Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 CrAccepted-AOC P O P S UDALGURI WARD NO 2 DIST UDALGURI BTC ASSAM | UDALGURI | ASSAM | 784113 | ₹31.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹31.9 CrRejected-AOC C O SRI HANUMAN PRASAD BAJAJ WARD NO 02 U T ROAD P O DIST UDALGURI BTC ASSAM | UDALGURI | ASSAM | 784113 | ₹31.9 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹31.9 CrRejected-AOC | ₹31.9 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹30.9 Cr
EMD Value
₹61.8 L
Closing Date
14 Feb 2020, 4:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of District Centre at Udalguri in Udalguri District.
2020_BTC_16190_1
07/ACE/InfraDev/BTC/2019-20/16
Open Tender
Civil Works - Building
1095 days
BTC
Refer to SBD
6 documents required · 6 mandatory
₹15,000
Principal Secretary, BTC, Kokrajhar
₹61.8 L
Yes
5 Mar 2020
1 Feb 2020
15 Feb 2020
1 Feb 2020
14 Feb 2020
1 Feb 2020
1 Feb 2020 - 14 Feb 2020
Amount
(CIVIL, SANITARY & WATER SUPPLY WORKS INCLUDING SEPTIC TANK, SOAK PIT, DEEPTUBE WELL ETC) CIVIL WORKS: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
(b) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the initial depth of 2m
Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered) (B) Above 1.5 m upto 3.00 m depth
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. © With silt (predominantly non plastic) by truck carriage including loading and unloading.
Supplying and filling sand gravel in foundation trenches of column footings over slushy soil including local carriage of materials within 8 km pumping out of water, ramming etc. complete for strengthening the bearing capacity of the soil as directed and specified including payment of Forest Royalty and Sales Tax and other duties and taxes as may be necessary.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser c) M25 grade concrete
(B) In super structure from plinth level up to 1st floor level. i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. N) Without using admixture, plasticiser c) M25 grade concrete
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser c) M25 grade concrete
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.4.1
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. (b) Non Decorative Type and Block Board core (ii) 35 mm thick
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I. Plain Grill (c) Fixed to Brickwork/P.C.C/R.C.C.
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Johnson/Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Normal range Johnson/ Somany/ Orient/Nitco/Asian Make ii) Of size 200mmx300mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (iii) Kumari Slab
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) Ceramic tiles i) Normal range (Sizes 300 mm x 300mm and above)
Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) Any shade or combination of shades using white cement. (b) MULTIWYN TILES Legato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta, Nexus, Koral
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. a) In cement mortar 1:3
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side (b) In cement mortar 1:4
(B) On fair side (b) In cement mortar 1:4
20 mm thick cement plaster in two coat, backing coat 15 mm anf finishing coat 5 mm thick on rough side of single or half brick for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (backing coat 15 mm and finishing coat 5 mm thick) (b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. ii) Two coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. ii) Two coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. b) On two coat plaster
Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying one self-priming coat of Unicem "Shakti" brand of required shade over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b) With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "Red-Lead"/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. i) Surfaces over 100mm in width or girth a) General purpose (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac.)
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). (A) a) Side hung and Top hung windows and ventilators ii) 5mm frosted glass
(ii) v: 5 mm coloured glass
(B) (b) Fixed windows and ventilators (i) (v) 5 mm coloured glass
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (A) (a) 2 Track sliding window (v) 5 mm coloured glass
(B) (b) 3 Track sliding window (v) 5 mm coloured glass
Providing, fitting and fixing anodised aluminium framed double leaf glazed doors with anodised aluminium frame made of 100mm x 45mm x 2mm sections with door styles of size 81mm x 45mm x 2mm, top rails 50mm x 45mm x 2mm, lock rails 81 mm x 45mm x 2mm,bottom rails 100mm x 45mm x 2mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the Department at all levels. (vi) 5 mm coloured glass
Providing, fitting and fixing anodised aluminium framed double leaf glazed doors with partition walls partly glazed and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections with door styles of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81 mm x 43mm x 2mm fitting with glazing clips, special type rubber gasket including hydraulic floor spring at all levels. (iv) 6mm coloured glass
Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels. (i) 6mm thick glass panes and 12mm prelaminated board
Providing and fixing anodised aluminium framed single leaf door of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mmx15mmx1.2mm complete with automatic hydraulic floor mounted door closure, butterfly type handles, special cylindrical locks, concealed type tower bolt,neoprene dryset rubber gusket, etc.complete as directed by the Department at all levels. (i) 5mm thick frosted glass and 12mm thick prelaminated board
(vi) 5 mm clear glass
Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) A) (a) Sliding door bolts (i) 300 mm x 16 mm
B) (b) Tower Bolt (ii) 250 mm x 12 mm
C) (c) Door Handle (iii) 150 mm
(D) (t) Door stopper with rubber stopper
(E) m) Mortice lock vertical type ii) 75mm(Godrej with handle(4 lever)
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard. False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary). (ii) 12.5mm MRB
Providing & fixing Armstrong Mineral fibre Acoustical suspended ceiling system with optra FG ( board/tegular) edge tiles with armstrong XL 24mm exposed grid (600x600x15)mm
Supplying, fitting and fixing SoundSoak NSS Cord (FSS Cord) wrapped acoustical wall panel system of Anutone Acoustics Ltd. Including all fixtures and fittings. d) Armstrong Wood works acoustical wall panelling
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.45 mm thick
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. a) 100mm thick slab
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
SANITARY WORKS: Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm (a) White (i) Parryware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) (A) Parryware make (a) White (iii) Universal Closet P Trap (Cat No.C0272) (inclusive of seat cover)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (A) Parryware make (a) White (i) Economy Single Flush (Cat No.C8090/C8055)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Basin (without pedestal) (B) Hindware Make (a) White (iii) Tunga Basin 450 x 300 (Cat. No.C0401)
Wall Hang Basin (C) Jaquar Make (i) Cat. No.CNS-WHT-WB04 (550 x 400 x 198)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (A) Parryware Make (vi) Single Bowl (160 x 180) Flat Edge - Glossy (Cat.No.C8538)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make (a) White (iv) Flat Back (Cat. No.C0501/72)
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing fitting and fixing Glass Shelf complete as directed and specified.
Glass shelf with C.P. guard rail (ii) Sona make (Cat. No.TR-0701) (c) 600mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (b) Sona Make (i) Soap dish light (Cat.No.TR-0661)
Providing, fitting and fixing CP towel rail complete as directed and specified. (b) Sona make (iii) Towel rail Diplomat 600mm long (Cat.No.TR-0605)
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (d) Sona make (i) Super (Cat. No.AL-1001)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
75mm dia.
Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
75mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
75mm dia.
Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (ii) 110mm dia.
75mm dia.
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (ii) 110mm dia.
(iv) 75mm dia.
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
75mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (i) 110mm dia.
(ii) 75mm dia.
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm dia.
75mm dia.
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (i) 110mmx110mm
(ii) 75mmx75mm
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mmx110mm
(ii) 75mmx75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (ii) 110mm dia.
75mm dia.
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
(iv) 75mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (iv) 110 mm x 75 mm
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 110 mm x 75 mm
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. A) (a) In exposed surfaces or in trenches. (ii) 110 mm x 75 mm
B) (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 110 mm x 75 mm
Supplying fiting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. A) (b) 110mm.
B) (c) 75mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. A) (a) 110mm dia
B) (b) 75mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
WATER SUPPLY: Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls b) 40 mm dia (Medium)
i) Using Tata make ii) c) 32 mm dia (Medium)
i) Using Tata make (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. d) 25 mm dia (Medium)
i) Using Tata make e) 20mm dia (Medium)
i) Using Tata make iii) f) 15 mm dia (Medium)
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquare make (a) Continental /Clarion (i) Standard
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquare make (a) Continental /Clarion (i) 15mm dia Male/Female (long thread)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (III) Jaquar make (a) Continental
Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) (V) Jaquar make a) Continental /Clarion ii) Sink-cock with raised 'J' shaped swinging spout
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (III) Jaquar make a) Continental (i) Shower arm 190mm long light body with wall flange
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia
c) 25 mm dia
d) 20 mm dia
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia ( Heavy type)
WATER TANK: Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 litre capacity a) Sintex make
Labour for erecting and placing the G.I. Tank over the stagging of a height above 5.00m up to 8.00metre complete as directed. (c) 2000 litre capacity
DEEP TUBE WELL: Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. viii) Bore hole of 250mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (II) PVC Pipe (a) SUPREME /PRINCE / FUSION /SFMC Brand viii) 200mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. (I) G.I. Pipe a) TATA / SAIL (Medium)socket should be welded to the pipes. ix) 150mm diameter
Supplying fitting and fixing GI filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. d) 50 mm dia
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
SEPTIC TANK: Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. (viii) 100 Users
INTERNAL ELECTRIFICATION WORKS: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Short point up to 3.00 metre. length.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
MODULAR SWITCH Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 1-2 module type Metal
3 module type Metal
4-5 module type Metal
6-8 module type Metal
10 module type Metal
12-16 module type Metal
24 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 1 module
2 module
3 module
4 module
6 module
8 module
10 module
16 module
24 module
Supplying including fitting and fixing of TV co-axial outlet MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.
Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in bell push with LED MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SUPPLY AND FIXING OF RIGID PVC CONDUIT (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) IN SURFACE AND RECESS WIRING SYSTEM: Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
Wiring with P.V.C. insulated unsheathed 1.1 K.V. grade single core copper conductor FR cable in existing surface/ recessed conduit wiring system: Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper)
EPABX Supplying ,installation, testing & commissioning of Distribution Box 20 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)
Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required.
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB enclosure incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 4 way single door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN Double Door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 25A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 100A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make) [ F ]
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Ventil Air DB 300 mm sweep (Havells make) [EF]
Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalent make) Striker HI- Speed , 400 mm sweep Usha make) / Wind flow with plastic blade 400 mm sweep Crompton make).
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Core - 3.5A2XFY 25 Sq.mm 3 and 1/2 core armoured cable
70 Sq.mm 3 and 1/2 core armoured cable
Supplying, installation of GI PERFORATED cable tray on wall or from ceiling including necessary channel, nuts and bolts, washer etc. as required as directed and specified by the department. (LEGRAND/ AKG /STRUTFAST make). Size of Tray 304
Supplying, installation, testing and Commission of the following indoor Decorative Recessed mounted 2' x 2' LED down lighter luminaries of model no- RC380 B LED 36S-6500 G4 L60 PSD OD WH OC / RC380 B LED 36S-6500 G4 L60 PSD OD WH OC / LCTRS-36-TL / LCTRS-36-CDL / IO2830RP00 / IO2840RP00 / IO2850RP00 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Crompton / LT make). [CLS]
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-DN 394B LED 16 S -6500 PSU WH / MV1857RLOO / MV1840RLOO /MV1830RLOO / MV1830RLOO / MV1857R500 / MV1857R500 / MV1840RLOO / CRDL11R023HP57 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / LT / Wipro make). [DL]
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. B118601000 [FL]
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN021C LED 20 PSU CW GR S2 [TL]
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 / L00930R000 /LD90-111 - XXX-65-XX complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make). [CL]
Supplying, installation, testing and Commission of the following indoor LED Decorative Surface Square typed optics down lighter luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department Square type Superior finish extruded white powder coated pressure die cast aluminium body with High transmitivity, non Yellowing PMMA diffuser with driver and accessories pre-wired upto terminal block assembly. LED Luminaires of make WIPRO Cat No. IrisLED Slim SQ SM LD81-171-XXX-60-SM LED 18W or equivalent inlcuding lamps etc. complete [CLT]
Supplying, installation, testing and commissioning of the following LED luminaries complete with all accessories such as ballast, starter etc. in the ceiling including Y type suspension arrangement as specified by the manufacturer, and fixing the same on ceiling by perfect arrangement for load bearing as well as, to be match with the colour and design of the ceiling, of required length [max. 1.5 m] including making necessary connection cable, as approved by the Deptt.)with 1.5 sq mm.PVC.insulated.S.C.copper conductor as required and as directed by the department. department. Slimmest Suspended Superior finish extruded white powder coated pressure die cast aluminium body with High transmitivity, non Yellowing PMMA diffuser with driver and accessories pre-wired upto terminal block assembly. LED Luminaires of make WIPRO Cat No. AuraPlusLED CRCO13R038HP57G1 31W or equivalent inlcuding lamps etc. complete [DTL]
Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
EXTERNAL ELECTRICAL WORKS: Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 No. 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4.00 Sq.mm 3 Core armoured U.G. cable
6.00 Sq.mm 3 Core armoured U.G. cable
25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
150.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
185.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
300.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 A2XWY A2XFY 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
150.00 Sq.mm 3&1/2 Core U.G. cable in 80mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
185.00 Sq.mm 4 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
300.00 Sq.mm 4 Core U.G. cable in 100mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supplying including installation of cast iron cable marker as specified and directed by the deptt.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 185-300 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Pole Type BOP or equivalent-1030 Height 10 m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts :- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. :- (A/ 70, Bottom Dia.:- (A/ 175, Sheet Thickness :- 3mm, Base Plate Dimensions :- (L x B x 275 x 275 x 16, Foundation Bolt Size:- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia. (PC :- 270, Bolt Length:- 750, Projected Bolt Length :-125, Anchor plate thickness :- 4 mm, Pole Foundation :-The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation :- The foundation shall be done with ( Earth work :- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres. Steel:- 22.43 Kg. Shuttering :- 4.32 square metres. = 22.43 Kg.
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : Single arm bracket 1500mm long for 3m to 10 metre. Poles.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. 3 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 3 HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel.
Supplying including installation testing and commissioning of 200kVAr, 440V APFC Panel Non-Compartmentalized Type, Free Standing, Floor Mounted
Supplying, installation, testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection with build in LED of the following landscape luminarie ( POST TOP ) suitable for 38mm dia post top mounting applications including connections with 2.50 sq.mm 3core multistrand P.V.C. insulated round copper cable as required and directed by the department. [PTL] CROMPTON MAPLE CAT REF: LPTO-60-CDL/M
Supplying,installation,testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection of the following street light including connection with 2.5 Sq.mm. 3 core PVC insulated round copper conductor as required and as directed by the department. [STL] BRP 410 LED 094 CW HE MR FG S2 PSU GR
Fabrication, supply and erection of 4.5 Mtr. Long 75mm dia MS pole with MS base plate of 300x300x10mm thickness at the bottom of the pole with fixing arrangement for post top lantern and to accomodate a junction box. The foundation is of cement concrete of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate) size 0.8 x 0.8 x .35 m with collar of size 0.4m dia x 0.5m height to accomodate the looping type cable end box including excavation and refilling etc. as required. The pole shall be painted with one coat of red oxide primer and two coats of aluminium paint.
Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum 165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items. a) 12mm x 2mm x 15cm long 2 strip copper Bus Bar - 1 set b) 6-32 Amp "L" series DP MCB - 1 No. c) 6 amp "L" series SP MCB as outgoing - 2 Nos.
Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
630 KVA SUBSTATION AND 11KV O H LINE AND SECURITY DEPOSIT WORKS: Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 410 SP 66 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
Drawing of 11KV overhead line including necessary insulators angles frames stay wires etc. as necessary and load security deposit to be deposited to concerned Power Supply Agency with APDCL/ASEB check meter as well as permission from Power Supply Authority including liasioning with all the concerned departments etc..
250 KVA DIESEL GENERATOR SET: Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV TECHNICAL DATA CJ250D5P GENERATOR SET SPECIFICATIONS 250/200 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 6CTA-8-3G4 3. No. of Cylinders. 6 4. Aspiration. TURBO CHARGED AIR COOLED 5. Cooling. Water Cooled. 6. Governor. Electronic 7. Battery Capacity Rating. 2x12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 40.8 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 WITH STANDARD CONTROL PANEL
BOUNDARY WALL: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (b) M20 or Prop. 1:11/2:3
(B) Super-structure from plinth level upto 1st floor level. (ii) Columns, Pillars, Posts, Struts, Suspended Floor, Roof, Landing, Shelf and support, Balcony, Lintel, Sill Band, Beam, Girder, Bressumer, Cantilever, Staircase (Except Spiral Staircase and landing) including preparing the top surface and finishing of nosing. (b) M20 or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank
Columns, pillars, posts and struts (a) Square, Rectangular, polygon in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25 mm thick plank
112 mm thick 1st class brick nogged walls including racking out joints and curing complete as directed in super structure above plinth upto 1st floor (Protruding M.S Rod/ Torsteel of column to be embedded in cement mortar and will measured and paid separately) (a) In Prop 1:4
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. a) ii Super ductile TMT Reinforcement Bar
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following. a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. b) Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed. c) Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
20 mm thick cement plaster in two coat, backing coat 15 mm anf finishing coat 5 mm thick on rough side of single or half brick for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.5 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. ii) Two coat plaster
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade , thinning by adding water as per specification of the menufacturer after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.(b) Unicem Shakti
2 NOS R.C.C BOX CULVERT: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop. 1:4:8 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. (ii) Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (b) Floors etc. above 200mm in thickness.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
600 MM WIDTH R.C.C BOX DRAIN: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop. 1:4:8 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. (ii) Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (b) Floors etc. above 200mm in thickness.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (B) Allmanda / Khorika zai / May flower / Kamini / Kathanda / Tecoma / Acalypha / Bougainvillea / Dracaena / Togor / Nilakantha / Mussaenda
(B) With Hybrid tea rose / Miniatune rose
Supplying and planting of suitable plant materials for edge making (20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . (b) Adopting cross wise Double Row Planting Method (iii) With Brindavan / Latifolius
(A) Neem / Mahaneem / Beef wood / Bakul / Acacia / Siris / Devils tree / Kadam / Palash / Pink Cassia / peepal / Silver oak / Simalu / Ajar
(A) Gulmohar/ Ashok
(B) Kanchan
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
RCC APPROACH ROAD: Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.) b) From Government land
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (ii)Using Grading II material
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete a) TMT Bar (i) From Primary Producer
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., and removal of the same for in-situ reinforced concrete and plain concrete work in R.C.C. approach road (ii) Using 25mm thick plank
Providing and laying controlled cement concrete pavement of approved grade with 20mm down graded stone aggregate over a prepared sub-base including dewatering if necessary, spread, compacted and finished in a continuous operation including provision of construction and expansion joints, plasticiser and curing compound of Fosroc/Sika/Choksey/Degusa and hardener of Recron/Degusa/Fosroc;finishing to lines and grades and curing as specified and directed complete (form work and reinforcement shall be measured and paid separately). (a) M 20 Grade Concrete
15 mm thick Cement plaster in single coat with hardener of Recron/ Degusa/ Fosroc on brick/concrete for plastering including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b). In cement mortar 1:4
PAVED OPEN PARKING AREA : Providing soling in foundation and under floor at all levels with stone/ best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials, and if necessary dewatering, complete. (a) Brick on flat soling
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (ii) 35mm thick
Providing polished SUNROCK-Hi CTS/MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (A) (i) SUNROCK-Hi CTS
Supply, Installtion and Comissioning of Audio Visual Solution for Conference Hall: 18"Long Cardioid Condenser Gooseneck Microphone with on/off switch, LED ring light and Shock Mount. Output Impedence 180 Ω, Dynamic Range 93dB, Signal to Noise Ration 67dB and Frequency Response 70Hz-16000Hz. SHURE/EQUIVQLENT make. Model: CVG 18S-BC
Unified Series Core with 128x128 Network Audio Channels, 16x16 USB Audio Channels, 24 Channels of Total Analog Audio, 8 Configurable Flex Channels, 16x16 GPIO Logic Ports, 16 Channels of Routable AEC, Multiple Instance VoIP Lines, Single POTS Telephone line. QSC make. Model: Q Sys 110F
Energy Star Complied 2 Chanel Power Amplifier. Pwer 100W Per Chanel on 8 Ohms, 350W on 100V. Frequency Response (4Ω and 8Ω) 20 Hz - 20 KHz +/- 0.1 dB, Gain at 8Ω 25.0 dB, Output Circuitry Class D, Signal to Noise (20 Hz - 20 KHz) >100 dB. QSC make. Model No. SPA 2 200
Two Way Surface Mount Speaker with Directivity Matched Transition. Effective frequency range1 68 Hz – 20 kHz, Rated noise power / voltage 50 watts / 20 volts (rms), Maximum continuous SPL: 104 dB, Rated Impedence 8 Ohm, Coverage Angle 120 Degree, Transformer Tappings: 100V: 30, 15, 7.5 watts and 8 ohm bypass QSC make. Model: ADS 4T
Stereo EP Connector AMPHENOL make. Model: Custom
XLR Connector AMPHENOL make Model: Custom
RCA Connector AMPHENOL make Model: Custom
Interconnect Microphone Cable in meters Krystal make Model: Slim Digital
16 AWG Twin Parallel Tpt (50/.16mm) Speaker Cable in meters Krystal make Model: Transparent
3600 Lumens, WXGA Multimedia LCD Projector, Aspect Ratio 16:10, Resolution 1280X800 Pixels, Contrast 16,000:1, Lamp Life 10000 Hrs. Inputs: HDMI, VGA, Video & USM. PANASONIC make Model: PT LW 373
110" Diagoal Motorized Projection Screen in 16:10 ratio. Prolite/Liberty make Model: Custom
Hydraulic Type Table Pop-Up Box with HDMI, VGA, Audio, Universal Power and LAN Port Liberty make Model: JS 222
3ft Column Telescopic Universal Type Ceiling Mounting Kit Liberty make Model: Mark I
High Speed HDMI Cable. Length 20 Mtrs. AVECO make Model: 2L-7D15H
High Speed HDMI Cable. Length 1.8 Mtrs. AVECO make Model: HDLK3FT
3+6 Core VGA Cable woith both end moulded sockets. Length 20 Mtrs. Liberty make Model: Custom
3+6 Core VGA Cable woith both end moulded sockets. Length 1.8 Mtrs Liberty make Model: Custom
CAT 6 Cable UTP Cable D Link make Model: Custom
9 U Wall Mount Equipment rack with PDU and Fan. D Link make Model: 9U
Installation, Testing & Commissioning charge
CONFERENCE CHAIR: Supplying, Fitting & Fixing of Conference Chair as directed and specified…
Conference Table: Fitting, Fixing of Conference Table complete as per drawing and analysis Material cost ( Sunmica 1mm thick ) 8' x4'( 25 piece)..Rs. 1800.00 per piece ( Greenlam or similar make) Material cost ( 19mm plywood) Boiling water proof ( BWP) (8' x4') of Green Ply or similar make. 25 piece ..Rs. 125.00 per sqft…800Sqft x Rs.125.00 Teak Wood decorative Bead Sand paper 20 nos Nails , Channel, Hinge , Handle , lock & screws..Lump Sum Malamine Natural Polish ( Machine polish with material)
Air-Conditioner: Supplying including installation, testing and commissioning of Hi-Wall 4 Star Rating Non ducted Split type of the following capacity with cordless Remote complete with indoor & outdoor Unit,copper pipe & electrical connection as approved by the department upto 5.00M between the room unit and the out door unit as directed by the department. 1.5 Ton Capacity Blue star make model 4WAE181 YA
Supplying including installation Voltage Stabilizer of the following specification complete including making necessary connection as approved , specified and directed by the department ( Skyland/VeeDee/V Guard/Vertex/Indo/Venus make) 4.0KVA Automatic input 90-280V output 200-240 V ( Unit price Rs. 8450.00)
Supply with fitting & fixing of angle iron framing made of 50mm x 50mm x 5mm size angle iron for accomodation of 1.0T to 2.0Ton window / split AC machine ( Unit cost Rs. 2525.00 each)
Supplying with fitting and fixing Single Phase D. O. L Starter of the following specification complete including making necessary connection as specified and directed by the deptt. (a) Overload Relay Range 3.8 - 6.0 Amps for 2.2 KW
MAIN GATE: Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2 mts. below the existing Ground Level (a) In ordinary Soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (iii) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (b) M20 or Prop. 1:11/2:3
(B) Super-structure from plinth level upto 1st floor level. (ii) Columns, Pillars, Posts, Struts, Suspended Floor, Roof, Landing, Shelf and support, Balcony, Lintel, Sill Band, Beam, Girder, Bressumer, Cantilever, Staircase (Except Spiral Staircase and landing) including preparing the top surface and finishing of nosing. (b) M20 or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank
Columns, pillars, posts and struts (a) Square, Rectangular, polygon in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25 mm thick plank
Sides and soffits of beam, beam hunching, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) Using 25 mm thick plank
Flat surface such as soffits of suspended floors, roofs, landings, balconies, chajjas, horizontal ties and the like (a) Floors etc. upto 200mm in thickness. (ii) Using 25 mm thick plank
Brick work in cement mortar with 1st class bricks including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure upto plinth level (b) In Prop 1:4
112 mm thick 1st class brick nogged walls including racking out joints and curing complete as directed in super structure above plinth upto 1st floor (Protruding M.S Rod/ Torsteel of column to be embedded in cement mortar and will measured and paid separately) (a) In Prop 1:4
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. b) ISI approved super ductile TMT Bar (i) TATA/SAIL
Supplying, fitting and fixing anodised aluminium decorated grill with anodised aluminium rectangularframe of 'F' and 'H' section fitted with walls, columns or stiffeners by special type of screws as per specification by the Department for all levels.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Executive Range (Sizes 200mm x 300mm and above ) b) Orient made
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range (Size 600mm x 600mm) iv) Johnson made
18 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels. (A) (b) With 18mm thick marble stone tiles of size 600mm x 450 mm, 600mm x 300mm (iii) Kumari Marble
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (i) Normal Quality (ii) With White cement
10 mm thick cement plaster in single coat on fair side of brick/ concrete walls for interior platering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3
15 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, chamfers and/ or rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (A) In cement mortar 1:4
15 mm thick cement plaster in single coat on fair side of brick / concrete for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (B) In cement mortar 1:4
20 mm thick cement plaster in two coat, backing coat 15 mm anf finishing coat 5 mm thick on rough side of single or half brick for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) In cement mortar 1:4 (6.2.3)
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.5 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. (ii) Two coat plaster
Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying one self-priming coat of Unicem "Shakti" brand of required shade over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of waterproofing cement coatings of Unicem "Shakti" brand of required shade by thinning 1 part of paint with 1 part of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b) With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "Red-Lead"/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. i) Surfaces over 100mm in width or girth a) General purpose (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac.)
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
FIRE FIGHTING: Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supplying fitting fixing at site Wireless control Panel (99 zone Device) with Fire Alarm, MCP, Hooter and smoke detector as per company specifications for all the buildings of Residential complex .
EXTERNAL FIRE HYDRANT SYSTEM & HOSE REEL / DOWN COMER
AUTOMATIC LIFT: Supplying, Fitting & Fixing of Automatic Lift 8 passenger Auto Door, 04 stops, Machineroomless with Auto Rescue Device…as directed and specified.
EARTH FILLING ON ENTIRE SITE WITH 1.5M DEPTH: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fee, if any monopoly duty etc.(profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city.
ASHOK KUMAR BAJAJ
SRI UMTANG TIMUNG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid