Mr. Hitendrakumar Arvindrai Surti
Tender for the Work Supply, Laying, Testing & Commissioning Of 11KV underground XLPE Cable (Cable to be supply by DGVCL) with Cable End Termination and Straight joint kit (to be supplied by the Contractor / Agency) and HDPE green Pipe for HT Underground Cable Work and Erection of HT-LT lines & T/C etc. for work Under ND Scheme & ALL other Scheme at within Jurisdiction of UMARGAM IND. Subdivision Under Vapi Ind. Division.
365649
VPID/TECH/TENDER/2682 Dtd. 13.11.2026
Open
Electrical and Maintenance Works
Works
Valsad
4 documents required · 4 mandatory
₹3,540
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹28,500
13 Nov 2026
13 Nov 2026
13 Nov 2026
21 Nov 2026
13 Nov 2026
180 days
(A) CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Sr Item Code Description UNIT Rate
1 9926000001 HT TAPPING FROM THE EXISTING POLE INCLUDING NO.
FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS AND
NUMBERING COMPLETE WITH COST PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SET AND EARTHING.
2 9926000002 ERECTION OF PSC POLES OF 8METER 200 KG INCLUDING NO.
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTICLIMBING
DEVICES, INSULATORS ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
3 9926000003 ERECTION OF STEEL POLES OF 9 TO 11 METERS NO.
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS
ETC. COMPLETE AND PAINTING OF STEEL POLE,
FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
4 9926000004 ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY NO.
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV
OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS, TOP FITTING
CLAMPS,ANTICLIMBING DEVICES DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLES, FABRICATED MATERIALS USED ON THE POLES
ANDNUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.
5 9926000005 ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS NO.
200 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING
DEVICES DANGERBOARDS,INSULATORS ETC.COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING. (WITHOUT AB
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
6 9926000006 ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 NO.
METERS.STEEL POLE INCLUDING EXCAVATION OF PITS
&REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS,ANTI-CLIMBING DEVICES
DANGER BOARDS, INSULATORS ETC.COMPLETE
&PAINTING POLES,FABRICATED MATERIAL SUSED ON
THE POLES AND NUMBERING WITH COST OF PAINTSAS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET ANDEARTHING. (WITHOUT AB
7 9926000007 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH, HGFUSES OF 8 MTRS 200 KG
PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS SUPPORTING
ANGLES, CLAMPS,ANTI-CLIMBING DEVICES, DANGER
BOARDS, INSULATORS,DO FUSES ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
OF ERECTION OF GUY SET AND EARTHING. (WITH AB
8 9926000008 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH,HG FUSES, 9 TO 11 METERS
STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OF CHANNEL, SUPPORTING
ANGLES, CLAMPS, ANTICLIMBING DEVICES , DANGER
BOARDS, INSULATORS, ETC. COMPLETE AND PAINTING
OF POLES FABRICATED MATERIALS USED ON THE POLES
ANDNUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUTEXCLUDING
ERECTION OF GUY SET AND EARTHING. (WITH AB
9 9926000009 ERECTION OF DOUBLE POLE STRUCTURES WITH NO.
MOUNTING OFAB SWITCH,FUSES, TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER
BOARDS,CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
10 9926000010 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH,HG FUSES TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO
METERS STEEL POLES INCLUDINGEXCAVATION OF
PITS & REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE, FIXINGOF
CHANNELS SUPPORTING ANGLES, BRACING, CROSS
ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC.
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTIONS OF GUY SETS AND EARTHING.
11 9926000011 ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS NO.
& REFILLING OF EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS, STAY WIRE,
ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY
INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
12 9926000012 CONCRETING OF POLES, GUYS, ETC. INCLUDING COST CMT
OF CEMENT SAND METAL (1:2:4)AND WATER ETC. AS
PER STANDARD SPECIFICATION.
13 9926000013 ERECTION OF COIL TYPE EARTHING INCLUDING COST OF NO.
COAL,SALT ETC. BUT WITHOUT COST OF Gl WIRE AS PER
STANDARD SPECIFICATION(20kg salt+20kg coal)
14 9926000014 ERECTION OF Gl PIPE/CI PLATE TYPE EARTHING NO.
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE Gl WIRE AS PER
STANDARDSPECIFICATION. (20k solt+20k coal)
15 9926000015 ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH NO.
CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK
WOODBUSH,REFLECTORS FUSE, WIRING ETC. AS PER
STANDARD SPECIFICATION BUT EXCLUDING COST OF
16 9926000016 STRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONECONDPER KM
CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING
FIXING OF INSULATORS BINDING JUMPERING ETC.
17 9926000017 STRINGING OF Gl WIRE 8 SWG INCLUDING BINDING DO
18 9926000018 PROVIDING SINGLE PHASE SERVICE CONNECTION WITH- NO.
PVC 4MM TWIN CORECABLE FROM TERMINAL POLE
TOMETERING POINT INCLUDING FIXING OFMETER WITH
METER EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
19 9926000019 PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION NO.
WITH PVC 4MM2/10MM2 FOUR CORE CABLE FROM
TERMINAL POLE TO METERING POINT INCLUDING FIXING
OF METER WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING COST
20 9926000020 ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD NO.
ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS PER
STANDARD SPECIFICATION OVER & ABOVE NORMAL
COST COVERED AGAINST EXCAVATION OF PIT UNDER
NORMAL SOIL FOR ERECTION OF POLE,GUY, DOUBLE
POLE STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE NO.
24 9926000024 LT LINE TAPPING- THREE PHASE NO.
25 9926000025 LAYING OF OVER HEAD LT CABLE FOR ROAD NO.
CROSSING,HT LINE CROSSING AND TELEPHONE LINE
CROSSING ETC.(PER SPAN)
26 9926000026 ERECTION OF SINGLE POLE STRUCTURESWITH, HG NO.
FUSES,TRANSFORMERS,LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KG PSC POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
27 9926000027 ERECTION OF SINGLÉ POLE STRUCTURES WITH NO.
HG FUSES,TRANSFORMERS,LIGHTENING
ARRESTOR, DISTRIBUTION BOX. ON 9 to 11 METERS RSJ
POLE INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH, CARTING OF TRANSFORMERS FROM STORES
TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND EARTHING.
28 9926000028 ERECTION OF PSC POLES OF IO METER 270 KG NO.
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OF CROSS ARMS, TOP FIITING CLAMPS
ANTICLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
29 9926000029 ERECTION OF DOUBLE POLE STRUCTURE OF 10 METER NO.
270 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING
DEVICES DANGERBOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARDSPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS ANDEARTHING.
WITHOUT AB SWITCH
30 9926000030 STRINGING OF IOOMM2 ACSR/100MM2 AAAC ONE
CONDUCTOR FOR HT/ LT LINES INCLUDING FIXING OF
INSULATORS, BINDING JUMPERING ETC. COND
31 9926000031 STRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES ONE
INCLUDING FIXING OF INSULATORS, BINDING JUMPERING
32 9926000032 ERECTION OF DOUBLE POLE STRUCTURES WITH NO.
MOUNTING OF AB SWITCH,HG FUSES, TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KG PSC POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTI-CLIMBING DEVICES,DANGER
BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
33 9926000033 DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING No.
OF FABRICATION AT STORE &STACKING OF POLE SAFELY
ON ROAD SIDE OR CREDITING TO DEPARTMENTAL
34 9926000034 DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING No.
OF FABRICATION AT STORE & STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
35 9926000035 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC No.
POLE) (WITH TRANSFORMER) WITH CREDITING OF
FABRICATION & TRANSFORMER AT STORE & STACKING
OF POLE SAFELY ON ROADSIDE OR CREDITING TO
DEPARTMENTAL STORE
36 9926000036 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC No.
POLE) (WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OFPOLE SAFELY ON
ROAD SIDE ORCREDITING TO DEPARTMENTAL STORE
37 9926000037 STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM KM
INCLUDING FIITING OF ALL ACESSORIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING
OF MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCE-ING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
38 9926000038 STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ KM
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCE-ING CONNECTORS
THROUGH SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
39 9926000039 STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGNSUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLEPOINT,JUMPERS ETC. AS REQUIRED &DIRECTED
BY ENGINEER IN CHARGE
40 9926000040 STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGNSUSPENSION / TENSION CLAMP, FIXING OFCROSS
ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLEPOINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
41 9926000041 STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ KM
35 SQ MM INCLUDING FITTING OF ALL ACESSORIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING
OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCE-ING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
42 9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND Nos
CREDITING THE OLD MATERIAL TO STORE
43 9926000043 DISMENTALING TRANSFORMER CENTER ON IO Nos
MTR,270KG PSC POLE WITHOUT TRANSFORMER WITH
CREDITING OF FABRICATION AT STORE AND STACKING
OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
44 9926000044 DISMENTALING OF TRANSFORMERCENTER ON Nos
IOMTR,270KG PSC POLE(WITH TRANSFORMER) WITH
CREDITING OF FABRICATION AT STORE AND
STACKINGOF POLE SAFELY ON ROAD SIDE ORCREDITING
TO DEPARTMENTAL STORE
45 9926000045 DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM KM
AND CREDITING FITTINGOF ALL ACESSARIES AND
FABRICATION TO DEPARTMENTAL STORE
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
46 9926000046 DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM KM
AND CREDITING FITTINGOF ALL ACESSARIES AND
FABRICATION TO DEPARTMENTAL STORE
47 9926000047 DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ KM
MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
48 9926000048 DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ KM
MM+1*35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
49 9926000049 DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ KM
MM+ 1*35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
50 9926000050 RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT ONE
DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING
FIXING OF INSULATORS, BINDING JUMPERING ETC. COND
51 9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT ONE
LINES INCLUDING , BINDING JUMPERING ETC.
52 9926000052 LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR NO.
METER. (METER WILL BE PROVIDED BY DGVCL
53 9926000053 LABOUR CHARGE FOR THE REPLACEMENT OF DTR NO.
METER AND OLD METER SHOULD BE CREDITED TO SDN
STORE. (METERWILL BE PROVIDED BY DGVCL
54 9926000054 LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR PER
METER CONNECTION. (CT COILWILL BE PROVIDED BY
55 9926000055 LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR PER
DTR METER CONNECTION AND OLD CT SHOULD BE
CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED CT
56 9926000056 LABOUR CHARGE FOR FIXING OF MMB FORDTR METER NO.
(MMB WILL BE PROVIDED BY DGVCL
57 9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR NO.
METER BOX. (METER WILL BEPROVIDED BY
58 9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE NO.
COPPER CABLE 3.5 METER (CABLETO BE PROVIDED BY
59 9926000059 LABOUR CHARGE PER
FORPROVIDING/RECONNECTION OF
TERMINALCONNECTION WITH PROPER SIZE OF LUGS. TERMIN
LUGS COST IS BORNE BY AGENCY
60 9926000060 LABOUR CHARGE FOR THE SPOT READINGOF DTR METER PER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN
COPY BY SURVEYOR PERSON OF AGENCY IN PROFORMA DTR
REPORT SHOULD BE SUBMITTEDTO SDN ONLY IF
ALLPARAMETER OF VOLTAGE, CURRENT & LOAD AS
SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
61 9926000061 LABOUR CHARGE FOR THE SPOT READINGOF DTR METER PER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN
COPY BY SURVEYOR PERSON OF AGENCY IN PROFORMA DTR
REPORT SHOULD BE SUBMITTED TO SDN OFFICE. (DULY
FILL PER-FORMA IN FAULT CONDITION IN WHICH
READINGPARAMETER IS NOT SHOWN IN METER
62 9926000062 INSTALLATION OF DTR METER INCLUDING METER BOX, NO.
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND
CORE ARMOURED COPPER CABLE (3.5METER),
TERMINATION IN METER & COIL BOX,CT/PT COIL WILLBE
PROVIDED BY DGVCL
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
63 9926000063 INSTALLATION OF DTR METER INCLUDING METER BOX, NO.
TERMINATION IN METER & COIL ETC. (WITHOUT 10 CORE
COPPERCABLE) (METER,METER BOX,CT/PT COILWILL BE
PROVIDED BY DGVCL
64 9926000064 Binding of messanger Conductorat with a distance not NO
more than 0.75 mtr with 6 turns minimum on XLPE Cable
with single strand binding wire (including cost of binding
65 9926000086 Supply and Installation of 11/22 kV Distribution PER SET
Transformers HT Terminal protector (UV Resistance) with
using 95/120/150 sq.mm long barrel aluminum lug. (1Set
= 3 Nos i.e. on R, Y, B)
66 9926000087 Supply & Installation of HT EPR Tap on 11/22 kV PER SET
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to
transformer) after removal of semi conductor by HT ABC
(6 inch both side). HT ABC to be supplied by DGVCL.
(1Set = 3 Nos i.e. on R, Y, B)
67 9926000088 Supply, Installation, Testing and Commissioning of NO
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
Type, Earth Electrodes for HT Feeder Pole Having
mm Electrode Length as per the Tender Specifications
and Drawing. (All Materials Will Be Supplied By Agency)
68 9926000089 Supply, Installation, Testing and Commissioning of NO
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
Type, Earth Electrodes for HT Feeder Pole Having
mm Electrode Length as per the Tender Specifications
And Drawing. (All Materials Will Be Supplied By Agency)
69 9926000090 Supply and Installation of 25 X 3 mm GI Strip having hot Meter
dip- galvanized-zinc coating of 80-100 microns without
any joints or welding. Both the end of the GI strip should
be connected with GI nut bolts and required fabrication
work for giving separate earthing connections to(1)
Neutral of the transformer(2) MS structures of the
transformer center (Approximately 25 meter GI strip per
transformer centre- as per requirement and instruction
of Engineer in- charge) (All Materials will be supplied by
70 9926000092 Supply and Installation of uPVC standard make Pipe of Meter
1.25" diameter for covering GI strip with UV protected
Cable Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip
covering per transformer centre -as per requirement and
instruction of Engineer in-charge.
71 9926000093 Supply & fixing of upto 33 kV Conducotr sleev for Busbar per TC
to Drop out Fuse and Drop out fuse to Transformer H.T.
including Busbar (12 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
72 9926000100 Supply & fixing of upto 33 kV Conducotr sleev for Busbar per TC
to Drop out Fuse and Drop out fuse to Transformer H.T.
without Busbar (15 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
73 9926000094 Supply & fixing of upto 33 kV Conducotr sleev for Busbar per TC
to Drop out Fuse and Drop out fuse to Transformer H.T.
including Busbar(15 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
74 9926000101 Supply & fixing of upto 33 kV Conducotr sleev for Busbar per TC
to Drop out Fuse and Drop out fuse to Transformer H.T.
without Busbar(15 mm sleev) as per technical
specification. (All Materials will be supplied by Agency)
75 9926000095 Supply & fixing of Disc type Red Color FRP(Non- NO
flammable) material with Weather resistant, Non-
conductive bird guard OD=300 MM, ID=33 MM, Width
=1.25 MM, one side cut from ID to OD. (All Materials will
be supplied by Agency)
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
76 9926000096 Providing and fixing of LT Terminal protectors i.e. Re- NO
useable boot (LT Side 1.1 kV) including LT (1.1 kV)
insulating taps. All live part at LT side shall be covered
with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per tc
77.3 9926000099 Labour charge for fitting Nylon Net (All fabricated Per tc
material for fitting nylon net shall be provided by
(B)Labour Charges for Maintenance Work
1 9924000001 Cutting of Tree branches surrounding HT/LT line per Tree
2 9924000002 Replacement of old jumpers & providing new double No
jumpers with 8" binding & capsuling with PVC pipe etc.
3 9924000005 Support pole for stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
5 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in No.
coastal area with cleaninGg .
6 9924000008 Pin binding of conductor LT shackle insulator No.
7 9924000009 Replacement of one/bothinsulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Re-fixing of V cross Arm No.
10 9924000012 Re placement of V cross Arm No.
11 9924000013 Re-fixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
14 9924000016 Providing DO fuse on DP with carting& jumpering (ONE No.
15 9924000017 Numberings of pole with paint by preparing back ground No.
of one colour and
have lettering(height 3" * width0.5" using stencil
16 9924000018 Fixing of MMB(IPH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (Iph.) meter forUrban area No.
19 9924000021 Replacement of (Iph.) meter for Rural area No.
20 9924000022 painting consumer no. on MMB (Urban) (with letter size No.
height40mm* width 8mm
21 9924000023 painting consumer no. on MMB (Rural) (with letter size No.
height 40mm* width 8mm
22 9924000024 Replacement of deteriorated Single hase Service line No.
23 9924000025 Fixing of new dist. Box with complete wiring includin No.
clamps, nut bolts etc.
24 9924000026 Repairing of guarding involving reshaping of bearer wire R Mtr.
cross lacing binding etc.
25 9924000027 Painting of steel fabricated material of RSJ DO DP No.
structure with paint
26 9924000028 Painting of steel fabricated material of RSJ pole mounted No.
transformer double pole structure with paint
27 9924000029 Painting of steel fabricated material of RSJ single pole No.
28 9924000030 painting of steel fabricated material of PSC Single pole No.
(HT line) with paint
29 9924000031 painting of steel fabricated material of PSC DO DP No.
double pole with paint
30 9924000032 painting of steel fabricated material of PSC double pole No.
at pole mounted transformer with paint
31 9924000033 Providing line separator single phase No.
32 9924000034 Providing line separator three phase No.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
33 9924000035 Replacement / Providing of stay insulator along with No.
of tension in stay wire
34 9924000036 Replacement of deteriorated /providing LT dist. Box with No.
new up to 100KVA capacity & crediting it to store.
35 9924000037 Replacement of deteriorated /providing LT dist. Box with No.
new above 100KVA capacity & crediting it to store.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
38 9924000040 Converting pin point to Shackle point including location
dismantling & restringing etc.
39 9924000041 replacement of 11KV Pin insulator with providin new No.
double in binding
40 9924000042 replacement of 22KV Pin insulator by new 11 kv pin No.
insulator with spares & providin new double in binding
41 9924000043 Providing 11 kv double disc insulators with binding & No.
42 9924000045 Replacement of existing conductor (all size) with new Cond/KM
double in binding
43 9924000046 Plumbing of psc Pole with straightening at pin point No.
44 9924000047 Plumbing of psc Pole with straightening at tension point No.
45 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with No.
refilling of stone Murrum etc.
46 9924000049 Providing new 11 kv AB [GO switch with fabrication and Set
insulated colour code jumper binding lugs etc.
47 9924000051 Replacement of old 11 kv AB /GO switch with providing Set
new insulated jumper, binding, lugs etc.
48 9924000052 Providing cage type loop guard in vertical LT line with per pole
using PVC reel insulators etc.
49 9924000053 Labour charges for replacement /providing of MMB & No.
service with all
accessories for three phase connection
50 9924000054 Labour charges for replacement /providing of MMB & No.
service with all accessories for connection
51 9924000055 Dismantling of existing Dist. X'mer center (RSJ/STP POLE) No.
with all fabrication & crediting the old material to store.
52 9924000056 Disconnection from LT pole 1 phase No.
53 9924000057 Reconnection from LT pole 1 phase (payment after No.
receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
55 9924000059 Reconnection from LT pole 3 phase (payment after No.
receipt of R/C chagr es
56 9924000060 Dismantling & removing of service line from pole & No.
crediting to S/dn (1 phase)
57 9924000061 Dismantling & removing of service line from pole & No.
crediting to S/dn (3h phase )
58 9924000062 Reconnection of service line complete with PVC cable(1 No.
59 9924000063 Reconnection of service line complete with PVC cable(3 No.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
60 9924000064 Providing spiral type earthing by connecting earth No.
terminal with earth terminal of meter box with G.I. SWG
no 8 up to 1.5meters (total weight approximately 2.2kg-
20 meter in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia (1.5mtr length) to
cover exposed part of G.I. wire , providing and fixing of
single core 1.5 sq mm single strand copper insulated
cable with cable nail clip to be connected with connector
to G.I. wire at consumer end as per drawing DGVCL cons.
earth. Earth resistance should be less than 2 ohms(All
materials supplied by contractor .
61 9924000070 Providing and fixing of single core 1.5 sq mm single per meter
strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of G.I. no
8 is to be connected by connector with copper cable of
which other end shall be connected to the earth terminal
of meter box. This item shall be used in location where
there is more distance between earth terminal and
earthing terminal of meter. All materials supplied by
(C) Fabrication from Raw Materials Of Mild Steel
62 9910000049 Fabrication of Anchor Rod from 16 SQ.mm MS Round bar No.
& 65 mm x 65 mm x 6 mm M.S. angle as per approved
drawing and requirement of the company.
63 9910000050 Fabrication of Anchor Rod from 16 SQ.mm MS Round bar No.
& 50 mm x 50 mm x 6 mm M.S. angle as per approved
drawing and requirement of the company.
64 9910000015 Fabrication of Eye Bolt from 16 SQ.mm MS Round bar No.
with supplying of 2 (two) nuts of suitable size as per
approved drawing and requirement of the company.
65 9910000028 Fabrication of Turn Buckle from 16 SQ.mm MS Round bar No.
& 65 mm x 65 mm x 6 mm mm M.S. angle as per
approved drawing and requirement of the company.
66 9910000016 Fabrication of Turn Buckle from 16 SQ.mm MS Round bar No.
& 50 mm x 50 mm x 6 mm M.S. angle as per approved
drawing and requirement of the company.
67 9910000030 Fabrication of 11' (feet) long Top/Bottom/D.O. angle from No.
65 mm x 65 mm x 6 mm M.S. angle as per approved
drawing and requirement of the company.
68 9910000031 Fabrication of 9' (feet) long Top/Bottom/D.O. angle from No.
65 mm x 65 mm x 6 mm M.S. angle as per approved
drawing and requirement of the company.
69 9910000003 Fabrication of 4'6" (feet) long Tapping / bracing angle No.
from 65 mm x 65 mm x 6 M.S. angle as per approved
drawing and requirement of the company.
70 9910000039 Fabrication of 2'3" (feet) long bracing/ support angle No.
from 65 mm x 65 mm x 6mm M.S. angle as per
approved drawing and requirement of the company.
71 9910000021 Fabrication of 11KV HT 'V' Cross Arm from 65 mm x 65 No.
mm x 6 mm M.S. angle as per approved drawing and
requirement of the company.
72 9910000022 Fabrication of 11KV HT Top fitting from 65 mm x 65 mm No.
x 6 mm M.S. angle and 50mm x 6 mm M.S. flat as
per approved drawing and requirement of the company.
73 9910000055 Fabrication of 22KV HT Top fitting from 65 mm x 65 mm No.
x 6 mm M.S. angle and 50mm x 6 mm M.S. flat as
per approved drawing and requirement of the company.
74 9910000037 Fabrication of 22KV HT 'V' Cross Arm from 65 mm x 65 No.
mm x 6 mm M.S. angle as per approved drawing and
requirement of the company.
75 9910000041 Fabrication of Guy Clamp pair suitable for PSC pole from PAIR
50mm x 6 mm M.S. flat as per approved drawing and
requirement of the company.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
76 9910000024 Fabrication of 'U' Clamp from 50mm x 6 mm M.S. flat as No.
per approved drawing and requirement of the company.
77 9910000043 Fabrication of 'C' clamp suitable for PSC pole from No.
50mm x 6 mm M.S. flat as per approved drawing and
requirement of the company.
78 9910000044 Fabrication of ‘C’ clamp suitable for RSJ GIRDER pole No.
from 50mm x 6 mm M.S. flat as per approved
drawing and requirement of the company.
79 9910000056 Fabrication of Three hole patti from 50mm x 6 mm M.S. No.
flat as per approved drawing and requirement of the
80 9910000061 Fabrication of 11' (feet) long Top/Bottom channel from No.
100 mm x 50 mm x 5 mm M.S. channel as per approved
drawing and requirement of the company.
81 9910000060 Fabrication of 9' (feet) long Top/Bottom channel from No.
100 mm x 50 mm x 5 mm M.S. channel as per approved
drawing and requirement of the company.
82 9910000035 Fabrication of 11'(feet) long angle bracing from 50 mm x No.
50 mm x 6 mm M.S. angle as per approved drawing and
requirement of the company.
83 9910000034 Fabrication of 9'(feet) long angle bracing from 50 mm x No.
50 mm x 6 mm M.S. angle as per approved drawing and
requirement of the company.
84 9910000062 Fabrication of 11' (feet) long channel welded from No.
assorted length of scrap channel as per approved and
requirement of the company
85 9910000063 Fabrication of 9' (feet) long channel welded from No.
assorted length of scrap channel as per approved and
requirement of the company
86 9910000072 Fabrication of Guy Clamp pair suitable for 10 mtr PSC PAIR
pole from 50mm x 6 mm M.S. flat as per approved
drawing and requirement of the company.
87 9910000073 Fabrication of Guy Clamp pair suitable for 9/11mtr RSJ PAIR
GIRDER pole from 50mm x 6 mm M.S. flat as per
approved drawing and requirement of the company.
88 9910000066 Fabrication of 5' (feet) long Tapping angle from 65 mm x No.
65 mm x 6 mm M.S. angle as per approved drawing and
requirement of the company.
89 9910000067 Fabrication of H.T. Ext'n suitable for 22KV system from No.
65 x 65 x 6 mm M.S. angle as per approved drawing and
requirement of the company.
90 9910000068 Fabrication of H.T. Ext'n suitable for 11KV system from No.
65 x 65 x 6 mm M.S. angle as per approved drawing and
requirement of the company.
91 9910000069 Fabrication of 750 mm long Channel for HT AB conductor No.
from 100mm x 50mm x 5mm M.S. Channel as per
approved drawing and requirement of the company.
92 9910000070 Fabrication of 22KV HT "V" Cross Arm from 100mm x No.
50mm x 5mm M.S. Channel as per approved drawing
and requirement of the company.
(D) REPLACEMENT OF BARE CONDUCTOR BY HT / LT AERIAL BUNCH CONDUCTOR
1 9924000065 Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM KM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box
complete as required & directed by Engineer in Charge.
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
2 9924000066 Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 KM
SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box
complete as required & directed by Engineer in Charge.
3 9924000067 Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM KM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding
to pin insulator,preparing shackle point,jumpers etc. and
inclusive of dismantling charge of existing bare
conductor and crediting in to store complete as required
& directed by Engineer in Charge
4 9.924E+10 Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM KM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding
to pin insulator,preparing shackle point,jumpers etc. and
inclusive of dismantling charge of existing bare
conductor and crediting in to store complete as required
& directed by Engineer in Charge
5 9924000069 Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 KM
SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box
complete as required & directed by Engineer in Charge.
(E)LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT GST)
Sr. Item Code Description Unit Rate
1 9925000001 Labour charge for excavation of cable trench of Meter
400mm width x 1200mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
2 9925000002 Labour charge for excavation of cable trench of Meter
600mm width x 1200mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
3 9925000003 Labour charge for excavation of cable trench of Meter
400mm width x 1500mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench leng th is to be considered
4 9925000004 Labour charge for laying of 11kV / 22 kV XLPE Cable Meter
of size up to 240 mm2 & preparation of sand layer
100mm thick, in the cable trench & covering the
cable with 150 mm dia (Outer), thickness 25 mm,
meter long RCC half round muffs and providing and
fixing of 4inch width yellow colour polyethylene tape
with printing"CAUTION ELECTRIC CABLE BELOW' at
0.75 m depth from ground surface after laying cable
in trench. This will provide indication that electric
cable is passing underground so as to protect cable
from mechanical injuries, refilling the same, as per
Instruction of E gineer in Charge (EIC) .
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
5 9925000005 Labour charge for horizontal drilling using Auger Meter
machine without damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm 0.D. 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of
size up to 240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The detail map
obtained from HDD machine and excel sheet hard
and soft copy) indicating the respective depth and
distance from adjacent landmark for each segment
for HDD is must require to be submitted. HDD to be
carried out at depth 1.5 mtrs to 2.0 mtrs as per site
conditions and as er instruction of EIC.
6 9925000006 Labour charge for horizontal drilling manually Meter
without damage to surface road at max 2.0 mtrs
depth & putting of 6.11 kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of
size up to 240 mm2 size, as per Site Condition
(excluding cost of pipe). The detail map and excel
sheet (hard and soft copy) indicating the respective
depth and distance from adjacent landmark for each
segment of cable to be submitted. Drilling to be
carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as
per site conditions as per instruction of EIC.
7 9925000007 Supply of 6.11kg/cm2 , class-4,Green color, 110mm Meter
O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to IS
4984 and BIS certification for laying of underground
11KV/ 22KV XLPE cable up to 240 mm 2 size.
8 9925000008 Labour work for RCC concreting on disputed location CMT
and repairing of damage portion of road crossing for
the work carried out for roads crossing as well as
concreting & muffing of poles including all materials
9 9925000009 Providing & fixing concrete stone route marker of No
300 mm width x 150 mm thick x 650 mm height
embedded in earth at least 300 mm below &
mm above ground level respectively at distance
approx. 50 meters along the length of cable. The
RCC concreting (1:2:4)(all necessary materials will
be in bidder's scope) of route marker is to be carried
out 300 mm width x 150 mm thick x 300 mm below
ground level as per instruction of EIC. The route
marker should be with name of company with
approved yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder name
etc., marked with arrow sign is to be painted on it.
The route marker is to be fixed at location near to
any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
10 9925000010 Erection of D.P. (double pole) structure using 9 / 11 No
Mtr. RSJ pole with cable connection arrangement
along with fitting of necessary fabrication for 11KV
cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
11 9925000011 Erection of Single pole structure using 9 / 11 Mtr RSJ No
pole with cable connection arrangement along with
fitting of necessary fabrication for 11KV/22 KV cable
including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
12 9925000012 Erection of D.P. (double pole) structure using 8.0 Mtr. No
PSC pole with cable connection arrangement along
with fitting of necessary fabrication for 11KV cable
including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing
13 9925000013 Erection of Single pole structure using 8.0 Mtr PSC No.
pole with cable connection arrangement along with
fitting of necessary fabrication for 11KV/22 KV cable
including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting& muffing
14 9925000014 Labour charge for erecting of 11kV / 22 kV XLPE Meter
cable of size up to 240 mm 2 on DP Structure with
fixing of 02 Nos polymer cleats on top and middle
part. Polymer cleats, nut bolts etc. fixing material to
be provided by contractor.
15 9925000015 Providing & fixing of 6.11kg/cm2 , class4,Green perJob
color, 110mm O.D. 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS certification on the
erected DP structure for the mechanical protection of
cable by inserting the cable inside HDPE pipe. The
HDPE pipe shall be erected in such a way that
300mm shall be below the ground level and the rest
2700 mm shall be supported on the DP Structure
with 01 No Polymer cleat. All materials including
polymer cleat and Nut bolt to be provided by
16 9925000016 Providing and fixing of pipe type earthing from 80 No
mm dia class-B GI pipe with pit to be filled with salt
& coke and construction of chamber as per DGVCL
Drg. No. dg /100 for DP and cable. The earthing pit
should be joined with cable by G.I. strip of size 1"
width & 2 mm thick. All material GI pipe, Coke Salt
etc will be supplied by bidder.
17 9925000017 Supply & fixing of heat shrink type end terminations No
(outdoor) for up to 11kV 3C x 185 mm2 size XLPE
cable as per DGVCL technical s ecification
18 9925000018 Supply & fixing of heat & shrinkable end No
terminations (outdoor) for up to 22 kV 3C x 185 mm
2 size XLPE cable ( as per DGVCL technical
19 9925000019 Supply & fixing of heat shrinkable type end No
terminations (indoor) for up to 11kV 3C x 185 mm
size XLPE cable as per DGVCL technical
20 9925000020 Supply & fixing of heat & shrinkable end No
terminations (indoor) for up to 22 kV 3C x 185 mm
size XLPE cable as per DGVCL technical specification
21 9925000021 Supply & fixing of heat shrinkable straight through No
joint for up to 11kV 3C x 185 mm 2 size XLPE cables
as per DGVCL technical specification.
22 9925000022 Supply & fixing of heat shrinkable straight through No
joint type for up to 22kV 3C x 185 mm 2 size XLPE
cable as per DGVCL technical specification
23 9925000023 Labour charge for excavation of 2100mm long x No
1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as
per instruction of engineer-in-charge & covering the
cable with 150 mm dia (Outer), thickness 25 mm,
meter long RCC half round muffs & refilling same as
per instruction of EIC .
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
24 9925000024 Providing and fixing of insulating bus bar, made from No
11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat shrinkable
antitracking core insulating tubing (1.1KV), on both
end terminal using Aluminium long barrel heavy duty
up to 240 sq mm lugs, Aluminium bus connector.
Taping with PGclamp for bus conductor as per
drawing and as per instruction of EIC. The
Allurninium lugs and PG clamp shall be covered with
11KV/22KV HT insulating tapes.(11KV/22KV XLPE
cable will be in scope of DGVCL while all other
materials will be in bidder's scope.
25 9925000025 Testing of cable at various points and commissioning No
the feeder as per instruction of engineer-in-
charge.Test result shall be submitted by contractor
26 9925000026 Preparation and submission of 6 (six) copies, of Set
complete layout drawings with GIS mapping as per
actual cable routing showing road crossing, HDPE
pipe sleeving, jointing locations, markers etc.
27 9925000027 Providing and fixing of Sign Board at junction point No
Made out of 2 mm aluminium sheet size 750x300
mm (2.5 x 1 ft) rectangle, as per design, pretreated
with phosphate process and acid etching coated with
one coat of epoxy primer and two coats of best
quality paints, reflectorized with Hi Intensity retro —
reflective sheeting as per the latest and frame
fabricated from suitable size iron angle. The Sign
Board is to be fixed on the base prepared from
channel and bracing angles which is grouted by
means of cement concreting of 1:2:4 for size of
mm dia x 800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign board
will be given by InchargeEngineer. (a) Hi intensity
Micro prismatic Grade
28 9925000028 Providing and fixing of Sign Board (Danger Board) on No
Distribution Transformer Centers Made out of 2mm
aluminium sheet size 300x300mm (1X1 ft) as per
design, pre treated with phosphate process and acid
etching coated with one coat of epoxy primer and
two coats of best quality paints, reflectorized with Hi-
Intensity retroreflective sheeting as per the latest
and frame fabricated from suitable size iron angle.
The Sign Board (Danger Board is to be fixed at the
location as per instruction of In-charge Engineer. (a)
Hi intensity Micro prismatic Grade
29 9925000029 Providing & fixing of aluminium tag of size 250 mm No
(L) x 75 mm (W) from 3 mm aluminium sheet along
with 1.0 mm dia aluminium binding wire for fixing of
aluminium tag near end termination joint at DP
structure for identifying the cable. The details of
feeder i.e. 11 / 22 KV with feeder name should be
punched on the tag by letter punch of size 16 mm as
per instruction of In-charge Engineer.
30 9925000030 Supply & fixing of heat shrink type end terminations Nos
(outdoor) for 11kV 3C x 240 mm2 size XLPE cable as
per DGVCL technical specification.
31 9925000031 Supply & fixing of heat & shrinkable end Nos
terminations (outdoor) for 22 kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification
32 9925000032 Supply & fixing of heat shrink type end terminations Nos
(indoor) for 11kV 3C x 240 mm2 size XLPE cable as
per DGVCL technical specification
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
33 9925000033 Supply & fixing of heat & shrinkable end Nos
terminations (indoor) for 22 kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification
34 9925000034 Supply & fixing of heat shrinkable straight through Nos
joint for 11kV 3C x 240 mm2 size XLPE cables as per
DGVCL technical s ecification.
35 9925000035 Supply & fixing of heat shrinkable straight through Nos
joint type for 22kV 3C x 240 mm2 size XLPE cable as
per DGVCL technical s ecification
36 9925000038 Installation, Testing and commissioning of 11 KV,630 Nos
A SCADA Compatible, RRL type3 Way RMU including
Two numbers of earthings as per Drawing (material
is in bidder's scope) and as per DGVCL Technical
37 9925000039 Installation, Testing and commissioning of 11 KV,630 Nos
A SCADA Compatible, RRLL type4 Way RMU
including Two numbers of earthings as per Drawing
(material is in bidder's scope) and as per DGVCL
Technical specification.
38 9925000040 Installation, Testing and commissioning of 22KV,630 Nos
A SCADA Compatible, RRL type-3 Way, RMU
including Two numbers of earthings as per Drawing
(material is in bidder's scope) and as per DGVCL
Technical specification.
39 9925000041 Installation, Testing and commissioning of 22KV,630 Nos
A SCADA Compatible, RRLL type-4 Way, RMU
including Two numbers of earthings as per Drawing
(material is in bidder's scope) and as per DGVCL
Technical specification.
40 9925000042 Construction of plinth for 11KV, RRL type- 3 Way( i.e Nos
Two numbers of Isolator & One number of Breaker)
Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 11kv-01.
All required material will be supplied by contractor.
41 9925000043 Construction of plinth for 11KV, RRLL type4 Way (i.e Nos
Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 11kv-
02.AlI required material will be supplied by
42 9925000044 Construction of plinth for 22KV, RRL type- 3 Way (i.e Nos
Two numbers of Isolator & One number of Breaker)
Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 22kv-01.
All required material will be supplied by contractor.
43 9925000045 Construction of plinth for 22KV, RRLL type4 Way (i.e Nos
Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 22kv-
02.All required material will be supplied by
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0213/11/2026 Approved Date: 13-11-2026 16:16
44 9925000046 Modifications e.g. Providing and fixing ofTerminal Nos.
protectors i.e. Re-use able boot (HT Side 11/22KV, LT
Side 1.1KV) including 11/22 KV insulating taps and
L.T.(I.I KV) insulating taps ,Busbar, Tapping from Bus
Bar (11/22 KV XLPE cable) through P.G. Clamp for
H.T. Jumper to D.O. Fuse to bushings of Transformer
Center, providing & Fixing of jumper and providing &
fixing of Heat Shrinkable Anti Tracking CoreInsulating
Tubing (Insulation Level 11/22 KV) in H.T. jumper
Clamping arrangement of cable support frame on
both side of existing Over Head type Distribution
Transformer to utilize in Under Ground cable network
as per drawing & as per instruction of Engineer
incharge. All live parts i.e. PGClamp, connections of
D.O.fuses, HT bushings etc . shall be covered with
fixing of 11/22 KV HT insulating tapes. ( 11/22 KV
XLPE cable will be in scope of DGVCL while all other
materials will be in bidder's scope )
45 9925000047 Laying of any size of 11/ 22 KV XLPE /PILCCable in per cable
readymade trench or in open space
46 9925000060 Labour charges for lying of O/H XLPE cable pole to KM
47 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 NO
meter long RCC half round pipe
48 Laying,Testing & commissioning of Specially designed KM
11 KV 55 mm2 AAAC Medium Voltage Covered
conductor as per the technical specifications (with
49 Laying,Testing & commissioning of Specially designed KM
11 KV AL-59 ACS Medium Voltage Covered conductor as
per the technical specifications (with accessories)
TOTAL ESTIMATE- TWENTY FIVE LAKHS ONLY
Note :- All Rates are Excluding of GST.
Executive Engineer (O&M),
D.G.V.C.L.,Vapi ind. Division.
1.DGVCL will provide key material like M.S. materials,ABC/Bare conductors, PSC/RSJ Poles, Insulators,
Fabricated materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming
to the relevent ISI specification and as directed by engineer incharge.
3.Necessary electricity connection for fabrication items shall be provided by DGVCL on payment of required
charge for connection & electricity bill of the same shall be paid by the agency.
4.All the rates are inclusive of PF & Exclusive of GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ/PSC poles
& steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent
quality silver paint) is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC
File No: DGVCLDVPI/tender/e-file/4448/2026/3630/Technical
Approved By: Executive Engineer,Technical,DGVCLDVPI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT-2682.pdf
SCHEDULE-B.pdf
UG CABLE WORK FOR UMARGAM SDN.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .