| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC AOC | |
| 2 | L2₹23.2 L+₹2.9 L (14.3%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹23.4 L+₹3.1 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹23.4 L+₹3.1 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹24.5 L+₹4.2 L (20.6%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Rejected being |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Mar 2025, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE N AMB 77 2024 25 REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION SUB MAIN WIRING AND DISTRIBUTION BOARD IN JCOS OR MD ACCN AREA II OF SECTOR B OF AGE EM N AMBALA OF GE N AMBALA
2025_MES_699815_1
GE(N)/AMB-77/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (N) AMBALA CANTT
As per NIT
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹80,000
Yes
15 Apr 2025
1 Mar 2025
31 Mar 2025
1 Mar 2025
29 Mar 2025
15 Mar 2025
1 Mar 2025 - 15 Mar 2025
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description all as per serial item No.02 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for one socket outlet 6 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 04 socket point executed in one circuit. (ii) Each socket point will be measured and paid as per point.
Description all as per serial item No.02 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 02 socket point executed in one circuit. (ii) Each socket point will be measured and paid as per point.
Description all as per srl item No 02 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit. (ii) Each socket point will be measured and paid as per point.
Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet multipin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair electronic Fan regulator, modular 100 watts, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair calling bell, ding dong, 230 volt, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement, LED lamp 9 watts, threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED batten fitting 10-12 watts, 2 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS10WLED865SPCSS of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS20WLED865SPCSS of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, LED surface mounted bulk head luminaries, 8-10 watts, with min 800 lumen, industrial model, IP 65, aluminium housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. HEXAFT10WLED857SSYMBOPC of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, 9/12 watt LED light fitting heritage wall mounting fixture (sketch type) including B-22 LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings complete all as specified and as directed by the Engineer-in-Charge. Cat part No. HLWB-01-B22 of make Halonix or equivalent in make given in Appx 'B'.
Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 20 -25 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge. Cat part No.ENDURASUNDOWNSL25WLED765PASYBOTGIHD of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, service bracket of mild steel pipe 25 mm bore medium grade of length 0.70 mtr fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and washer and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED post top luminaire, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories,suitable and including B22 LED lamp 15 watt, internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge. Cat part No. HLPT-04-B22 of make Halonix or equivalent in make given in Appx 'B'.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811955 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fixing as in repair, PCB unit suitable for BLDC ceiling fan of 1200mm sweep single phase, 240 volts of make crompton, Halonix, Havells etc complete all as specified and as directed by the Engr-in-charge. Note : PCB unit will be replaced by rep of concerned OEM only.
Supply and fixing as in repair modular (PVC sheet) cover plate with support frame 3 ways suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing as in repair modular (PVC sheet) cover plate with support frame 4 ways suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing as in repair modular (PVC sheet) cover plate with support frame 6 ways suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing as in repair modular (PVC sheet) cover plate with support frame 8 ways suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing as in repair modular (PVC sheet) cover plate with support frame 12 ways suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing GI/MS (terminal boxes) rectangular block with earth dolly duly painted internally and externally with two coats of anti corrosive paint over a coat of redoxide primer including provision of new 3 modular cover plate with support frame over sunken box fixed with brass screw and cup washer for mounting, modular switches, sockets outlets, fan regulator etc. complete all as specified and as directed by the Engr-in-charge.
All as per above item No. 31 but new 4 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge.
All as per above item No. 31 but new 6 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge.
All as per above item No. 31 but new 8 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge.
All as per above item No. 31 but new 12 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge.
All as per above item No. 31 but new 1 module cover plate with support frame complete all as specified and as directed by the Engr-in-charge.
Supply and fixing GI, 'D' clamp heavy duty superior quality and nut and bolts with locking arrangement for hanging of ceiling fan, complete, all as specified and as directed by the Engr-in-charge.
Supply and fixing GI fan rod 600mm long and 15mm dia heavy duty with superior quality and nut and bolts with locking arrangement complete all as specified and as directed by the Engr-in-charge.
Supply and fixing GI fan rod 1 metre long and 15mm dia heavy duty with superior quality and nut and bolts with locking arrangement complete all as specified and as directed by the Engr-in-charge.
Disconnecting electric/water supply connection, taking down carefully geyser of any capacity, deposting to MES store yard for repair and refixing the same after repair at desired location complete all as specifed and directed by Engr-in-Charge. Note: Repair work shall be measured and paid separately.
Supply and fixing heating element cup or triangle type of 2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating elements complete all as specified and as directed by the Engr-in-charge.
Supply and fixing thermostat switch for geyser of any type ISI marked including taking out old unserviceable thermostat switch complete all as specified and as directed by the Engr-in-charge.
Supply and fixing geyser inner tank assembly suitable for geyser capacity of 25 Ltr including taking out old unserviceable tank assembly, complete, all as specified and as directed by the Engr-in-charge.
Supply and fixing in repair, heating element, 2 KW, having inbuilt thermostat as required at site for geyser of any make and descriptions complete including taking out old unserviceable heating elements, all as specified and as directed by the Engineer-in-Charge.
Supply and fixing brass chromium plated non return valve 15mm bore with air lock release arrangement including taking out old unserviceable non return valve, complete all as specified and as directed by the Engr-in-charge.
Supply and replacing 20 Amps metal clad socket & top as per existing socket and top including taking out old unserviceable metal clad socket top, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing in replacement flexible cable PVC insulated and sheathed, 3 core, circular multi stranded copper conductor of 1.50 Sqmm including removing unserviceable cable, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing PVC connection pipe 600 mm long and 15mm dia having wire mesh coating over it with brass nuts and washers suitable for connecting geysers inlet and outlet with GI tubings including taking out old unserviceable connections of any description all as specified and as directed by Engr-in-charge.
Supply and fixing top plug 15 Amp, 3 pin including taking out old unserviceable plug top complete all as specified and as directed by the Engr-in-charge.
Supply and fixing indicating lamp green/red in colour 230 volts as per existing make including removing unserviceable items,complete all as specified and as directed by the Engr-in-charge.
Material and labour for opening the stator & rotor of the 1200mm sweep ceiling fan, cutting the existing burnt winding and rewinding the fan with superior quality copper wire and filling the varnish as insulation between each winds & covering each loops of winding by sleeves and paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush, condenser and shackle housing , gun metal bushes, ball bearings, twin twisted copper cable, down rod assembly & canopy ,split pins complete including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed. Note:- (i). The quoted unit rate shall also be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule separately. (ii). New parts shall be of respective makes of fans. (iii). Unserviceable /defective retrieved parts shall be credited under sch of credit. (iv). After assembling all fans shall be tested for the speed as directed. (v) Cost of rewinding with winding copper wire & connected items shall be included in this item.
Description all as per serial item No 51 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per serial item No 51 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair heavy duty exhaust fan 300 mm sweep with corrosion resistant metallic body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, metallic base frame with rubber mountings for silent operation, 6 pole, maximum watt input not more than 55 watt, 2100 RPM, minimum air delivery 600 cum/hr with metal blades and shutter type louvers self-openable/ closeble for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge. Cat part No 70001 of make Bajaj or equivalent make given in Appx 'B'.
Supply only PVC canopy cover set superior quality for ceiling fan, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing of heavy duty exhaust fan 250mm sweep with corrosion resistant PVC body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, PVC base frame with rubber mountings for silent operation, maximum watt input not more than 25 watt, 1400 RPM, minimum air delivery 210 cum/hr, PVC blades and shutter type louvers self-openable/ close able for protecting the entrance of birds and testing as in repair complete all as specified and as directed by Engineer-in-Charge. Cat part No 70049 of make Bajaj or equivalent make given in Appx 'B'.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans , complete all as specified and as directed by the Engr-in-charge.
Supply only bearing for 250 to 450 mm sweep Exhaust fans, complete all as specified and as directed by the Engr-in-charge.
Supply only rubber clamp of suitable size for hanging of 1200-1400 mm ceiling fans in 40/50 mm GI pipe, as in repair complete all as specified and as directed by the Engr-in-charge.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan ,complete all as specified and as directed by the Engr-in-charge.
Supply and fixing in repair, mild steel louver and shutter self openable/closable for 300mm sweep, exhaust fan, superior quality complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion.
Supply only flexible cable PVC flat insulated and sheathed, 2 core, circular multi stranded copper conductor of 1.5 Sqmm including removing unserviceable cable, complete all as specified and as directed by the Engr-in-charge.
Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.Cat part No 811035 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing MCB SPN, 63 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811037 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing in repair MCB four pole and neutral 415 Volts, 63 Amps, 16 KA, 50 Hz thermal adjustable type complete all as specified and directed by the Eng-in-charge. Cat part No 811220 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing MCB SP, 40-63 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811016 to 811018 of make Indoasian or equivalent make given in Appx 'B'.
Supply and fixing sheet metal enclosure Vertical triple pole & neutral(VTPN) IP-54 including MCCB 160 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811882 + 830020 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing sheet metal enclosure triple pole & neutral(TPN) IP-54 suitable for RCBO 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811857 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811824 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811826 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing sheet metal MCB DB SPN 12 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811828 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing as in repair, MCCB, 4 pole, 63 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge. Cat part No.830020 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing as in repair, MCCB, 4 pole, 100 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge. Cat part No.830022 of make Indo Asian or equivalent make given in Appx 'B'.
Supply and fixing RCBO 2 pole 32 Amps 2 modules as incomer confirming to IEC-61009-1 with breaking capacity 10kA and sentisitivity 100mA having overload, shortcircuit and earth leakage protection with fault indicator complete all as specified and directed by Engr-in-Charge.
Supply and fixing RCBO 4 pole 63 Amps 4 modules as incomer confirming to IEC-61009-1 with breaking capacity 10kA and sentisitivity 100mA having overload, shortcircuit and earth leakage protection with fault indicator complete all as specified and directed by Engr-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Note:- Amount of credit of Rs.1,57,059.00 for retrieved materials is mentioned in Schedule of Credit Page No…………………. of tender documents in pdf form which will be deducted offline while acceptance of tender.
Saurav Enterprises (BID ID -3268648)
Goyal Engineers (BID ID -3267072)
M/S HARCHARAN SINGH (BID ID -3268448)
bharat contrectors (BID ID -3273146)
power house batteries (BID ID -3273415)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .