of soil (ii) PCC (1:3:6) type C2 as per specification (iii) Coping (1:2:4) type B1 as per specification.
Material & Labour for static dischrge plate of size 30cm x30 cm x 3 mm complete fitting on hydroscopic insulator fixed on wall connecting to cooper strip with breezing all as specified and as directed.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed by Engineer –in- Charge at a level not exceeding 1.5mtr above the starting point all as directed.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009) for measurement purpose thickness of sand after punning down will be considered.)
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
S&F LED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed including mounting bracket of suitable length and size complete all as specified and directed. Make :-cat no. JETAVALOURFL200WLED757MODNBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES. .
S & F pole mounted junction box ( Street light boxes) sliding type ( Door fits to base by means of sliding) for 3 phase 4 wire lighting system, moulded in FRP including provision of 1 Nos MCB SP, 16 Amps,'C' curve and busbar insulator- 4 Nos with nut & bolts with fixing arrangement, outdoor type of dimesions 200 X 140X 95 mm (H X W X D) Product codeGSJB- 2014
S&F earth continuity conductor or main earthing strip of Copper strip of size 20 x 3.15 mm complete fixed to wall / celing in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed .
M&L for provn of chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 50x6mm complete all as specified.
S & F Air termination, single pointed, copper rod 12mm dia and 300mm long complete with all fitting arrangment.all as specifed and directed .
Supply & fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specifed and directed .
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, fixing in FRP box complete all as specified and as directed.
Supply and fixing High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 and bore 40mm, laid in trenches / on floor ceiling etc including with all fitting such as elbow, union reducer tees bends etc and short length for cable protection complete all as specified and directed .
Material and labour for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including.....part –I and testing on completion.
.....all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i)Earth result after installation completely should be less than 5 Ohm . (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length.
Supply & installation of Air Cooled Inverter based Flame proof split AC( Indoor unit Flameproof & outdoor unit Non flameproof) unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:-
(i) Refrigerent - R 410a (non CFC) (ii) EER - min 3.5 w/w (5 star rating) (iii) Tonnage - 1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode
All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: CROMPTON GREAVES, SUDDHIR SWITCHGEARS LTD, M/S BALIGA, FLEXPRO ELECTRICALS, NASIK SHYAAM SWITCHGEARS PVT LTD, MUMBAI ELECTRON LIGHTING SYSTEM
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:-
(i) Refrigerent - R 410a (ii) EER - min 3.5 w/w (5 star rating) (iii) Tonnage - 1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Carrier/ Hitachi/ O General/or Equivalent of makes as given as Appendix 'B'.
Note:- For Sr No 19 & 20 Following will be inclusive in rate:- (a) Piping length upto 15 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) Contractor will provide warranty of 5 years for compressor from the date of installation (f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner (g) Contractor provide complete free service in warrenty period by the company
S & F flameproof metal clad plug & socket board Single pole and neutral enclosure with two pin and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and as directed .
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Supply and installed voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stablized at 230V with accuracy of (+,-) 2.5 % and capacity 4 KVA .
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 4 Sqmm drawn through in and including Non metallic PVC casing caping into wall / ceiling with all accessories with 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note: 3 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment..
S & F metal clad plug & socket board Single pole and neutral enclosure with two pin and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified and as directed .
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed. Make:-cat no. DHDNSHODAWO8 of havells or equivalent of makes given in Appendix'B".
S & F MCB 6-32 Amps, SPN with 'C' curve fixed in DB/Panel box complete all as specified and as directed.
Supply and fix MCB single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply & fix in replacement of UPS, 600 VA capacity bearing model No Backups 600, IS 16242 Pat- I, 2014R 813000450, 230V, 2.6 Amp of make schneider or equivalent (as approved by GE) suitable for backup SCADA system of air conditioning ceiling suspended unit, all as already provided at site.
Supply & fixing in replacement of temperature sensor and humidistats bearing model No qfm2160, 0-10V, DC for 20 milliamp analog output of make seimens or equivalent of schneider/Johnson (as approved by GE), suitable for backup SCADA system of air conditioning ceiling suspended unit, all as already provided at site.
Supply and fixing in replacement Pressure Independent Control Valves of size 01 inch complete all as specified and directed. Make ; Johnson, Honeywell, seimens.
Supply and fixing in replacement Actuator Motor model No GLB161.9E, AC 24 Volt Class II, 50-60 Hz, 3VA, IP 54, 32T55 of make siemens or equivalent of Johnson/Honeywell (approved by GE) suitable for ceiling suspended unit for hot & cold motor connected with Pressure Independent Control Valves, all already as provided at site.
Supply & Fix in replacement Fan assembly unit of dia 800mm, model No FN080-SDQ.6N.V7P5 185477 of make Voltas or equivalent (approved by GE) suitable for 180TR chiller, all already as provided at site.
Supply & Fix in replacement Driver assembly suitable for 180 TR chiller of supply voltage 210-240 volt Ac version UC5011 unit all as specified and directed . Make :- Voltas or equivalent (as approved by GE)
Supply & Fix in replacement crank case Heater suitable for 180 TR chiller unit all already as provided at site. Make :- Voltas or equivalent (as approved by GE)
Supply & Fix in replacement Fan overload relay Board suitable for 180 TR chiller unit all already as provided at site. Make :- Voltas or equivalent (as approved by GE)
Supply and Fix in replacement of UPS battery(Rechargable) ,maintenance free of capacity 42 Ah all as specified and directed .
Supply and fixing in replacement differential Water pressure Switch suitable for 3TR CSU. Make : DANFOSS, SIEMENS, HONEYWELL and Schneider.
Supply and fixing in replacement VFD of model No ACS550-01-031A-4 for secondary pump of make ABB or equivalent of L&T/Seimens (as approved by GE)
Supply and fixing in replacement butterfly valve of bore size 150mm all as specified and directed . Make : AUDCO, KIRLOSKAR, ZOLOTO,TATA, LEADER
S&F in replacement Solenoid coil assembly operating on 230 volts AC 12V of size 3/8 inch of model No BS230AS of make Danfoss or equivalent of Indfoss/Zoloto (as approved by GE) with complete connection all as specified and directed.
Supply and Charging Lubricating Oil for scroll type compressor (Mineral oil SUILE BSE 170) complete all as specified and directed . Make:-Bitzer(synthetic refrigeration compression oil or equivalent (as approved by GE)
Note for item No 29 to 42:- 1. Exact location, item, description, specifications, etc may be verified by the tenderer on site with prior permission before tendering. No claims on this account shall be entertained at later date on this account. Tenderer's quoted rates are deemed to include the cost for the same.
2. Makes, models, description, etc are all as that originally provided at site. In case the manufacturer has stopped manufacturing the models mentioned under the items, tenderer shall intimate the same before quoting the tenders. Otherwise quoted rates are deemed to include for provision of upgraded version of model with No price adjustment on Plus side. But with price adjustment on minus side. For minus side price adjustment, cost of material shall be considered as 70% of the quoted rate.
Supply install testing and commissioning of diesel Engine driven generating set 25 KVA capacity, 3 phase, 4 wire, 440 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures having salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application/installation. Integrated design thereby facilating/easy handling installation and shifting of... .
...the eqpt at site. The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2:4) type B-1 foundation as recommended by manufacturer , Vibration pad sand cushioning around PCC foundation etc all and Tools and spares as provided by manufacturer all as specified and as directed with the following specifications :-.
(A) ENGINE : Water cooled with radiator diesel Engine (confirming to IS : 10001/10002) of 1500 RPM capacity to match the 25 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS 6514/ IS 10001 / 10002 the Engine shall consist of the following :-
(i) Fly wheel
(ii) Flexible coupling with guard bolts and nuts etc.
(iii) Air cleaner heavy duty dry type
(iv) Radiator with guard and water pump engine mounted.
(v) Dynamo of suitable capcity (vi) Air cleaner heavy duty dry.
(vii) Fuel injuction pump.
(viii) Radiator fan (Blower type) with guard.
(ix) Electronicv/ A1 class governer.
(x) Fuel filter (Mounted).
(xi) Lubricating oil filter (mounted).
(xii) 12V self regulating alternator belt driven by engine
(xiii) Exhaust silencer heavy duty residential type.
(xiv) Corrosion resistor / scale inhibitor.
(xv) Starter 12 V DC.
(xvi) Lubricating oil cooler.
(xvii) Lubricating oil pump (Gear type).
(xviii) Turbo Charger
(xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet.
(xx) Instrument panel complete with the following:-
(a) Auto mannual starting switch with key.
(b) Lubricating oil tempreture gauge.
(c) Lubricating oil pressure gauge.
(d) Water tempreture gauge.
(e) Battery charging ammeter.
(f) Battery charging indicating lamp.
(g) Hour meter with RPM indicator.
(h) Safety control against high temperature of water.
(j) Safety control against low lubricating oil pressure.
(k) Over speed stop with double driven adoptor.
(B) BRUSH LESS ALTERNATOR
(i) Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364
(ii) Type :- Self excited self regulated with automatic voltage regulator.
(iii) Rating :- 25 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition 3
(iv) Speed :- 1500 RPM
(v) System :- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz.
(vi) Connection :- 4 wire star connected.
(vii) Enclosure :- Screen protected dip proof.
(viii) Ventilation :- Self ventilated
(ix) Insulation :- Insulation Class H
(C) AUTOMATIC CONTROL PANEL
Built in AMF panel for automatic ON during power failure and off while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 16 SWG , over an angle iron frame made out of 50 x 50 x 6 mm angle with removable side cover hinged front panel and rear panel of easy accessibility complete with internal wiring of suitable size copper conductor cable and cable glands for external connection and comprising of following :-
(i) Main in coming MCCB 4 pole 415 volts suitable for 25 KVA DG set (Recommended by Manufacturers)
(iv) Frequency metre digital type - 01 No
(v) HRC type instruments fuse
(vi) LED type signal lamp for DG set/ commercial power on off indication - 06 nos
(vii) Copper bus bar of suitable size.
(viii) Circuit diagramed plate
(ix) CT operated KWH metre - 01 No
(x) Power factor meter digital type - 01 No
(xi) Reverse power relays and suitable contactors - 01 Set
(xii) mannual mode, auto mode, test mode - 01 set
(xiii) single phase preventer - 04 Nos
(xiv) Battery charger
(xv) All relays/power contactors of suitable size and capacity
(D) ONE SET OF ACCESSORIES COMPRISING OF :-
(a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping.
(i) Level indicator on fuel tank
(ii) Drain plug
(iii) MS class 'C' piping for inlet from pump to tank of engine
(iv) Fuel strainer
(v) Air vent
(b) BATTERY (As recommended by manufacturers)
(C) BASE PLATE (Fabricated out of MS channels ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer)
Note:- the quotted rate shall include construction of foundation/plinth of PCC 1:2:4 type B-1 of suitable size and 0.5 mt below ground and 1.5 metre above ground.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed.
M&L for Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4 mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe medium grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber...
..and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly Reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed by Engr-in-charge. Note:-Quoted rates shall be deemed to include for GI wire with protection pipe up to 7.5 M length.
M&L for sub main wiring with two run of single core PVC insulated copper cable multi-stranded conductor 6 Sqmm drawn through in and including Non metallic PVC casing caping into wall / ceiling with all accessories with 6.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed. Note: 3 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
S&F Distribution board made out of sheet metal powder coated, factory made, enclousure double door type TPN 4 way vertical type with 200 (Amps rated copper bus bar, neutral bar, earth bar, TP 43 protection including provision of 1 nos incomer MCCB 63 Amps, triple pole and neutral, 415V, 16 KA breaking capacity fixing of DB flush to wall surface complete all as specified and directed. Make:-cat no. DHDMTVORCWO4 of havells or equivalent of makes given in Appendix'B".
S & F MCCB 63 Amps, 16 KA TPN fixed in DB/Panel box complete all as specified and as directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
M&L for 40 mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground cable when crossing the road/fixing all as specified and directed.
Boring under roads/pavement/hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. (Note : Necessary infrastructure reqd for boring shall be arranged by the Contractor at his own cost).
Vijay Construction Co
EVEREST BUILDERS
Chamunda Kruparefrigeration
suvidhiconstruction
Sukhi Electricals
jitendra c joisar
rajengineers
M/s Jagdish Machinery Stores
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .