| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹17.6 L+₹71,230 (4.21%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC OTHER LOWEST BIDDER | |
| 3 | L3₹18.3 L+₹1.4 L (8.17%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC OTHER LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
21 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT - 133001
REPAIR MAINT REPLACEMENT OF ELECTRIC OH UG NETWORK SYSTEM AND MISC WORKS AT RACE COURSE POWER HOUSE UNDER GE UTILITY AMBALA CANTT
2021_MES_444014_1
GE(U)/AMB-10/2021-22
Open Tender
Civil Works
Item Rate
240 days
AMBALA CANTT
AS PER TENDER DOCUMENMTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹36,000
Yes
31 Jul 2021
24 May 2021
23 Jun 2021
24 May 2021
21 Jun 2021
7 Jun 2021
24 May 2021 - 5 Jun 2021
60 days
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete al las specified and directed by Engineer-in-Charge.
Description all as per Item Ser No 1.00 above but exceeding 1.5 mtr deep but not exc 3.0mtr deep.
M & L sand cushioning for cable with river washed clean dry sharp sand and punning to provide required cover as per SSR Part I complete all as specified and as directed by Engineer-in-Charge. Note- Punned thickness shall be measured and paid to the contractor.
Supply and laying old size bricks common burnt clay sub class 'B' for cable protection to provide required cover complete all as specified and as directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (using 40mm graded aggregate, mechanically crushed stone) for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, coping, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as specified and directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable PCC/steel tubular pole any type and any size after disconnecting all electrical connection incl clearance of site complete all as the direction of Engr-in-Charge.
Supply and erection of PCC pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing of two coats of cement based paint from top to last strip and two coats of black and white strips with synthetic enamel paint 30 cm high each alternate strip 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid for separately. (ii) Description and matter as specified and directed by Engr-in-Charge will be printed on each pole without any extra cost.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 400 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm complete all as directed by Engr-in charge. Note: Earth work will be measured and paid separately.
Supply and fix in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as directed by Engr-in charge. Note: Earth work will be measured and paid separately.
Supply and fix in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-400 Sqmm complete all as directed by Engr-in charge. Note: Earth work will be measured and paid separately.
M&L drilling hole of any size manually or mechanically as per site requirement, drilling for laying pipes under the road for crossing electrical cables complete all as per direction of Engr-in-charge. Note: Pipe will be measured & paid for separately.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc all as directed. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 25 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 35 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 50 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 95 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 150 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 185 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 300 Sqmm.
Description all as per Item Ser No 20.00 here in before but for 3.5 core 400 Sqmm.
Supply and fixing stay assembly complete with all accessories, such as stay plate 230X230X6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 incl taking down old unsvcomplete all as specified nd directed . Note: Only excavation and PCC work will be measured and paid separately.
M & L in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint with synthetic enamelled paint complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement shackle type porcelain vitreous white or brown insulator including GI straps, washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm height, 90 mm dia, section of strap 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm height and 65 mm dia with GI spindle two GI washer and one GI nut complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable ACSR conductor incl cutting, welding complete all as per direction of Engr-In-Charge.
M&L aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator of any size as required at site complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed by Engr-in Charge.
Dismantling and taking down old u/s earthing and Material & labour earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old u/s earthing and Material & labour earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
Material and labour in replacement GI tubing 50 mm bore light grade, on poles,on walls, under floors, road crossing, as reqd at site complete all as directed by Engr-in Charge. Note: Clamps, Nut bolts, saddle etc will be measured and paid separately.
Description all as per Item Ser No 38.00 above butt 80 mm dia
Supply and Fixing in replacement MCCB TPN 400 Amps , 415 Volts, 50 KA ,4 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB TPN 250 Amps , 415 Volts, 40 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB TPN 160 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection all as per direction of Engr-in-Charge.
M&L for detecting of fualt in cable of any type with fault locator equipment which is capable to supply as per cable of serviceable to cable. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting making Joint will be paid under relevant item.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete as per direction of Engr-in-Charge.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 5 line as per IS complete as per direction of Engr-in-Charge.
Re-stretching existing/retrieved ACSR conductor on LT pole and binding conductor on insulator properly using new binding wire/jumper wire complete all as directed at site by Engr-in-Charge. Measurement should be taken in RM on span of 2,3,4&5 line of OH conductor. Note : (i) repl of old to new OH conductor shall be measured & paid for separately.
Material and labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type.
Material and labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type.
Material and labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type.
Material and labour shifting heavy items / excavating / cleaning areas / clearing site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete, all as specified and as directed.
Material & Labour cleaning and repair of LT panel of size upto 0.6 X 0.6X 0.6 mtr after cleaning of surface including removing rusted particles. removing dust, tightening nut,bolts , welding and painting on complete panel with one coat of synthetic enamel smoke grey colour paint including stand complete all as directed. Note: (i) Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate. (ii) Cost of misc items like copper cable, lugs, thimbles etc if required are included in quoted rates.
Material & Labour cleaning and repair of LT panel of size upto 1.2 X 1.2 X 0.6 mtr after cleaning of surface including removing rusted particles , removing dust, tightening nut, bolts, welding and painting on complete panel with one coat of synthetic enamel smoke grey colour paint including stand complete all as directed. Note: (i) Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate. (ii) Cost of misc items like copper cable, lugs, thimbles etc if required are included in quoted rates.
Material & Labour surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with one coat of synthetic enamel aluminium paint including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with one coat of cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement / PCC.
Material & Labour one coat cement based paint on PCC pole 9 mtr long including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with one coat cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement / PCC.
Supply and fixing in repair On load change over switch with Sheet Steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair On load change over switch with Sheet Steel Enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair On load change over switch with Sheet Steel Enclosure 415 V, 4 pole, 315 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engr-in-Charge.
Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 400 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
Supply and fixing MCCB 315 Amps, 25 KA 4 pole 415 Volts AC, adjustable type, complete all as directed by Engg-in-charge (incoming)-01 No.
Supply and fixing MCCB 100 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type ISI marked all (Outgoing)-03 Nos.
RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 600 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
Supply and fixing MCCB 400 Amps, 50 KA 4 pole 415 Volts AC, adjustable type, complete all as directed by Engg-in-charge (incoming)-01 No.
Supply and fixing MCCB 125 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type ISI marked all (Outgoing)-04 Nos.
RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
Notes for item Sr No. 58.00 & 59.00 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through gland. (vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
Note :- Amount of credit of Rs. 142700.00 for retrieved materials is mentioned in Schedule of Credit(Revised) mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
sanjeev enterprises
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .