| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹33.6 L | L1 | Accepted-AOC AOC, Being the Lowest Bidder |
| 2 | L2₹37.7 LRejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹37.7 L | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹38.4 LRejected-Finance | ₹38.4 L | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹38.6 LRejected-Finance C 347 ARBUDHA NAGAR ODHAV AHMEDABAD | AHMEDABAD | AHMEDABAD | GUJARAT | 382415 | ₹38.6 L | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹38.7 LRejected-Finance | ₹38.7 L | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Shree Builders L5 | Ramdev and Sons L3 | Haritwal traders L7 | Navkar Enterprises L4 | BEYLIM INFRA L8 | K K Construction Co L6 | Abhishek Enterprises L2 | ALBA AC AND REF SERVICES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing & injecting chemical emulsion for Post Constructional Anti-termite Treatment with external wall where the apron is not provided using chemical emulsion at the rate 7.5 liters per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavation channel/trench along the wall and rodding etc. complete all as specified and directed | 2,730 | Sqm | 270 ₹7.4 L | 280 ₹7.6 L | 280 ₹7.6 L | 266 ₹7.3 L | 290 ₹7.9 L | 276 ₹7.5 L | 299 ₹8.2 L | 243 ₹6.6 L |
| 2.00 | Providing & injecting chemical emulsion for Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre along the skiirting/dado and sealing the same complete all as specified and directed | 6,820 | RM | 152 ₹10.4 L | 120 ₹8.2 L | 158 ₹10.8 L | 150 ₹10.2 L | 150 ₹10.2 L | 155 ₹10.6 L | 113 ₹7.7 L | 108 ₹7.4 L |
| 3.00 | M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed . | 2,180 | Sqm | 397 ₹8.7 L | 482 ₹10.5 L | 411 ₹9.0 L | 390 ₹8.5 L | 502 ₹10.9 L | 406 ₹8.9 L | 474 ₹10.3 L | 432 ₹9.4 L |
| 4.00 | M&L for complete removal of existing treatment from old wall surfaces and applying two coats of oil bound distemper over sufficient coat of birla wall putty complete all as specified and directed. | 1,790 | Sqm | 97 ₹1.7 L | 96 ₹1.7 L | 101 ₹1.8 L | 96 ₹1.7 L | 102 ₹1.8 L | 99 ₹1.8 L | 94 ₹1.7 L | 90 ₹1.6 L |
| 5.00 | S&F aluminium partition made with powder coated aluminium anodised section 62.30mm x 44.45mm x 1.50mm fixed in wall/floor including provision for receiving glass pane/ACP sheets etc and fixing the same with aluminium anodised beading and rubber gasket including 5.0 mm thick glass (black/ tinted/ plain) or ACP sheet as per site requirements and all necessary fittings complete as in partition complete all as specified and as directed. | 34 | Sqm | 5,101 ₹1.7 L | 5,890 ₹2.0 L | 5,275 ₹1.8 L | 5,000 ₹1.7 L | 6,025 ₹2.0 L | 5,224 ₹1.8 L | 5,784 ₹2.0 L | 4,320 ₹1.5 L |
| 6.00 | M&L for preparing of old surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed. | 60 | Sqm | 99 ₹5,940 | 86 ₹5,160 | 103 ₹6,180 | 98 ₹5,880 | 87 ₹5,220 | 101 ₹6,060 | 85 ₹5,100 | 81 ₹4,860 |
| 7.00 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. | 170 | Kg | 193 ₹32,810 | 164 ₹27,880 | 200 ₹34,000 | 190 ₹32,300 | 167 ₹28,390 | 197 ₹33,490 | 161 ₹27,370 | 153 ₹26,010 |
| 8.00 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. | 25 | Sqm | 170 ₹4,250 | 144 ₹3,600 | 176 ₹4,400 | 167 ₹4,175 | 147 ₹3,675 | 174 ₹4,350 | 142 ₹3,550 | 135 ₹3,375 |
| 9.00 | Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil complete all as specified and as directed. | 8.95 | Cum | 342 ₹3,060.90 | 289 ₹2,586.55 | 354 ₹3,168.30 | 336 ₹3,007.20 | 295 ₹2,640.25 | 350 ₹3,132.50 | 284 ₹2,541.80 | 270 ₹2,416.50 |
| 10.00 | M&L for PCC (1:4:8) type D2 using 40mm graded agg as in foundation and mass concrete complete all as specified and as directed. | 0.89 | Cum | 6,691 ₹5,954.99 | 5,601 ₹4,984.89 | 6,918 ₹6,157.02 | 6,558 ₹5,836.62 | 5,729 ₹5,098.81 | 6,852 ₹6,098.28 | 5,499 ₹4,894.11 | 5,220 ₹4,645.80 |
Tender Value
₹32.4 L
EMD Value
₹64,780
Closing Date
24 Feb 2026, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF POST CONSTRUCTION ANTI TERMITE TREATMENT IN CERTAIN BLDGS, WORK SERVICES REQUIRED FOR CUAS, SETTING UP INFRASTRUCTURE OF IMMOLS SERVER ROOM AND ADDN/ALTN TO BLDG NO P 5 AT AF STN WADSAR UNDER GE (AF) CHILODA
2026_MES_751056_1
8380/25-26/E8
Open Tender
Civil Works
180 days
WADSAR
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹64,780
Yes
27 Mar 2026
3 Feb 2026
26 Feb 2026
3 Feb 2026
24 Feb 2026
18 Feb 2026
3 Feb 2026 - 17 Feb 2026
Providing & injecting chemical emulsion for Post Constructional Anti-termite Treatment with external wall where the apron is not provided using chemical emulsion at the rate 7.5 liters per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavation channel/trench along the wall and rodding etc. complete all as specified and directed
Providing & injecting chemical emulsion for Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre along the skiirting/dado and sealing the same complete all as specified and directed
M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
M&L for complete removal of existing treatment from old wall surfaces and applying two coats of oil bound distemper over sufficient coat of birla wall putty complete all as specified and directed.
S&F aluminium partition made with powder coated aluminium anodised section 62.30mm x 44.45mm x 1.50mm fixed in wall/floor including provision for receiving glass pane/ACP sheets etc and fixing the same with aluminium anodised beading and rubber gasket including 5.0 mm thick glass (black/ tinted/ plain) or ACP sheet as per site requirements and all necessary fittings complete as in partition complete all as specified and as directed.
M&L for preparing of old surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40mm graded agg as in foundation and mass concrete complete all as specified and as directed.
Returning filling in, including, spreading, levelling, watering and well ramming in layers n. exc. 25 cm complete all as specified and as directed.
Removing excavated material n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and as directed.
M&L for from work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work n.exc. 200 mm thick curved ( horizontal or sloping ) with fair finished surfaces for flat roof complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticla or to batter complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers,columns, and stanchions complete all as specified and as directed.
M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and as directed.
M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, underremaed pliles and mass concrete complete all as specified and as directed.
M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Chajjas complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified and as directed.
All as per item No 23 here in before but 5mm dia and over up to and including 10 mm dia in stirrups, spaces and binders.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as specified and directed by Engineer-in-Charge. (Note : Water proofing liquid shall be measured and paid separately)
Supply for integral liquid water proofing compound
M&L for rendering 5 mm thick on fair faces of brick work on concrete surfacs in CM (1:3) on ceiling surface finished even and smooth (w/o using extra cement) complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying three coat of white wash on ceiling complete all as specified and as directed.
M&L for sub main wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in suitable PVC conduit Complete all as specified and directed by Engr-in-Charge.
S&F MCB DB SPN 8 way complete in SS enclosure double door type with 200 amps rated busbar complete all as specified and directed by Engr-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge. (i) S & F MCB SP 230 volts 6- 32 Amps with 10KA breaking capacity.Complete all as specified and directed by Engr-in-Charge.
All as per item No 33 here in before but S & F MCB SPN 230 volts 32 Amps with 10KA breaking capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing of single pole and neutral encloser with a two pin and earth plug and socket complete with one single pole MCB 240V, 20Amp complete all as specified and directed by Engr-in-Charge.
M&L for providing CHEMICAL earthing complete with copper plate electrode 900 mm x 600 mm x 5 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of Chemical and connected to Copper earth strip 32 x 6mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ) complete all as specified and directed by Engr-in-Charge.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-Charge. Note :- Necessary tool / plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted for above item.
M&L for copper brazing (welding) at site to connect loop copper earthing strip of any size after tightening by nut, bolt, washer, check nuts of brass complete all as specified and as directed by Engr-in-charge. Note: Copper brazing shall be done upto 20 mtr height. Necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted for above item.
S&F Industrial Plug and socket with enclosure and complete internal wiring complete all as specified and as directed
M & L for disconnecting & taking out of split AC indoor and out door unit by cutting of copper tube and disconnecting of electric cable & shifting of indoor/outdoor unit to another or same location with refilling refrigerant gas and fixing & testing after connecting all the parts in position complete all as specified and directed by Engr-in-Charge.
M&L for aluminium strip 25X3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F MCB DB SPN 4 way complete in SS enclosure double door type with 200 amps rated busbar complete all as specified and directed.
M& L for Air termination, single pointed, copper rod 12mm Dia and 300mm long complete all as specified and directed.
M&L for test point terminal block made of gun metal or phosphorus size 75X75X25mm drilled and screwed including 3 nos 8mm dia 25 mm long hex head screw complete all as specified and directed.
M/L for Maintenance free Chemical Earthing of technology 3 mtr long 17.20 mm dia with 250 micron copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia alongs with 2 bags of 25 kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95% carbon content. The testing laboratory should be an ISO 9001 and 14001certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7 - 8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 KA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and poly plastic pit cover of meterial polymer body & cover dimensions 308mm (L) x 308 mm (W) 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. ( NOTE :- (i) Earthing is to be done infront of the Engr-in-Charge. (ii) The test result of earthing to be submitted by the contractor for all earthings. (iii) The contractor shall have to give written guarantee for maintenance earth resistance of less than 1 ohm for the period of 10 (Ten) years after certified date of completion and shall be depositted 2000/- per earthing as security deposit for a period of Ten (10) years.(iv) Failing to maintain resistance of earthing less than 1 ohm new earthing to be provided by the contractor without any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata returning, filling in and making good surround area complete. Complete all as specified and directed by Engr-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tenderdocuments8380.pdf
Tender Documents • 0.89 MB
BOQ_841171.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid