Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance KALARIKKAPARAMBIL BRAHMAPURAM PO AMBALAMUGAL ERNAKULAM | ERNAKULAM | ERNAKULAM | KERALA | 682303 | Admitted-Finance |
| 2 | Admitted-Finance 7 569A PONNAMKULATH NEAR BALABHADRA TEMPLE EDAYAPPURAM ASHOKAPURAM ALUVA PIN 683 101 ERNAKULAM DIST KERALA | ALUVA | ERNAKULAM | KERALA | 683101 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Feb 2024, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOD (MKTG AND PPC)
KEL MAMALA KOCHI
PROJECT NO. 1283/24- ESTABLISHMENT OF FIRE and SAFETY AT TIRUR DISTRICT HOSPITAL, MALAPPURAM- PHASE I
2024_KEL_652400_1
KRO/BDC/1559/2024
Open Tender
Civil Works - Others
Item Rate
300 days
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,900
₹50,000
Yes
9 Feb 2024
31 Jan 2024
8 Feb 2024
31 Jan 2024
7 Feb 2024
31 Jan 2024
31 Jan 2024 - 7 Feb 2024
Amount
Civil Works
16.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
50.4.1.1 : Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc.
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
19.18.3 : Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
50.18.9.2.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2
50.18.9.3.2 : Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
50.18.9.5.2 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints compete as per direction of Engineer in Charge. 40 mm dia 6 Kgf/cm2
50.18.9.12.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od168516/2023_2024 : 200mm 4kg Rain Water Gutter Round - PVC
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
od168591/2023_2024 : Door frame with Shutter :105x60x1.5(16G) Frame section, 35mm thick outer sheet on both side , using .80mm outer sheet , with stiffness and filled with resin bonded honeycomb craft paper, fitted with SS ball bearing Hinches, Mortice lock and automatic door closer (Godrej), SS tower bolt, and finally applied powder coating PO Red, Size:1000x2100, SS Ball bearing Hinches, Mortice lock - Godrej, Automatic door closer, Vision Panel:20x40
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
od169971/2023_2024 : Providing Cores on Slab or beam less than 200 mm of size from 100 to 180 mm diameter including cost and conveyance of all materials, including removal of debrises all labour charges
Electrical Works
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.1.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 70 sq mm
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm
90.12.6.30 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
90.12.1.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm
od168682/2023_2024 : Supply and installation of 6 kva inverter with batteries 4 Nos/100AH/12 V
od168683/2023_2024 : 'Supply ,installation testing and commissioning of extra panel board attachment to existing main panel/MSB including 100 A switches and isolators with existing DG supply support for feeding supply to Fire pump Panel including spares.
od168684/2023_2024 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. 63A 10KA TP MCB (C curve)
od168685/2023_2024 : Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
od168686/2023_2024 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
od168687/2023_2024 : Supplying and fixing of following sizes of flexible conduit along with accessories in surface/recess as required. (16/ 20mm.)
od168688/2023_2024 : Supply, conveyance, installation, testing and commissioning the following types of light fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. 20W LED Tube light
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
od168689/2023_2024 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 Amp, 16 KA, FP MCCB
Fire Fighting System
od170135/2023_2024 : ;MAIN PUMPSupply, installation, testing and commissioning of electrically operated Main Pump of 2280 LPM capacity 55 MWC, high efficiency volute type with cast iron casing, cast iron impeller, pump coupled with a squirrel cage induction motor SPDP type with a supply condition of 415 V 50 Hz foot mounted type for Appx. 50 HP at 2900 RPM 3 kg including base plate coupling guard and all other necessary accessories. ;
od170136/2023_2024 : ;DIESEL PUMPSupply, installation, testing and commissioning of electrically operated Diesel Pump of 2280 LPM capacity 55 MWC, high efficiency volute type with cast iron casing, cast iron impeller, pump coupled with a squirrel cage induction motor SPDP type with a supply condition of 415 V 50 Hz foot mounted type for Approx. 52 HP at 2900 RPM 3 kg including base plate coupling guard and all other necessary accessories. ;
od170137/2023_2024 : ;JOCKEY PUMPSupply, installation, testing and commissioning of fire fighting Jockey Pump Of 180 LPM, 60 mtr head horizontal end suction centrifugal multi stage electronic driven auto start jockey pump coupled with SPDP motor working on 415 V, 3 phase, 50Hz approx. 7.5 HP ;
od170139/2023_2024 : ;EXHAUST PIPESupply, installation, testing and commissioning of MS 'B' Class Exhaust Pipe for diesel engine pump;
od170140/2023_2024 : ;PRESSURE SWITCHSupply, installation, testing and commissioning of Pressure switch arrangement for pump room and total system;
od170650/2023_2024 : ;AIR CUSSION VESSELSupply, installation, testing and commissioning of air cushion Vessel 200 mm dia with stand pressure of 15 kg /cm2 with automatic air release cock, bronze make 25 mm dia ball valve, drain pipe, bronze drain valve and shut off having a length of 120cm ;
od170141/2023_2024 : ;PRESSURE GUAGESupply, installation, testing and commissioning of Pressure gauge arrangement for pump room and total system;
od170142/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.150 mm dia ABOVE GROUND PIPING;
od170143/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.100 mm dia ABOVE GROUND PIPING;
od170144/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.80 mm dia ABOVE GROUND PIPING;
od170145/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.65 mm dia ABOVE GROUND PIPING;
od170146/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.50 mm dia ABOVE GROUND PIPING;
od170147/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.40 mm dia ABOVE GROUND PIPING;
od171063/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.32 mm dia ABOVE GROUND PIPING;
od170148/2023_2024 : ;Supply, installation, testing and commissioning of MS 'B' class medium pipe as per is Medium grade ISI mark of following dia, with necessary fittings such as nuts & bolts, bends, flanges ,etc and Welded joints, The pipe shall be painted with two coats red colour enamel paint over primary coat of Primer.25 mm dia ABOVE GROUND PIPING;
od170149/2023_2024 : ;Supply, installation, testing and commissioning of underground piping M S pipe Class 'B' Medium grade ISI mark complete with all necessary fittings such as nuts & bolts, bends, flanges, tees etc . and piping shall have anti corrosive wrapping treatment.150 mm dia UNDER GROUND PIPING;
od170150/2023_2024 : ;Supply, installation, testing and commissioning of underground piping M S pipe Class 'B' Medium grade ISI mark complete with all necessary fittings such as nuts & bolts, bends, flanges, tees etc . and piping shall have anti corrosive wrapping treatment.100 mm dia UNDER GROUND PIPING;
od170151/2023_2024 : ;Supply, installation, testing and commissioning of underground piping M S pipe Class 'B' Medium grade ISI mark complete with all necessary fittings such as nuts & bolts, bends, flanges, tees etc . and piping shall have anti corrosive wrapping treatment.80 mm dia UNDER GROUND PIPING;
od170179/2023_2024 : ;Supply, installation, testing and commissioning of butterfly valve wafer type Stainless steel/SG iron disc , lever operated as per IS:13095 in PN 1.0 , teflon or nylon bushing, nitrile O rings in standard mounting flanges with hand lever type.150 mm dia BUTTERFLY VALVE;
od170180/2023_2024 : ;Supply, installation, testing and commissioning of butterfly valve wafer type Stainless steel/SG iron disc , lever operated as per IS:13095 in PN 1.0 , teflon or nylon bushing, nitrile O rings in standard mounting flanges with hand lever type.100 mm dia BUTTERFLY VALVE;
od170181/2023_2024 : ;Supply, installation, testing and commissioning of butterfly valve wafer type Stainless steel/SG iron disc , lever operated as per IS:13095 in PN 1.0 , teflon or nylon bushing, nitrile O rings in standard mounting flanges with hand lever type.80 mm dia BUTTERFLY VALVE;
od170182/2023_2024 : ;Supply, installation, testing and commissioning of butterfly valve wafer type Stainless steel/SG iron disc , lever operated as per IS:13095 in PN 1.0 , teflon or nylon bushing, nitrile O rings in standard mounting flanges with hand lever type.50 mm dia BUTTERFLY VALVE;
od170183/2023_2024 : ;Supply, installation, testing and commissioning of Non Return Valve single plate wafer type slim seal check valve, short pattern type with integral hinge pin disc , nitrile rubber O - ring seat and face sealing as per IS: 5312.150 mm dia NON RETURN VALVE;
od170184/2023_2024 : ;Supply, installation, testing and commissioning of Non Return Valve single plate wafer type slim seal check valve, short pattern type with integral hinge pin disc , nitrile rubber O - ring seat and face sealing as per IS: 5312.100 mm dia NON RETURN VALVE;
od170185/2023_2024 : ;Supply, installation, testing and commissioning of Non Return Valve single plate wafer type slim seal check valve, short pattern type with integral hinge pin disc , nitrile rubber O - ring seat and face sealing as per IS: 5312.80 mm dia NON RETURN VALVE;
od170186/2023_2024 : ;AIR RELEASE VALVESupply, installation, testing and commissioning of Air release valve gun metal body as per IS:778 of 25 mm dia .;
od171067/2023_2024 : ;Y STAINERSupply installation testing and commissioning charges of Y Type Strainer cast iron body with leather gasket. 150 mm dia;
od170187/2023_2024 : Supply, installation, testing and commissioning of Hydrant valve 63 mm dia oblique type with Gun Metal body & working parts, with instantaneous hose coupling adaptor and PVC blank cap & chain. ISI Marked.
od170188/2023_2024 : ;FIRE HOSESupply, installation, testing and commissioning of Fire Fighting Hose , all synthetic fiber circular woven jacketed, synthetic rubber lined fire hose, delivery , 38kg/cm2 burst pressure, 22kg/cm2 proof pressure, 14 kg/cm2 working pressure, bearing IS:636-88 type A , in 15 mtrs length, 63 mm dia, duly bounded with SS coupling 63 mm dia pair of male & female parts, instantaneous type.;
od170189/2023_2024 : ;HOSE REEL DRUMSupply, installation, testing and commissioning of Hose reel drum made of Mild Steel, with mounting brackets 19 mm dia nylon braded smooth surface rubber hose 25 mtrs length with shut off nozzle;
od170190/2023_2024 : Supply, installation, testing and commissioning of branch pipe made out of SS 63 mm short male instant. Inlet male threaded outlet, fitting with 15 mm bore nozzle ISI
od170191/2023_2024 : ;HOSE BOXSupply, installation, testing and commissioning of Hose Box (Fire Hose cabinet) to accommodate one piece of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS with glass fronted hinged doors and lock.;
od170192/2023_2024 : ;Supply, installation, testing and commissioning of Ball Valve20 mm dia BALL VALVE FORGED BRASS;
od170193/2023_2024 : ;Supply, installation, testing and commissioning of Ball Valve25 mm dia BALL VALVE FORGED BRASS;
od170194/2023_2024 : ;ALARM CHECK VALVE Supplying, Installing, testing and commissioning of 150mm Installation Control Valve with gong, bell, trim & complete kit.;
od170195/2023_2024 : ;FOOT VALVESupply, installation, testing and commissioning of Foot Valve;
od170196/2023_2024 : ;FIRE BRIGADE CONNECTIONSupply, installation, testing and commissioning of 2 way Fire brigade Inlet connection fabricated from 100 mm dia MS Class B medium grade pipe comprising of three 63 mm dia gun metal male threaded non return valve. ;
od170197/2023_2024 : DRAW OUT CONECTION: Supply, installation, testing and commissioning of Draw out conection for Fire Tank 100 mm dia, comprising of four 100 mm dia gun metal female male threaded .
od170198/2023_2024 : ;SPRINKLERSupply, installation, testing and commissioning of Sprinkler 15 mm size , 1/2;; BSPT end connection having temp. rating 68 deg. C made out of forged brass and SS decorative finish with supports. UL listedPendent type;
od170199/2023_2024 : ;SPRINKLERSupply, installation, testing and commissioning of Sprinkler 15 mm size , 1/2;; BSPT end connection having temp. rating 68 deg. C made out of forged brass and SS decorative finish with supports. UL listedSide Wall;
od170200/2023_2024 : Supply, Installation, Testing and Commissioning of approved type Rosette plates for Sprinklers below false ceiling area. The Rosette shall be chrome plated & shall be as approved by architects / consultants.
od170201/2023_2024 : ;FIRE ALARM SYSTEMSupply, installation, testing and commissioning of Fire Alarm Control Panel 9 Zone conventional type micro processor based control panel of MS cabinet powder coated audio and visual display with all necessary attachments ;
od170202/2023_2024 : MANUAL CALL POINT: Supply, installation, testing and commissioning of Manual Call Point break glass type powder coated MS box ,24/12 Volt DC operated, and with necessary attachments.
od170203/2023_2024 : HOOTER: Supply, installation, testing and commissioning of Audio alarm hooter (sounder) powder coated MS box, 24/12 Volt DC operated with necessary attachments.
od170204/2023_2024 : ;DETECTORS: Supply, installation, testing and commissioning of detectors with all accessories like base etc to be installed under or above false ceiling , UL ApprovedSmoke detectors;
od170205/2023_2024 : ;DETECTORS: Supply, installation, testing and commissioning of detectors with all accessories like base etc to be installed under or above false ceiling , UL ApprovedHeat detectors;
od170206/2023_2024 : ;FLOW SWITCHSupply, installation, testing and commissioning of Flow switches complete with all accessories;
od170207/2023_2024 : ;FIRE ALARM CABLESupply , Installation , Testing and Commissioning of 2 C x 1.5 SQ.MM FRLS PVC insulated and PVC sheathed aluminium armoured multi stranded Copper conductor cable, RED coloured with ISI mark;
od170208/2023_2024 : ;SIGNAGESSupply, installation of in position the signages of ;;Fire boards approved by Kerala state fire service - size 1ft x 4ft made out of PVC rigid sheet 3mm thick with computer cut PVC non-reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws;. with lettering ;ASSEMBLY AREA;
od170209/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.;FIRE EXIT;
od170210/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.EXIT;
od170211/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.FIRE DUCT;
od170212/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.NO SMOKING;
od170213/2023_2024 : Supply, installation of in position the following type of sign boards made out of 3mm thick ;Opaque; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. EVACUATION PLAN
od170214/2023_2024 : Supply, installation of in position the following type of sign boards made out of 3mm thick ;Opaque; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. FLOOR INDICATION
od170215/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.FIRE LIFT;
od170216/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.CONTROL ROOM;
od170217/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.EXIT ( LED TYPE);
od170218/2023_2024 : ;Supply, installation of in position the following type of sign boards made out of 3mm thick ;;Opaque;; PVC foam board with computer cut, PVC Non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.FIRE EXIT ( LED TYPE);
od170219/2023_2024 : ;FIRE EXTINGUISHERSupply, installation, testing and commissioning of Fire Extinguisher ABC type fire extinguisher ISI mark ,4 kg capacity with initial charger and installation brackets.;
od170221/2023_2024 : Supply, installation, testing and commissioning of 6 Watt. Wall mounted Speakers. (Two way)
od170222/2023_2024 : ;FIRE ALARM CABLESupply, installation, testing and commissioning of Fire Alarm Cable - PVC insulated fire retardant copper flexible wire 1 sq.mm with ISI mark.;
od170223/2023_2024 : PVC CONDUITSupply, installation, testing and commissioning of 20 mm dia medium grade rigid PVC conduit ISI mark with elbow, tees, jn: boxes, saddle clip and with necessary fittings.
Preparation of necessary electrical documents, forms, drawings, schemes, certificates, etc. and getting approval from statutory authorities
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
10. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
11.DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref.
12.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
13.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
14.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
15. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
16.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
SABANI ENGINEERS
SAAJCONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .