| Sl No | Description | Qty | Unit | FAIRWAY ENTERPRISE L2 | CHATTERJEE ELECTRICALS L4 | ELECTROTECH L5 | T. K. ENTERPRISE L3 | SUMAN ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Digging out the existing damaged MS Cable Tray, MS angle (50mm X 50mm X 5mm) grouted in wall with the help of 02 no Santras, 01 no Electrician & 02 no helper as per direction of EIC. with necessary arrangement as per direction of EIC | 6 | day | 1,250 ₹7,500 | 290 ₹1,740 | 1,000 ₹6,000 | 450 ₹2,700 | 250 ₹1,500 Lowest |
| 2.00 | Dismantling the existing following PVC/XLPE Al. Ar. cable from outside wall by expert workers also from very difficult possitions very carefully to avoid any further damages as per direction of the EIC.
a) 3.5 core 185 sqmm | 80 | Mtrs | 75 ₹6,000 | 29 ₹2,320 | 125 ₹10,000 | 25 ₹2,000 Lowest | 25 ₹2,000 Lowest |
| 2.01 | b) 3.5 core 95 sqmm | 60 | Mtrs | 70 ₹4,200 | 17 ₹1,020 | 135 ₹8,100 | 15 ₹900 Lowest | 15 ₹900 Lowest |
| 2.02 | c) 3.5 core 70 sqmm | 95 | Mtrs | 70 ₹6,650 | 14 ₹1,330 | 165 ₹15,675 | 12 ₹1,140 Lowest | 12 ₹1,140 Lowest |
| 2.03 | d) 3.5 core 35 sqmm | 90 | Mtrs | 45 ₹4,050 | 12 ₹1,080 | 105 ₹9,450 | 10 ₹900 Lowest | 10 ₹900 Lowest |
| 2.04 | e) 3.5 core 25 sqmm | 120 | Mtrs | 38 ₹4,560 | 6 ₹720 | 95 ₹11,400 | 5 ₹600 Lowest | 5 ₹600 Lowest |
| 3.00 | Supply of following XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells/Polycab/Gloster/KEI/As per choice of EIC]
4 core 95 sq. mm. multy stranded Aluminium conductor Armoured cable. | 30 | Mtrs | 778 ₹23,340 | 1,218 ₹36,540 | 625 ₹18,750 Lowest | 2,050 ₹61,500 | 1,050 ₹31,500 |
| 3.01 | 4 core 70 sq. mm. multy stranded Aluminium conductor Armoured cable. | 50 | Mtrs | 720 ₹36,000 | 971 ₹48,550 | 325 ₹16,250 Lowest | 837 ₹41,850 | 837 ₹41,850 |
| 4.00 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
Above 150 sqmm | 90 | mtr | 18 ₹1,620 | 8 ₹720 | 202 ₹18,180 | 7 ₹630 Lowest | 7 ₹630 Lowest |
| 4.01 | From 25sqmm to 150sqmm | 120 | mtr | 16 ₹1,920 | 6 ₹720 | 215 ₹25,800 | 5 ₹600 Lowest | 5 ₹600 Lowest |
Tender Value
Refer Docs
EMD Value
₹13,409
Closing Date
8 Sept 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Maintenance of E.I Work------- Repairing, replacement and Supply, Installation of cable tray and Fabrication work of different type iron stucture with allied EI work at Purta Bhawan, Salt Lake, Kolkata-91
2025_WBPWD_896675_1
WBPWD/EE/BED/e-NIQ-76/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Purta Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹13,409
18 Sept 2025
30 Aug 2025
10 Sept 2025
1 Sept 2025
8 Sept 2025
1 Sept 2025
Amount
Digging out the existing damaged MS Cable Tray, MS angle (50mm X 50mm X 5mm) grouted in wall with the help of 02 no Santras, 01 no Electrician & 02 no helper as per direction of EIC. with necessary arrangement as per direction of EIC
Dismantling the existing following PVC/XLPE Al. Ar. cable from outside wall by expert workers also from very difficult possitions very carefully to avoid any further damages as per direction of the EIC. a) 3.5 core 185 sqmm
b) 3.5 core 95 sqmm
c) 3.5 core 70 sqmm
d) 3.5 core 35 sqmm
e) 3.5 core 25 sqmm
Supply of following XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells/Polycab/Gloster/KEI/As per choice of EIC] 4 core 95 sq. mm. multy stranded Aluminium conductor Armoured cable.
4 core 70 sq. mm. multy stranded Aluminium conductor Armoured cable.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Above 150 sqmm
From 25sqmm to 150sqmm
Supplying, fabrication & fixings MS Angle of 5mm thick of size (50mm X 50mm) to make a base supporting fram for installation of MS cable tray incl. drilling 2 nos holes in vertical angle of size ( 50mm X 50mmX 5mm) and grouting the same with C.C. (1:1.5:3) etc fabricated with supporting angle of 50mm X 50mm X5mm at an angle of 45 degree with the wall for transmitting the load centrally through 01 no 50mmX 50mm X5mm vertical angle inserted into the existing wall as directed by EIC with drilling 04 nos holes in set , cutting holes into the wall & grouting with M10 Fastnut (10 mm) for installation of MS cable tray.The entire structure must be safe to carry out the entire load of the cable tray with the weight of different sizes of cable for proper maintenance in appropriate way.
Supplying, fabrication & fixings MS Cable tray by angle of 5mm thick of size (35mm X 35mm) including 2 sided with a gap of 1.5 feet parallaly a flat of 5mm thick of size 25mm X 5mm to be fabricated by 1.5feet face to face with the angle for transmitting the load centrally as per direction of EIC. The entire structure must be safe to carry out the weight of existing different sizes of cables for Sub-panel of building including proper maintenance for different floor in appropriate way.
Supplying, fabrication & fixings MS bridge type support by 04 nos 4 mm thick of size 100mm X 10mm X 4mm hollow bar including 6mm thick of size 75mm X 40mm X 6mm C-channel fabricated with the hollow MS section to carry out the support of existing cable tray. The entire structure must be safe to carry out the weight of MS cable tray and existing different sizes of cables for Sub-panel of building including proper maintenance for different floor in appropriate way.
Supplying, fabrication & fixings MS Angle of 5mm thick of size (40mm X 40mm) to make a base supporting fram for installation of MS cable tray incl. drilling 2 nos holes in vertical angle of size ( 40mm X 40mmX 5mm) and grouting the same with C.C. (1:1.5:3) etc fabricated with supporting angle of 40mm X 40mm X5mm at an angle of 45 degree with the wall for transmitting the load centrally through 01 no 25mmX 25mm X5mm vertical angle inserted into the existing wall as directed by EIC with drilling 04 nos holes in set , cutting holes into the wall & grouting with M10 Fastnut (10 mm) for installation of MS cable tray.The entire structure must be safe to carry out the entire load of the cable tray with the weight of different sizes of cable for proper maintenance in appropriate way.
Removal of rubbish (incl electrical items) etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (a) 25 mm thick plaster
Charges for dressing and proper arrangement of copper pipe after complition of AC machine of different floor as per direction of EIC.
Charges for insulation of copper pipe with elastometric nitrile rubber tubular sleeves section and wripping the same as per direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Surpackage/VRV/VRF/RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class O tubular insulation/with Class-0 closed cel! elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid ines, all accessories as per specification etc. as required. 1/4'' (6.4 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/8'' (15.88 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply & fixing of 3 core 2.5 sq mm Cu cable for inter connecting the indoor & outdoor units
Supply & laying PVC Drain pipe 25 mm dia with 6mm thick Nitrile Rubber insulation. (Suprime/Oriplast)
Charges for reparing, welding, the iron structure of grill guard & cable tray, MS platform of with proper arrangement as per direction of EIC.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint One coat of red lead/Zinc chromate priming
Second coat of red lead/Zinc chromate priming
1st coat of synthetic enamel paint over the primer
2nd coat of synthetic enamel paint over the 1st coat
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. One coat of red lead/Zinc chromate priming. 1st coat of aluminium paint over one coat of RO priming. 2nd coat of aluminium paint over 1st coat. Painting of Down road of light fittings along with "L" clamp
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
FAIRWAY ENTERPRISE (BID ID -6893771)
T. K. ENTERPRISE (BID ID -6896599)
CHATTERJEE ELECTRICALS (BID ID -6897393)
ELECTROTECH (BID ID -6898819)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .