Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹8.7 L (7.94%)Admitted-Finance | ₹1.2 Cr+₹8.7 L (7.94%) | L2 | Admitted-Finance |
| 3 | L3₹1.2 Cr+₹15.0 L (13.7%)Admitted-Finance | ₹1.2 Cr+₹15.0 L (13.7%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Lokesh Enterprises L1 | M/S HAMAYUN SARWAR KHAN L2 | M/S ZARGAR CONSTRUCTION CO L3 |
|---|---|---|---|---|---|---|
| 1.00Erection of 11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender) | ||||||
| 1.01 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) | 285 | Nos | - | - | - |
| 1.02 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation. (As per recommended IS/REC Standard) | 30 | Nos | - | - | - |
| 1.03 | Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
NOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) | 315 | Nos | - | - | - |
| 1.04 | Supplying and erection of GI Channel “V’' cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.
NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard) | 4,335 | Kgs | - | - | - |
| 1.05 | Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (As per recommended IS/REC Standard) | 2,400 | Kgs | - | - | - |
| 1.06 | Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) | 855 | Nos | - | - | - |
| 1.07 | Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) | 180 | Nos | - | - | - |
| 1.08 | Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard) | 75 | Nos | - | - | - |
| 1.09 | Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard) | 315 | Nos | - | - | - |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
2 Dec 2019, 2:00 pmClosed
Executive Engineer, ED, Rajouri
Laying of New 11kV Dedicated Feeder for PHE Dhangri emanating from 3.15 MVA R/Station Dhangri under Languishing Project on Turnkey Basis
Laying of New 11kV Dedicated Feeder for PHE Dhangri emanating from 3.15 MVA R/Station Dhangri under Languishing Project on Turnkey Basis
2019_PDD_81412_3
EDR/23
Open Tender
Electrical Works
Turn-key
60 days
RAJOURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
EXECUTIVE ENGINEER, ELECT. MRE DIVISION, RAJOURI
₹2.2 L
10 Jan 2020
20 Nov 2019
4 Dec 2019
20 Nov 2019
2 Dec 2019
20 Nov 2019
20 Nov 2019 - 2 Dec 2019
Amount
Erection of 11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation. (As per recommended IS/REC Standard)
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) NOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard)
Supplying and erection of GI Channel “V’' cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard)
Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (As per recommended IS/REC Standard)
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard)
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supply and fixing of Parallel Grove (PG) clamps, binding wire etc
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply and Fixing of Aluminium Jointing Sleeves
Erection of VCB and other facilities at Receiving stations for dedicated supply (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, Insurance, Unloading, Carriage, Delivery at Site, Erection and testing of 11KV VCB Panel (complete in all respects) with required CTR 400/200/5A, with master protection and other relays. (As per recommended IS/REC Standard)
Supply, Loading, Transportation, insurance, Unloading, Carriage,Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation for Outgoing Structure. (As per recommended IS/REC Standard)
Supplying and erection of GI channel (75x40x6 mm) cross arms for Outgoing Structure, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm including clamps(As per recommended IS/REC Standard)
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles (the leftover pit after concreting to be filled with soil and boulders) NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard)
Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard)
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)
Supply, Loading, Transportation, insurance, Unloading, Carriage, Delivery at Site and Laying of 11 kV Armoured Three Core XPLE FRLS Power Cable 185 mmsq (As per recommended IS/REC Standard)
Supply and fixing of 11 kV Heat Shrinkable Cable termination Kits Complete ( Indoor and Outdoor ) (As per recommended IS/REC Standard)
Supply and Installation of 11 KV, 600 Amp Double break Isolator with Earthing Blade complete with base Channels, operating Handle (As per recommended IS/REC Standard)
Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) Station Type (As per recommended IS/REC Standard)
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
M/S HAMAYUN SARWAR KHAN
M/S ZARGAR CONSTRUCTION CO
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
SBD23.pdf
Tender Documents • 0.52 MB
BOQ_160955.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .