XEN, JPDCL, ED, RAJOURI
OFFICE OF XEN, JPDCL, ED, RAJOURI
SITC OF DEDICATED 11KV FEEDER FROM 33/11 KV R/STN NONIAL TO BSF CAMP BARARI NOWSHERA.
2022_PDD_186885_1
EDR/53 of 2022-23 Dated 03/09/2022
Open Tender
Electrical Works
Turn-key
60 days
NOWSHERA
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
XEN, JPDCL, ED, RAJOURI
₹12,880
4 Nov 2022
3 Sept 2022
26 Sept 2022
3 Sept 2022
23 Sept 2022
3 Sept 2022
Amount
11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, Insurance, Unloading, Carriage, Delivery at Site including handling, preservation and proper storage at site.
9 Mtr. Long ST Poles (410, SP-33) (As per recommended IS/REC Standard)
30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard)
GI Channel Cross-arm (75 x 40x6mm) with GI Angle Braces, GI Pole Top Bracket (50x50x6 mm) including GI Back Clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard. (As per recommended IS/REC Standard)
11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard)
11 kV DISC WITH FITTINGS( 45 KN) (As per recommended IS/REC Standard)
Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole
Earthing complete by GI Pipe 40mm or G.I Rod 20mm, 2.5mtr long through GI Strip.
Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles 1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete.
AL PAINT + RED OXIDE.
11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard)
ANTI CLIMBING DEVICE WITH CLAMPS (As per recommended IS/REC Standard)
Danger Plate with clamps having writing in english and regional language. (As per recommended IS/REC Standard)
Galvanized Nuts and Bolts of sizes.
Erection/Installation, Testing and commisioning of material supplied at Sl. No-1.01
Erection of 9 Mtr. Long ST Poles including (410, SP-33) with pit excavation and refilling of pit complete work. (As per recommended IS/REC Standard)
Laying, stringing and binding of 30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard)
Fixing / Erection of GI Channel, GI Cross Arms (100x50x6mm) / (75x40x6 mm) / GI Angles (50x50x6 mm) with 50X8 mm GI Back clamps without drilling/punching holes in the ST poles. (As per recommended IS/REC Standard)
Fixing of 11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard)
Installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard)
Laying of Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level including plaster and curing of concrete in size of 600x600x1800 mm for st poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders). Please refer pole drawings for details.
Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Installation and fixing of Sub station earthing as per REC approved arrangement/spacing by GI Pipe 40 mm dia 4 mm wall thickness or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) with Earthing Insulators, GI Nuts, Bolts and Clamps. Refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover (Proper Earthing Value must be insured) (As per recommended IS/REC Standard)
Fixing of Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles 1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard).
Painting of pole by 01 coat of Red Oxide & 02 Coats of Aluminium.
Installation of 11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard)
Installation of ANTI CLIMBING DEVICE WITH CLAMPS (As per recommended IS/REC Standard)
Fixing of Danger Plate with clamps having writing in english and regional language. (As per recommended IS/REC Standard)
Fixing of Galvanized Nuts and Bolts of sizes.
M/s Destiny Builders
SHAH ELECTRICALS
Fazal Hussain
HITECH ENTERPRISES
VEENA CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .