| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC KEDLA NAGAR 09 P O KEDLA P S MANDU DISTT RAMGARH JHARKHAND 825325 | RAMGARH | RAMGARH | JHARKHAND | 825325 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹3.8 L+₹2,345.20 (0.62%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹3.8 L+₹4,934.60 (1.30%)Rejected-Finance 2ND FLOOR 76A PHUL SARAI RANCHI ROAD DISTT RAMGARH JHARKHAND | RAMGARH | JHARKHAND | L3 | Rejected-Finance Due to L3 |
Tender Value
₹4.5 L
EMD Value
₹5,600
Closing Date
14 Mar 2025, 6:00 pmClosed
Project Engineer (Excavation), Tapin North OCP
Office of Project Engineer (Excavation), Tapin North OCP, Hazaribagh Area
Repairing of isolator, VCB assembly And repairing of wiring circuit of Swing generator and resistance panel and wiring harness of LVCR assembly to propel motor and steering system for EKG-5A shovel sl. no. - 554 at Tapin North OCP.
2025_CCL_331112_1
PE(X)/Tapin (N) OCP/NIT/24-25/57 Dated 04.03.2025
Open Tender
Excavation Department Work
Item Rate
15 days
Tapin North OCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,600
21 Apr 2025
4 Mar 2025
15 Mar 2025
4 Mar 2025
14 Mar 2025
4 Mar 2025
4 Mar 2025 - 8 Mar 2025
Amount
Repairing of isolator and VCB: Repairing of handle mechanism with new materials
Repairing and replacement of fixed and moving contacts, insulator and Arc chute
Repairing of Tie rod and its mechanism
Replacement of vacuum interrupter bottles
Replacement of economy resistance
Replacement of holding coil
Replacement of flexible connections, terminals and support insulators.
HT Electrician: 02 person X 06 days
Semi-Skilled: 03 person X 06 days
Contractor profit@10%
Harness of swing generator to DC panel (Q50mm2) – 14 meter X 2 nos. Harness of Propel motor to LVCR (Q50mm2) – 15 meter X 2 nos.
Harness of swing generator to DC panel (Q6mm2) – 14 meter X 11 nos. Harness of field of propel motor to LVCR (Q6mm2) – 15 meter X 02 nos.
Harness of steering motor and steering system (Q6mm2) – 15 meter X 05 no. Harness for supplementary wire (Q6mm2) – 15 meter X 01 no.
Cutting electrode for gauging of cracked portion of DC panel structure and bulged portion. electrode- L-602)
Suitable steel electrode for material filling and welding of support plate of DC panel structure (electrode- Lomelt-205)
Harness of resistance panel RB1 and RB2 to DC Panel : Crowd motor ckt. (Q6mm2) – 5mtr X 5nos.
Hoist motor ckt. (Q6mm2) – 5mtr X 5nos.
Swing motor ckt. (Q6mm2) – 5mtr X 6nos.
Propel motor ckt. (Q6mm2) – 5mtr X 2nos.
Trip motor ckt. (Q6mm2) – 5mtr X 3nos.
Supplementary ckt. (Q6mm2) – 5mtr X 1no.
Conduit kit
Replacement of copper lugs and binding cords.
Highly skilled – 01 person per shift X 07 days
skilled – 02 person per shift X 07 days
Welder-02 person per shift X 03 days
Semi-skilled – 03 person per shift X 07 days
Contractor profit@10%
Total impact of GST for the purpose of CTC
SRI SAI ENTERPRISES (BID ID -1139971)
VIDYA ENTERPRISES (BID ID -1140129)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .