Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹98.0 LAdmitted-Finance | +78.87% | ₹98.0 L | L1 | Admitted-Finance |
| 2 | L2₹100.0 LAdmitted-Finance | +82.50% | ₹100.0 L | L2 | Admitted-Finance |
| 3 | L3₹2.2 CrAdmitted-Finance | +300.37% | ₹2.2 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Non-Responsive to meet MQC of Tender |
| 5 | Rejected-Technical NO 1 57 CLIFFTHI COTTAGE NEAR KALLODI BAJPE MANGALURU 574 142 | DAKSHINA KANNADA | KARNATAKA | 574142 | - | - | - | Rejected-Technical Non-Responsive to meet MQC of Tender |
Tender Value
₹54.8 L
EMD Value
₹1.3 L
Closing Date
21 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER ELECTRICAL
ADMIN BUILDING, NEW MANGALORE PORT AUTHORITY, PANAMBUR, MANGALORE
Balance works of Construction of Electrical substation building and conversion of outdoor structure to indoor substation at NMPA colony
2026_NMPT_896372_1
NMPA/Mech/EE(E)I/2025/1492/1
Open Tender
Electrical Works
90 days
NEW MANGALORE PORT AUTHORITY, PANAMBUR, MANGALORE
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
FA and CAO, NMPA
₹1.3 L
Yes
13 Mar 2026
31 Jan 2026
23 Feb 2026
31 Jan 2026
21 Feb 2026
31 Jan 2026
BOQ perticulars
Part A - Civil Works
KSRB 2 -2.1 : Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bo ttom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. Specification. No. KBS 2.1(a) / 2.3.5
Extra lead charges for earth work from 50m upto 2Km
Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6 (uncoarsed), bond stones at 2m. Apart in each coarse including cost of materials, labour, curing complete as per specifications. KBS 5.1.13
KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of nominal mix 1:1:2 with 20mm and down size graded granite metal, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of nominal mix 1:1.5:3 with 20mm and down size graded granite metal, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of nominal mix 1:1.5:3 with 20mm and down size graded granite metal, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls (any thickness) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6
Providing a nd laying in position RCC M20 wi th OPC 27.20 kgs with 12 mm and down size graded granite metal coarse aggregates for chajja of 7.5cm average thickness, including the cost of all materials, labour HOM finishing curing complete excluding the cost of reinforcements as per specifications
Extra for providing throating or drip moulding to RCC roof edge/ Chajja with plastering as per specifications
KSRB 4 -3.1: Extra if vibrator is used for Item No.4-1 to 4-8 as per specifications. Specification No. KBS 4.2.6
KSRB15-6 : Providing floating coat of cement to plastering and finishing smooth including cost of materials, labour, curing complete as per specifications.
KSRB 4.9.2: Providing T.M.T Fe 500 steel reinforcement for R.C.C work including strai ght ening, cutting , bending, hooking, placing in position, lap[ping and / or welding wherever required, typing with binding wire and anchoring to the adjoining members wherever necess ary complete as per design(laps, hooks and wastage shall not be measured and paid) cost of all materials, labour, HOM of machinery, curing complete as per specifications . Specifications No. KBS 4.6.3
KSRB 4-6.5: Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specification . Specification No.KBS 4.6.2
KSRB 4-6.14: Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sloping or battering surface including folded plates where inclination to horizontal plane does not exceed 30 degree requiring shuttering only on the under side including cost of all materials, labour complete as per specifications No. KBS 4.6.2
KSRB 4-6.8: Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beams haunching s, cantilever , girders, bressumers and lintels exceeding 1m in depth including cost of all mater ials, labour complete as per specifications. Specification No. KBS 4.6.2
KSRB 4-4.1: Extra for use of water proofing compound in Cement concrete of mix 1:1:2,at one kg of compound per bag of cement. Specification No. KBS
Providing and constructing Laterite stone masonry including cost and conveyance of all materials etc. complete. As per specification. I.S. 3620/ 1979 having compressive strength not less than 3.5 N/ mm2 for saturated dry samples for superstructure in CM 1:6 (cement 45 kgs/ M3)
KSRB15 -3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry / concrete surface including rounding off corners wherever required smooth rendering,: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.
Providing and applying two coats of wall putty to inside plastered wall s and ceiling using white cement putty. Scraping and levelling the surface using steel blades and preparing the surface even and smooth by using different grades of sand paper, including the cost of all materials, cost of labour and scaffolding etc. complete as per specifications
KSRB 15 -15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including prep aring the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer
KSRB 15 -14.1: : providing and applying two coats with oil bound washable distemper of approved brand and shade on ceiling surface to give an even shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour , complete as per specifications
Providing and finishing external walls in two coats with water proof cement paint of approver brand and shade to give even shade after thoroughly brooming the surface to remove all dirt and loose material, free from mortar drops and other foreign mater cost of all materials, labour complete as per specifications
KSRB 7.5 : Providing and fixing pull and push type rolling shutters of approved make out of 18 gauge, 75mm wide cold rolled steel laths of convex corrugations, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alt ernate clips, suspension shaft with high tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearings arrangement for inside and out side locking with push and pull operations complete including pulling hooks, 4 nos of handles with all fittings and of materials, painted with a coat of red lead paint cost of materials, labour HOM etc. complete as per specifications
Applying red lead mix priming coat over new steel work including the preparing the surface after thoroughly cleaning the oil grease, dirt and other foreign matter and scoured with wire brushes fine steel tool, sand paper including cost of material, labour complete as per specifications
Providing and applying enamel paint two coats (excluding priming coat) over new steel or other metal surface brus hing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour complete as per specifications
KSRB 9.4-3:- Providing Mathi/ Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves(excluding cost of cement concrete and side clamps),but including cost of materials, labour, HOM of machineries complete as per Specifications.
KSRB 9 -7.3: -Providing and fixing in position fully paneled Mathi/ Nandi shutters for doors, styles and rails of 30mm.thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of matarials, labour, HOM of machineries complete as per specifications.(excluding cost of fixtures) Specification No. KBS 9.34
Providing and fixing factory made single leaf rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V -stabilized Isopthalic Gelcoat and on layer of 450 gsm E -Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/ m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, sha ll be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to RV/ TIFAC Composites Design center Standards and specifications and the door shutters tested in confirmation to IS 4020 -1994. The finish of shutter will be plain colour White/ Ivory/ Beige/ Light Grey or any other colour using high quality pigments. Excluding cost of fixtures and inclusive of supply of shutters to respective workspot.
Providing and applying two coats on wood surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications
Applying priming coat over wood surface after brushing with ready mix enamel priming paint including preparing the surface after thoroughly cleaning oil grease, dirt and foreign matter , sand papering and knotting the ready mix paint including cost of material, labour, complete as per specifications.
Providing and fixing Vitrified glazed tiles of approved make, quality & colour of size 600x600x10mm thick fixed on existing flooring with special adhesive for flooring, skirting and jointed with neat cement slurry mi9xed with pigment to match shade of tiles ,including providing spacers at required interval and removing stains, cost of materials, mortar labour etc., complete as per specification.
Providing ceramic tiles of approved make, shade and size for flooring, treads of steps, landing laid on a bed of 12 mm thick cement mortar 1:3 mix, flush with white cement using colour pigment, including the cost of materials, labour, curing, complete as per specifications
KSRB 11 -17 -1 : Providing and fixing C.P brass towel rail 740mm length,20mm dia with C.P brackets, fixed to wooden cleats with C.P brass screws including cost of materials, labour complete as per specifications.
KSRB 13 -6.1 -1 : Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.
Providing and fixing in position Brass Stop Cook of approved quality with 20 mm dia nominal bore including cost of all materials and HOM of equipment’s and as per specifications.
KSRB13 -6.2 -1: Providing and fixing in position brass stop cock of approved quality 20mm dia nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.
Providing and fixing 50mm nominal OD pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes and f ittings with one step CPVC solvent cement and testing of joints complete.(internal work exposed on wall)
Providing and fixing 25mm nominal OD pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete.(internal work exposed on wall)
Providing and fixing 20mm nominal OD pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete.(internal work exposed on wall)
Providing and fixing 15mm nominal OD pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)
Providing and fixing gun metal wheel valve con forming to IS specification of approved make as per directions including all lead and lift etc., complete. - for 50mm dia.
Providing and fixing gun metal wheel valve conforming to IS specification of approved make as per directions including all lead and lift etc., complete. for 25mm dia.
KSRB 13 -8.1: Providing and fixing to wall , ceiling and floor, medium density polyethylene pipes 6.00kgs/ sq.cm working pressure 75mm outside diameter with special flange, compression type fittings, wall clips,making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1/ 13.9 for internal water supply connection.
KSRB 13 -8.1: Providing and fixing to wall ,ceiling and floor, medium density polyethylene pipes 6.00kgs/ sq.cm working pressure 110mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1/ 13.9 for internal water supply connection
KSRB13 -7.1 -4 : Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13 .13
KSRB13 -7.1 -1 : Providing and fixing in position 25mm nominal bore gun metal non -return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per Specification No. KBS 13.2.10 / 13.13
KSRB13 -7.2 -4 : Providing and fixing in position 50mm nominal bore non -return valve vertical type of approved make including cost of all materials, labour and HOM of equipment with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13
Providing and fixing gun metal wheel valve conforming to IS specification of approved make as per directions including all lead and lift etc., complete. - for 50mm dia:
Providing and fixing gun metal wheel valve conforming to IS specification of approved make as per directions including all lead and lift etc., complete. for 25mm dia:
Providing and fixing Health faucet with 8 mm dia 1.2 mtr length steel casing pipe with wall fixing arrangements jaguar make (CODE- ALD-573)or equivalent including cost and conveyance of all labour, materials, fixing charges etc. complete.
Providing and fixing Metropole flush valve regular 40 mm size (code ARI-39011)with wall fixing arrangements jaguar make (CODE FLV -1093)or equivalent including cost and conveyance of all labour , materials, fixing charges etc. complete.
Providing, supplying, fabrication and erection of Structural steel works conforming to IS:2062 [E 250 (Fe 410 W) A] with minimum yield stress 250 Mpa in M.S. ladders, M.S. grill gates, manhole frames & covers for inspection chambers and cable ducts, using standard members such as M.S. plates, M.S. box sections, tubes, angles/ channels etc., each member connected to one another by welding, bolts & nuts etc., as per design, direction, complete including transportation, loading/ unloading, fabrication, cutti ng, straightening, bending if necessary, marking, making holes with drilling machines, fitting, welding, including surface preparation as per approved process cleaning of surface, and applying anticorrosive steel paint two coats
Constructing brick masonry inspection chamber 600 x 600mm, and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non -modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600 x 600mm int ernal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsi ze granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS
Dismantling existing structures like culverts, bridges, retaining wall and other structures including T & P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable materials and stacking of serviceable materials etc. complete for Reinforced cement concrete
Dismantling existing structures like culverts, bridges, retaining wall and other structures including T& P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable materials and stacking of serviceable materials etc complete R R masonry
Dismantling AC sheet roofing and stacking the materials within a radius of 50 m, including the cost of materials, labour, HOM complete as per specifications
Part B - Electrical Works
SUB HEAD - 1 (EQUIPMENTS)
Supply , Installations, testing, commissioning of LT 415 V, TPN, 50 Hz, LT Distribution Panel/switch board with 2 incomers with 1 changeover switch & 1 Bus coupler, and 2 incomer with interlock, outgoing MCCB feeders including necessary base frame, channels, foundation bolts, and all the required items are in contractors scope as per specification and site requirement
Supplying, Erecting, Testing and commissioning of of “OFF” line UPS system for suitable operation on 230 volts 50Hz with all accessories including batteries and wiring. 1) Rating 2 KVA OFF LINE UPS with 2 Nos, 12 volts 180 Ah capacity maintenance free batteries.
SUB HEAD - 2 (CABLING)
Digging of trench of 1.2mtr deep x 0.5mtr wide in hard soil refilling the trench to the required ground level and consolidating etc. complete.
Digging of trench of 2.5mtr deep x 0.5mtr wide in hard soil and removing the existing HT UG cable and C-cut Pipe from the trench refilling the trench to the required ground level and consolidating etc. complete.
Labour charges for shifting and laying of HT cable and C-cut pipe in existing trench as required.
Laying of 1.1 kv class LT UG cable in existing on wall/trench/duct/GI pipe / stoneware pipe as required.
a. 3.5C x 25 sq.mm
b. 3.5C x 35 sq.mm
c. 3.5C x 70 sq. mm
d. 3.5C x 120 sq. mm
e. 3.5C x 185 sq. mm
f. 3.5C x 240 sq. mm
g. 3.5C x 300 sq. mm
Supply and fixing of heavy duty cable glands suitable for UG cable of 1.1KV Class (metal only) at termination end.
a. 25 mm dia
b. 32 mm dia
c. 45 mm dia
d. 63 mm dia
e. 75 mm dia
Supply and fixing/termination of heavy duty aluminum lugs suitable for UG cable of 1.1KV Class to MCB/MCCB / termination end.
a. 3.5C x 120 sq. mm
b. 3.5C x 150 sq. mm
c. 3.5C x 185 sq. mm
Supplying and making straight through cable joint with epoxy resin including ferrules and other jointing materials for PVC insulated and PVC sheathed steel tape, wire armoured aluminum conductor cable of 1.1 kv grades of following sizes.
a. 10/16 sq. mm
b. 3.5C x 35 sq. mm
c. 3.5C x 70 sq. mm
d. 3.5C x 120 sq. mm
e. 3.5C x 150 sq. mm
f. 3.5C x 185 sq. mm
g. 3.5C x 240 sq. mm
h. 3.5C x 300 sq. mm
Digging of trench in hard soil 0.6 mtr deep x 0.5 mtr wide and refilling the trench to the require ground level and consolidating etc., complete.
Digging of trench in Asphalt Cutting 0.6 mtr deep x 0.5 mtr wide and refilling the trench to the require ground level and consolidating etc., complete.
Supplying and laying of Semicircular (C-cut) RCC pipes of 150mm dia, 25mm thickness and 1 meter length.
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm around the cable.
Providing & laying reinforced cement concrete pipes NP3 class of 450mm dia for culverts/Road crossing / Railway crossing including fixing collars using cement mortar 1:2 proportionate. Work includes cost & conveyance of Hume pipes, collars and other materials, labour, lead, lift, Loading, unloading, curing etc complete.
Supplying & laying double walled corrugated (DWC) /HDPE pipe including all necessary connecting sockets / couplings / tees/bends/end caps of same materials in existing trench / culverts/ Drain crossing.
a.180mm OD / 153mm ID
b. 63mm OD / 50mm ID
SUB HEAD - 3 (SUBSTATION ELECTRICAL WIRING & ACCESSORIES)
Supplying of 3 litres capacity Instant electric water heater 3KW, 230V AC.
Erection charges for fixing water heater using suitable heat resistance hose pipes / fittings /valves/ bolts and nuts, flat at one end nut and washers at the other end for through bolts and washers and wiring complete with 15A 3 pin top.
Supplying wall mounting fan of heavy duty suitable to operate at single phase 230V A.C. Supply a) 400mm Sweep.
Fixing a wall mounting fan on wall with bolts and nuts etc. complete.
Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete with M-30 for RCC works laid in 30cm thick layers and well compacted including vibrating curing etc , including smooth finish in CM 1:3 with all lead and lift etc complete for road crossing.
Supplying and laying of 40mm PVC conduit pipe (Blue color).
Supplying and drawing 3C x 2.5 sq.mm Flexible Multicore cable PVC insulated and sheathed suitable for working voltage up to 1100 volts.
Supply and Installation/ Fixing/ Provision of Outdoor type Thermoplastic Modular Panel of size 300x600x170mm enclosure with transparent Polycarbonate Lid ,shock proof , IP 65) rust proof ,dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix MCB with suitable transparent hinged flap opening for operating MCB along with complete tamper proof sealing facility and wiring with 10 sq.mm PVC copper wire and fixing to the pole with clamps bolts and nuts complete with following items:- a.)Supplying and fixing of 40A DP MCB. b.)Supplying and fixing of 60A, 4 pole power contactor. c.)Supplying and fixing of Time switch 24 hour programmer for street lights
SUB HEAD - 4 (EARTHING)
Providing earthing chamber of 400 x 400 x 400mm with a cast iron cover. As per latest IS standards, technical specifications.
SUB HEAD - 5 (SAFETY EQUIPMENT)
Providing & fixing danger plates made of mild steel at least 2 mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as read.
a. High Voltage - size 250 mm x 200 mm
b. Medium Voltage - size 200 mm x 150 mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers confirming to IS 2878:1976 and cylinders fully charged of following capacity. a. 4.5 Kg
Supply and fixing of foam fire extinguishers, Portable type 9 ltr capacity hanged on wall with bracket complete as required.
Providing of 9.5 ltr capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint "FIRE" and mounted on MS angle iron frame with bracket of appropriate size & capacity including filling of sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade/Indian Red Cross confirming to IS 2217:1963.
SUB HEAD - 6 (DISMANTLING, SHIFTING, TRANSPORTATING OF DG SET, TRANSFORMER AND OTHER ALLIED WORKS)
Dismantling, Shifting of 500KVA plinth mounted transformer with DP structure and all accessories. Dismantling, & Shifting of LT panel, APFCR panel from old electrical panel room to new electrical room Work includes removing of LT cables and reconnecting to transformer, LT Panel, APFC panel at new location. Complete with all necessary equipments, machinery etc.,
Dismantling & Shifting 11KV Outdoor Metering Cubicle mounted in the plinth, clearing the plinth and releasing of 11KV structures materials of 1 Nos., 8 pole structure, 1 Nos., 4 pole structure and 1 Nos., 2 pole structure complete with GOS, HG fuse, insulators, cross supports, line conductors complete and transporting to Electrical Sub Division-III premises. Complete with all necessary equipments, machinery etc.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
TenderDocument.pdf
Tender Documents • 4.46 MB
BOQ_942188.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid